• Title/Summary/Keyword: Slice

Search Result 980, Processing Time 0.025 seconds

Measurement of the Noise according to the Slice Thickness in MDCT (MDCT에서 절편두께에 따른 Noise 측정)

  • Moon, Il-Bong;Dong, Kyung-Rae;Kim, Mi-Hyun;Choi, Sung-Hyun;Kweon, Dae-Cheol;Goo, Eun-Hoe
    • Journal of Radiation Industry
    • /
    • v.11 no.3
    • /
    • pp.151-155
    • /
    • 2017
  • MDCT is used to determine how the noise changes as the slice thickness changes. Noise according to thickness of 1.5, 3.0, 5.0 and 10.0 mm was analyzed using the Siemens (Somatom Definition Flash, Germany) equipment and calibration conditions such as tube voltage and tube current using the calibration QC phantom. 1.5, 3.0, 5.0 and 10.0 mm, respectively. The mean HU was 1.5 mm (7.7 HU), 3.0 mm (4.9 HU) and was reduced by 59.5% from 1.5 mm. 5.0 mm (3.9 HU) and 97.6% compared to 1.5 mm, 10.0 mm (3.1 HU) and 148% less than 1.5 mm. It was found that as slice thickness increased, noise decreased, while slice thickness decreased. In conclusion, setting the appropriate slice thickness for each site may be useful for obtaining appropriate noise and image quality.

Possible Changes of East Asian Summer Monsoon by Time Slice Experiment (Time Slice 실험으로 모의한 동아시아 여름몬순의 변화)

  • Moon, JaYeon;Kim, Moon-Hyun;Choi, Da-Hee;Boo, Kyung-On;Kwon, Won-Tae
    • Atmosphere
    • /
    • v.18 no.1
    • /
    • pp.55-70
    • /
    • 2008
  • The global time slice approach is a transient experiment using high resolution atmosphere-only model with boundary condition from the low resolution globally coupled ocean-atmosphere model. The present study employs this "time slice concept" using ECHAM4 atmosphere-only model at a horizontal resolution of T106 with the lower boundary forcing obtained from a lower-resolution (T42) greenhouse gas + aerosol forcing experiment performed using the ECHO-G/S (ECHAM4/HOPE-G) coupled model. In order to assess the impact of horizontal resolution on simulated East Asian summer monsoon climate, the differences in climate response between the time slice experiments of the present and that of IPCC SRES AR4 participating 21 models including coarser (T30) coupled model are compared. The higher resolution model from time slice experiment in the present climate show successful performance in simulating the northward migration and the location of the maximum rainfall during the rainy season over East Asia, although its rainfall amount was somewhat weak compared to the observation. Based on the present climate simulation, the possible change of East Asian summer monsoon rainfall in the future climate by the IPCC SRES A1B scenario, tends to be increased especially over the eastern part of Japan during July and September. The increase of the precipitation over this region seems to be related with the weakening of northwestern part of North Pacific High and the formation of anticyclonic flow over the south of Yangtze River in the future climate.

A Transition Reduction Algorithm of Finite State Machines using Slice Models (Slice 모델을 이용한 유한상태머신의 트랜지션 축약 알고리즘)

  • Lee, Woo-Jin
    • Journal of KIISE:Software and Applications
    • /
    • v.35 no.1
    • /
    • pp.12-21
    • /
    • 2008
  • As the usage of computer systems is increasing in our lives, the reliability and safely of these systems need to be thoroughly checked through the verification techniques. As a basic formalism for several modeling methods, the finite state machine (FSM) is widely used in specification and verification of system models. And there is a technique for ing internal events of FSM in order to effectively analyze the system. However, this technique does not handle the state explosion problem since it can be applied after completely generating all the state space of the system. In this research, we provide a new approach for efficiently representing concurrent properties of FSM, the slice model and provide an efficient transition reduction method based on the slice model. Our approach is effective in time and space perspective since it is peformed by partially generating the needed system states while the existing abstraction technique can be applied to all the system states.

디지탈시스템과 마이크로프로세서 설계 5

  • 김명항
    • 전기의세계
    • /
    • v.31 no.11
    • /
    • pp.775-786
    • /
    • 1982
  • Bit-slice 마이크로프로세서의 구조를 설명하고, bit-slice시스템의 설계를 위해 필요한 마이크로 인스트럭숀의 구성과 pipelining 기법에 관해 토의한다.

  • PDF

Evaluation of Brain Damage Induced by Transient Occlusion of Middle Cerebral Artery in Rats

  • Insook Jung;Lee, Juseon;Melissa D. Oh;Kim, Myungsoo;Changbae Jin
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1997.04a
    • /
    • pp.103-103
    • /
    • 1997
  • 일시적인 국소 뇌허혈 rat model에서 중대뇌동맥의 폐쇄시간에 따른 뇌조직의 손상정도를 비교 조사하였다. 웅성 Wistar rats를 isoflurane 홉입마취하에서 우측 내경동맥내로 17 mm의 silicone-coated 4-0 nylon monofilament를 삽입하여, 중대뇌동맥의 기저부를 30분, 60분 또는 90분동안 폐쇄한 후 이 monofilament를 다시 밖으로 뽑아내므로써 23 시간동안 recirculation 시키는 일시적 국소 뇌허혈 rat model을 사용한 결과, 수술 후 거의 모든 rats에서 left hemiparesis 또는 좌측으로의 circling과 같은 신경학적 결손이 나타나므로써 높은 성공률을 가지고서 비교적 용이하게 뇌허혈을 유발시킬 수 있었으며, 2 mm 두께의 fresh brain coronal slices에 대하여 2,3,5-triphenyltetrazolium chloride (TTC) 염색법을 시행하여 slice surface의 사진을 찍고 computerized 영상분석법을 이용하여 필요한 면적을 측정하므로써, coronal slice의 infarction size (%)는 총 면적에 대한 infarction 면적의 %로서, 부종율 (%)은 대조측 대뇌반구 면적의 2배에 대한 동측 대뇌반구와 대조측 대뇌반구 면적 차이의 %로서 산정되어졌다. 30분 허혈군에서는 본 염색법으로는 infarction이 거의 확인되지 않았으나 60분 허혈군 (n=13)에서는 우측 somatosensory frontoparietal cortex와 striatum 양자 모두 또는 일부 rats에서는 striatum에만 국한된 ulfarction이 확인되어졌으며 90분 허혈군 (n=12)에서는 거의 대부분의 rats에서 위 두 지역 모두에서 infarction이 확인되어졌다. Infarction size (%)는 60분과 90분 허혈군 각각에서, frontal pole로부터 5 mm되는 slice에서는 11.9$\pm$1.2 (평균치$\pm$표준오차), 13.7$\pm$1.9이었으며 7 mm되는 slice에서는 19.1$\pm$1.8, 21.9$\pm$2.1이었으며 9 mm되는 slice에서는 14.7$\pm$2.4, 19.7$\pm$2.2이었다. 또한 부종율 (%)은 60분과 90분 허혈군 각각에서, frontal pole로부터 5 mm되는 slice에서는 3.1$\pm$0.6, 3.8$\pm$0.7이었으며 7 mm되는 slice에서는 3.5$\pm$0.3, 5.7$\pm$1.0이었으며 9 $\pm$되는 slice에서는 3.4$\pm$0.5, 5.7$\pm$0.9이었다. 한편 90분 동안의 중대뇌동맥 폐쇄에 따른 뇌조직 손상을 cresyl violet 염색법, NADPH-diaphorase histochemistry, GFAP immunohistochemistry를 사용하여 일부 측정한 결과, 위의 손상지역에서는 뇌신경세포체들의 shrinkage 내지는 소실됨을 확인할 수 있었으며, NADPH-diaphorase-positive neuron들도 대부분 dendrite와 axon같은 cell process들의 fragmentation, shrinkage 내지는 소실되므로써 intensity의 감소현상이 나타났으며, reactive gliosis로 말미암아 GFAP immunoreactive intensity의 증가현상이 나타났다.

  • PDF

Diagnosis of Phythopthora sp. and Its Concentration by Potato Slices in Series Culture Soils.

  • Lee, Jung-Sup;Park, Jong-Hwan;Han, Kyeong-Suk;Park, Young-Mun
    • Proceedings of the Korean Society of Plant Pathology Conference
    • /
    • 2003.10a
    • /
    • pp.129.2-130
    • /
    • 2003
  • Tomato soil pathogens(Phythopthora spp.) analyed high rates in series culture soil and existed in culture parts. To make a diagnosis of Phythopthora sp. and Its concentration, potato slices were manufactured to a round shape(2.5cm) or retangular form(1x4cm). and then, The potato slices dipped into diagnostic reagents with an antibiotic substance for 2∼4hours. Potato slices treated with a few reagents varied into 15cm depths in innoculated soils for 24hrs. Mycelium of the Phytophthora root rot fungus, Phythopthora capsici, were produced easily on potato slice. We collected many potato slice samples on diseased fields in various area. After storage of 24hrs in 20$^{\circ}C$ incubator, White mycelium of Phythopthora sp. formed on potato slice surface. Dilute concentrations of Phythopthora sp. was detected very low contents(1${\times}$10$^1$sporangia/g). But expressing Phythopthora root rots on potato slice did not developed larger lesions upon storage time in room temperature. These results suggest that the use of potato slice in a series of soil cultural system may still serve as efficient means of diagnosis of Phythopthora root rots in the absence of control measures.

  • PDF

Global Positioning System 응용을 위한 파이프라인 형 CORDIC회로 설계

  • 이은균;유영갑
    • The Magazine of the IEIE
    • /
    • v.23 no.11
    • /
    • pp.89-100
    • /
    • 1996
  • A new stage-sliced pipiline structure is presented to design a high speed real time Global Positional Systems(GPS) applications. The CORDIC algorothm was revised to generate a pipeline structure, which will be used to produce a large amount of trigonometric computations rapidly. A stage-sliced approach was introduced to adjust the number of interative processes, and thereby to control the precision of computation results. Both the computation and the control circuits of the proposed architecture are included in a pipeline stage, which are intergrated into a stage slice. The circuit was prototyped using six FPGA chips : one is used for glue logics and five of the chips are used for pipeline slice implementation. A single FPGA chip comprising 7 pipeline stages provides one pipeline slice. To compensate and inter-slice time delay, dummy cycles are introduced in inter-slice signal exchanges.

  • PDF

A Comparative Study of Spiral Tomograms with Different Slice Thicknesses in Dental Implant Planning (인공치아 매식술 계획에 있어서 상이한 단층두께의 나선형 단층사진의 비교)

  • Yoon Suk-Ja
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.191-201
    • /
    • 1999
  • Purpose: To know whether there would be a difference among spiral tomograms of different slice thicknesses in the measurement of distances which are used for dental implant planning. Materials and Methods: 10 dry mandibules and 40 metal balls were used to take total 120 Scanorailll tomograms with the slice thickness of 2 mm, 4 mm and 8 mm. 3 oral radiologists interpreted each tomogram to measure the distances from the mandibular canal to the alveoalr crest and buccal. lingual and inferior borders of mandible. 3 observers recorded grades of 0, 1 or 2 to evaluate the perceptibility of alveolar crest and the superior border of mandibular canal. ANOVA with repeated measure. Chi-square tests and intrac!ass correlation coefficient(R₂, α) were used For statistical analysis. Results: There was not a statistically significant difference among spiral tomograms with different slice thicknesses in the measurement of the distances and in the perceptibility of alveolar crest and mandibular canal(p>0.05). All of them showed a good relationship in the reliability analysis. The perceptibility of alveolar crest and mandibular canal was almost similar and an excellent relationship was seen on all of them. Conclusions: There would be no significant difference. no matter which spiral tomogram of any slice thickness may be used in dental implant planning. considering the thickness of dental implant fixture.

  • PDF

Unscented Kalman Snake for 3D Vessel Tracking

  • Lee, Sang-Hoon;Lee, Sanghoon
    • Journal of International Society for Simulation Surgery
    • /
    • v.2 no.1
    • /
    • pp.17-25
    • /
    • 2015
  • Purpose In this paper, we propose a robust 3D vessel tracking algorithm by utilizing an active contour model and unscented Kalman filter which are the two representative algorithms on segmentation and tracking. Materials and Methods The proposed algorithm firstly accepts user input to produce an initial estimate of vessel boundary segmentation. On each Computed Tomography Angiography (CTA) slice, the active contour is applied to segment the vessel boundary. After that, the estimation process of the unscented Kalman filter is applied to track the vessel boundary of the current slice to estimate the inter-slice vessel position translation and shape deformation. Finally both active contour and unscented Kalman filter are inter-operated for vessel segmentation of the next slice. Results The arbitrarily shaped blood vessel boundary on each slice is segmented by using the active contour model, and the Kalman filter is employed to track the translation and shape deformation between CTA slices. The proposed algorithm is applied to the 3D visualization of chest CTA images using graphics hardware. Conclusion Through this algorithm, more opportunities, giving quick and brief diagnosis, could be provided for the radiologist before detailed diagnosis using 2D CTA slices, Also, for the surgeon, the algorithm could be used for surgical planning, simulation, navigation and rehearsal, and is expected to be applied to highly valuable applications for more accurate 3D vessel tracking and rendering.

Analysis of Slope Stability by Applying the Convergence of the Interstice Forces (분할편 경계내각 수렴에 의한 사면안정 해석)

  • 김팔규;김규문
    • Geotechnical Engineering
    • /
    • v.3 no.4
    • /
    • pp.21-30
    • /
    • 1987
  • The purpose of this paper is to develop a method of slope stability analysis, using slice method The direction of interstice forces was assumed in two ways: 1) inclined interslice force parallel to the base of slice, 2) normal interslice force normal to the boundary surface of slice being used in the existing slice method. The deviation from the value of interstice force caused by assumption was removed in the Processing of analysis, and the factor of safety was obtained more accurately by deciding the location of interstice force acting on each slice. More rational validity of the method with inclined interslice force was proved by performing slope stability analyses with both methods. The factor of safety obtained by the proposed method was compared with that by the existing methods, and the influence of seismic coefficient was also analyzed.

  • PDF