• Title/Summary/Keyword: Skin motion

Search Result 230, Processing Time 0.022 seconds

Preserved Superficial Fat Skin Composite Graft for Correction of Burn Scar Contracture of Hand (얕은 지방층을 포함한 피부복합조직이식을 이용한 손화상 반흔구축의 교정)

  • Son, Daegu;Jeong, Hoijoon;Choi, Taehyun;Kim, Junhyung;Han, Kihwan
    • Archives of Plastic Surgery
    • /
    • v.35 no.6
    • /
    • pp.716-722
    • /
    • 2008
  • Purpose: Split or full thickness skin graft is generally used to reconstruct the palmar skin and soft tissue defect after release of burn scar flexion contracture of hand. As a way to overcome and improve aesthetic and functional problems, the authors used the preserved superficial fat skin(PSFS) composite graft for correction of burn scar contracture of hand. Methods: From December of 2001 to July of 2007, thirty patients with burn scar contracture of hand were corrected. The palmar skin and soft tissue defect after release of burn scar contracture was reconstructed with the PSFS composite graft harvested from medial foot or below lateral and medial malleolus, with a preserved superficial fat layer. To promote take of the PSFS composite graft, a foam and polyurethane film dressing was used to maintain the moisture environment and Kirschner wire was inserted for immobilization. Before and after the surgery, a range of motion was measured by graduator. Using a chromameter, skin color difference between the PSFS composite graft and surrounding normal skin was measured and compared with full thickness skin graft from groin. Results: In all cases, the PSFS composite graft was well taken without necrosis, although the graft was as big as $330mm^2$(mean $150mm^2$). Contracture of hand was completely corrected without recurrence. The PSFS composite graft showed more correlations and harmonies with surrounding normal skin and less pigmentation than full thickness skin graft. Donor site scar was also obscure. Conclusion: The PSFS composite graft should be considered as a useful option for correction of burn scar flexion contracture of hand.

Face and Hand Tracking Algorithm for Sign Language Recognition (수화 인식을 위한 얼굴과 손 추적 알고리즘)

  • Park, Ho-Sik;Bae, Cheol-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.11C
    • /
    • pp.1071-1076
    • /
    • 2006
  • In this paper, we develop face and hand tracking for sign language recognition system. The system is divided into two stages; the initial and tracking stages. In initial stage, we use the skin feature to localize face and hands of signer. The ellipse model on CbCr space is constructed and used to detect skin color. After the skin regions have been segmented, face and hand blobs are defined by using size and facial feature with the assumption that the movement of face is less than that of hands in this signing scenario. In tracking stage, the motion estimation is applied only hand blobs, in which first and second derivative are used to compute the position of prediction of hands. We observed that there are errors in the value of tracking position between two consecutive frames in which velocity has changed abruptly. To improve the tracking performance, our proposed algorithm compensates the error of tracking position by using adaptive search area to re-compute the hand blobs. The experimental results indicate that our proposed method is able to decrease the prediction error up to 96.87% with negligible increase in computational complexity of up to 4%.

Transposition Lateral Arm Flap for Coverage of the Elbow Defects (전이형 외측 상완 피판술을 이용한 주관절 연부조직 결손의 피복)

  • Song, Joo-Hyoun;Lee, Yoon-Min;Lee, Joo-Yup
    • Archives of Reconstructive Microsurgery
    • /
    • v.17 no.2
    • /
    • pp.82-86
    • /
    • 2008
  • Purpose: Soft tissue defect can occur on the posterior aspect of the elbow after trauma or fracture fixation. To cover the defect and maintain elbow functions, various flap surgeries including latissimus dorsi muscle flap, lateral arm flap and radial forearm flap can be performed. We present the clinical results of transposition lateral arm flap for coverage of the elbow defect and discuss the cause of posterior soft tissue necrosis after fracture fixation. Materials and Methods: Two patients who had posterior soft tissue defect of the elbow after open reduction of the fractures around the elbow were treated with transposition lateral arm flap. The mean size of skin defect was 20 $cm^2$. The flap was elevated with posterior radial collateral artery pedicle and transposed to the defect area. Donor defect was covered with split thickness skin graft. The elbow was immobilized for 1 week in extended position and active range of motion was permitted. Results: All two cases of transposition lateral arm flap survived without marginal necrosis. The average range of motion of the elbow was 10~115 degrees. Mayo elbow performance score was 72 and Korean DASH score was 23. Conclusion: When elbow fractures are fixed with three simultaneous plates and screws, skin necrosis can occur on the posterior aspect of the elbow around olecranon area. If the size of skin defect is relatively small, transposition lateral arm flap is very useful option for orthopaedic surgeons without microsurgical technique.

  • PDF

Human-Computer Natur al User Inter face Based on Hand Motion Detection and Tracking

  • Xu, Wenkai;Lee, Eung-Joo
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.4
    • /
    • pp.501-507
    • /
    • 2012
  • Human body motion is a non-verbal part for interaction or movement that can be used to involves real world and virtual world. In this paper, we explain a study on natural user interface (NUI) in human hand motion recognition using RGB color information and depth information by Kinect camera from Microsoft Corporation. To achieve the goal, hand tracking and gesture recognition have no major dependencies of the work environment, lighting or users' skin color, libraries of particular use for natural interaction and Kinect device, which serves to provide RGB images of the environment and the depth map of the scene were used. An improved Camshift tracking algorithm is used to tracking hand motion, the experimental results show out it has better performance than Camshift algorithm, and it has higher stability and accuracy as well.

Estimation and Watermarking of Motion Parameters in Model Based Image Coding

  • Park, Min-Chul
    • Proceedings of the IEEK Conference
    • /
    • 2002.07b
    • /
    • pp.1264-1267
    • /
    • 2002
  • In order to achieve an advanced human-computer interface system, it is necessary to analyze and synthesize facial motions just as they are in an interactive way, and to protect them from unwanted use and/or illegal use for their privacy, various uses in applications and the costs of obtaining motion parameters. To estimate facial motion, a method of using skin color distribution, luminance, and geometrical information of a face is employed. Digital watermarks are embedded into facial motion parameters and then these parameters are scrambled so that it cannot be understood. Experimental results show high accuracy and efficiency of the proposed estimation method and the usefulness of the proposed watermarking method.

  • PDF

Study on Characteristics of ECG Electrodes for Motion Artifact Reduction (동잡음 저감을 위한 심전도 전극 특성에 대한 연구)

  • Kang, Young-Hwan;Park, Jae-Soon;Cho, Bum-Ki;Choi, Sang-Dong;Joung, Yeun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.6
    • /
    • pp.366-371
    • /
    • 2017
  • In this paper, we introduce an electrocardiogram (ECG) system designed to solve problems caused by wetgels and motion artifacts in measuring active movement. The system is called a dry-contact ECG and was designed by considering impedance matching between skin and electrode as well as the frictional electricity between electrode and clothes. In order to create the system, we measured impedance on the skin-electrode interface, and the result was applied to the electronic circuit scheme. Moreover, we added an electrode on the back of the measurement electrode to make a flow path to ground the electrical noise. The final ECG circuit and novel electrode were used to detect real human cardiac signals from a subject who was tested while standing still and walking. The signals obtained from the two activities were nicely shaped, without any motion artifact noise. We took electrode size into account in this study because the impedance depended on the area of the electrode. An electrode of 50 mm diameter showed the best curve for the ECG signal without any electrical noise.

A Realtime Expression Control for Realistic 3D Facial Animation (현실감 있는 3차원 얼굴 애니메이션을 위한 실시간 표정 제어)

  • Kim Jung-Gi;Min Kyong-Pil;Chun Jun-Chul;Choi Yong-Gil
    • Journal of Internet Computing and Services
    • /
    • v.7 no.2
    • /
    • pp.23-35
    • /
    • 2006
  • This work presents o novel method which extract facial region und features from motion picture automatically and controls the 3D facial expression in real time. To txtract facial region and facial feature points from each color frame of motion pictures a new nonparametric skin color model is proposed rather than using parametric skin color model. Conventionally used parametric skin color models, which presents facial distribution as gaussian-type, have lack of robustness for varying lighting conditions. Thus it needs additional work to extract exact facial region from face images. To resolve the limitation of current skin color model, we exploit the Hue-Tint chrominance components and represent the skin chrominance distribution as a linear function, which can reduce error for detecting facial region. Moreover, the minimal facial feature positions detected by the proposed skin model are adjusted by using edge information of the detected facial region along with the proportions of the face. To produce the realistic facial expression, we adopt Water's linear muscle model and apply the extended version of Water's muscles to variation of the facial features of the 3D face. The experiments show that the proposed approach efficiently detects facial feature points and naturally controls the facial expression of the 3D face model.

  • PDF

Complications of Donor Site in Latissimus Dorsi Muscle Flap (광배근 피판의 공여부에 대한 문제점의 분석)

  • Chung, Duke-Whan;Han, Chung-Soo;Cho, Chang-Hyun
    • Archives of Reconstructive Microsurgery
    • /
    • v.8 no.2
    • /
    • pp.149-153
    • /
    • 1999
  • Purpose : To investigate the complication of donor site in latissimus dorsi muscle flap. Materials and Methods : From April 1983 to March 1999, forty patients with latissimus dorsi muscle flap for reconstruction of extremity and with a follow-up period of more than 12 months were included. We analysed the complication, shoulder function, degree of shoulder muscle weakness, skin scar width after operation. Results After 1 year, skin scar widening in 12 cases(30%), limitation of shoulder motion in 9 cases(12.5%), muscle weakness in 14 cases(17.5%) were found. Conclusion. The rate of complication at donor site after latissimus dorsi flap operation is around 10%. To minimize the complication, avoiding axillary skin incision, minimal invasive harvesting by endoscopy, meticulous suturing of subcutaneous layer are needed.

  • PDF

Pacman Game Using Hand Motion Recognition (손동작 인식에 의한 Pacman 게임)

  • Shin, Seong-Yoon;Baek, Jeong-Uk;Rhee, Yang-Won
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.329-330
    • /
    • 2010
  • Classic game Pac-Man (Pacman) is playing a game using a somple hand gasture without using a keyboard or a mouse. In other words, it is a joystick game by motion to replace the arrow keys using the center coordinates of the hand. In addition, the pointer of hand is extracted by accepting images to MFC dialog using cam. Thus, movements of the monsters is to be replaced by hand movements. In this paper, smoothing, expansion, and erosion operation for the skin color extraction, and RGB images are converted to YCbCbr images.

  • PDF

Improvement of the Medical Bed for Preventing Decubitus Ulcer through Motion Analysis (운동 분석을 통한 욕창 방지용 침대 기구의 개선)

  • 심창섭;심재경;권진욱;임득재
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.713-718
    • /
    • 2003
  • Decubitus ulcer is a pressure-induced ulceration of the skin occurring in persons confined to bed for long periods of time. In order to prevent decubitus ulcer, the medical bed mechanism to minimize pressure, friction, and shear forces acting between bed and patient had been developed. Air mattress also can be effective for reducing pressure over bony prominence. In this study, motion analysis was performed to examine whether this bed mechanism functioned properly in case of using air mattress, which was much thicker than common hospital mattress. We found that the patient on the air mattress above the medical bed for preventing decubitus ulcer slipped upward and downward excessively as the general motored-bed. New bed mechanisms were synthesized kinematically using simple 4-bar and 6-bar linkages so as to reduce sliding between the bed and the patient on the air mattress for preventing decubitus ulcer.

  • PDF