• Title/Summary/Keyword: Sludge retention time

Search Result 168, Processing Time 0.03 seconds

Organic Matter Degradation and Nitrification Characteristics in Aerobic Digestion of Sewage Sludge (슬러지 호기성 소화공정에서의 유기물 분해 및 질산화 특성)

  • Hwang, Eung-Ju
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.10
    • /
    • pp.865-872
    • /
    • 2009
  • Continuous operation of aerobic sludge digestion reactor was attempted for 279 days. Anaerobic digester sludge, the target material of the experiment, was pretreated by sodium hydroxide at $40^{\circ}C$ for 120 minutes, and the pretreated sludge was fed to 5 L CSTR (continuous stirred tank reactor). Reactor performance was affected by properties of input sludge and HRT (hydraulic retention time). 6 days of HRT showed best and stable performance, and under this condition, removal rates of $NH_3$-N, SCOD, TKN, TCOD, SS, and VSS were 97.4%, 81.7%, 68.7%, 61.4%, 50.6%, and 47.0%, respectively. 73.9% of SS in anaerobic digester sludge was reduced by pretreatment and aerobic digestion. Effluent sludge had low soluble COD of 350 mg/L. This implied the sludge was stabilized and suitable for use as liquid fertilizer. Nitrification took place when HRT was higher than 4 days. $NO_3$-N concentration was as high as 658 mg/L while $NH_3$-N was as low as 20 mg/L.

The effect of zeolite addition on floc in activated sludge process (제올라이트 주입이 활성슬러지 플럭에 미치는 영향)

  • Lee, Hyung Sool;Park, se Jin;Yoon, Tae Il
    • Clean Technology
    • /
    • v.7 no.1
    • /
    • pp.35-42
    • /
    • 2001
  • This study was performed to evaluate the effect of zeolite addition on biofloc in aictvated sludge process. Two units were compared each other, in which one was operated as control unit (CU) and the other was managed by adding zeolite into aeration basin to sustain 4,000 mg/l (ZU). It was observed that flocs of both units were enduringly increased in medium size by extending SRT (Solid Retention Time), although their effect size of ZU was smaller than theirs of CU. Zeolite application excessively improved sludge settling property and ZU presented sludge settling velocity of 3.4 to 11 m/h regardless of SRT variation. The sludge volume index (SVI) was in the range of 50 and 108 ml/g. Conversely, the sludge settling velocity of CU seriously depended on SRT increase, and sludge sedimentation was not achieved at a 40 days of SRT due to Sphaerotilus appeared predominantly in reactor.

  • PDF

Removal of Nutrients from Domestic Wastewater Using Intermittently Aerated Activated Sludge Systems Supplemented with Fermented Settled Sludge (발효된 1차 침전슬러지를 공급하여 간헐폭기조를 이용한 도시하수의 영양염류 처리)

  • Weon, Seung-Yeon;Lee, Sang-Ill
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.1
    • /
    • pp.18-23
    • /
    • 2004
  • In this research, a 2-stage intermittently aerated activated sludge system(IA) and intermittently aerated dynamic flow activated sludge system(DF) were investigated for the removal of nutrients in domestic wastewater. Wastewater was characterized by low C/N( organics/nitrogen) ratio. $COD_{cr}$, $BOD_s$, TKN and TP concentrations of domestic wastewater were 235, 47, 32 and 5.4 mg/L, respectively. Three sets of IA and one set of DF were operated. Three of four systems were added with fermented settled sludge taken from primary settling tank as an external electron donor and the other(IA) for control reactor was operated without addition of electron donor. All systems were operated at same sludge retention time of 20 days and hydraulic retention time of 12hrs. The supplemental electron donor was supplied into the anoxic mode. A higher denitrification rate was observed from the reactors with fermented settled sludge as an electron donor for denitrification compared to that of without addition of organic source. The result of this study indicates that the settled primary sludge, if the fermented at the acid stage, was an excellent electron donor for denitrification. 81 % of TN and 80% of TP were removed from the systems with the supplemental organic source added. However, the control reactor without addition of electron donor showed only 39% of TN and 43% of TP.

A Study on the Thermal Solubilization Characteristics of Highly Thickened Excess Sludge in Municipal Wastewater Treatment Plant (하수처리장에서 발생하는 고농축 잉여슬러지의 열적가용화 특성에 관한 연구)

  • Kim, Eunhyuk;Park, Myoung Soo;Koo, Seulki
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.30 no.4
    • /
    • pp.5-13
    • /
    • 2022
  • The current environmental problem is that environmental pollution is accelerating due to the generation of large amounts of waste and indiscriminate consumption of energy. Fossil fuels, a representative energy production fuel, are burned in the process of producing energy, generating a large amount of greenhouse gases and eventually causing climate change. In addition, the amount of waste generated worldwide is continuously increasing, and environmental pollution is occurring in the process of waste treatment. One of the methods for simultaneously solving these problems is the energy recovery from and reduction of organic wastes. Sewage sludge generated in sewage treatment plants has been treated in various ways since ocean disposal was completely prohibited, but the amount generated has been continuously increasing. Since the sewage sludge contains a large amount of organic materials, it is desirable to recover energy from the sewage sludge and reduce the final discharged waste through anaerobic digestion. However, most of the excess sludge is a mass of microorganisms used in sewage treatment, and in order for the excess sludge to be anaerobically digested, the cell walls of the microorganisms must be destroyed first, but it takes a lot of time to destroy the cell walls, so high rates of biogas production and waste reduction cannot be achieved only by anaerobic digestion. Therefore, the pre-treatment process of solubilizing excess sludge is required, and the thermal solubilization process is verified to be the most efficient among various solubilization methods, and high rates of biogas production and waste reduction can be achieved by anaerobic digestion after destroying cell walls the thermal solubilization process. In this study, when pretreating TS 10% thickened excess sludge through a thermal solubilization system, a study was conducted on solubilization characteristics according to retention time and operating temperature variables. The experimental variables for the retention time of the thermal solubilization system were 30 minutes, 60 minutes, 90 minutes, and 120 minutes, respectively, while the operating temperature was fixed at 160℃. The soulbilization rates calculated through TCOD and SCOD derived from the experimental results increased in the order of 12.11%, 20.52%, 28.62%, and 31.40%, respectively. And the variables according to operating temperature were 120℃, 140℃, 160℃, 180℃, and 200℃, respectively, while the operating retention time was fixed at 60 minutes. And the solubilization rates increased in the order of 7.14%, 14.52%, 20.52%, 40.72%, and 57.85%, respectively. In addition, TS, VS, T-N, T-P, NH4+-N, and VFAs were analyzed to evaluate thermal solubilization characteristics of thickened excess sludge. As a result, in order to obtain 30% or more solubilization rate through thermal solubilization of TS 10% thickened excess sludge, 120 minutes of retention time is required when the operating temperature is fixed to 160℃, and 170℃ or more of operating temperature is needed when the operating time is fixed to 60 minutes.

Effect of Digestion Temperature on the Solid-Liquid Separation Characteristics of Anaerobically Digested Municipal Sewage Sludge (도시하수슬러지의 혐기성소화시 고액분리 특성에 미치는 소화온도의 영향)

  • Han, Jang Woon;Chang, Duk;Kim, Sung Soon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.8 no.1
    • /
    • pp.1-8
    • /
    • 1994
  • Laboratory experiments were conducted to investigate the effect of digestion temperature on the settleability and dewaterability of anaerobically digested sludge. The digesters were operated at a hydraulic retention time of 20 days with a loading rate of 0.63~0.66kg volatile solids per cubic meter per day at the temperature of $35^{\circ}C$ and $55^{\circ}C$. A mixed primary and secondary municipal sludge was used as a feed. The interface height of the sludge during settling test was recorded to identify settleability. As a measure of dewaterability of the sludge, specific resistance and capillary suction time were also measured with and without chemical conditioning. Higher digestion efficiency was obtained at $55^{\circ}C$ than $35^{\circ}C$. However, the settleability and dewaterability of the sludge at $35^{\circ}C$ were quite higher than those of the sludge digested at $55^{\circ}C$. The optimum dosages of ferric chloride for sludge conditioning were 0.4% and 0.6% at $35^{\circ}C$ and $55^{\circ}C$, respectively. The filtrate COD of the sludge digested at $55^{\circ}C$ was higher than at $35^{\circ}C$, which means that poor dewaterability of the sludge result in high filtrate COD.

  • PDF

Biological Treatability of Toxic Industrial Wastewater (독성산업폐수의 생물학적 처리)

  • 원성연;박승국;정근욱
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.4
    • /
    • pp.172-179
    • /
    • 1999
  • In this research, biological treatability test was conduced using seawater flocculated tannery wastewater by fixed biofilm reactor. During one cycle, the removal efficiency of organic corbon obtained with fixed biofilm process for treating tannery wastewater was considerably greater than that with activated sludge process. As the hydraulic retention time increased form 0.5day to 4day, removal efficiency of organic carbon was increased from 72% to 87.3%. Attached biomass in media increased with influent organic loading up to 29g MLSS/L, that could reduce the specific organic loading rate. The continual measurement of attached biomass was possible for the operation of the biofilm reactor. Equal and low nitrication rates were observed in both suspended growth activated sludge process and fixed biofilm process, despite commercial nitrifier was seeded. Through the process of treating the tannery wastewater, EC50 values which is measured by the use of Ceriopdaphnia dubia, were decreased to the extent of 50% after treatment of seawater flocculation and of 83% after biological treatment, respectively, compared to those of the untreated wastewater.

  • PDF

Nitrogen Removal from ADEPT Effluent of Piggery Wastewater using Nitritation/Denitiritation System (ADEPT공정을 거친 돈사폐수의 아질산화-아탈질 공정을 이용한 질소제거)

  • Lee, Hwa-Sun;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.134-139
    • /
    • 2006
  • Partial nitirification and denitrification process has been reported to be technically feasible and economically favorable, especially for wastewater treatment with high ammonium concentration or low Carbon/Nitrogen ratio. This research was performed to survey nitrite accumulation by nitritation in treating ADEPT effluent of piggery wastewater, which contains highly concentrated ammonia. To estimate the possibility of nitrite accumulation, DO concentration and SRT were investigated as key operational parameters. This result proved that nitritation to nitrite was steadily obtained under short sludge retention time. Oxygen limitation was proved to be just a subsidiary parameter. Energy efficiency of nitritation-denitritation process was higher than complete nitrification-denitrification because external carbon requirement for denitritation could be saved. Though the influent contained significant nonbiodegradable organic substrate, total nitrogen removal efficiency was more than 51% in nitritation-denitritation system.

A Study on Factors Affecting Anaerobic Digestion of Waste Activated Sludge (活性슬러지의 嫌氣性消化에 미치는 影響因子에 관한연구)

  • 최홍복;황경엽;김윤신
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.1
    • /
    • pp.28-33
    • /
    • 1997
  • This study was carried out to investigate factors affecting anaerobic digestion enhancement of waste activated sludge(WAS). In order to this investigation, the degradability and rupture of microorganisms cell present in WAS, and mesophilic anaerobic digestion(MAD) of these compounds, were also evaluated. The micro-organisms cell in WAS were ruptured by a mechanical jet stream and smashed under pressure of 30 bar. The rupture level of micro-organisms cell in WAS were determined using phosphate, soluble protein and soluble chemical oxygen demand (SCOD)concentrations. It was found that the rupture level of micro- organisms cell within WAS increased with increasing pretreatment times, and the pretreated WAS once under pressure of 30 bar resulted in an increase in VS removal and methane production of 5%, 9% over the intact WAS of 35%, 71%, respectively, in batchwise MAD of 6-day and 14-day retention time. With the pretreatment and MAD of 6-day retention time used, mesophlic bioconvertibility as the biogasification of WAS were found to be significantly higher biogas of 1, 850 ml than 300 ml under intact WAS. In conclusion it can be stated mechanical pretreatment enhances WAS bioconvertibility, while under identical treatment conditions, resulted in a considerable decrease in the bioconvertibility of intact WAS.

  • PDF

Treatability Study on the SepticTAnk Sludges

  • Byung Soo Yang
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.17 no.1
    • /
    • pp.41-47
    • /
    • 1981
  • The characteristics of septic tank sludges were investigated and the kinetic coefficients in the aerobic biodegradation were evaluated from bach treatability tests. Using an unbiased statistical method, the estimated values, k (substrate removal rate coefficient) =0. 0175hr-1 at 17\ulcornerC, K. (Michaelis Menten constant) = 248mg/ e, a (cell yield coefficient)=0.625, and Kd (cell decay coefficient:' =0. 00192hr-1 were obtained based on biodegradable COD(mg/ \ulcorner) and volatile suspended solids(mg/\ulcorner). The relationship between COD and BOD, COD (mg/\ulcorner) =2. 1 BOD(mg/\ulcorner) +250, also was established for the septic tank sludges. Dilution was inevitable for the grit removal because of the high viscosity of the sludges. An aerobic activated sludge process rather than anaerobic processes was recommended for the removal of soluble organics after the removal of grit and suspended solids. A multi-stage activated sludge process was adapted for this highly concentrated and not easily-degradable waste. It was estimated that a four-stage activated sludge process would require 40 hours retention time compared to 92 hours for a single-stage process, 52 hours for a double-stage process, and 46 hours for a three stage process in order to achieve an effluent quality of 84mg/ e COD( 40mg/ e BOD) with about 4, OOOmg/ \ulcorner MLSS from an influent quality of I, 500mg/ t COD(714mg/.e BOD), while multi-stages beyond four stage would not save the required retention time significantly.

  • PDF