• Title/Summary/Keyword: Slot line

Search Result 257, Processing Time 0.024 seconds

A Compact and High Performance Lowpass Filter using Combined Characteristics of Slot and Open Stub (슬롯과 개방 스터브의 특성을 결합한 소형 저역통과 여파기)

  • 김경훈;김상인;박익모;임한조
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.1
    • /
    • pp.36-43
    • /
    • 2004
  • In this paper, we proposed a novel compact microstrip lowpass filter with an ultra-wide stopband and prominent cutoff sharpness using slot on the ground plane and microstrip shunt open stub. The microstrip shunt open stub and slot exhibit the different stopband response. The combined characteristics of these structures gives the ultra-wide stopband characteristics and the coupling effect between slots on the ground plane makes the prominent cutoff sharpness. The fabricated microstrip lowpass filter with the size of 20.1 mm ${\times}$ 18.7 mm has -3 ㏈ cutoff frequency at 1.187 ㎓ and -20 ㏈ stopband from 1.33 ㎓ to over 20 ㎓ and the insertion loss in the passband is less than -0.4 ㏈ form DC to 1 ㎓.

Assessment of Insulation Condition in Gas Turbine Generator Stator Windings (가스터빈 발전기 고정자 권선의 절연상태 평가)

  • Kim, Hee-Dong;Yang, Gyu-Hyun;Ju, Young-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.8
    • /
    • pp.1423-1428
    • /
    • 2010
  • The results of off-line and on-line diagnostic tests performed on the stator winding of an air-cooled gas turbine(G/T) generator are reported in this paper. Off-line diagnostic tests included measurements of the ac current, dissipation factor(tan${\delta}$), and partial discharge(PD). Six epoxy-mica capacitors were installed in the three phases of G/T generator for performing on-line diagnostic testing with the turbine generator analyzer(TGA). The TGA showed that the normalized quantity number(NQN) and the PD magnitude($Q_m$) were high in phase A of the stator winding. Internal discharges were generated in phases B and C, and slot discharge occurred in phase A. According to the trend analyses of the NQN and $Q_m$ values available for insulation condition assessment for G/T generator stator windings, it was concluded that phases B and C were in good condition, whereas phase A has been significantly deteriorated.

Design and Implementation of Compact Ultra Wideband Patch Antenna Using L-Feed and Slot-Feed (L 급전 및 Slot 급전을 동시에 적용하는 광대역 소형 패치 안테나의 설계 및 구현)

  • Choi, Jong-In;Lee, Bomson
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.5
    • /
    • pp.484-491
    • /
    • 2013
  • In this paper, the method of designing a wideband antenna has been introduced through the design technique that simultaneously employs L- and slot-type feeds. Using the two kinds of feeds and additional fence structure, a compact wideband patch antenna has been realized. The size of the patch has been reduced by about 30 % based on the low frequency(824 MHz) and the full fractional bandwidth is wider than 100 %. The L-feed element is for the EM coupling feeding at the low frequency, while it functions as a feeding line for the power coupling through the slot at the high frequency. The proposed antenna has been designed not only for wideband operations but also for a proper array element with a reduced size. Thus, the foundation for developing the ultra wideband patch array antennas has been prepared. The fabricated antenna has been found to have good characteristics on V.S.W.R and the radiation patterns over the full bands. The experimental and computed results are shown to be in good agreement.

Circuit Model Analysis for Traces that Cross a DGS

  • Jung, Kibum;Lee, Jongkyung;Chung, Yeon-Choon;Choi, Jae-Hoon
    • Journal of electromagnetic engineering and science
    • /
    • v.12 no.4
    • /
    • pp.240-246
    • /
    • 2012
  • This paper presents a novel modeling technique for traces that cross a defected ground structure. A simple and accurate equivalent circuit model provides clear insight into the coupling mechanism between a microstrip line and a slot or split. The circuit models consist of a transformer as the coupling mechanism and LC resonators as the ground with a slot or split structure. Resistors, capacitors, and inductors are added to the model to increase accuracy and equivalence at high frequency. Simulated and measured S-parameters are presented for defected ground structures. The accuracy and validity of the proposed equivalent circuit model is verified by evaluation of the S-parameter characteristics of the defected ground structures and comparison with measured results.

Analysis of On-Line Partial Discharge in High Voltage Motor Stator Windings (고압전동기 고정자 권선의 운전중 부분방전 분석)

  • Lee, Sang-Kil;Kim, Hee-Dong;Kim, Kwang-Hun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.152-155
    • /
    • 2002
  • During normal operation, partial discharge(PD) tests were performed using turbine generator analyzer(TGA) in high voltage motor. Epoxy-mica couplers are installed at motor terminal and analyzed PD signal using TGA. #A motor stator insulation is good because small partial discharges are detected PD pattern show that PD occurs in insulation. PD of #B motor is larger than that of #A motor and PD pattern show that positive PD larger than negative PD. It means that PD occurs between insulation and slot. And A phase PD magnitude of #B motor is large and high compare with any other phase. Therefore wedge, core and slot of #B motor need to check and repair.

  • PDF

Analysis of On-Line Partial Discharge in High Voltage Motor Stator Windings (고압전동기 고정자 권선의 운전중 부분방전 분석)

  • Lee, Sang-Kil;Kim, Hee-Dong;Kim, Kwang-Hun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.199-202
    • /
    • 2002
  • During normal operation, partial discharge(PD) tests were performed using turbine generator analyzer(TGA) in high voltage motor. Epoxy-mica couplers are installed at motor terminal and analyzed PD signal using TGA. #A motor stator insulation is good because small partial discharges are detected. PD pattern show that PD occurs in insulation. PD of #B motor is larger than that of #A motor and PD pattern show that positive PD larger than negative PD. It means that PD occurs between insulation and slot. And A phase PD magnitude of #B motor is large and high compare with any other phase. Therefore wedge, core and slot of #B motor need to check and repair.

  • PDF

A New Analysis of a Coupled Slotlines (결합 스롯트 선로의 새로운 해석)

  • 임영석;배정이
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.20 no.6
    • /
    • pp.1-5
    • /
    • 1983
  • A new equation, which enables us to calculate the characteristics of coupled slot-lines on a dielectric substrate, is derived. Their calculations are based on the single slot-line analysis of S.B. Cohn, but each equation of total admittance in the even mode and the odd mode is derived by a different approach. The results agree with Knorr and Kuchler's data.

  • PDF

Assessment of Insulation Condition in Operating Large Turbine Generator (운전중인 대형 터빈발전기에서 절연상태 평가)

  • 김희동
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.6
    • /
    • pp.324-329
    • /
    • 2004
  • Six stator slot couplers(SSC) and a flux probe sensor installed on the stator winding slots of large turbine generator. Assessment of insulation condition has been based upon the measurements of partial discharge(PD) of stator windings and shorted-turn of rotor windings in operating large turbine generator. The maximum PD magnitude(Qm), normalized quantify number(NQN), PD pattern and shorted-turn were measured using on-line insulation condition monitoring system. The NQN and Qm of slot PD side in the phase A are indicated the highest value in six SSC sensors. Monitoring system results showed that discharge at conductor surface and internal discharge were detected at the surface of stator winding and in voids of the groundwall insulation. Insulation of stator and rotor windings in large turbine generator was judged to be in good condition.

A design of the microstrip phased array antenna with the slot-coupled structure for the base station of mobile communication (슬롯결합구조를 갖는 이동통신 기지국용 마이크로스트립 위상배열 안테나의 설계)

  • 장정필;장병준;윤영중;박한규
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.12
    • /
    • pp.3205-3214
    • /
    • 1996
  • In this paper, the microstrip phased array antennas with coupling-slots for the base station of mobile communication is proposed and anlyzed with accurate analysis method which is based on both reciprocity principle and full-wave analysis. The basis functions used for the numerical analysis are determined depending upon the accuracy, convergence properties of the solution, and the computation time. The patch uses 3 EB mode and the slot uses IPWS mode. The designed phased array antenna has 8 slot-coupled microstrip patch array elements and the beam scanning capability is obtained by using the 4-bit PIN-diode phase shifters as switching devices which are consisted of the loaded line phase shifters for 30.deg. and 60.deg. and the reflection type phase shifters for 90.deg. and 180.deg. repectively. The 4-bits phase shifters which aremade by connecting each phase shifter have about 2.deg.-3.deg. phase errors and their insertion loss are about 3dB for each phase state. The fabricated 8-element phased array antenna with 4-bits phase shifters provides 12.deg.-14.deg. beamwidths depending on the scanning angle and is capable of scanning its beam to .+-.45.deg. with 9.deg. intervals, and the gain 12dBi. The overall results show that the slot-coupled phased array antenna has great advantages of wideband, high gain and reduced spurious radiation. Also, the antenna can be made small and thin. Furthermore, the scanning property of this antenna allows for its application in several areas, such as mobile communication system and PCS.

  • PDF

A Study on Slot Coupled Capacitor Resonator for Non-Invasive Glucose Monitoring in Earlobe (귓불에서 비침습 혈당관찰을 위한 슬롯결합 커패시터 공진기 연구)

  • Yun, Gi-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.4
    • /
    • pp.279-285
    • /
    • 2017
  • In this paper, the resonator with a parallel plate capacitor is newly proposed around sub-microwave frequency band and applied to earlobe for non-invasive glucose monitoring the human biological tissue. The capacitor including the earlobe as dielectric material is connected to inductive slot in the ground plane of the microstrip line. Based on the simulation, one port resonator circuit is designed and fabricated as a prototype. Three step glucose concentration levels(0, 250, 500 mg/dL) was tested, and its reflection coefficients($S_{11}$) were measured. Owing to high Q resonator more than 100, resonant frequency shift of about 9 MHz per glucose level of 250 mg/dL has been successfully measured. This proves that the proposed sensor is applicable to a blood glucose sensor.