• Title/Summary/Keyword: Slack angle

Search Result 11, Processing Time 0.027 seconds

Quantitative Evaluation of Gastrocnemius Medialis Stiffness During Passive Stretching Using Shear Wave Elastography in Patients with Parkinson's Disease: A Prospective Preliminary Study

  • Lu Yin;Lijuan Du;Yuanzi Li;Yang Xiao;Shiquan Zhang;Huizi Ma;Wen He
    • Korean Journal of Radiology
    • /
    • v.22 no.11
    • /
    • pp.1841-1849
    • /
    • 2021
  • Objective: To prospectively investigate the feasibility of shear wave elastography (SWE) as a new quantitative and objective method for evaluating the stiffness of the gastrocnemius medialis (GM) muscle during passive stretching in patients with Parkinson's disease (PD). Materials and Methods: SWE of the GM muscle was performed in 28 patients with PD [13 female and 15 male; mean age ± standard deviation (SD): 63.0 ± 8.5 years] and 12 healthy controls (5 female and 7 male; mean age ± SD: 59.3 ± 6.4 years) during passive ankle rotation. A Young's modulus-ankle angle curve was constructed. The GM slack angle and baseline Young's modulus (E0) were compared between the markedly symptomatic and mildly symptomatic sides of patients with PD, and healthy controls. Additionally, the correlation between the GM slack angle and the severity of rigidity, and the observer reproducibility of SWE in determining the GM slack angle were evaluated. Results: The GM slack angle was smaller on both the markedly and mildly symptomatic sides in patients with PD than in healthy controls (mean ± SD of -29.13° ± 3.79° and -25.65° ± 3.39°, respectively, vs. -21.22° ± 3.52°; p < 0.001 and p = 0.006, respectively). Additionally, in patients with PD, the GM slack angle on the markedly symptomatic side was smaller than that on the mildly symptomatic side (p = 0.003). The E0 value was lower on both the markedly and mildly symptomatic sides in patients with PD than in healthy controls (mean ± SD of 10.11 ± 2.85 kPa and 10.08 ± 1.88 kPa, respectively, vs. 12.23 ± 1.02 kPa; p = 0.012 and p < 0.001, respectively). However, no significant difference was found between the markedly and mildly symptomatic sides in patients with PD (p = 0.634). A negative linear relationship was observed between the GM slack angle and lower limb rigidity score on the markedly symptomatic side in patients with PD (r = -0.719; p < 0.001). The intraclass correlation coefficients for observer reproducibility of SWE ranged from 0.880 to 0.951. Conclusion: The slack angle determined by SWE may be a useful quantitative and reproducible method for evaluating muscle stiffness in patients with PD.

Generator Penalty Factor Calculation including Slack Bus by Reference Angle Re-Specification (위상각 기준모선의 이동에 의한 Slack 모선을 포함한 모든 발전기의 Penalty 계수 계산방법)

  • Lee, Sang-Joong;Kim, Kern-Joong
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.49-51
    • /
    • 2000
  • ln this paper, a method by which penalty factors of all generators including slack bus can be directly derived is presented. With a simple re-assignment of angle reference bus to a bus where no generation exists, penalty factors for slack bus is obtained without any physical assumption. While previous Jacobian-based techniques for generator penalty factor calculation have been derived with basis upon reference bus, proposed method are not dependent on reference bus and calculated penalty factors can be substituted directly into the general ELD equation to compute the economic dispatch. Equations for system loss sensitivity, penalty factors and optimal generation allocation are solved simultaneously in normal power flow computation.

  • PDF

A New Calculation of Generator Penality Factors through transposition of System Angle Reference (위상각기준의 이동을 통한 새로운 패널티 계수의 계산방법)

  • Lee, Sang-Joong
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.1
    • /
    • pp.1-5
    • /
    • 2001
  • In this paper, a new method for calculating the penalty factors of all generators including the slack bus is presented. A simple transposition of the angle reference, from the conventional slack bus to another bus where no generation exists, enables the derivation of the loss sensitivity of the slack bus. Penalty factors are obtained without any physical assumption through a simple substitution of the bus loss sensitivities. Penalty factors calculated by proposed method are not dependent on reference bus and can also be directly substituted into the general ELD equation for computing the optimal dispatch. Equations for loss sensitivities, Penalty factors and ELD are calculated simultaneously in normal power flow computation. A case study on a test system has proved the effectiveness of the proposed' angle reference transposition' method.

  • PDF

Some Properties on Jacobian Matrix (전력조류방정식과 자코비안 행렬의 성질에 대하여)

  • Lee, Sang-Joong;Yang, Seong-Deog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.251-253
    • /
    • 2004
  • Though the reference angle has been specified conventionally on the slack bus, it can be specified on my bus in the system without changing power flow solutions. This paper describes that the loss sensitivity of the salk bus can be obtained through an angle reference transposition. A concept of two reference buses, consisting of "power slack bus"

  • PDF

Development of a Model for the Estimation of Knee Joint Moment at MVC (MVC 상태에서의 무릎관절 모멘트 추정을 위한 모델 개발)

  • Nam, Yoon-Su;Lee, Woo-Eun
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.3
    • /
    • pp.222-230
    • /
    • 2008
  • This paper introduces a method of estimating the knee joint moment developed during MVC. By combining the Hill-type muscle model and analytic results on moment arm and musculotendon length change as a function of hip and knee joint angle, the knee joint moment at a specific knee joint angle during MVC is determined. Many differences between the estimated results and the experimental data are noted. It is believed that these differences originate from inaccurate information on the muscle-tendon parameters. The establishment of exact values for the subject's muscle parameters is almost impossible task. However, sensitivity analysis shows that the tendon slack length is the most critical parameter when applying the Hill-type muscle model. The effect of a change of this parameter on the muscle length force relationship is analyzed in detail.

Improvement of Variable Renewable Energy Penetration of Stand-Alone Microgrid Hosting Capacity by Using Energy-Storage-System Based on Power Sensitivity

  • CHOI, DongHee
    • Journal of Advanced Information Technology and Convergence
    • /
    • v.10 no.2
    • /
    • pp.91-101
    • /
    • 2020
  • Recently, the demand for high penetration of variable renewable energy (VRE) penetration in a power system is increased. In consequence, distribution systems including microgrids confront the increased installation of VRE-based distributed generation. Despite of the high demand of VRE-based distributed generation in a distribution system, the installation of photovoltaic (PV) system in a distribution system has been restricted by various problems. In other words, the hosting capacity for high VRE penetration in a distribution system is limited. This paper analyzes the improvements of hosting capacity VRE penetration of stand-alone microgrid (SAMG) with energy storage system (ESS) by considering virtual-slack (VS) control based on power sensitivity. With the pre-defined power sensitivity, the ESS operates as virtual slack in the SAMG by controlling its bus voltage and phase angle indirectly. Therefore, the ESS enables the increase of VRE penetration in the SAMG. The proposed VS control is realized by analyzing the ESS as a virtual slack in power flow analysis based on power sensitivity. Then its validity is demonstrated with the case study on the SAMG in South Korea with practical data.

Development of Prototype of Knit Slacks for Middle-aged Women (중년 여성의 니트 슬랙스 기본 원형 개발)

  • Lee, Jung-Jin
    • Journal of Fashion Business
    • /
    • v.19 no.4
    • /
    • pp.153-167
    • /
    • 2015
  • This paper proposes knit slacks patterns by lower body shape of middle-aged women. In addition, this paper aims to propose a design method for a prototype of nice knit slacks using the properties of knitwear. To select basic woven slack patterns which would be used in designing prototype of knit slacks for middle-aged women, two industrial slack patterns and two educational slack patterns were collected, and lab coats were prefabricated using muslin. Then, a shape test was performed by an evaluation board which consisted of eight experts who majored in Clothing Construction. Using blended yarn (1/17's) with 64% wool, 23% rayon and 13% nylon, 12G knit slacks in plain stitch were made. In terms of waist circumference of knit slacks, the front and the back were set to W/4+1+2(D) and W/4-1+2(D), respectively, with 1cm of difference using waist circumference (Omphalion) to cover the abdominal circumference. To make the front-back width of the side line even, the front waist circumference was increased by 1cm. The ease of hip circumference was set to 4cm in total with H/4+1+0.8 in front and H/4+1-0.8 in the back (0.8cm in difference). Crotch length was set by adding 3cm (width of waist belt) after deducting crotch height from waist height (Omphalion). The center front angle was shifted by 1cm while the center back angle was shifted from the center front to the side line by 5cm.

Belt Tension Distribution for Belt Contact Abrasive Belt Drive (벨트접촉식 연삭 벨트구동의 벨트 장력 분포)

  • 임영호;김현수;안효원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.5
    • /
    • pp.837-846
    • /
    • 1989
  • Belt tension distribution for an abrasive blet grinding was investigated analytically and experimentally for (1) slack side and (2) tight side blet grinding. Classical Eytelwein equation was used to predict the belt tension distribution with dividing contact angles into (1) inactive and (2) active angles. General friction theory was modified based on the friction force between the belt and the support in the grinding contact area that was obtained by experiments. It was found that analytical results were in good agreement with the experimental results. Also, the tight side belt grinding was recommended since it could carry out more grinding load than that of slack side belt grinding.

Inverse analysis of erection process for prismatic tensegrity structures with redundant cables

  • Pei Zhang;Huiting Xiong;Jingjing Yang;Jiayan Liu
    • Steel and Composite Structures
    • /
    • v.49 no.2
    • /
    • pp.125-141
    • /
    • 2023
  • Firstly, a new kind of prismatic tensegrity structures with redundant cables is defined, the topology, geometry and forming conditions of which are introduced further. The development of its mechanical properties including self-stress states and structural stiffness with the increment of the twist angle is also investigated carefully. Combined with the topology of this kind of structures, a reasonable erection scheme is proposed, in which some temporary lifting points need to be set and two groups of vertical cables are tensioned in batches. Then, a simplified dynamic relaxation method is employed to track the erection process inversely, which aims to predict each intermediate equilibrium state during the construction, and give the key structural parameters that can effectively guide the construction. The removal of the active cables, the relaxation or tension of the passive cables are simulated by controlling their axial stiffness, so that the structural composition as well as the serial numbers of the elements always keep invariant regardless of the withdrawal of the slack cables. The whole analysis process is clear in concept, simple to implement and easy to popularize. Finally, several examples are given to verify the practicability and effectiveness of the proposed method further.

Derivation of Damping-reflected Energy Functions in COI Formulation for Direct Analysis of Transient Stability

  • Park, Byoung-Kon;Kwon, Yong-Jun;Lee, Jong-Gi;Moon, Young-Hyun
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.3
    • /
    • pp.134-140
    • /
    • 2004
  • This paper presents an improved group of energy functions reflecting generator damping effects for multi-machine power systems by using Center of Inertia (COI) formulation as an extension of the previous work. Since rotor angles at the Stable Equilibrium Point (SEP) of post-fault systems are generally calculated in COI, system transient energy can be found without assumption of infinite or slack bus, which is a crucial drawback of the absolute rotor angle frame approach. The developed energy functions have a structure preserving property with which it is very flexible to incorporate various models of power system components, especially various load and generator models. The proposed damping-reflected energy functions are applied to the Potential Energy Boundary Surface (PEBS) method, one of the direct methods. Numerical simulation of WSCC 9-bus shows that conservativeness of the PEBS method can be considerably reduced.