A Study on the inspection item classified by reinforcement method for the construction slope maintenance (건설공사 비탈면 유지관리를 위한 보강공법별 점검항목에 관한 연구)

  • Kim, Yong-Soo;Chang, Buhm-Soo;Shin, Kwan-Young
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.759-764
    • /
    • 2005
  • With the tunnel to case of the construction slope it executes the periodic maintenance due to an objectivity standard. But, the standard connected with construction slope is not integrated with the important public paper organic enemy and it is duplicated and the standards which conflict are being scattered. Also, it is referred to some specifications simply and the feature which is diffuse appears. Therefore, there is a necessity which it investigates the problem point of the maintenance civil official and it improves rationally and it takes a triangular position a confusedly be standard system. In this research which it sees accomplished the fundamental research against the inspection item classified by reinforcement method for the construction slope maintenance.

  • PDF

A Study on the Control Characteristics of Line Scan Light Source for Machine Vision Line Scan Camera (머신 비전 라인 스캔 카메라를 위한 라인 스캔 광원의 제어 특성에 관한 연구)

  • Kim, Tae-Hwa;Lee, Cheon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.5
    • /
    • pp.371-381
    • /
    • 2021
  • A machine vision inspection system consists of a camera, optics, illumination, and image acquisition system. Especially a scanning system has to be made to measure a large inspection area. Therefore, a machine vision line scan camera needs a line scan light source. A line scan light source should have a high light intensity and a uniform intensity distribution. In this paper, an offset calibration and slope calibration methods are introduced to obtain a uniform light intensity profile. Offset calibration method is to remove the deviation of light intensity among channels through adding intensity difference. Slope calibration is to remove variation of light intensity slope according to the control step among channels through multiplying slope difference. We can obtain an improved light intensity profile through applying offset and slope calibration simultaneously. The proposed method can help to obtain clearer image with a high precision in a machine vision inspection system.

Stability Analysis and Reinforcement of Large Excavated Slope considering Precipitation Infiltration in Rainy Season (강우침투로 인한 대절취사면의 붕괴안정성검토 및 대책)

  • Chun, Byung-Sik;Choi, Hyun-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.1
    • /
    • pp.101-110
    • /
    • 2000
  • In case heavy rainfall is a key factor of slope failure, the failure zone is usually developed within the depth of 3~5m from the ground surface regardless of the location of the watertable. If rainfall is taken into consideration, it is general that the slope stability analysis is carried out under the assumption that the cut slope is saturated to the slope surface or the watertable elevates to a certain height so that ${\gamma}_{sat}$, the unit weight of saturated soil, is used. However, the analysis method mentioned above can't exactly simulate the variation of pore water pressure in the slope and yields different failure shape. The applicability of slope stability analysis method considering the distribution of pore water pressure within the slope with heavy rainfalls, was checked out after the stability analysis of a lage-scale cut slope in a highway construction site, where surface failure occurred with heavy rainfalls. An appropriate slope stabilization method is proposed on the base of the outcome of the analysis.

  • PDF

Development of Portable Multi-function Sensor (Mini CPT Cone + VWC Sensor) to Improve the Efficiency of Slope Inspection (비탈면 점검 효율화를 위한 휴대형 복합센서 개발)

  • Kim, Jong-Woo;Jho, Youn-Beom
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.1
    • /
    • pp.49-57
    • /
    • 2022
  • In order to efficiently analysis the stability of a slope, measuring the shear strength of soil is needed. The Standard Penetration Test (SPT) is not appropriate for a slope inspection due to cost and weights. One of the ways to effectively measure the N-value is the Dynamic Cone Penetration Test (DCPT). This study was performed to develop a minimized multi-function sensors that can easily estimate CPT values and Volumetric Water Content. N value with multi-fuction sensor DCPT showed -2.5 ~ +3.9% error compared with the SPT N value (reference value) in the field tests. Also, the developed multi-fuction sensor system was tested the correlation between the CPT test and the portable tester with indoor test. The test result showed 0.85 R2 value in soil, 0.83 in weathered soil, and 0.98 in mixed soil. As a result of the field test, the multi-function sensor shows the excellent field applicability of the proposed sensor system. After further research, it is expected that the portable multi-function sensor will be useful for general slope inspection.

A Case Study on the Stability Analysis for Masonry Retaining Walls and Backfill (석축구조물 및 배면지반의 안정성 검토사례연구)

  • Chun, Byung-Sik;Yeoh, Yoo-Hyeon;Kim, Kyung-Min
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.1
    • /
    • pp.149-160
    • /
    • 2001
  • In this paper, the stability analyses were performed for masonry retaining wallls in Seoul subway System. This masonry retaining wallls were reinforced with earth anchor system for the construction, but it was removed after construction. Therefore, the stability of masonry retaining wallls should be checked after the earth anchors removed. For stability analysis of masonry retaining wallls. FDM analysis(FLAC Ver.3.3) and slope stability analysis (SLOPE/W) were performed applying the test results from laboratory and field tests(Schmidt hammer test, cack examination). As conclusion, the tension force of earth anchors should be kept, therefore, substitutional method was required in order to keep the tension force of earth anchor system.

  • PDF

Construction and Utilization Plan of Steep Slope and Underground Spatial Information DB for Steep Slope Disaster Prevention (급경사지방재를 위한 급경사지정보 및 지하공간정보 DB 구축과 활용 방안 연구)

  • Lee, Kyungchul;Jang, Yonggu;Song, Jihye;Kang, Injoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.7
    • /
    • pp.13-21
    • /
    • 2014
  • Recently, a great number of natural disasters have more frequently happened than the past. The National Emergency Management Agency of Korea has made preparation for the integrated management system of steep slope lands. There is information based on the steep slope inspection sheets and the underground spatial information related to the prevention against steep slope disasters. Nevertheless, building a complete DB System to prevent the hazards and secure the safeties should be urgently dealt with. It is mainly because the information of the National Disaster Management System is restricted to the text-based brief data. Therefore, the purpose of this study is to suggest the method as to building steep slope DB system for disaster prevention and maximizing the availabilities. This study shows the way of building a web-based DB system having its root in the steep slope inspection sheets. The method of establishing the ideal DB system that has liaisons between the Ministry of Land, Infrastructure and Transport and the National Emergency Management Agency is discussed in this study. Furthermore the optimization of DB utilization will assist the various integrated steep slope management systems based on U-IT which are ongoing projects.

A Terrain Data Acquisition for Slope Safety Inspection by Using LiDAR (지상 LiDAR에 의한 사면안전진단용 지형정보 취득)

  • Lee, Jong Chool;Kim, Hee Gyoo;Roh, Tae Ho
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.31 no.4
    • /
    • pp.311-319
    • /
    • 2013
  • As heavy rains occur more frequently due to the recent climate change, slope collapses are increasing, and damage to human life and properties is accordingly increasing every year. The most proper method to take preventive measures against slope collapses is to remove the cause after understanding the cause of slope collapse in advance, and for such, slope safety inspection is implemented for preventive purposes, to investigate the cause, and as a measure for restoration. Thus, this Research was able to reach the following conclusion after utilizing LiDAR, which obtains detailed topographic information in a short period of time with point cloud data on slopes subject to safety inspection. First, as a result of analyzing the errors after installing a check point in the subject area, the RMSE of the horizontal location error appeared to be ${\pm}2.2cm$ and the RMSE of the vertical location error appeared to be ${\pm}3.0cm$, which shows a practically satisfactory result. Second, the economic feasibility was outstanding and obtaining accurate topographic information was available. Third, an area once scanned allowed to accurately obtain an unprescribed cross-sectional diagram in a short period of time, thus, appeared to be convenient for experts to detect dangerous sections.

A Study on conclusion about inventory survey on cut slope along national roads in Korea (국내 국도변 비탈면 현황 분석 연구)

  • Park, Jae-Young;Shin, Chang-Gun;Jang, Bum-Su
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.722-726
    • /
    • 2010
  • Inventory survey is process collecting data about cut slope. It's different from inspection. It contains not only basic information about cut slope, especially location, GPS positioning, height, length, weathering, joint direction, water conditions but also level of danger and damage. Collected data are being used get at status about cut slope along national roads. And It helps judging about priority of detailed investigation. According to results of analysis, we found better method about maintenance of cut slope. Later on, if inventory research is finished, we will understand characteristics of collapse slopes.

  • PDF

Analysis for Current Situation of Slope along National Roads in Korea (국내 국도변의 비탈면 현황 분석 연구)

  • Park, Jaeyoung;Shin, Changgun;Chang, Bumsu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.12
    • /
    • pp.19-25
    • /
    • 2010
  • Inventory survey is process collecting data about cut slope. It's different from inspection. Collected data are being used get at status about cut slope along national roads. And we analyse between current situation and data about collapse slope. It helps finding better method about maintenance of cut slope. We found changes in the situation between data at present and data at 10 years ago. We will research collapse and counterplan by cause.

Inspection method of BGA Ball Using 5-step Ring Illumination (5층 링 조명에 의한 BGA 볼의 검사 방법)

  • Kim, Jong Hyeong;Nguyen, Chanh D.Tr.
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.12
    • /
    • pp.1115-1121
    • /
    • 2015
  • Fast inspection of solder ball bumps in ball grid array (BGA) is an important issue in the flip chip bonding technology. Particularly, semiconductor industry has required faster and more accurate inspection of micron-size solder bumps in flip chip bonding, as the density of balls increase dramatically. In this paper, we describe an inspection approach of BGA balls by using 5-step ring illumination device and normalized cross-correlation (NCC) method. The images of BGA ball by the illumination device show unique and distinguishable characteristic contours by their 3-D shapes, which are called as "iso-slope contours". Template images of reference ball samples can be produced artificially by the hybrid reflectance model and 3D data of balls. NCC values between test and template samples are very robust and reliable under well-structured condition. The 200 samples on real wafer are tested and show good practical feasibility of the proposed method.