• Title/Summary/Keyword: Sludge thickener

Search Result 19, Processing Time 0.022 seconds

Analysis of the sludge thickening characteristics in the thickener using CFD Model (CFD를 이용한 농축조 슬러지의 유출흐름특성 해석)

  • Park, No-Suk;Moon, Yong-Taik;Kim, Byung-Goon;Kim, Hong-Suck
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.777-782
    • /
    • 2011
  • The residual treatment facilities in WTP(water treatment plant) play an important role in solid-liquid separation. At present, it is difficult to solve problems related with thickening and dewatering of WTP sludge, and discharging waste water to river. The quantity of residuals generated from water treatment plants depends upon the raw water quality, dosage of chemicals used, performance of the treatment process, method of sludge removal, efficiency of sedimentation, and backwashing frequency. Sludge production by the physical separation of SS(Suspended Solid) occurs under quiescent conditions in the primary clarifier, where SSs are allowed to settle and to consolidate on the clarifier bottom. Raw primary sludge results when the settled solids are hydraulically removed from the tank. In this study, Drawing characteristics of the sludge thickening in the thickener of Water Treatment Plants was simulated by Using CFD(Computational Fluid Dynamics.

Improvement of effluent water quality by sludge aeration at the conventional drinking water treatment plant (정수장 슬러지 폭기를 통한 방류수 수질 개선)

  • Choi, Ilgyung;Shin, Changsoo;Beak, Inho;Lim, Jaecheol;Jeong, Chanwoo;Lee, Sungjin;Park, Jungwook
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.2
    • /
    • pp.249-255
    • /
    • 2014
  • So many drinking water treatment plants are under various difficulties by new reinforced effluent standards. Since the target turbidity, much higher than annual average, for designing sludge thickener have to be set to confront high turbidity season, the sludge at thickener should be put up for a long time during usual days. So the soluble manganese and chloroform may be formed under the anaerobic environment in the sludge thickener when the sludge retention time is longer with low turbidity. This phenomenon results in difficulties to keep regulatory level of the discharged effluent. For an effort to overcome the problems, a sludge aeration was successfully implemented into the thickening process. As a result, the final effluent quality and sludge volume were much improved; 41 % of manganese, 62 % of chloroform and 35 % of sludge volume. Additionally, effluent quality was improved ; 61 % of Manganese on aeration with pH control and we could make sure of stability effluent quality despite a long sludge retention time. We recommended the standard of installation sludge aeration equipment to nationally supply water treatment plant under effluent water quality problem ; Manganese, Chloroform, etc.

Influence of pH on Mn Concentration of Effluent from Sludge Thickener of Water Treatment Plant (정수장 슬러지 농축조 배출수의 망간 농도에 미치는 pH의 영향)

  • Kim, Younjung;Lee, Seungeun;Baek, Seungcheol;Kim, Taeheui
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.5
    • /
    • pp.27-33
    • /
    • 2015
  • Manganese in sludge precipitated during water treatment might be soluble again in effluent from sludge thickener. If that happens, the manganese concentration of effluent from water treatment plant will exceed the limit for clean reservation. In this study the influence of pH on Mn concentration of effluent from sludge thickener of water treatment plant was investigated. When the pHs of sludge solutions increased with alkaline materials such as NaOH, KOH, CaO, $Ca(OH)_2$, $CaCO_3$, the Mn concentrations of sludge solutions decreased under the limit. The Mn concentration of effluent from sludge thickener could be controlled with waste limestones from beneficiation process at limestone mine as an alkaline material.

A Study on the Mixed Ratio and Dewaterability of Municipal Wastewater Sludge (도시하수 슬러지의 혼합비율자 탈수성에 관한 연구)

  • 이재운;김상훈
    • Journal of environmental and Sanitary engineering
    • /
    • v.8 no.1
    • /
    • pp.117-127
    • /
    • 1993
  • When incineration method is utilized as a disposal process of sludge, the treatment generally consists of thickening, dewatering and incineration, implying that sludge dewaterability has a colose relationship with operating condition of a thickener. Dewatering factors should be, therefore investigated for achieving effective sludge treatment. No research on this has been performed in Korea. This study has focused on the evaluation on the effects of thickener operating variables on sludge dewatering, including sludge feed types and retention time. Mixing ratio of the first and the second sludge and operation time were varied in order to observe the change of dewaterability and optimum input of chemical conditioner.

  • PDF

Strategy for efficient operation on the backwash waste treatment in membrane filtration water treatment plant (막여과 정수장 배출수처리시설의 효율적인 운영방안)

  • Jung, Wonchae;Yu, Youngbeom;Lee, Sunju;Moon, Yongtaik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.4
    • /
    • pp.479-489
    • /
    • 2014
  • Membrane backwashing waste shows seasonally different characteristics and it has bad settleability differently from general backwashing waste in water treatment plant. When chemicals was injected to membrane backwashing waste, the settleability was better than chemicals was not injected. However, when settled lower sludge was not discharged, flowing sludge continuously was concentrated over a certain surface and floatation penomena occurred according to flowing velocity. When the lower sludge was discharged continuously in the thickener to prevent floatation penomena of turbidity materials, the depth of sludge surface was the least and the settleability increased.

Dewatering Characteristic of Water Treatment Plant Sludges based on Detention Time (체류시간에 따른 정수장슬러지의 탈수특성)

  • Moon, Yong-taik;Kim, Byung-goon;Kim, Youn-kwon;Kim, Hong-suck
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.6
    • /
    • pp.709-715
    • /
    • 2007
  • The dewaterability of a sludge can be characterized by two ways: the residual moisture content in the sludge cake after dewatering process, and the filtration of the sludge. Time to filter (TTF) represents filtration processes that are special cases of the flow through a solid matrix concept. TTF characterizes a resistance to filtration. The sludge resistance, in turn, can be subdivided into resistances associated with the solid phase and the liquid phase to evaluate the effect of each of the two phases on sludge dewaterability. In order to determine the dewatering characteristics of the water sludge samples, TTF and zeta potential were measured. For these studies cationic polymer was chosen for water sludge dewatering experiments. The zeta potential of thickener sludges neared from minus values to zero values till 4 days after sampling. The dewaterability of thickener sludges using cationic polymer was deteriorated according to the increase of detention time. As the detention time was increased from 4 to 10 days, the optimal dose of the polymer was increased from 4 to 8mg/L. Therefore, the optimal detention time plays an important part for the dewaterability of a sludge.

The Aeration to Improve Manganese and Chloroform of Effluent at Sludge Thickener of the Conventional Water Treatment Plant (정수장 슬러지 폭기가 방류수 망간 및 클로로포름에 미치는 영향)

  • Choi, Ilgyung;Beak, Inho;Jeong, Chanwoo;Lee, Sungjin;Park, Jungwook
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.2
    • /
    • pp.113-118
    • /
    • 2014
  • So many nationwide drinking water treatment plants are under much difficulties by new reinforced discharged effluent standards. Generally, the sludge at thickener should be retended for a long time during usual days. Sometime, the soluble manganese and chloroform may be formed under the anaerobic condition in the sludge thickener when the sludge retention time is longer with low turbidity. This phenomenon results in difficulties to keep regulatory level of the discharged effluent. It was necessary to improve the operation conditions and process itself in order to meet water quality standard recently reinforced. For an effort to overcome the problems, a sludge aeration was successfully implemented into the thickening process. Sludge aeration prevent particle oxidated Manganese eluting soluble de-oxidated Manganese, excrete formated Chloroform from effluent to air, and improve sludge settling through homogenized sludge particle. We aerated sludge at the conventional water treatment plant, measured Manganese and Chloroform of clarified water at upper sludge, and solid-fluid interface height of sludge in mass cylinder. As a result, contaminant's concentrations of the final effluent was much decreased : 41% of manganese, approximately 62% of chloroform and 35% of sludge volume, compared with non-aeration sludge.

Analysis of laboratory scale nitriation reactor using sludge thickener supernatant (농축조 상징액을 대상으로한 실험실 규모 아질산화 반응조 분석)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.17 no.4
    • /
    • pp.414-420
    • /
    • 2015
  • Nitrogen is one of main causes to induce eutrophication of water system and one of contaminants that must be treated for protection of water system. In this study, it was intended to identify a method to increase operation efficiency of municipal wastewater treatment plant (MWTP) by treating high concentration nitrogen. A laboratory scale reactor was operated by using sludge thickener supernatant in the MWTP. During operation of the laboratory scale reactor, it was intended to induce stable nitritation and analyze effects of related operation factors. As results, it was shown that the nitiritation could be induced artificially through control of retention time and sections where the stable nitiritation was induced were identified also. In particular, highly efficient nitrite conversion efficiency near 90% was identified in condition of 1 day retention time. Especially, it was shown that ammonium nitrogen load affected ammonium nitrogen removal efficiency and nitrite conversion efficiency. In the condition of high ammonium nitrogen load, the nitrite conversion efficiency and the ammonium nitrogen removal efficiency decreased. On the contrary in the condition of low ammonium nitrogen load, it was found that the nitrite conversion efficiency decreased. It means that control of ammonium nitrogen concentration and its retention time is needed for the nitritation. It is considered that for the sewage containing high load nitrogen in sludge treatment process as like the sludge thickener supernatant, the nitritation can be applied, which can be suggested as a modification method of MWTP.

Papermill Wastewater Treatment by Indirect Aerated Submerged Biofilter (호기성 침지여상에 의한 제지폐수처리)

  • Won, Chan-Hee;Kwon, Young-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.8 no.1
    • /
    • pp.44-52
    • /
    • 1994
  • The purpose of this experimental research was focused to improve the quality of the effluent and the yielded sludge when the papermill wastewater was treated by the indirect aerated submerged biofilter as a second treatment method of papermill wastewater. Changing the various experimental factors(Nutrient additions or not, HRT, F/M ratio, recirculation ratio, etc) with indirect aerated biofilter, the results obtained are as follows. 1. Because of the microbes concentration could be sustained to $9,000mg/l$ in submerged biofilter and then the volumetric organic loads could be increased to $2.7kg-BOD/m^3/day$(that of activated sludge is $0.8kg-BOD/m^3/day$), the reactor volume can be reduced to one third of the activated sludge treatment. 2. Because of the yield coefficient(Y) and the endogenous decay coefficient(kd) were revealed 0.4 and 0.07/d, the yielded sludge volume was reduced by for compared with that of the activated sludgg process. 3. The concentration of the sloughed sludge in the reactor was 2.62~4.01%, so the thickener could be omitted in the papermill wastewater sludge treatment process. 4. When the operating was conducted at HRT of 4hrs, the treatment efficiencies of BOD and COD were obtained 80% and 70%, Therefore operating time can be reduced to one half of the activated sludge treatment.

  • PDF

Improvement of treatment efficiency for sanitary treatment facilities by process modifications (분뇨처리장의 공정개선에 의한 처리효율 향상에 관한 연구)

  • Lee, Chan Won;Kim, Seung Hyeon;Kim, Chang Su;Mun, Seong Won;Jeon, Hong Pyo;Yun, Jong Seop
    • Journal of Environmental Science International
    • /
    • v.13 no.6
    • /
    • pp.571-579
    • /
    • 2004
  • There is a need to improve the efficiency of the existing sanitary treatment facilities, because the effluent standard becomes more stricter and septic sludge increased. Thus, operating processes of sanitary treatment system in M city changed with installation of additional facilities. Process modifications were as follows: Dilution water was added to the next process after primary aeration tank. Some secondary sedimentation sludge was recycled to primary aerator so that most of the organics were stabilized in primary aeration tank under automatic control of dissolved oxygen. The line of effluent from dewatering process flowing to the activated sludge tank was changed to the primary aerator. The primary sedimentation sludge line was linked to a thickener. Polymer was added to the activated sludge tank. The effluent of primary aerator and aerobic digester was recycled from the 5th to the 1st sector. As consequencies of above process modifications, the improvement of removal efficiency was achieved as BOD 54%, COD 42%, SS 61%, T-N 39%, and T-P 12%, respectively.