• Title/Summary/Keyword: Sliding member

Search Result 9, Processing Time 0.026 seconds

A Study on the Wear Testing of Silding Members of Hydraulic Rotary Actuator (유압피스톤 모터용 습동부재의 마모실험에 관한 연구)

  • 김광영;함영복;이태서
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.608-613
    • /
    • 1997
  • This study discusses the developmentof hydraulic rotary actuator design technology for industriol machinery and earthmoving equipment. The lubrication and wear analysis of sliding components of the machinery are very important parameters to sterngth the design technique. The analysis and were test are performed for the selected materials of the above mentioned coupled sliding members using the experimental results. One can selsct the better combination of sliding components.

  • PDF

Effect of Caisson Tilting on the Sliding Distance of a Caisson under Wave Impacts and Introduction of the Effect into Computation of Sliding Distance

  • Kim, Tae Min;Takayama, Tomotsuka
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.474-478
    • /
    • 2004
  • Based on the recent laboratory experiments (Kim et al. 2004), comparisons of caisson sliding distance are made between the computations and experiments. The time history model of wave force, which is proposed by Tanimoto et al. (1996), is modified in the standing wave part of horizontal and uplift wave forces because of the overestimation of the time history model. The comparison between experimental and computational sliding distance has showed that the caisson tilting increases the resistant force to the horizontal sliding. Therefore, a titling resistant force, which is caused by caisson tilting, is introduced into computation of sliding distance.

  • PDF

A Study on the Wear Testing of Sliding Members of Hydraulic Rotary Actuator (유압피스톤 모터용 습동부재의 마모실험에 관한 연구)

  • Kim, Gwang-Yeong;Ryu, Byeong-Sun;Kim, Jong-Su;Choe, Byeong-O;Yun, Du-Pyo
    • 연구논문집
    • /
    • s.28
    • /
    • pp.101-110
    • /
    • 1998
  • This study discusses the developement of hydraulic rotary actuator design technology for industrial machinery and earthmoving equipment. The lubrication and wear analysis of sliding components of the machinery are very important parameters to strength the design technique. The analysis and wear test are performed for the selected materials of the above mentioned coupled sliding members. The can be used to select the better combinations of sliding components.

  • PDF

Development and Nonlinear Dynamic Model of Sliding Wall Damper To Retrofit of R/C Frame Structures (R/C 골조구조물 내진보강을 위한 슬라이딩 벽식감쇠기의 개발 및 비선형 동적해석모델)

  • 조창근;박문호;장준호;김기욱;정인규
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.04a
    • /
    • pp.411-418
    • /
    • 2003
  • In order to retrofit R/C frame structures, a newly proposed Teflon sliding wall damper, consisted of Teflon slider and R/C shear wall, is evaluated by the dynamic analysis model of inelastic frame structures. From analysis results, it is shown that the damper reduces the time-history responses, the maximum story drifts, and the damage of R/C member. By control of damper pressures, especially, the damper can be easily applicable not only to capacity design according to required responses and member damages but also to active damper with actively controlling devices.

  • PDF

Ice impact on arctic gravity caisson (극지용 중력식 해양구조물의 유빙충격 해석)

  • Yu, Byung-Kun
    • Journal of Ocean Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.52-59
    • /
    • 1987
  • 극 지역용 중력식 해양구조물의 설계시 고려되어야 할 문제중의 하나가 구조물의 유빙(ice)과 충돌시 야기되는 foundation붕괴 현상인데, 본 논문에서는 정적 해석을 위해 sliding 및 bearing failure 현상에 대하여만 연구하였고, 또한 동적 해석을 위하여 soil과ice의 특성으로부터 structure-ice-soil의 상호 작용 운동 방정식을 설정하여 구조물과 ice의변위, 속도, 가속도와 ice force와 soil force의 history를 시간영역 해법으로 풀었다. 한 예제로 Beaufort Sea의 37 feet수심과 granular soil 상태에서 구조물의 최대변위는 0.4 feet이고 가속도는 약 0.3kg이며 이때 구조물이 sliding에 대하여 안전하다는 것이 입증되었다.

  • PDF

A Study on Serviceability of Oversized Bolt Hole in High-Tension Bolt Joint Subjected to Bending (휨을 받는 고장력볼트 체결부에서 과대공에 따른 사용성에 관한 연구)

  • Park, Jeong-Ung;Yang, Seung-Hyun;Jang, Suk-In
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.10
    • /
    • pp.2831-2836
    • /
    • 2009
  • If a design load exceeding the frictional force of the contact surface is applied to the connection of steel members using a high-tension bolt friction joint, sliding occurs and the connection of the steel members bears the design load through the shear strength and bearing strength of the bolt and the base plate. The sliding distance can be determined by the tensile force of the bolt, the friction coefficient of the contact surface, and the position of the bolt in the base plate hole. This study measured and analyzed sliding according to standard bolt hole and oversize bolt hole when pure bending moment and tensile force were applied to high-tension bolt joints with different sizes of bolt holes made in the base plate and the cover plate. In a high-tension bolt joint receiving pure bending moment and tensile force, the load causing sliding in an oversize bolt hole was $74\sim94%$ of that in a standard bolt hole. In a member receiving tensile force, the sliding load ratio was lower when the size of oversize bolt holes in the base plate and the cover plate was large. In addition, the size of the oversize bolt hole in the base plate was more closely correlated with the change of sliding loadthan the size of the oversize bolt hole in the base plate.

Nonlinear Analysis with contact element between old and new concrete (Contact 요소를 이용한 신.구 콘크리트의 비선형 해석)

  • Cho, Sun-Kyu;Lee, John-Sun;Jeong, Woo-Cheol;Lee, John-Shin
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1050-1055
    • /
    • 2007
  • In the case of a rail road bridge extension work, especially single track to double track, the foundation of new substructure which supports the extended part of superstructure could be interfered by the exist foundation of an old bridge. When these two foundations are jointed to prevent such fatal effects of the structure as unequal subsidence of soil foundations, it is important to prove the structural behaviour of the joining surfaces between new foundation and old foundation. 3-Dimensional Finite Element Analysis Method have been studied for the solutions of the structural behaviour of the foundations. In this analysis, 'Contact Element' which allows the sliding of each adjoining member is used for the joint of the boundary surface of the old and new pier foundations. Furthermore, Material Nonlinear Behaviour Analysis also supports the accuracy of the result in this study because the foundations consist of concrete main bodies and reinforced steel bars. These detailed analyses secure the verification of the structural safety of the foundations in the extension work more firmly.

  • PDF

Evaluating Stability and Functionality of Hybrid Erosion Control Dam for Reducing Debris Flow Damage in Forested Catchment Nearby Urban Area (도시생활권의 토석류 피해 저감을 위한 복합형 사방댐의 안정성 및 기능성 평가)

  • Kim, Kidae;Kim, Dongyeob;Seo, Junpyo;Lee, Changwoo;Woo, Choongshik;Kang, Minjeng;Jeong, Sangseom;Lee, Dongkyun
    • Journal of Korean Society of Forest Science
    • /
    • v.107 no.1
    • /
    • pp.59-70
    • /
    • 2018
  • The objective of this study was to develop erosion control dam for preventing disaster in consideration of characteristics of forested catchment near urban area, and to assess its stability and functionality to see its practicability in the field. Two types of hybrid erosion control dams were developed including debris flow prevention dam by using pillar and float board screen type and debris flow control dam by using groyne. Also, review about their static (sliding, overturning, bearing capacity) and dynamic (member force) stability was carried out. According to the result, most of the assessed items met standard safety level although there were some cases where assessed items were short of stability criteria against impact. Also, after miniature flume experiments based on the developed erosion control dam to prove structure function (material catch, deposit), it turned out the dam decreased flow sediment amount and velocity while increasing sediment-capturing capacity by 3.5 times on average compared to the one controlled without erosion control dam. When function of erosion control dam for forested catchment near urban area is quantified based on future flume experiments in a variety of conditions, the dams can be practically used in the urban area, contribution to effectively reducing debris flow damage.