• 제목/요약/키워드: Sluice

검색결과 156건 처리시간 0.051초

사석마운드 설치에 따른 조력발전용 수문의 통수성능 변화 (Change of Water Discharge Capability of Sluice Caisson for Tidal Power Plant According to Installation of Rubble Mound)

  • 이달수;오상호;이진학;박우선;조휴상;김덕구
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.266-269
    • /
    • 2008
  • In this study, the results of experimental investigation on the water discharge capability of sluice caisson for tidal power plant were presented. In particular, the focus of the study was placed on the examination of change in water discharge capability of a sluice caisson according to the installation of rubble mound. For this purpose, a hydraulic experiment was carried out in an open channel flume with a great care to the measurement of discharge and water level in the flume since they greatly affects the estimation of the discharge capability of each sluice caisson. In the analysis, the experimental data of four different sluice models were used, which showed that the installation of rubble mound affects in different manner depending on each sluice caisson model. When each of the four sluice models were placed on the rubble mound respectively, the water discharge increased for one sluice caisson, whereas decreased for other three sluice caissons. Further detailed analysis is needed to quantitatively estimate the influence of installation of rubble mound on the water discharge capability of a sluice caisson.

  • PDF

유압실린더 구동식 전도 수문의 실시간 모의시험기 개발 (Development of the Real-Time Simulator of a Turning-Type Sluice Gate Actuated by the Hydraulic Cylinder)

  • 이성래
    • 한국자동차공학회논문집
    • /
    • 제14권4호
    • /
    • pp.192-198
    • /
    • 2006
  • The real-time simulator of a turning-type sluice gate actuated by the hydraulic cylinders is developed using a PC and a visual C++ program language. The real-time simulator receives the directional control valve signal selected by the operator using the mouse, updates the state variables of the turning-type sluice gate system responding to the control signal, and draws the moving figures of the sluice gate, cylinder, reserved water every drawing time on the PC monitor. Also, the operator can observe the sluice gate angle, cylinder force, cylinder pressures, and hydraulic power representing the operation of sluice gate system through the PC monitor every drawing time. The simulator can be a very useful tool to design and improve the turning-type sluice gate system.

CFD를 사용한 조력발전소 수문의 통수성능 연구 (Numerical Investigation on the Water Discharge Capability of Tidal Power Plant Using CFD)

  • 김건우;오상호;한인숙;안석진
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.161-161
    • /
    • 2011
  • The design methodology of the sluice caisson structure is one of important factor that is closely related to the efficiency in tidal power generation. When the sluice caisson is designed to maximize the water discharge capability, it is possible to minimize the number of sluice caissons for attaining the water amount required for achieving the target power generation, which results in reduction of the construction cost for the sluice caisson structure. The discharge capability of sluice caisson is dependent on the geometrical conditions of an apron structure which is placed in both sides of the sluice caisson. In this study, we investigated numerically the variation of water discharge capability of sluice caisson according to the geometrical conditions of apron. Flow fields are simulated with FLOW-3D software using VOF method.

  • PDF

사석마운드 위에 설치되는 조력발전용 수문 케이슨의 통수성능에 대한 실험적 연구 (Experimental Investigation on the Change of Water Discharge Capability of Sluice Caisson for Tidal Power Plant Placed on the Rubble Mound)

  • 이달수;오상호;이진학;박우선;조휴상;엄현민
    • 신재생에너지
    • /
    • 제4권2호
    • /
    • pp.94-104
    • /
    • 2008
  • The change of water discharge capability of sluice caisson for tidal power plant according to installation of the rubble mound was investigated by performing laboratory experiment. The experiment was carried out in an open channel flume with a great care to measure flow rate and water level in the flume accurately. Eight different sluice caisson models were used in the experiment. The water discharge capabilities of seven sluice models decreased with respect to the placement of the rubble mound, while increased for only one sluice model. On average, the values of discharge coefficient decreased by approximately 10% when the sluice models were placed on the rubble mound. It is concluded that the shape of the rubble mound can affect the water discharge capability of the sluice caisson, so that its shape should be significantly considered in the design of the sluice caisson, especially when it is deployed in a site of relatively deeper depth.

  • PDF

작동력을 최소화시키는 순차작동-유압실린더식 수문의 설계 (Design of the Sequentially Operated-Hydraulic Cylinders Type Sluice Gate Minimizing the Operating Force)

  • 이성래
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.893-898
    • /
    • 2004
  • The hydraulic cylinder is used for actuating a sluice gate which controls the volume of water in the reservoir. Generally, the one cylinder type is used to operate the sluice gate. In order to reduce the required cylinder force to operate the sluice gate significantly, the sequentially operated-hydraulic cylinders type is designed and the optimal locating points of cylinders are searched using the complex method that is one kind of constrained direct search method.

  • PDF

조력발전용 수문케이슨의 통수성능에 관한 수리모형실험 (Physical Experiment on Water Discharge Capability of Sluice Caisson for Tidal Power Plant)

  • 이달수;오상호;이진학;박우선;조휴상;안석진
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.514-517
    • /
    • 2008
  • An hydraulic experiment was carried out in an open channel flume in order to investigate the water discharge capability of the sluice caisson for tidal power generation, which greatly affects the economical efficiency of the construction of a tidal power plant. To predict the influence of change in the major design parameters relating to the sluice shape on the water discharge capability of the sluice, the experiment was carried out very precisely. The experiment was carried out for the six different sluice models of different widths and bottom heights of the sluice throat section. The experimental data showed that the water discharge generally increased by increasing the width of the throat section if the side shape of the sluice was the same. In addition, the coefficient of discharge was larger when the bottom height of the throat section was higher for the two bottom heights that were tested.

  • PDF

수문용 대형 유압실린더의 신뢰성 평가 (Reliability assessment test for heavy sluice gate of hydraulic cylinder)

  • 이용범;현동수;김형의;이근호;정동수
    • 한국신뢰성학회:학술대회논문집
    • /
    • 한국신뢰성학회 2001년도 정기학술대회
    • /
    • pp.91-97
    • /
    • 2001
  • These Study are for the development of the reliability assessment test code and test equipment and test procedures of the heavy sluice gate hydraulic cylinder. Because there is no reliability test code for the heavy sluice gate hydraulic cylinder inside and outside of the country, the modified reliability test code is made reference for the related existing standards like as ISO, JIS, MIL, TUV, DIN, KS and etc. In this study, the novel method is proposed to evaluate efficiency of the heavy sluice gate hydraulic cylinder on the loading conditions and established the conditions of the acceleration life test to reduce the testing time and cycles. The testing equipments for life test, lode operating test, high and low temperature test and salt spray test have been established for 8 month, and the reliability tests are accomplished. The test results of the heavy sluice gate hydraulic cylinder which is produced and tested initially in Korea are satisfied the durability life cycle on the using conditions.

  • PDF

Sluice gate를 이용한 고립파 형상 발생조건에 관한 실험적 연구 (Laboratory experiment of conditions for solitary wave generated with sluice gate)

  • 조재남;최서혜;황규남;이승오
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2015년도 학술발표회
    • /
    • pp.378-378
    • /
    • 2015
  • 연안지역에서 발생하는 퇴적 및 침식현상으로 발생하는 피해를 분석하기 위하여, 고립파를 이용한 연구가 계속 진행되어왔다. 고립파는 파고의 크기에 따라 파형이 결정되는 특징을 가지고 있어 연안지역 파랑에 관한 연구에 적합하다. 기존연구는 sluice gate를 순간적으로 개방하는 방식을 통해 갑작스러운 수위의 변화를 유도하여 급변부정류흐름을 발생시키는 연구를 수행하였으나, 고립파 발생 조건에 대한 상세한 분석은 수행하지 못하였다. 본 연구는 기존연구에서 사용한 방식과 동일하게 sluice gate를 개방하여 고립파를 발생시켰으며, 실험조건을 상류 headtank 수위와 하류 수심의 수위차를 이용하는 경우와 sluice gate 개방 속도에 따라 두 가지 경우로 나누어 실험을 수행하였다. 실험에 사용된 직사각형 수리실험수조는 폭 0.8 m, 높이 0.75 m, 수로길이 12 m에서 상 하류의 수위차를 0.05 m 단위로 높이는 방식과 수문개방속도를 0.5 m/s 부터 1.0 m/s까지 범위를 설정하여 두 가지 재현방식에 따라 실험을 진행하였다. 또한 Flow-3D GMO(General Moving Objects)기능을 활용한 수치모의를 수행하였다. 실험조건에 따른 수리실험 결과를 파랑의 특성인 고립파 파고와 파속을 수치모의결과와 비교하여 분석하였다. 수리실험결과와 수치해석결과 유사한 경향을 나타내었으며, 본 연구의 결과는 Sluice gate를 이용한 고립파 수리실험으로 경사면에서 발생하는 침식과 퇴적현상에 관한 기초적인 연구가 될 것이다.

  • PDF

전도 수문용 폐회로형 유압장치의 작동 특성에 관한 연구 (Study for the Operational Characteristics of Closed Circuit Hydraulic System of Turnover-Type Sluice Gate)

  • 이성래
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.897-902
    • /
    • 2007
  • The turnover-type sluice gate is typically actuated by the open circuit hydrauic system since the single-rod cylinder is used rather than the double-rod cylinder. However, here the closed circuit hydrauic system is applied for the operation of turnover-type sluice gate for the purpose of convenient operation. The closed circuit hydraulic system of turnover-type sluice gate is composed of a bi-directional pump, single-rod cylinders, pilot operated check valves, check valves and a counter balance valve. The usefulness of the closed circuit hydraulic system is verified for the several operational conditions by the computer simulations.

  • PDF

수리실험에 의한 조력발전용 수문의 유량계수 산정에 관한 고찰 (Study on the Estimation of Discharge Coefficient of Sluice for Tidal Power Generation by Performing Physical Experiment)

  • 오상호;이광수;이달수;장세철
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.160.1-160.1
    • /
    • 2011
  • In this study, the influence of methodology of assessing water levels on the discharge coefficient of sluice for tidal power generation was investigated. A physical experiment was performed in a planar open channel by installing 1/70 scale model of the sluice caisson in the planar open channel. In front of and behind the sluice model, sloping bathymetry was made to reproduce corresponding field condition. By analyzing the experimental results, it was found that the location of measuring water levels significantly affects the estimates of the discharge coefficient, due to the variability of the parameter according to the head difference between the measuring locations. Therefore, it is necessary to be careful in estimating and utilizing the discharge coefficient in the relevant study of a tidal power generation.

  • PDF