• 제목/요약/키워드: Skull Anteroposterior and Lateral Radiography

검색결과 2건 처리시간 0.017초

Proposed Institutional Diagnostic Reference Levels in Computed and Direct Digital Radiography Examinations in Two Teaching Hospitals

  • Emmanuel Gyan;George Amoako;Stephen Inkoom;Christiana Subaar;Barry Rahman Maamah
    • Journal of Radiation Protection and Research
    • /
    • 제48권1호
    • /
    • pp.9-14
    • /
    • 2023
  • Background: The detectors of both computed radiography (CR) and direct digital radiography (DR) have a wide dynamic range that could tolerate high values of exposure factors without an adverse effect on image quality. Therefore, this study aims to assess patient radiation dose and proposes institutional diagnostic reference levels (DRLs) for two teaching hospitals in Ghana. Materials and Methods: CR and DR systems were utilized in this study from two teaching hospitals. The CR system was manufactured by Philips Medical Systems DMC GmbH, while the DR system was manufactured by General Electric. The entrance skin doses (ESDs) were calculated using the standard equation and the tube output measurements. Free-in-air kerma (µGy) was measured using a calibrated radiation dosimeter. The proposed institutional DRLs were estimated using 75th percentiles values of the estimated ESDs for nine radiographic projections. Results and Discussion: The calculated DRLs were 0.4, 1.6, 3.4, 0.5, 0.4, 1.1, 1.0, 1.2, and 1.7 mGy for chest posteroanterior (PA), lumbar spine anteroposterior (AP), lumbar spine lateral (LAT), cervical spine AP, cervical spine LAT, skull PA, pelvis AP, and abdomen AP, respectively in CR system. In the DR system, the values were 0.3, 1.6, 3.1, 0.4, 0.3, 0.7, 0.6, 0.9, and 1.3 for chest PA, lumbar spine AP, lumbar spine LAT, cervical spine AP, cervical spine LAT, skull PA, pelvis AP, and abdomen AP, respectively. Conclusion: Institutional DRLs in nine radiographic projections have been proposed for two teaching hospitals in Ghana for the first time. The proposed DRLs will serve as baseline data for establishing local DRLs in the hospitals and will be a valuable tool in optimizing patient doses.

디지털 방사선 환경에서 두부 방사선검사 시 진단참고수준 검사조건에 대한 고찰 (A Study on the Diagnostic Reference Level of Skull Radiography in Digital Radiography)

  • 정연진;주영철;홍동희;김상현
    • 한국방사선학회논문지
    • /
    • 제16권7호
    • /
    • pp.897-904
    • /
    • 2022
  • 본 연구의 목적은 디지털 방사선 환경에서 두부 방사선검사 시 진단참고수준(DRL)에서 제시하는 검사 조건과 현재 임상에서 적용하고 있는 검사 조건 적용 시 선량과 화질의 차이 비교를 통해, 디지털 방사선환경에 적절한 두부 방사선검사의 조건에 대해 고찰하고자 한다. 본 연구는 두부모형팬텀을 대상으로 하였으며, 조사 조건은 임상에서 사용하는 조건(Clinic)과 DRL값(DRL75), DRL 평균값(DRLmean)으로 구분하여 실험하였다. 선량은 입사표면선량(ESD)을 측정하였고, 화질은 신호 대 잡음비와 대조도 대 잡음비를 측정하여 비교 분석하였다. 검사 조건 변화에 따른 skull AP ESD의 평균값은 Clinic 1214.03±4.21 µGy, DRL75 301 7.83±8.14 µGy, DRLmean 2283.50±7.09 µGy이었으며, skull Lat. ESD의 평균값은 Clinic 762.79±3.54 µGy, DRL75 2168.57±10.83 µGy, DRLmean 1654.43±6.48 µGy로 통계적으로 유의한 것으로 나타났다(p<0.01). 안와, 상악동, 전두동, 터키안장에서 측정한 SNR과 CNR의 평균값은 통계적으로 유의하였다(p<0.01). 본 연구 결과 임상에서 사용하는 조건이 DRL에 비해 AP는 약 58%, Lat.은 약 70% 정도의 낮은 선량 수치를 나타내었으며, 화질 측면에서 정성적인 차이가 없었다. 본 연구를 통해 디지털 방사선 환경에 적합한 새로운 진단참고수준에 대해 고려해 볼 필요가 있으며, 그에 따른 선량의 저감화가 이루어져야 할 것으로 사료된다.