• Title/Summary/Keyword: Sleep Monitoring

Search Result 121, Processing Time 0.022 seconds

Unmanned Patient Monitoring System Using Frame Difference Method and Decibel Threshold (프레임 차이법과 데시벨 임계치를 이용한 무인 환자 감시 시스템)

  • Lee, Kee-Woo;Lee, Hyuk-Soo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • In this paper, we propose an unmanned patient monitoring system design and performance of a motion capture and sound detection. Unmanned patient monitoring system can be used in the greek koma and meaning deep sleep patient to need 24 hour surveillance. To monitoring, we used laptop, CCTV camera (or PC camera), A/D converter, microphone and detection program. The detection program based on the frame difference method and sound level meter. It had several functions such as data collecting and storing. All of this system was tested in several the simulations of emergency situations. It can be expected that an unmanned patient monitoring system can be used in emergency situation and patient care.

  • PDF

Snoring Detection using Polyvinylidene Fluoride Vibration Sensors (Polyvinylidene Fluoride 진동센서를 이용한 코골이 검출)

  • Jee, Duk-Keun;Wei, Ran;Kim, Hee-Sun;Im, Jae-Joong
    • Science of Emotion and Sensibility
    • /
    • v.14 no.3
    • /
    • pp.459-466
    • /
    • 2011
  • Sleep diseases such as snoring and sleep apnea are physically, mentally harmful and results serious health problems. Snoring, known as breathing noise, is caused by coupled oscillation of the airway when the air passes through the trachea, and sleep apnea is caused by upper airway blockage. In order to solve these problems, many attempts have been made to detect the snoring during sleep and alleviate it. In this study, a new sensing system and analysis algorithm were developed in order to detect snoring sounds correctly under various sleep environments. Two polyvinylidene fluoride (PVDF) vibration sensors were used inside the pillow. The first PVDF sensor detects vibration transmitted through skull caused by snoring. And the second PVDF sensor detects both snoring sounds and ambient noises. The signals of two sensors were acquired through the designed analog circuits, and analyzed for snoring detection. Ten volunteers were participated for the experiment under five different conditions. Data from two PVDF sensors were processed by the established analysis algorithm, and snoring sounds were compared to noises. The results indicated that the energy of snoring is 70% bigger than that of ambient noise, which proves effectiveness of sensing system and analysis algorithm. Further study would be continued for more wide clinical studies with various environment noises. Based on this study, development of anti-snore pillow and sleep monitoring system for comfort sleep could be developed.

  • PDF

Implemetation of Real-time Monitoring System for Obstructive Sleep Apnea Based on Smart-phone (스마트폰 기반의 실시간 수면 무호흡 모니터링 시스템 구현)

  • Ju, Seok-Il;Hong, Seong-Gyun;Ye, Soo-Young;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.791-792
    • /
    • 2011
  • 폐쇄성 수면 무호흡증 환자 중 가장 위험한 2~8세 아동들의 지속적인 수면 상태를 모니터링하는 것은 중요하며, 야간에 수면 상태를 모니터링 하는 것은 보호자에게 스트레스와 일상생활에 지장을 초래할 수 있다. 본 연구에서는 아동들의 수면 상태를 측정하기 위한 스마트폰 기반의 실시간 호흡 모니터링 시스템을 구현하였다. 구현된 시스템은 아동의 수면 중 자세 변화로 인한 잦은 폐쇄성 수면 무호흡을 지속적으로 모니터링 함으로써 수면 상태 모니터링 및 위험 상황을 인지할 수 있으며, 보호자에게 편안한 수면을 제공한다.

  • PDF

Mechanism and Neuroanatomy of Auditory Hallucination (환청의 기전과 신경해부학)

  • Lee, Seung-Hwan;Suh, Kwang-Yoon
    • Sleep Medicine and Psychophysiology
    • /
    • v.8 no.2
    • /
    • pp.98-106
    • /
    • 2001
  • Auditory hallucinations are cardinal feature of psychosis. But the mechanism of hallucinated speech is unknown. The hypothesis that these hallucinations arise from pathologically altered brain monitoring system underlying speech perception is influential. With the help of rapidly developing neuroimaging study technologies, many researchers have been finding new organic deficits in the hallucinated schizophrenic patient's brain. In this article, we reviewed the general appearance of hallucination, a computer simulation model of hallucination and several neuroimaging study findings on hallucinating schizophrenic patients. In conclusion, we presented the presumptive mechanism of hallucination based on the anatomical dysfunction of schizophrenia.

  • PDF

Cardiac Autonomic Control and Neural Arousal as Indexes of Fatigue in Professional Bus Drivers

  • Lecca, Luigi I.;Fadda, Paolo;Fancello, Gianfranco;Medda, Andrea;Meloni, Michele
    • Safety and Health at Work
    • /
    • v.13 no.2
    • /
    • pp.148-154
    • /
    • 2022
  • Background: Bus driving is a mentally demanding activity that requires prolonged attention to ensure safety. The aim of the study was to assess mental fatigue caused by driving a public bus and to find a profile of workers at higher risk. Methods: We evaluated changes of critical flicker fusion (CFF) (index of central arousal) and heart rate variability (HRV) (index of autonomic balance) in a 6-hour driving shift on a real route, in 31 professional bus drivers, and we tested the influence of personal factors such as sleep quality, BMI, and age. Paired t-test was used to test differences of CFF and HRV between both initial and final phase of driving, while multiple linear regression tested the influence of personal variables on the indexes of mental fatigue. Results: Results showed that CFF significantly decreased after 6 hours of bus driving (41.91 Hz, sd 3.31 vs. 41.15 Hz, sd 3.15; p = 0.041), and heart rate significantly decreased in the final phase of driving, with respect to the initial phase (85 vs. 78 bpm, p = 0.027). Increasing age (beta = -0.729, p = 0.022), risk of obstructive sleep apnea syndrome (beta = -0.530, p = 0.04), and diurnal sleepiness (beta = -0.406, p = 0.017) showed a significant effect on influencing mental fatigue. Conclusion: Elderly drivers at higher risk of sleep disorders are more prone to mental fatigue, when exposed to driving activity. Monitoring indexes of central arousal and autonomic balance, coupled with the use of structured questionnaires can represent a useful strategy to detect profile of workers at higher risk of mental fatigue in such duty.

Effect of Mandibular Repositioning Device on Airway Size and Airway Collapsibility in Obstructive Sleep Apnea Syndrome : Cine CT during Sleep (수면무호흡증 환자에서 Mandibular Repositioning Device가 Airway size와 Airway Collapsibility에 미치는 효과)

  • Hong, Seung-Bong;Kyung, Seung-Hyun;Han, Hyun-Jung;Na, Dong-Kyu;Son, Young-Ik;Park, Young-Chel
    • Sleep Medicine and Psychophysiology
    • /
    • v.6 no.2
    • /
    • pp.110-115
    • /
    • 1999
  • Objectives: To investigate the effect of mandibular repasitioning device on airway sige and airway collapsibility in patients with obstructive sleep apnea syndrome(OSAS). Methods: Cine CT with polysomnographic monitoring was performed during sleep in nine(OSAS) patients before and after manibular repositioning device(MRD) application. Axial CT images were obtained in five upper airway levels(retropalatal-high, retroalatal-low, retroglossal, epiglottis, and hypopharynx levels). In each airway level, one axial CT image was obtained during sleep apnea period and 10 serial axial CT images were scanned every 1 second during normal sleep breathing. After wearing MRD, all CT images were obtained by the same method. The cross-sectional areas of airway were measured by automatic tracing method. The changes of minimum airway size and maximum airway size after MRD were evaluated. The airway collapsibility was calculaed before and after MRD. Results: During sleep apnea, the airway of retropalatal-low level was the most frequently narrowest site. During normal sleep breahing the minimum airway size was increased significantly after MRD at retropalatal-low level(p=0.011). The mean airway collapsibility was the highest at retropalatal-low level. MRD decreased the airway collapsibility significantly at retropalatal-low level(p=0.021) and epiglottis level(p=0.038). Conclusions: The enlargement of the minimum airway size and decreased airway collapsibility may be the therapeutic mechanism of MRD in obstructive sleep apnea.

  • PDF

The Comorbidity of Periodic Limb Movements Disorder in Patients with Sleep-Related Breathing Disorder (수면관련 호흡장애 환자에서의 수면중 주기성 사지운동장애의 동반이환율)

  • Yang, Chang-Kook;Son, Choon-Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.5
    • /
    • pp.1039-1046
    • /
    • 1998
  • Background: Sleep-related breathing disorders(SRBD) and periodic leg movements disorder(PLMD) are both common, and are considered as separate sleep disorders. However, both disorders show high comorbidity. SRBD and PLMD can result in excessive daytime sleepiness and insomnia due to frequent sleep fragmentation. So, it is very important to consider the presence of PLMD, when we are dealing with the diagnosis and management of SRBD. The objectives of this study were to determine the incidence of PLMD in patients with SRBD, and to describe any differences between patients with and without PLMD. Method: The authors reviewed the sleep recordings of 106 patients with a final diagnosis of SRBD(obstructive sleep apnea or upper airway resistance syndrome), who underwent full nocturnal polysomnography, including the monitoring of the anterior tibialis electromyogram. All sleep records were recorded and scored using the standard criteria. The data was analyzed by the student t-test. Result: 106 patients(M=76, F=30) were included in the analysis. Data revealed a mean age of $49.5{\pm}13.6$ years, a respiratory disturbance index(RDI) of $22.3{\pm}25.4$/hour sleep, a lowest oxygen saturation of $84.9{\pm}11.3%$, a maximal esophageal pressure of $-41.0{\pm}19.1cmH_2O$, and PLM index(PLMI) of $13.1{\pm}22.4$movements/hour sleep. Forty four percent(47 of 106 patients) had a PLMI of greater than 5 on this study. The mean age of the patients with PLMD was significantly higher than that of the patients without PLMD(p<0.005). Female patients with SRBD accompanied more PLMD(p<0.05). The apnea index of the patients with PLMD was significantly lower than that of the patients without PLMD(p<0.01). The percentage of stage 1 sleep in the patients with PLMD was significantly lower than that of the patients without PLMD(p<0.05). Conclusion: The prevalence of PLMD in the patients with SRBD was high at 44.3%. The patients with PLMD were older and had more high RDI in comparison to the patients without PLMD, which was consistent with previous findings. The authors recommend that more careful consideration of PLMD is required when diagnosing and treating SRBD.

  • PDF

A Respiratory Rate Monitoring System during Sleep using a Depth Camera (깊이 카메라를 이용한 수면중 호흡률 모니터링 시스템)

  • Moon, Chanki;Nam, Yunyoung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.04a
    • /
    • pp.561-563
    • /
    • 2015
  • 본 논문은 깊이 카메라를 이용하여 수면중에 가슴의 움직임만으로 호흡률을 예측하는 시스템을 제안한다. 카메라는 취침하는 사람의 머리 위에 위치하였으며, 취침하는 사람의 가슴 주변을 관심 영역으로 지칭하여 깊이 값의 변화를 추출하여 노이즈를 제거한 후 FFT를 계산하여 호흡률을 계산하였다. 실행에서 10명의 지원자를 대상으로 0.1 Hz 부터 0.4 Hz까지 측정하여 약 98%의 정확률을 얻었다.

Performance Evaluation of Traffic Adaptive Sleep based MAC in Clustered Wireless Sensor Networks (클러스터 기반 무선 센서 망에서 트래픽 적응적 수면시간 기반 MAC 프로토콜 성능 분석)

  • Xiong, Hongyu;So, Won-Ho
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.48 no.5
    • /
    • pp.107-116
    • /
    • 2011
  • In this paper, a traffic adaptive sleep based medium access control (TAS-MAC) protocol for wireless sensor networks (WSNs) is proposed. The protocol aims for WSNs which consist of clustered sensor nodes and is based on TDMA-like schema. It is a typical schedule based mechanism which is adopted in previous protocols such as LEACH and Bit-Map Assisted MAC. The proposed MAC, however, considers unexpected long silent period in which sensor nodes have no data input and events do not happen in monitoring environment. With the simple traffic measurement, the TAS-MAC eliminates scheduling phases consuming energy in previous centralized approaches. A frame structure of the protocol includes three periods, investigation (I), transmission (T), and sleep-period (S). Through the I-period, TAS-MAC aggregates current traffic information from each end node and dynamically decide the length of sleep period to avoid energy waste in long silent period. In spite of the energy efficiency of this approach, the delay of data might increase. Thus, we propose an advanced version of TAS-MAC as well, each node in cluster sends one or more data packets to cluster head during the T-period of a frame. Through simulation, the performance in terms of energy consumption and transmission delay is evaluated. By comparing to BMA-MAC, the results indicate the proposed protocol is more energy efficient with tolerable expense in latency, especially in variable traffic situation.

U-healthcare Based System for Sleeping Control and Remote Monitoring (u-헬스케어기반의 수면제어 및 원격모니터링 시스템)

  • Kim, Dong-Ho;Jeong, Chang-Won;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.8 no.1
    • /
    • pp.33-45
    • /
    • 2007
  • Using switches and sensors informing the current on or off state, this paper suggests a sleeping control and remote monitoring system that not only can recognize the sleeping situations but also can control for keeping an appropriate sleeping situation remotely, And we show an example that this system is applied to the healthcare sleeping mat, Our system comprises the following 3 parts: a part for detecting the sleeping situations, a part for extracting sensing data and sending/receiving the relating situated data, and a part controlling and monitoring the all of sleeping situations. In details, in order to develop our system, we used the touch and pressure-sensitive sensors with On/Off functions for a purpose of the first part, The second part consists of the self-developed embedded board with the socket based communication as well as extracting real-time sensing data. And the third part is implemented by service modules for providing controlling and monitoring functions previously described. Finally, these service modules are implemented by the TMO scheme, one of real-time object-oriented programming models and the communications among them is supported using the TMOSM of distributed real-time middleware.

  • PDF