• 제목/요약/키워드: Slab in the Steel Structure

검색결과 131건 처리시간 0.029초

반복하중을 받는 원자력 구조물 합성 바닥판의 구조적 거동 (Structural Behavior of Composite Slab toNuclear Power Structure under Reversed Cyclic Loads)

  • 김정혁;김강식;김우범;정하선;이광수;신성우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.629-634
    • /
    • 2000
  • Comparing with single structure constructed with reinforced concrete or steel, composite structures have a great advantage. However, in case of nuclear power structure, the application of a conventional single structure (reinforced concrete or steel structure) inflicts a heavy loss on a economical and constructive efficiency. But, the application of composite slab to nuclear power structure could compensate these deficiency. Therefore, in this study, the structural behavior of composite slab in nuclear power structure is observed to assure economical and constructive efficiency.

  • PDF

강섬유보강콘크리트 연속슬래브 휨성능의 장기거동 특성 (Long-Term Characteristics on Flexural Performance of Steel Fiber Reinforced Concrete Continuous Slab)

  • 홍건호;정승원
    • 대한건축학회논문집:구조계
    • /
    • 제35권10호
    • /
    • pp.163-170
    • /
    • 2019
  • In spite of various advantages, steel fiber reinforced concrete is still limited in its use due to the insufficient research results on the structural performance and design criteria. This study evaluated the long-term behavior of the steel fiber reinforced concrete slabs by long-term loading experiments based on the short-term load bearing capacity of steel fiber reinforced concrete slabs obtained from previous studies. In this study, long-term loading experiments were carried out on Total four 2-span continuous slab specimens were tested for examining the long-term behavior of steel fiber reinforced concrete members. Long-term behavior characteristics of members were evaluated by measuring the long-term deflection, drying shrinkage, the number and width of cracks. Experimental results showed that the instant deflection of the steel fiber reinforced concrete slab is about 50% of the normal reinforced concrete slab. And, it was analyzed that the long-term deflection of the specimen using steel fiber reinforced concrete was about 10~20% lower than that of normal concrete by the long-term deflection over 100 days. In addition, the slab specimen using steel fiber reinforced concrete was evaluated to have just 70% of the number and width of cracks compared with normal concrete specimens.

데크플레이트를 사용한 강섬유보강콘크리트 슬래브의 구조성능 평가 (Structural Performance Evaluation on the Slab with the SFRC and Steel Deck-plate)

  • 홍건호;채병민
    • 대한건축학회논문집:구조계
    • /
    • 제34권7호
    • /
    • pp.3-10
    • /
    • 2018
  • Steel fiber reinforced concrete can improve the resistance to cracking by adding steel fibers when mixing concrete. It can reduce the temperature and shrinkage cracks, and its flexural performance can be improved by increasing the effective moment of inertia. In this study, the deck-plate was used to replace the concrete form and reinforcing bars, and the steel fiber reinforced concrete was used to control the shrinkage and temperature cracks, and improve the flexural performance of the slab. Total 9 slab specimens were tested for analyzing the structural performance and serviceability. As a results, flexural capacity of the slab with deck-plate was evaluated to be superior to that of the normal reinforced concrete slab specimens with the same tensile reinforcement. The steel fiber reinforced concrete was found to have about 8% flexural capacity increase depending on the steel fiber content $15.7kg/m^3$. Also, in terms of flexural stiffness, the specimens using steel fiber reinforced concrete for the same parameters were evaluated to have a stiffness increase of about 30% compared with the case of using ordinary concrete. Especially, it was found that the stiffness of the test results was significantly higher than the analytical result because the increase of the tensile strength of the steel fiber reinforced concrete is not reflected in the current structural code.

Punching performance of RC slab-column connections with inner steel truss

  • Shi, Qingxuan;Ma, Ge;Guo, Jiangran;Ma, Chenchen
    • Advances in concrete construction
    • /
    • 제14권3호
    • /
    • pp.195-204
    • /
    • 2022
  • As a brittle failure mode, punching-shear failure can be widely found in traditional RC slab-column connections, which may lead to the entire collapse of a flat plate structure. In this paper, a novel RC slab-column connection with inner steel truss was proposed to enhance the punching strength. In the proposed connection, steel trusses, each of which was composed of four steel angles and a series of steel strips, were pre-assembled at the periphery of the column capital and behaved as transverse reinforcements. With the aim of exploring the punching behavior of this novel RC slab-column connection, a static punching test was conducted on two full-scaled RC slab specimens, and the crack patterns, failure modes, load-deflection and load-strain responses were thoroughly analyzed to explore the contribution of the applied inner steel trusses to the overall punching behavior. The test results indicated that all the test specimens suffered the typical punching-shear failure, and the higher punching strength and initial stiffness could be found in the specimen with inner steel trusses. The numerical models of tested specimens were analyzed in ABAQUS. These models were verified by comparing the results of the tests with the results of the analyzes, and subsequently the sensitivity of the punching capacity to different parameters was studied. Based on the test results, a modified critical shear crack theory, which could take the contribution of the steel trusses into account, was put forward to predict the punching strength of this novel RC slab-column connection, and the calculated results agreed well with the test results.

SC구조 벽-바닥 접합부의 내력 및 거동 특성 (Behavior and Strength of Wall-Slab Connection in SC Structure)

  • 김형국;김우범;김원기
    • 한국강구조학회 논문집
    • /
    • 제20권2호
    • /
    • pp.347-354
    • /
    • 2008
  • SC 구조는 시공 및 제작성이 우수하여 최근 국내외 원자력 발전소 건설에 적용되고 있는 구조이다. SC 구조의 벽 -바닥 접합부가 갖는 전단력 전달기구를 확인하기 위하여 4개의 실험체에 대하여 실험을 수행하고, 접합부의 거동특성을 분석하였다. 이를 바탕으로 접합부의 전단내력 평가를 위한 해석적 연구를 수행하였다. 그 결과, 실험 결과와 해석결과 간의 근접성을 확인하였고, 접합부의 내력 및 파괴모드를 도출하였다. 그리고 전단플레이트의 두께와 벽면 마찰력의 변화가 접합부 전단내력에 미치는 영향을 파악한 결과, 제안한 접합부 내력식이 보수적인 값을 제시하고 있음을 확인하였다.

Interface friction in the service load assessment of slab-on-girder bridge beams

  • Seracino, R.;Kerby-Eaton, S.E.;Oehlers, D.J.
    • Steel and Composite Structures
    • /
    • 제5권4호
    • /
    • pp.259-269
    • /
    • 2005
  • Many slab-on-girder bridges around the world are being assessed because they are approaching the end of their anticipated design lives or codes are permitting higher allowable loads. Current analytical techniques assume that the concrete and steel components act independently, typically requiring full-scale load testing to more accurately predict the remaining strength or endurance of the structure. However, many of the load tests carried out on these types of bridges would be unnecessary if the degree of interaction resulting from friction at the steel-concrete interface could be adequately modeled. Experimental testing confirmed that interface friction has a negligible effect on the flexural capacity of a slab-on-girder beam however, it also showed that interface friction is significant under serviceability loading. This has led to the development of an improved analytical technique which is presented in this paper and referred to as the slab-on-girder mixed analysis service load assessment approach.

파이프 재질 및 형태에 따른 에너지 슬래브의 현장 열교환 성능 평가 (Evaluation on in-situ Heat Exchange Efficiency of Energy Slab According to Pipe Materials and Configurations)

  • 이석재;오광근;한신인;박상우;최항석
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권4호
    • /
    • pp.1-7
    • /
    • 2017
  • The energy slab is a ground coupled heat exchanger equipped in building slab structures, which represents a layout similar to the horizontal ground heat exchanger (GHEX). The energy slab is installed as one component of the floor slab layers in order to utilize the underground structure as a hybrid energy structure. However, as the energy slab is horizontally arranged, its thermal performance is inevitably less than the conventional vertical GHEXs. Therefore, stainless steel (STS) pipes are alternatively considered as a heat exchanger instead of high density polyethylene (HDPE) pipes in order to enhance thermal performance of GHEXs. Moreover, not only a floor slab but also a wall slab can be utilized as a heat-exchangeable energy slab in order to maximize the use of underground space effectively. In this paper, four field-scale energy slabs were constructed in a test bed, which consist of the STS and HDPE pipe, and a series of thermal response tests (TRTs) was conducted to evaluate relative heat exchange efficiency per unit pipe length according to the pipe material and the configuration of energy slabs. The energy slab equipped with the STS pipe shows higher thermal performance than the energy slab with the HDPE pipe. In addition, thermal performance of the wall-type energy slab is almost equivalent to the floor-type energy slab.

Strengthening of steel-concrete composite beams with composite slab

  • Subhani, Mahbube;Kabir, Muhammad Ikramul;Al-Amer, Riyadh
    • Steel and Composite Structures
    • /
    • 제34권1호
    • /
    • pp.91-105
    • /
    • 2020
  • Steel-concrete composite beam with profiled steel sheet has gained its popularity in the last two decades. Due to the ageing of these structures, retrofitting in terms of flexural strength is necessary to ensure that the aged structures can carry the increased traffic load throughout their design life. The steel ribs, which presented in the profiled steel deck, limit the use of shear connectors. This leads to a poor degree of composite action between the concrete slab and steel beam compared to the solid slab situation. As a result, the shear connectors that connects the slab and beam will be subjected to higher shear stress which may also require strengthening to increase the load carrying capacity of an existing composite structure. While most of the available studies focus on the strengthening of longitudinal shear and flexural strength separately, the present work investigates the effect of both flexural and longitudinal shear strengthening of steel-concrete composite beam with composite slab in terms of failure modes, ultimate load carrying capacity, ductility, end-slip, strain profile and interface differential strain. The flexural strengthening was conducted using carbon fibre reinforced polymer (CFRP) or steel plate on the soffit of the steel I-beam, while longitudinal shear capacity was enhanced using post-installed high strength bolts. Moreover, a combination of both the longitudinal shear and flexural strengthening techniques was also implemented (hybrid strengthening). It is concluded that hybrid strengthening improved the ultimate load carrying capacity and reduce slip and interface differential strain that lead to improved composite action. However, hybrid strengthening resulted in brittle failure mode that decreased ductility of the beam.

강섬유보강 패널구조의 보강효과 분석 및 인성평가 기법 (Steel Fiber Reinforcing Effect Analysis of Slab Panel Structure and Assessment Technics of Toughness)

  • 전찬기;박선규
    • 콘크리트학회지
    • /
    • 제11권2호
    • /
    • pp.209-220
    • /
    • 1999
  • 터널의 숏크리트 라이닝이나 포장 콘크리트 보강용으로 요접철망(wire mesh)을 대신해서 강섬유가 사용되고 있다. 본 연구에서는 강섬유 보강으로 인한 인성평가 대상 구조물을 slab panel 구조($60{\times}60{\times}10$cm)로 하고, 강섬유 혼입률은 콘크리트 용적의 0.5% ~ 2%로 다양화하였다. 이 때 사용한 강섬유는 Dramix ZC type으로 직경은 0.8mm, 길이는 60mm이다. 강섬유 효과의 상대평가를 위한 용접철망(wire mesh)보강은 상면, 하면, 상하면 보강으로 하였다. 이들 실험 결과를 각국의 인성 평가 방법으로 비교 검토한 결과 슬래브(slab) 시험체 적용을 위한 EFNARC의 방법은 25mm의 처짐까지 측정하는 것이 너무 큰 것으로 평가되었고, 보의 휨인성 평가법을 적용하여 검토한 결과에서는 Johnston(II)방법에 의한 $I_{5.5}$ 가장 적절하였으며, JCI-SF4방법에서 지간의 1/150까지 측정하는 것은 너무 작았다. 또한 강섬유로 용접철망(wire mesh)을 효과적으로 대치할 수 있음을 알 수 있었고, 인성효과에 유용한 강섬유 혼입량은 0.5% ~ 1%범위에 있는 것으로 나타났다.

Vibration performance of composite steel-bar truss slab with steel girder

  • Liu, Jiepeng;Cao, Liang;Chen, Y. Frank
    • Steel and Composite Structures
    • /
    • 제30권6호
    • /
    • pp.577-589
    • /
    • 2019
  • In this study, on-site testing was carried out to investigate the vibration performance of a composite steel-bar truss slab with steel girder system. Ambient vibration was performed to capture the primary vibration parameters (natural frequencies, damping ratios, and mode shapes). The composite floor possesses low frequency (< 10 Hz) and damping (< 2%). Based on experimental, theoretical, and numerical analyses on natural frequencies and mode shapes, the boundary condition of SCSC (i.e., two opposite edges simply-supported and the other two edges clamped) is deemed more reasonable for the composite floor. Walking excitations by one person (single excitation), two persons (dual excitation), and three persons (triple excitation) were considered to evaluate the vibration serviceability of the composite floor. The measured acceleration results show a satisfactory vibration perceptibility. For design convenience and safety, a crest factor ${\beta}_{rp}$ describing the ratio of peak acceleration to root-mean-square acceleration induced from the walking excitations is proposed. The comparisons of the modal parameters determined by ambient vibration and walking tests reveal the interaction effect between the human excitation and the composite floor.