• Title/Summary/Keyword: Slot line

Search Result 257, Processing Time 0.026 seconds

Microstrip Fed Meander Slot Antenna with Open-End for the RF Remote Controller (RF 리모컨용 마이크로스트립 급전 개방 종단을 갖는 미앤더 슬롯 안테나)

  • Jin, Jeong-Hi;Kim, Ui-Jung;Jang, Soo-Young;Lee, Young-Soon;Cho, Young-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.2 s.117
    • /
    • pp.143-150
    • /
    • 2007
  • A meander slot antenna with open-end fed by a microstrip line which can be used at 400 MHz ISM band is newly proposed. The main difference between the proposed slot antenna and the previous slot antenna is the introduction of the open-end to miniaturize the previous meander slot antenna in the space restricted within narrow limit. In order to check the validity of the proposed antenna, the resonant frequency and radiation pattern of the proposed antenna have been simulated and examined. Good agreements between simulated results and measured results have been observed.

Linear Tapered Slot Rectifying Antenna for Portable UHF-Band RFID System (휴대용 UHF대역 RFID 시스템을 위한 선형 테이퍼드 슬롯 정류 안테나)

  • Pyo, Seongmin
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.368-371
    • /
    • 2020
  • In this paper, we propose a linear tapered slot rectifying antenna for a portable UHF-band RFID system. Since the proposed rectifying antenna does not use a dielectric substrate, the planar antenna is implemented with a thin metal thickness. The rectifier circuit converts input RF power into output DC voltage using a voltage doubler circuit based on two anti-parallel schottky diodes. The rectifying antenna is integrated by the voltage doubler circuit into a linear tapered slot antenna. For conjugate impedance matching of the rectifying circuit and the linear tapered slot antenna, the source-pull method was utilized by adjusting the angle of the tapered slot and the length of the antenna feed line. The proposed antenna prototype has been verified with the electrical and radiation characteristics through RF-DC conversion and far-field radiation test in open space measurement environment. Finally, the proposed antenna is realized to 0.23-wavelength (75 mm) and 0.18-wavelength (60 mm) at 915 MHz center frequency.

Design of Wideband Low Pass Filter for Harmonic Suppression Applications (고조파 억제 응용을 위한 광대역 저역 통과 필터 설계)

  • Yeo, Junho;Lee, Jong-Ig
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.1
    • /
    • pp.169-174
    • /
    • 2018
  • In this paper, a design method for a wideband LPF for harmonic suppression applications is investigated. The proposed wideband LPF is comprised of four circular slot pairs with different diameters, which are added symmetrically in the ground plane of a CPW transmission line. Four circular slot pairs act as a defected ground structure and provide a wideband low pass characteristic. The circular slot with the smallest diameter is located at the side of port 1, and the diameter of the circular slot is increased as it goes toward port 2. The low pass characteristics of each circular slot are compared with the proposed wideband LPF. The final designed LPF was fabricated on FR4 substrate, and its characteristics were tested. The measured S11 characteristic was maintained at over -3.3 dB in the frequency range of 1.89-20.00 GHz band, whereas the S21 characteristic was less than -21.4 dB in the frequency range of 2.66-20.00 GHz.

Nacl Aqueous Solution Concentration Detection Using Slot-Coupled Capacitor Resonator (슬롯결합 커패시터 공진기를 이용한 Nacl 수용액 농도 검출)

  • Yun, Gi-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.11
    • /
    • pp.29-35
    • /
    • 2018
  • In this paper, we proposed a high sensitivity sensor that can detect the concentration change of Nacl aqueous solutions by using a slot coupling capacitor resonator in sub-microwave band. The resonator applied to the sensor consists of a parallel plate capacitor connected to an inductive slot utilizing the ground plane of the microstrip line. Based on the measurement data of the dielectric characteristics according to the concentration change, the resonance frequency was determined in the UHF band where the concentration change is evident and the Nacl aqueous solution is inserted into the capacitor. Based on the simulation, the proposed resonator was designed and fabricated. The concentration level was varied from 0 to 400 mg/dl as 100 mg/dl step, and the transmission scattering coefficient ($S_{21}$) was successfully measured. Experimental results show that it is applicable to the concentration detection sensor in Nacl aqueous solution by obtaining minimum 1.8 dB($S_{21}$) at each step.

On-line partial discharge measurement techniques of hydro-generator windings (수력 발전기 권선에서의 운전중 부분방전 측정기법)

  • 황동하;김진봉;김용주;박명수;김택수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.2
    • /
    • pp.294-300
    • /
    • 1996
  • In hydro-generator, a groundwall insulation of stator windings gradually deteriorates due to mechanical, thermal, electrical and environmental stresses. These stresses combine to result in loose windings, delamination of the stator insulation and/or electrical tracking of the endwinding, all of which can lead to stator insulation failures. Conventionally, off-line tests such as partial discharge measurement, DC/AC current and .DELTA.tan.delta. tests has been used for estimation of winding condition. However, off-line test requires large power supply and generator outage. In addition, major cause of insulation problems such as loose wedges and slot dischages may not be found with off-line diagnoses. This paper introduces the on-line partial discharge measurement techniques using frequency spectrum analyzer(FSA) for the generator stator windings. The experimental results from the UIAM #1 hydro-generator confirms a optimistic application of on-line generator diagnosis method as a reliable tool for evaluation of winding condition.

  • PDF

Off-Line and On-Line Partial Discharge Properties of Large Turbine Generator (대용량 터빈발전기 고정자 권선의 정지중 및 운전중 부분방전 특성)

  • Kim, Hee-Dong;Lee, Young-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1846-1849
    • /
    • 2000
  • Off-line and on-line partial discharges were measured on a 828MVA, 22kV and direct hydrogen-cooled large turbine generator. Partial discharge tests were conducted using digital partial discharge detector(PDD) and turbine generator analyzer(TGA). PDD and TGA showed that off-line partial discharge pattern seems to be very, similar to that found with on-line. Most of the partial discharge is originating with the stator slot in the three phases. As the partial discharge activity is very low, the stator insulation condition of this generator is very good.

  • PDF

Analysis of Squirrel Cage Effect in Single Phase LSPM

  • Kim, Byung-Taek;Kim, Young-Kwan;Kim, Duk-Jin
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.4
    • /
    • pp.190-195
    • /
    • 2004
  • This paper presents the analysis of the effects of non-uniform slots in a line start permanent magnet (LSPM) motor. For purposes of the investigation, the simple formula of $2^{nd}$resistance for rotors having different slot areas is deduced. The characteristic analysis using the formula is performed and compared with measurement results.

Analysis of Partial Discharge Patterns in the Pumped Storage Generator Stator Windings (양수발전기 고정자 권선에서 부분방전 패턴의 분석)

  • Kim, Hee-Dong;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1015-1018
    • /
    • 1999
  • Partial discharge patterns were analyzed in the pumped storage generator stator winding. These were measured using partial discharge analyzer(PDA) and digital partial discharge detector(PDD). Slot discharge was discovered in phase A. Discharges at conductor surface were occurred in phase B and in Phase C. Partial discharge patterns from on-line PDA system were compared with those off-line PDD system. The results of two systems are very same in phase A, B and C.

  • PDF

Miniaturization of UWB Antenna Using Open Ended Stepped Slot (개방 종단된 계단형 슬롯을 사용한 UWB용 안테나의 소형화)

  • Lee, Ki-yong;Lee, Young-soon
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.4
    • /
    • pp.353-358
    • /
    • 2017
  • In order to reduce the size of the previous stepped slot antenna for UWB applications(3.1 ~ 10.6 GHz) to half, an open ended stepped slot antenna is proposed. The proposed antenna consists of a stepped slot etched on the ground plane as radiation part and a microstrip feed-line with rectangular patch on the top plane for wideband impedance matching. The proposed antenna is designed and fabricated on the FR4 substrate with dielectric constant of 4.3, thickness of 1.6 mm and size of $28.5{\times}32mm^2$. The measured impedance bandwidth (${\mid}S_{11}{\mid}{\leq}-10dB$) of the fabricated antenna is 7.99 GHz(3.01~11 GHz) which is sufficient to cover UWB band (3.1 ~ 10.6 GHz). In particular, it has been observed that antenna has a good omnidirectional radiation patterns and high gain over the entire frequency band of interest even though the size of the proposed antenna is reduced to half when compared with the previous antenna.