• Title/Summary/Keyword: Sludge Suction

Search Result 43, Processing Time 0.031 seconds

Flow Analysis of the Rotating Sludge Suction Collector by Numerical Simulation (수치시뮬레이션을 이용한 흡입식 슬러지 수집기의 유동해석)

  • Suh, Sang-Ho;Roh, Hyung-Woon;Byun, Jong-Youn
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.5 s.38
    • /
    • pp.22-27
    • /
    • 2006
  • Sedimentation phenomenon of suspended solids occurs by the gravitational force. Pollution particles are separated from slowly flowing waste water in clarifier. Recently, the sludge suction collector is Preferred rather than the scraper type sludge collector due to the enhancement of the clarifier efficiency. The sludge suction collector is usually operated by the user's experiences without any scientific and/or technical consideration. To evaluate the performance of sludge suction collector, the three dimensional numerical simulation was conducted by the finite volume method. To analyze the performance, the velocity vectors and the suction flow rates of the orifices were investigated. The result showed that each suction flow rate through out the collector was equivalent in the sludge suction collector and the efficiency of suction collector was good to remove high concentrated sludge in clarifier.

Variation of Flow Characteristics in the Rotating Suction Sludge Collector (흡입식 슬러지 수집기가 회전할 때의 유동특성 변화)

  • Jin, Hee-Nam;Byun, Jong-Youn;Roh, Hyung-Woon;Suh, Sang-Ho
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1851-1856
    • /
    • 2004
  • Sedimentation phenomenon of suspended solids occurs by the gravitational force. Pollution particles are separated from slowly flowing wastewater in clarifier. Recently, the sludge suction collector is preferred rather than the scraper type sludge collector due to enhancement of the clarifier efficiency. The sludge suction collector is usually operated by the user's experiences without any scientific and/or technical consideration. To evaluate the performance of sludge suction collector, the three dimensional computer simulation was conducted by the finite volume method. To analyze the performance, the velocity vectors and the suction flow rates of the orifices were investigated. The result showed that each suction flow rate through out the collector was equivalent in the sludge suction collector and the efficiency of suction collector was good to remove high concentrated sludge in clarifier.

  • PDF

Performance Analysis for Sludge Suction Collector in Clarifier (침전지의 흡입식 슬러지 수집기에 대한 성능해석)

  • Jin, Hee-Nam;Byun, Jong-Youn;Suh, Sang-Ho;Roh, Hyung-Woon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.415-420
    • /
    • 2003
  • Sedimentation phenomenon of suspended solids occurs by the gravitational force. Pollution particles are separated from slowly flowing wastewater in clarifier. Recently, the sludge suction collector is preferred rather than the scraper type sludge collector due to enhancement of the clarifier efficiency. The sludge suction collector is usually operated by the user's experiences without any scientific and/or technical consideration. To evaluate the performance of sludge suction collector, the three dimensional computer simulation was conducted by the finite volume method. To analyze the performance, the velocity vectors and the suction flow rates of the orifices were investigated. The result showed that each suction flow rate through out the collector was equivalent in the sludge suction collector and the efficiency of suction collector was good to remove high concentrated sludge in clarifier.

  • PDF

Optimal Design on a Channel of Rectangular Suction Sludge Collector and the Flow Characteristics of Wastewater (장방형 흡입식 슬러지 수집기에서 수로의 최적설계 및 폐수 유동특성)

  • Yong, Jung-Kwon;Choi, Chung-Ryul;Kim, Chang-Nyung
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1034-1039
    • /
    • 2008
  • Recently, the sludge suction collector is preferred rather than the scraper type sludge collector due to enhancement of the clarifier efficiency. The sludge suction collector is usually operated by the user's experience without any scientific and technical consideration. There are many factors that should be considered for higher quality of discharged water and stabilized flow in the rectangular sludge suction collector but, the optimal design on the inflow channel and orifices connecting with the inflow channel is needed for similar flow rates at the orifices. The 4 cases of channel geometry are considered and mass flow rates of each case at the orifices are evaluated using Computational Fluid Dynamics applied VOF(Volume of Fraction) model.

  • PDF

Comparison of the Dewatering Characteristic Using Specific Resistance and Capillary Suction Time of Digested Sewage Sludge by Ultrasonic Treatment (초음파로 처리된 소화슬러지의 비저항계수 (SRF)와 모세관흡입시간(CST)을 이용한 탈수특성 비교)

  • Na, Seung-Min;Park, Ji-Ho;Kim, Young-Uk;Khim, Jee-Hyeong
    • Proceedings of the KAIS Fall Conference
    • /
    • 2007.05a
    • /
    • pp.287-290
    • /
    • 2007
  • We investigated the effect of ultrasound on the dewaterability of sewage sludge. Because, dewatering and disposal of waste sludge is a major economical factor in the operation of wastewater treatment plants. Capillary Suction Time(CST) and Specific Resistance to Filtration (SRF) were used to evaluate the sludge dewatering behaviors. From the results of the experiment, it was found that ultrasonic treatment can improve the dewaterability. We discovered that CST and SRF were highly related, according to the correlation coefficient($R^{2}$).

  • PDF

A Comparative Study on the Conditioning and Dewaterability of Digested Sludge from Intermittent Aerobic Digestion (간헐포기 소화슬러지의 개량과 탈수 특성에 관한 비교 연구)

  • Kim, Seong Hong;Choi, Young Gyun;Chung, Tai Hak
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.4
    • /
    • pp.370-375
    • /
    • 2004
  • Synthetic organic polyelectrolytes can be used to condition sludges to enhance their dewaterability. When conditioning biological sludges, the charge on the polymer has a significant impact on the effectiveness of the polymer as a conditioner. The objectives of this investigation were to determine the most effective type and dosage of polymer for conditioning digested sludge prior to dewatering, and to investigate the relationship between dewaterability and particle size. 3 types of digested sludge were used under the different digestion processes like anaerobic digestion, aerobic digestion and intermittent aerobic digestion. CST(capillary suction time), TTF(time-to-filter) and SRF(specific resistance to filtration) were tested as a dewaterability index and the number of particle distribution was analyzed using particle size analyzer. The results indicate that cationic polymer appears to be required for effective conditioning of these 3 types digested sludge and the optimal polymer dosage is about 0.6% of SS. CST and TTF are well correlated with mean particle diameter of which the dimension order is 1.7.

Development of Engineering Model for a Barge Moulted Seabed Sludge Treatment Plant (해저 오염 퇴적층 복원 처리를 위한 BMP 패키지 기술 개발)

  • 배준홍;하문근;어경해;김승혁;박찬후;김병우;구근회;윤철원
    • Journal of Ocean Engineering and Technology
    • /
    • v.17 no.2
    • /
    • pp.8-13
    • /
    • 2003
  • Soil, ground water, and sea bed are exposed to a continuous accumulation of polluted materials, causing serious environmental damage. It has been reported that such pollution causes a massive mortality of fish stock in rivers due to the resuspension of toxic chemicals, occurring during strong wind conditions. Therefore, it becomes apparent that there is an immediate demand for the restoration treatment of polluted river bed (or sea bed) sediment layers. Pollution levels of major rivers and ports, such as Paldang, Kyungan rivers, and Masan port, are becoming of great public concern, and are posing a serious environmental threat. In particular, the pollution of the Shi-hwa river has become a nation wide issue for the last few years. In spite of such public concern, the pollution levels of such rivers or ports are worsening everyday. In this study, an environmentally sound engineering package is introduced that helps to restore the polluted river bed or sea bed sediments. This engineering package consists of a suction facility, followed by a series of mechanical, chemical, and biological treatment units. The suction facility is designed to minimize secondary pollution that occurs from the resuspension of toxic materials during suction. The sea bed cleaning engineering package is designed to be installed on the top of a floating barge. Such a combination of environmental plant and shipbuilding technology provides a cost-effective solution, minimizing the transportation between suction and treatment facilities.

Optimum Operation of a PVDF-type Hollow Fiber Membrane Bioreactor for Continuous Sewage Treatment

  • Shin, Choon-Hwan
    • Journal of Environmental Science International
    • /
    • v.19 no.11
    • /
    • pp.1315-1322
    • /
    • 2010
  • A membrane bioreactor (MBR) was designed using polyvinylidene fluoride(PVDF)-type hollow fiber membrane modules with a treatment capacity of 10 ton/day. A pilot plant was installed in a sewage treatment plant and was operated with an intermittent aeration method which avoids any concentration gradient of suspended solids (SS) in the MBR. For continuous operation, the pilot plant was first tested with influent (mixed liquor suspended solid:MLSS of 1000-2000 mg/L) of aeration tanks in the sewage treatment plant. The MBR was pre-treated with washing water, 10% ethanol solution, 5% NaOCl solution and finally washing water, one after another. To demonstrate the effect of the MBR on sewage treatment, compared with conventional activated sludge processes, we investigated the relationships among permeate amount (LMH), change in operation conditions, influent MLSS level and sludge production. It was found that the optimum aeration rate and suction pressure were $0.3\;m^3$/min and 30~31 cmHg, respectively. Under stable conditions in aeration, suction pressure, influent flow rate and drainage, the SS removal efficiency was more than 99.99% even when the MLSS loading rate changes. Compared with conventional activated sludge processes, the MBR was more effective in cost reduction by 27% based on permeate amount and by 51.5% on sludge production.

Coupling Equation of Specific Resistance to Filtration(SRF) and Capillary Suction Time(CST) of Digested Sewage Sludge (소화슬러지의 비저항계수(SRF)와 모세관흡입시간(CST)의 상호관계식 유도 및 비교)

  • Khim, Jee-Hyeong;Na, Seung-Min;Park, Ji-Ho;Kim, Young-Uk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.4
    • /
    • pp.874-880
    • /
    • 2007
  • Capillary Suction Time(CST) and Specific Resistance to Filtration(SRF) were commonly used to evaluate the sludge dewatering behaviors. A coupled equation was developed through the mathematical theory which represented both CST and SRF as the physical filterability of the ultrasonically treated sludge. The model for coupling CST and SRF includes both equipment variables and variables related to sludge characteristics, and verified with the results from experiments. The results of the theoretical and experimental study showed that a good correlation relationship among dewaterability indices.

  • PDF

Dewaterability of the Municipal Wastewater Sludge Mixed with Livestock Sludge (축산 슬러지와 혼합된 도시하수슬러지의 탈수성)

  • Jo, Ji-Min;Choi, Min-Seok;Han, Young-Gyu;Kim, Yeong-Kwan
    • Journal of Industrial Technology
    • /
    • v.36
    • /
    • pp.83-88
    • /
    • 2016
  • In this study, a series of experiment was carried to improve dewaterability of the sludge produced in a treatment plant, located in Hongcheon, Gangwondo, which has been treating municipal wastewater and livestock wastewater. Optimum sludge mixing ratio and the amount of sludge conditioner were determined. As sludge conditioners, alum and ferric salt were selected and tested. For the measurement of sludge dewaterability, capillary suction time(CST) and the specific resistance were measured, The specific resistance was detemined by running a series of Buchner Funnel Test. Mixing the two sludges at a 50:50 ratio with the addition of 20 mL alum gave the best results in terms of dewaterability. The moisture content decreased by 2% at this condition.

  • PDF