• 제목/요약/키워드: Slab effect

검색결과 578건 처리시간 0.035초

개선된 미소면 모델을 적용한 매스콘크리트 기초슬래브의 초기균열거동 해석 (Early Age Cracking Analysis of Massive Concrete Base Slab with Enhanced Microplane Model)

  • 이윤;김진근;우상균;송영철;이성태
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.458-461
    • /
    • 2006
  • Early age cracking of concrete is a widespread and complicated problem, and diverse applications in practical engineering have focused on this issue. Since massive concrete base slab composes the infrastructure of other concrete structures such as pier, concrete dam, and high rise buildings, early age cracking of that is considered as a crucial problem. In this study, finite element analysis (FEA) implemented with the age-dependent microplane model was performed. For a massive concrete base slab, cracking initiation and propagation, and deformation variation were investigated with concrete age. In massive concrete slab, autogenous shrinkage increases the risk of early age cracking and it reduces reinforcement effect on control of early age cracking. Gradual crack occurrence is experienced from exterior surface towards interior of the slab in case of combined hydration heat and autogenous shrinkage. FEA implemented with enhanced microplane model successfully simulates the typical cracking patterns due to edge restraint in concrete base slab.

  • PDF

슬래브의 동특성과 중량충격음의 상관관계에 관한 연구 (Research about correlation of slab vibration mode and heavy-weight floor impact sound)

  • 정진연;이상우;임정빈;정갑철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.839-843
    • /
    • 2008
  • Receiving room's floor impact sound level is been influenced to various factor of slab thickness, room size, structure etc. This study examined the noise of upper part slab and room mode in receiving room to be importance factor that influence in receiving room level among this factors. According to this study, vibration mode in slab and room mode are concentrated on frequency that is high level relatively. This causes bad effect in floor impact sound level. Therefore, method to reduce floor impact sound level is to change vibration mode using slab upper part's resilient material or reduce room mode in receiving room.

  • PDF

질량형 댐퍼를 이용한 바닥판의 진동 및 소음 저감 (Vibration and Noise Control of Slab Using the Mass Type Damper)

  • 황재승;박성철;김홍진
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.597-602
    • /
    • 2007
  • It is proposed to analyze the vibration of slab with MTMD and vibration-induced noise. Substructure synthesis is introduced to develope the interaction between the slab and MTMD which are defined in different space and acoustic power is obtained from the velocity field of slab. Numerical analysis is performed to show that the vibration and noise of slab can be reduced by MTMD. A living room of wall type apartment including the wall and MTMD is modeled and analyzed by FEM program Numerical analysis shows that the vibration and noise control effect is different depending on the location and mass ratio of MTMD. Futhermore, noise is more effectively reduced when the vibration of higher modes of slab are reduced rather than lower modes.

  • PDF

프리캐스트 콘크리트 포장 시공 시 최적 슬래브 리프팅 위치 (Optimum Slab-Lifting Positions for Precast Concrete Pavement Construction)

  • 김성민;조병휘;한승환
    • 한국도로학회논문집
    • /
    • 제9권2호
    • /
    • pp.27-37
    • /
    • 2007
  • 본 연구는 프리캐스트 콘크리트 포장 시공을 위하여 공장에서 미리 제작된 콘크리트 슬래브를 리프팅을 할 때 리프팅 위치에 따른 슬래브의 응력변화를 기준으로 슬래브의 손상을 최소화할 수 있는 가장 안전한 최적 리프팅 지점을 선정하기 위하여 수행되었다. 리프팅 시 슬래브의 응력분포를 분석하기 위하여 유한요소법을 이용한 모델을 사용하였으며 슬래브 규격은 시험시공에서 사용한 크기를 적용하였다. 리프팅은 항상 슬래브의 수직방향으로 수행하지는 않기 때문에 수직으로 리프팅 하였을 때와 $60^{\circ},\;30^{\circ}$로 경사각을 주어 리프팅 하였을 때의 응력변화 특성을 분석하였다. 또한 리프팅 지점은 항상 슬래브의 중간 깊이인 중립축의 위치가 아니기 때문에 중립축으로부터 7.5cm. 15cm만큼 수직편심을 주어 리프팅하였을 때의 응력변화 특성도 분석하였다. 그리고 실제 시공 시 지점부분에 보강을 하는 것을 염두하여 지점부 응력집중현상을 무시한 경우와 보강이 없을 경우의 응력집중현상을 고려한 경우로 나누어 분석하였다. 이러한 해석을 통해 리프팅 경사각과 편심에 따른 최적 리프팅 위치를 선정하였으며 미국의 PCI기준과도 비교 분석하였다.

  • PDF

지반위에 놓인 콘크리트 슬래브의 수직하중에 대한 슬래브 하부의 수평 저항의 영향 분석 (Effect of Horizontal Resistance at Slab Bottom on Behavior of Concrete Slabs-on-Grade under Vertical Loads)

  • 심재수;김성민
    • 한국도로학회논문집
    • /
    • 제7권4호
    • /
    • pp.141-150
    • /
    • 2005
  • 지반위에 놓인 콘크리트 슬래브가 수직 하중을 받을 때 지반의 전단저항과 슬래브 하부와 지반과의 마찰 등에 의해 생기는 슬래브 하부의 수평저항을 고려하여 지반위에 놓인 콘크리트 슬래브의 거동을 분석하였다. 슬래브 하부의 수평 저항을 고려하기 위한 해석 공식을 유도하였고 퓨리에변환을 이용한 변환영역에서 이러한 공식의 해를 구하였다. 또한 판요소와 쉘요소를 이용한 유한요소법에 의한 모델을 개발하여 수치 해석 결과도 도출하였다. 이러한 해석 공식과 수치해석 모델을 이용한 해석 결과를 비교 분석하였고 매우 비슷한 결과가 도출되는 것을 알 수 있었다. 콘크리트 슬래브의 응력 분포에 슬래브 하부의 수평저항이 미치는 민감성을 여러 가지의 다른 슬래브의 두께, 탄성계수, 그리고 지반의 수직탄성계수 등을 고려하여 분석하였다. 해석 결과에서 슬래브 하부의 수평 저항은 슬래브의 응력에 매우 큰 영향을 미칠 수 있다는 것을 발견하였다.

  • PDF

Unified equivalent frame method for post-tensioned flat plate slab structures

  • Choi, Seung-Ho;Lee, Deuck Hang;Oh, Jae-Yuel;Kim, Kang Su;Lee, Jae-Yeon;Lee, Kang Seok
    • Computers and Concrete
    • /
    • 제20권6호
    • /
    • pp.663-670
    • /
    • 2017
  • The post-tensioned (PT) flat plate slab system is commonly used in practice, and this simple and fast construction method is also considered to be a very efficient method because it can provide excellent deflection and crack control performance under a service load condition and consequently can be advantageous when applying to long-span structures. However, a detailed design guideline for evaluating the lateral behavior of the PT flat plate slab system is not available in current design codes. Thus, typical design methods used for conventional reinforced concrete (RC) flat plate slab structures have inevitably been adopted in practice for the lateral load design of PT flat plate structures. In the authors' previous studies, the unified equivalent frame method (UEFM) was proposed, which considers the combined effect of gravity and lateral loads for the lateral behavior analysis of RC flat plate slab structures. The aim of this study is to extend the concept of the UEFM to the lateral analysis of PT flat plate slab structures. In addition, the stiffness reduction factors of torsional members on interior and exterior equivalent frames were newly introduced considering the effect of post-tensioning. Test results of various PT flat plate slab-column connection specimens were collected from literature, and compared to the analysis results estimated by the extended UEFM.

기초지반강성을 고려한 벽식구조 아파트의 지진응답에 관한 연구 (Study on Seismic Response of Wall-Slab Apartment Building Sturucture Considering the Stiffnesses of a Foundation-Soil System)

  • 김지원
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2000
    • /
    • pp.167-175
    • /
    • 2000
  • Seismic analyses of structures can`t be performed without considering the effect of soil-structure interaction and seismic responses of a structure taking into account the stiffnesses of a foundation-soil system show a significant difference from those with a rigid base. However, current seismic analyses of apartment building structures were carried out assuming a rigid base and ignoring the characteristics of a foundation and the properties of the underlying soil. In this study, seismic analyses of apartment buildings of a particular wall-slab structural type were carried out comparing seismic response spectra of a flexible base with those of a rigid base and UBC-97. Wall-slab type low-rise or mid-height apartment buildings built on the deep soil layer showed a rigid body motion with the reduced seismic responses due to the base isolation effect, indicating that it is too safe but uneconomical to utilize the design spectra of UBC-97 for the seismic analysis of a wall-slab type apartment buildings due to the too conservative design.

  • PDF

슬랩법을 이용한 쌍롤식 박판주조 공정의 열간 압연 해석 (An Analysis of Hot-Rolling in the Twin-Roll Strip Casting Process by using the Slab Method)

  • 심현보
    • 소성∙가공
    • /
    • 제3권1호
    • /
    • pp.63-83
    • /
    • 1994
  • In this paper, the slab method have been applied to investigate the strip casting process in which hot coil is produced from molten steel directly. In the twin roll strip casting process, molten steel supplied by the nozzle cools and solidifies due to the heat extraction effect of the rolls and hot rolling of the solidified shell takes place simultaneously. The analysis of hot rolling has been carried out by using the existing results of solidification analysis for the twin roll strip casting process. The current slab method provides basic design data such as roll separation force, rolling torque, rolling power as well as end dam separation force which are required to design strip caster. The effect of friction on the basic process parameters are investigated also. It is shown that the use of appropriate friction coefficient is important and that the characteristics of hot rolling in the twin-roll strip casting process is quite different from the conventional hot rolling processes.

  • PDF

옥상녹화하중이 LH 공동주택 및 부대복리시설의 옥상층 슬래브 설계에 미치는 영향 (The Effect of Green Roof Load on the Structural Design of Roof Slab of LH Housing and Service Facilities)

  • 이범식;권혁삼;김정곤;김지현
    • 토지주택연구
    • /
    • 제7권1호
    • /
    • pp.53-63
    • /
    • 2016
  • 본 논문은 옥상녹화하중 세 가지 유형(경량형, 중량형, 혼합형)이 한국토지주택공사(이하 LH)에서 공급하는 공동주택과 부대복리시설의 옥상층 슬래브에 미치는 영향을 구조해석과 설계를 통해 평가하고, 이를 토대로 옥상녹화하중이 작용하는 옥상층 슬래브의 구조설계시 활용가능한 배근 가이드 라인을 제시하였다. 구조해석 및 설계결과, 옥상녹화하중의 종류에 관계없이 LH 공동주택의 옥상층 슬래브는 슬래브 주근을 D10 철근 200~250mm 간격으로 배근할 경우 안전하며, 슬래브 두께도 150mm로 적용가능한 것으로 나타났다. 콘크리트 설계강도가 24, 27, 30MPa로 변화하여도 옥상층 슬래브의 슬래브 주근은 D10 철근을 200~250mm 배근하고 슬래브 두께도 150mm가 적용가능한 것으로 나타났다. 옥상녹화하중이 작용하는 부대복리시설의 2방향 슬래브는 토양 종류와 토심 두께에 관계없이 D10철근을 200mm 간격으로 배근하고 슬래브 두께도 150mm로 적용가능한 것으로 나타났다.

공동주택 모델링을 통한 중량충격음 예측에 관한 연구 (The numerical analysis. of heavy weight impact noise for an apartment house)

  • 황재승;문대호;윤영배;홍건호;박홍근;홍성걸
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.527-532
    • /
    • 2008
  • In this study, numerical analysis is performed to investigate the sound radiation characteristics of an apartment house according to the type of the slab system. In order to satisfy the boundary condition of the apartment house, the whole floor is modelled with FEM model for three different structural system: wall, RC, flat slab system. From the analytical results, it Is shown that heavy weight floor impact noise of wail type slab is larger than that of the other slab systems and the noise radiated from the wall have great effect on the sound pressure level. The results also show that the vibration energy of RC or flat slab system is widely distributed over the whole slab, which is main reason that the noise induced by the slab systems is reduced in comparison with wail slab system.

  • PDF