• 제목/요약/키워드: Sludge settling

검색결과 110건 처리시간 0.024초

OSA 공정을 이용한 하수슬러지 감량화 및 질소제거 가능성 평가 (Estimation of Sludge Reduction and Nitrogen Removal Possibility using OSA Process)

  • 주재영;윤수철;남덕현;박철휘
    • 상하수도학회지
    • /
    • 제22권5호
    • /
    • pp.497-503
    • /
    • 2008
  • The Oxic-Settling-Anaerobic(OSA) process is a modified activated sludge processes for sludge reduction. It is evaluated that the sludge production in OSA process can decrease to 88% because of biomass decay and kinetic parameter($Y_H$ 0.237mgVSS/mgCOD, $b_H$ $0.195d^{-1}$) in anaerobic reactor, when compared with CAS process. However, it has problems caused by sludge reduction such as increase of nutrient loading. In case that the anoxic condition through the introduction of the intermittent aeration for the enhancement of nitrogen removal ability build up and enough rbCOD is suppled, maximum 88% of nitrogen is removed in the OSA process. If the OSA process optimizing the intermittent aeration cycle is applied to the separate sewage system with high rbCOD fraction, it can be converted to advanced process in terms of the sludge reduction and nitrogen removal, simultaneously.

Influence of sludge solids content on sludge dewaterability using bioleaching

  • Wong, Jonathan W.C.;Zhou, Jun;Zhou, Lixiang;Kurade, Mayur B.;Selvam, Ammaiyappan
    • Advances in environmental research
    • /
    • 제3권3호
    • /
    • pp.199-206
    • /
    • 2014
  • Dewatering is an extremely important step in wastewater treatment process to reduce the final sludge volume in order to minimize the cost of sludge transportation and disposal. In the present study, the effect of different sludge solids content (1, 2 and 3.8%) on the dewaterability of anaerobically digested sludge using Acidithiobacillus ferrooxidans and Acidithiobacillus thiooxidans was studied. The pH reduction rate was higher during initial process in the sludge having low solids content, but after 48 h of bioleaching, similar pH of below 3 was observed with all the different solids content. Bio-oxidation rate of $Fe^{2+}$ was initially higher in sludge with low solids content, but 100% $Fe^{2+}$ was oxidized within 60 h in all the three treatment levels. Compared to the control, specific resistance to filtration was reduced by 75, 78 and 80% in the sludge with a solids content of 1, 2 and 3.8% respectively, showing improvement in dewaterability with an increase in sludge solids content. Sludge effluent quality and sludge settling rate were also improved in treatments with higher solids content after the bioleaching process.

호기성 그래뉼 슬러지를 이용한 축산폐수의 생물학적 처리에 관한 연구 (Biological Treatment of Livestock Wastewater using Aerobic Granular Sludge )

  • 김현구;안대희
    • 한국환경과학회지
    • /
    • 제32권7호
    • /
    • pp.483-492
    • /
    • 2023
  • In this study, the treatment of livestock wastewater using an aerobic granular sludge based sequencing batch reactor was investigated. The reactor operation was carried out by general injection and split injection methods. The average removal efficiency of organic matter after the adaptation period was 71.5 and 87.4%, respectively. Some untreated organic matter was attributed to recalcitrant organic matter. The average removal efficiency of total nitrogen was 65.6 and 88.4%, respectively. These results indicate that the denitrification reaction by split injection was carried out smoothly. As for the solids, the ratio of aerobic granular sludge/mixed liquor suspended solid can be determined as the main factor of the process operation, and the ratio increased gradually and finally reached 86.0%. Correspondingly, the sludge volume index (SVI) was also improved, reaching 54 mL/g at the end of operation, and it is believed that the application of a short settling time contributed to the improvement of settleability.

전해부상을 이용한 활성슬러지의 탈수성 향상 (Improvement of Activated Sludge Dewaterability by Electro-flotation)

  • 최영균;박병주;박민정;김윤중;정태학
    • 상하수도학회지
    • /
    • 제20권5호
    • /
    • pp.677-684
    • /
    • 2006
  • Electro-flotation(EF), a novel sludge thickening method, could improve the dewaterability of activated sludge. The gas(microbubbles) generated during EF decreased the solid-liquid separation time below 1/5 of the time required for gravity sedimentation. In addition, over 90% of the sludge volume reduction could be achieved by EF although the settling characteristics of the sludge was very poor. The SRF(specific resistance to filtration) of the thickened sludge by EF was much lower than that of the sludge thickened by gravity sedimentation. The SRF of the thickened sludge decreased exponentially with increase of gas generation rate of the EF system. Gas generation rate could be controlled by varying the current density of the electrode. Degasing of the microbubbles by vigorous mixing of the thickened sludge layer deteriorated the dewaterability of the sludge. Therefore, it is obvious that the gas bubbles entrapped in the thickened sludge play a key role in the observed dewaterability improvement.

Treatment of Saline Wastewater by the Activated Sludge with Nonwoven Fabric Separation

  • Moon, Byung-Hyun;Heo, Jong-Soo;Choi, Hyoung-Sub
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제2권2호
    • /
    • pp.136-140
    • /
    • 1997
  • Direct membrane separation using nonwoven fabric was applied to saline wastewater treatment by an activated sludge process. A nonwoven fabric module was immersed in an aeration tank. The part of treated was filtered through the module by suction and the rest of that was separated by a settling tank. Various F/M ratios and salt concentrations were applied to investigate stable flux as well as pollutant removal. The pollutant removal efficiencies of nonwoven fabric separation was not affected by F/M ratios and salt concentrations and was higher than that of settling tank separation. The decline in flux was seemed to be caused by the biofilm on nonwoven fabric surface.

  • PDF

탄산칼슘-물 이성분계 슬러리의 침강 특성을 이용한 반연속식 침전탑의 실험적 해석에 관한 연구 (A Study on Experimental Analysis of Semi-Continuous Settling Tank using Characteristics of Solid Sedimentation in the Binary $CaCO_3$-Water Slurry)

  • 안원술;노승백;김정배;박상원;최창균
    • 한국환경과학회지
    • /
    • 제7권5호
    • /
    • pp.659-667
    • /
    • 1998
  • In the present paper, batch and semi-continuous settling characteristics of a binary calcium carbonate-water system were investigated. Using experimental data of batch settling characteristics, a graphical analysis for a semi-continuous thickening column was developed and compared with experimental results on the basis of Kynch theory, only where the feed velocity line was within the limits of Kynch theorem III. The analysis showed good agreement with experiments. Quite erroneous results, however, was observed for the analysis of a sludge region on the underloaded operation, which was considered due to the deviation from the limits of theory.

  • PDF

도시하수슬러지의 혐기성소화시 고액분리 특성에 미치는 소화온도의 영향 (Effect of Digestion Temperature on the Solid-Liquid Separation Characteristics of Anaerobically Digested Municipal Sewage Sludge)

  • 한장운;장덕;김성순
    • 상하수도학회지
    • /
    • 제8권1호
    • /
    • pp.1-8
    • /
    • 1994
  • Laboratory experiments were conducted to investigate the effect of digestion temperature on the settleability and dewaterability of anaerobically digested sludge. The digesters were operated at a hydraulic retention time of 20 days with a loading rate of 0.63~0.66kg volatile solids per cubic meter per day at the temperature of $35^{\circ}C$ and $55^{\circ}C$. A mixed primary and secondary municipal sludge was used as a feed. The interface height of the sludge during settling test was recorded to identify settleability. As a measure of dewaterability of the sludge, specific resistance and capillary suction time were also measured with and without chemical conditioning. Higher digestion efficiency was obtained at $55^{\circ}C$ than $35^{\circ}C$. However, the settleability and dewaterability of the sludge at $35^{\circ}C$ were quite higher than those of the sludge digested at $55^{\circ}C$. The optimum dosages of ferric chloride for sludge conditioning were 0.4% and 0.6% at $35^{\circ}C$ and $55^{\circ}C$, respectively. The filtrate COD of the sludge digested at $55^{\circ}C$ was higher than at $35^{\circ}C$, which means that poor dewaterability of the sludge result in high filtrate COD.

  • PDF

미생물배양조를 결합한 회전원판법에 의한 하수처리 효과 (The Effect of Wastewater Treatment by Rotating Biological Contactors with HBR)

  • 임봉수;어성욱;정원문
    • 한국물환경학회지
    • /
    • 제16권4호
    • /
    • pp.501-512
    • /
    • 2000
  • This study was carried out to develop the new process for RBC process which is capable of nutrient removal and to obtain its design parameters for Sludge Settling Type Rotating Biological Contactors by comparing RBC with RBC combined with HBR (Hanmee Bio-Reactor). To achieve more than 90% of organic removal efficiency, organic loading rate less than $6.0g\;BOD/m^2/d$ is recommended. Nitrification rate was about 90% at $6.0g\;BOD/m^2/d$. TN removal efficiency of RBC+HBR was higher than those of RBC1 and RBC2. TN removal efficiency at condition of $5.0g\;BOD/m^2/d$ was about 60% in RBC1. When BOD loading rate was $6.0g\;BOD/m^2/d$. TN removal efficiencies in RBC2 and RBC+HBR were about 70%, 80%, respectively. TP removal efficiency was more than about 67% for RBC1, about 63% for RBC2 and about 71 % for RBC+HBR at the same loading rate. From the blank experiment to observe removal efficiency in the first stage, it can be known that COD removal efficiency was about 30% and suspend solids settling rate was about 45%. It was proved that RBC+HBR is much better in sludge dewatering than RBC.

  • PDF

하수처리 공법별 네오하이드로포일 교반기의 적용 특성 및 효과 (Characteristic Features and Effect of Neo-Hydrofoil Impeller Applied in Sewage Treatment Plants)

  • 주윤식;손건태;배영준;이승환
    • 상하수도학회지
    • /
    • 제30권2호
    • /
    • pp.187-196
    • /
    • 2016
  • In this study, a newly developed agitator with hydrofoil impeller applied to actual biological process in advanced wastewater treatment plant was evaluated. Several series of experiments were conducted in two different wastewater treatment plants where actual problems have been occurred such as the production of scums and sludge settling. For more effective evaluation, computational fluid dynamics (CFD) and measurements of MLSS (Mixed Liquor Suspended Solids) and DO (Dissolved Oxygen) were used with other measuring equipments. After the installation of one unit of vertical hydrofoil agitator in plant A, scum and sludge settling problems were solved and more than seventy percent of operational energy was saved. In case of plant B, there were three cells of each anoxic and anaerobic tanks, and each cell had one unit of submersible horizontal agitator. After the integration of three cells to one cell in each tank, and installation of one vertical hydrofoil agitator per tank, all the problems caused by improper mixing were solved and more than eighty percent of operational energy was found to be saved. Simple change of agitator applied to biological process in wastewater treatment plant was proved to be essential to eliminate scum and sludge settling problems and to save input energy.

An aerobic granular sludge process for treating low carbon/nitrogen ratio sewage

  • Yae, JaeBin;Ryu, JaeHoon;Tuyen, Nguyen Van;Kim, HyunGu;Hong, SeongWan;Ahn, DaeHee
    • Environmental Engineering Research
    • /
    • 제24권2호
    • /
    • pp.238-245
    • /
    • 2019
  • This study investigated the characteristic of aerobic granular sludge (AGS) process to treat the sewage having low carbon/nitrogen ratio (Biochemical oxygen demand ($BOD_5$):Total nitrogen (T-N), 4.5:1) in sequencing batch reactor (SBR). The removal efficiency of $BOD_5$, suspended solid (SS), T-N and phosphorus ($PO_4{^{3-}}$-P) were 92.6%, 64.3% and 90.1%. Concentration and size of AGS were changed in proportion to the organic matters and nitrogen concentration of the influent (Concentration and size of AGS: 1,700-3,000 mg/L, 0.5-1.0 mm). Mixed liquor suspended solid (MLSS) also changed with the concentration of AGS (MLSS: 2,000-3,500 mg/L). When the settling time was shortened from 15 min to 10 min, size and shape of AGS were maintained (Size of AGS: 1.0-1.5 mm). In addition, the concentration of AGS and MLSS increased (Concentration of AGS: 3,500 mg/L, MLSS: 4,000 mg/L). Concentration, size and shape of AGS were affected the settling time of the reactor more than the concentration of organic matter and nitrogen in the influent. In the results of removal efficiency and changes in AGS, we confirmed that the SBR process using AGS can be used to treat the sewage having low carbon/nitrogen ratio by applying short settling time.