• Title/Summary/Keyword: Skull A-P projection

Search Result 5, Processing Time 0.022 seconds

A Study on Added Filters for Reduction of Radiation Exposure Dose in Skull A-P Projection (머리부 전후방향촬영 시 방사선피폭선량 저감을 위한 부가여과판에 대한 연구)

  • Lee, Cho-Hee;Lim, Chang-Seon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.7
    • /
    • pp.3117-3122
    • /
    • 2011
  • Skull A-P projections are the bi-product where the ESD (Entrance Surface Dose) for digital radiography is much higher than that conventional screen-film radiography. Therefore, the aim of this study was to reduce radiation doses to patients by using an added filter. This research focuses on the identification of the reduction of exposure to radiation based on the thickness of an added filter when applying the 'Skull A-P Projection' by using the 'Skull Phantom'. Also, an experiment was conducted to evaluate the qualitative decline of images through filtration. The measurement of one's exposed dose to radiation was executed by locating the 'Skull Phantom' on the position of the 'Skull AP,' while changing 16 kinds of added filters from 0.1 mmAl to 0.5 mmCu + 2.0 mmAl in terms of incident and penetrating doses. For the qualitative evaluation of images, a total number of 17 images have been acquired in the 'Skull Phantom' under the same conditions as those for the measurement of one's exposed dose. The acquired images have been evaluated by a radiological specialist. As a result, the images with a diagnostic value have been obtained by using such added filters as the compound filter of 0.2 mmCu +1.0 mmAl. The exposed dose absorbed on the 'Skull Phantom' is about 0.6 mGy. The value is only 12% of 5 mGy, the ESD value acquired on the 'Skull P-A Projection', which is recommended by the International Atomic Energy Agency (IAEA). As a result, depending on the parts of inspection, it is possible to reduce the patient's exposed dosage of radiation considerably by using an appropriate added filter.

A COMPARATIVE STUDY OF RADIOGRAPHIC LANDMARKS OF T.M.J. BY VARIOUS TECHNIQUES (악관절이 방사선상에 의한 비교 연구)

  • Lee Yoo Dong
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.4 no.1
    • /
    • pp.31-37
    • /
    • 1974
  • The author has studied roentgenographic images of temporomandibular articulation using various conventional roentgenographies. The roentgenographic images have obtained by application of the contrast media on the glenoid fossa and condylar head in a human dry skull. Comparing the various roentgenograms by Modified Transcranial projection, A-P T.M. articulation projection, Reverse Towne projection, Mayer projection and Bregma-Menton projection. The author has drawn following results. 1. The sharp radiogaphic details were obtained by all technics used except the Bregma-Menton projection, which seemed to be impractical to the study of T.M.J. because of to be shortened the image of condylar head. 2. The best image of the condyle-fossa relationship was appeared by Modified Transcranial projection and better image was acquired by Orbito-Ramus projection, but there were all inferior in Reverse Towne projection, Mayer projection and Bregma-Menton projection. 3. In all of the above techniques, the radiographic images of condylar head were clear and were appeared to be the convex type in Modified Transcranial projection, the angled type in Orbito-Ramus and Reverse Towne projection, the flat type in Mayer projection and the distorted angled type in Bregma-Menton projection. 4. The radiographic image of condylar head was shortened in Bregma-Menton projection only and was magnified somewhat in other projection.

  • PDF

Study on Optimum Tube Voltage in taking Skull Roentgenography (두부(頭部) 단순촬영시(單純撮影時) 적정(適正)한 관전압(管電壓)에 관(關)한 검토(檢討))

  • Ahn, Bong-Seon;Ko, Shin-Gwan;Park, Young-Sun
    • Journal of radiological science and technology
    • /
    • v.3 no.1
    • /
    • pp.21-27
    • /
    • 1980
  • It is the experimental report by using 17cm, 19cm in thickness water-phantom to investigate optimum tube voltage in taking skull roentgenography. The obtained results are as follows: 1. An adequate kVp for P-A projection is range from 80-90. 2. An adequate kVp for lateral projection is range from 75-85.

  • PDF

A Study on the Comparative Analysis of Images and Doses According to Tube Orientation During Anterior-Posterior Axial Projection Examination of the Skull (머리뼈 전-후 축 방향검사 시 Tube 방향설정에 따른 표면선량과 영상분석에 관한 연구)

  • Jeong, Sung-Hun;Yoo, Je-hyeon;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.301-306
    • /
    • 2021
  • The skull has peripheral organs such as the crystalline lens and thyroid gland, which are highly radiosensitive, but the examination is performed without considering the uneven dose distribution due to the heel effect at the time of the current Skull Town's examination. However, no studies have been conducted on the exposure dose of surrounding organ tissues due to the difference in image density due to the heel effect and the non-uniformity of the dose. Using the cathode (-) and anode (+) set on the Tube to measure the scattered radiation along the Tube direction as a guide, change 30° and 37° in the cathode direction and 30° and 37° in the anode direction. It was given and investigated 5 times to obtain scattered radiation. image measurements were SNR, PSNR, RMSE, and MAE. Measurement results Measurement results of surrounding organ doses when the Tube direction was 30° and 37° The dose was low when the direction was cathodic in all organs (p<0.000). Both cathodes were higher in the image measurements(p<0.04). Continuous research may be needed for diagnostically valuable imaging and minimization of patient exposure dose.

SKELETAL PATTERN ANALYSIS OF FACIAL ASYMMETRY PATIENT USING THREE DIMENSIONAL COMPUTED TOMOGRAPHY (삼차원 전산화 단층촬영술을 이용한 안모 비대칭환자의 골격 분석)

  • Choi, Jung-Goo;Min, Seung-Ki;Oh, Seung-Hwan;Kwon, Kyung-Hwan;Choi, Moon-Ki;Lee, June;Oh, Se-Ri;Yu, Dae-Hyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.6
    • /
    • pp.622-627
    • /
    • 2008
  • In orthognathic surgery, precise analysis and diagnosis are essential for successful results. In facial asymmetric patient, traditional 2D image analysis has been used by lateral and P-A Cephalometric view, Skull PA, Panorama, Submentovertex view etc. But clinicians sometimes misdiagnose because they cannot find exact landmark due to superimposition, moreover image can be magnified and distorted by projection technique or patient's skull position, when using these analysis and method. For overcome these defects, analysis by using of 3D CT has been introduced. In this way we can analysis precisely by getting the exact image free of artifact and finding exact landmark with no interruption of superimposition. So we want to review of relationship between various skeletal landmarks of mandible or cranial base and facial asymmetry by predictable analysis using 3D CT. We select the cases of the patients who visited our department for correction of facial asymmetry during 2003-2007 and who were taken image of 3D CT for diagnosis. 3D CT images were reconstructed to 3D image by using V-Work program (Cybermed Inc., Seoul, Korea). And we analysis the relationship between facial asymmetry and various affecting factor of skeletal pattern. The mandibular ramus hight difference between right and left was most affecting factor that express facial asymmetry. And in this research, there was no relationship between cranial base and facial asymmetry. The angulation between facial midline and mandibular ramus divergency has significant relationship with facial asymmetry