• Title/Summary/Keyword: Skin heat effect

Search Result 175, Processing Time 0.029 seconds

The Experimental Estimation of the Effect on the Body Heat by the Artemisia-Lotion Pad

  • Jo, Bong-Kwan;Ko, Yeong-Guy;Jang, Sang-Yeoul;Bae, Jong-Il;Kim, Jong-Kyung;Lee, Dong-Cheol;Lee, Dong-Young;Lee, Ho-Jin;Jo, Bong-Jo;Gu, Ja-Seung;Kwon, Mi-Ja
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2206-2208
    • /
    • 2003
  • This paper is performed to find the effects on body heat by stimulating the skin with the heat of a moxibustion cauterizer and the Artemisia-lotion which cause the extension of the blood vessel. The Artemisia-lotion is made by extracting the vasodilator and antioxidant compounds from the $Artemisia-CH_2Cl_2$ fraction. The moxibustion cauterizer is constructed with a DC power supply and 3 heating electrodes with PTC(Positive Temperature Coefficients) thermistor. The stimulation temperature level of the moxibustion cauterizer is $45^{\circ}C\;-48^{\circ}C$. We gave the subjects the following stimulating conditions; only heat stimulation, only Artemisia -lotion stimulation, and both stimulations. The measurement of body heat was performed with a infrared thermography system . Finally we could estimate the effects of a betterment of circulation of the blood from $Artemisia-CH_2Cl_2$ fraction.

  • PDF

Effect on the Human Thermoregulation of Wear Training in Air Condition (여름철 냉방 조건에서의 착의 훈련이 인체의 체온 조절 반응에 미치는 효과)

  • Kim, Mi-Kyung;Choi, Jeong-Wha;Yeom, Hee-gyong
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.19 no.3
    • /
    • pp.504-515
    • /
    • 1995
  • This study was performed to investigate that wear training using thermal insulation with clothes has the effect on the human thermoregulatory response, especially on the heat tolerance. Twelve men and women in twenties wert divided into the control group, the training groups and each group except the control group had participated in wear training. The heat tolerance was assessed in all subjects who had participated in the experiment carried out in hot environment(40$\pm$1$^{\circ}C$, 50$\pm$5%RH) by such parameters as rectal temperature, skin temperature, systolic blood pressure, diastolic blond pressure, plume rate, total sweat volume, local sweat volume, subjective sensation, and the differences of heat tolerance in each group were compared. The results were as follows: In hot environment(4$0^{\circ}C$) the changing width of rectal temperature was decreased in the control and the heavy clothing group. Forehead and abdomen temperature in hot environment were significantly decreased after the training. Sweat rate was higher after the training than before. In all experimental groups, systolic and diastolic blood pries.;uses in hot environment(4$0^{\circ}C$) were significantly decreased after the training.

  • PDF

A Study on the Effect of Cold Application Using a Sponge Bath in Healthy Adults (냉요법 적용방법에 따른 냉요법 효과에 관한 연구-건강한 성인 여성에서 스폰지 목욕방법을 중심으로)

  • Chung, Hyun-Sook;Kang, Kyu-Sook;Hwang, Ae-Ran
    • The Korean Nurse
    • /
    • v.28 no.3
    • /
    • pp.68-82
    • /
    • 1989
  • This study was a quasi-experimental research study to test the characteristics of temperature regulation according to sponge bath methods of cold application. Thirteen volunteers were selected from among nursing college students according to an established criteria using a purposive sampling technique. Four different cold application methods were used: $\circled1$ tepid water sponge bath at $28^{\circ}C$, $\circled2$ 20% alcohol sponge bath at $28^{\circ}C$, $\circled3$ 40% alcohol sponge bath at $28^{\circ}C$ and $\circled4$ tepid water sponge bath at 28$^{\circ}$C plus an ice bag to the head. Changes in rectal temperature, mean skin temperature, mean body temperature, heat content change and thermal discomfort during the cold application were measured at 5 minute intervals over a 120 minute period. The data collection period was from Dec. 20, 1988 to Feb. 3, 1989. The data were analyzed using descriptive statistics, simple regression, ANOVA, Duncan's multiple range test and Pearson correlation coefficient using the SPSS-X Program. The results of the study are summarized as follows. Five general hypothesis were tested. Hypothesis 1 that "Change in heat content will be decreased for each cold application method according to the cold application time" was rejected. (tepid water sponge bath: after 10 minutes of cold application, 20% alcohol sponge bath: after 25 minutes of cold application: 40% alcohol sponge bath: after 45 minutes of cold application, tepid water sponge bath plus an ice bag to the head: after 80 minutes of cold application) Hypothesis 2 that "Thermal discomfort will be changed for each cold application method according to the cold application time" was rejected after 5minutes of cold application. Hypothesis 3 that "Change in heat content will differ among the cold application methods" was accepted except 0~5, 0~10, 0~65, 0~105 and 0~120 minute. This difference showed significance only between sponge bath methods and tepid water sponge bath plus an ice bag to the head. Hypothesis 4 that "Thermal discomfort will differ among the cold application methods" was accepted at 15, 20, 35, 45, 75, 80, 90, 95, 100, 105, 110, 115 and 120 minute of cold application time. This difference showed significance only between sponge bath methods and tepid water sponge bath plus an ice bag to the head. Hypothesis 5 that "The higher the change in heat content, the higher the thermal discomfort during the cold application time" was accepted for between 10~60 and 75 minute of cold application. In conclusion, this study showed that in sponge bath at $28^{\circ}C$, 10~80 minute was a effective cold application time in the view of heat loss through the skin. Concerning the effects of evaporation and thermal discomfort, it was found that there was no difference with regard to the solutions; tepid water sponge bath; 20% alcohol sponge bath or 40% alcohol sponge bath at a $28^{\circ}C$ controlled solution temperature. So it was thought that the type of solution itself did not have a big influence on the heat loss through skin. The combined effect of sponge bath with an ice bag to the head showed a significant difference and also showed a slight increase in thermal discomfort. On the basis of this research it can be concluded that cold application, for example, an ice bag to the head during a tepid water sponge bath is a good method as it increase heat loss through conduction, although fit can also cause a slight increase in thermal discomfort. The correlation between changes in heat content and thermal discomfort were not high. So factors other than change in heat content are considered to have an effect on the cognition of thermal discomfort.

  • PDF

Visualization of Temperature Distribution Deep Inside the Agar Gel Tissue Phantom Heated Using Moxibustion and 1064 nm Infrared Laser (쑥뜸과 1064 nm 파장의 근적외선 레이저로 가열된 아가젤 조직 팬텀 심부의 온도분포 가시화)

  • Cho, Ji-Yong;Kim, Jung-Kyung
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.4
    • /
    • pp.54-59
    • /
    • 2010
  • A laser moxibustion therapy device having effect similar to that of traditional moxibustion is being developed using 1064 nm infrared laser. The therapy device allows direct interaction of laser light with the tissue rendering temperature distribution both on the skin surface and deep under the skin. We made a device that could measure temperature of deep under the surface of agar gel tissue phantom using thermocouples. A thermal imaging camera was used to verify results from the temperature measurement device. We compared the characteristics of heat transfer inside the tissue phantom during moxibustion and laser irradiation. The temperature distribution measured by thermocouples was found to be similar to that of distribution given by thermal imaging camera.

The Effect of Strength by Changing Tool Shape in the Friction Stir Welding (마찰교반용접에서 툴의 형상이 접합부 강도에 미치는 영향에 관한 연구)

  • Chun, Chang-Keun;Kim, Hyeong-Ju;Park, In-Gyu;Umm, Kyung-Su;Chang, Woong-Seong
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1613-1617
    • /
    • 2009
  • As demand regarding a recent energy-saving rises, the using ratio of the aluminum plate in manufacturing of a railroad vehicle has been increasing. The aluminum structure to be applied to a railroad vehicle is divided to single skin and double skin, and the main aluminum product is mainly Al 6005 extrude and Al 5083 rolled in domestic market. The Al 6005 alloy is applied heat treatment in order to improve the strength of material. Therefore there is the disadvantage that the strength of welding zone decreases compare with base material's if you apply to fusion welding like MIG(metal inert gas) welding. In this paper we tried to apply friction stir welding to solve these problems. In this study we investigated how tensile strength and fatigue strength were changed in case of changing the shoulder diameter of thread tool.

  • PDF

A study on the PAL according to thermal characteristic of building skin and perimeter zone depth (건물 외피의 열특성과 외주부 깊이에 따른 PAL에 관한 연구)

  • Kim, Ji-Hye;Kim, Hwan-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.2
    • /
    • pp.33-38
    • /
    • 2010
  • The perimeter zone is space which receives a significant effect of ambient condition, it is necessary to improve the thermal performance in order to building energy saving. For this reason, a lot of study about the active approach is being performed, such as perimeter-less air conditioning system. But the performance of the perimeter zone is necessary to improve, through the passive approach. Therefore, the purpose of this study is to provide basic materials of energy-saving design of perimeter zone, based of the PAL that simulation changing the thickness of insulation and the rate of windows.

Effect of Skin Lipid Barrier Formation on Hataedock Treatment with Douchi

  • Kim, Hee-Yeon;Ahn, Sang-hyun;Yang, Injun;Kim, Kibong
    • The Journal of Korean Medicine
    • /
    • v.38 no.2
    • /
    • pp.41-52
    • /
    • 2017
  • Objectives: Hataedock is indigenous treatment of Korean medicine that administers herbal extracts orally to newborn infants for remove the fetal heat. The purpose of this study was to evaluate skin lipid barrier formation effect of Hataedock treatment with Douchi. Methods: We measured the Western blot to observe the expression of protein such as involucrin and loricrin. Moreover, we observed immunohistochemical changes in NC/Nga mice. The 3-week-old NC/Nga mice were divided into 3 groups: the 3-week-old control group (3w-Ctrl), 5-week-old control group (5w-Ctrl), and the Hataedock-treated group (5w-FGT). Only the 5w-FGT group was treated with Douchi at the 3rd week. We identified the changes of the lipid skin barrier and protein differentiation through immunohistochemical changes of involucrin, loricrin, filaggrin and acid sphingomyelinase (ASM) in the stratum corneum. Results: The expression of involucrin and loricrin was increased in the Western blot that was treated with concentration of Douchi extracts. In 5w-FGT group, loricrin-positive reaction was increased by 54.0%, involucrin-positive reaction was increased by 84.0%, filaggrin-positive reaction was increased by 108.0% and ASM-positive reaction was increased by 91.0% in the stratum corneum. Conclusions: These results suggest that Hataedock treatment with Douchi promoted skin lipid barrier formation by promoting differentiation of keratinocytes.

Developing a Multi-Functional Smart Down Jacket Utilizing Solar Light and Evaluating the Thermal Properties of the Prototype (태양광을 활용한 스마트 다운재킷 개발 및 보온성능 평가)

  • Yi, Kyonghwa;Kim, Keumwha
    • Journal of Fashion Business
    • /
    • v.19 no.4
    • /
    • pp.92-108
    • /
    • 2015
  • This study aimed at developing a down jacket prototype that utilized sunlight as an alternative energy source with no air pollution. The jacket is filled with flexible solar panels and has a heat-generating function and LED function. In this study, three smart down jacket prototypes were developed, and the jacket's capabilities were demonstrated through the thermal effect on the performance test. The typical output voltage of the flexible solar panels was 6.4V. By connecting the 2 solar cell modules in series, the final output voltage was 12.8V. A battery charge regulator module was used the KA 7809 (TO-220) of 9V. Three heating pads were to be inserted into the belly of the jacket as direct thermal heating elements, and the LED module was configured, separated by a flash and an indicator. The smart down jacket was designed to prevent damage to the down pack without the individual devices' interfering with the human body's motion. Because this study provides insulation from extreme cold with a purpose, the jacket was tested for heat insulation properties of non-heating, heating on the back, heating on the abdomen, and heating on both the back and abdomen in a sitting posture in a static state. Thermal property analysis results from examining the average skin temperature, core temperature, and the temperature and humidity within clothing showed, that placing a heating element in one place was more effective than distributing the heating elements in different locations. Heating on the back was the most effective for maintaining optimal skin temperature, core temperature, and humidity, whereas heating on the abdomen was not effective for maintaining optimal skin temperature, core temperature, or humidity within clothing because of the gap between the jacket and the body.

Effect of Lithospermi Radix on Contact Dermatitis Induced by Dinitrofluorobenzene in Mice

  • Kim, Han-Na;Kim, Mi-Young;Choi, Chan-Hun;Kim, Byung-Joo;Kim, Kyung-Yoon;Kim, Gye-Yeop;Jeong, Hyun-Woo;Kim, Hyung-Woo
    • Journal of Pharmacopuncture
    • /
    • v.15 no.2
    • /
    • pp.7-10
    • /
    • 2012
  • Objectives: The root of Lithospermum erythrorhizon Sieb. et Zucc. (Lithospermi Radix, LR) is a kind of heat clearing and blood cooling medicinal herbs. It can clear away heat and cool the blood, reduce toxins and disperse maculae. LR has long been used as efficacious therapy for inflammation, burns, frostbite and skin diseases such as eczema and psoriasis. Methods: In the present study, we investigate anti-allergic and anti-inflammatory effects of LR by using the 1-fluoro-2, 4- dinitrofluorobenzene (DNFB)-induced contact dermatitis mouse model. Results: Topical application of 10 mg/mL of LR effectively inhibited skin lesions induced by repeated paintings with DNFB. Topical application of LR also inhibited hyperplasia, edema, spongiosis and infiltrations of mononuclear cells. In addition, production levels of total immunoglobulin and IgG1 in serum were decreased by using LR in vivo. Conclusions: These data suggest that LR acts as an antiinflammatory agent, improving skin lesions in CD mice.

SORET AND ELECTROMAGNETIC RADIATION EFFECT OF MHD MICRO POLAR FLUID PAST A POROUS MEDIUM IN THE PRESENCE OF CHEMICAL REACTION

  • SHEEBA JULIET S.;VIDHYA, M.
    • Journal of applied mathematics & informatics
    • /
    • v.41 no.5
    • /
    • pp.1085-1102
    • /
    • 2023
  • In this study the magneto hydrodynamic (MHD) micro polar fluid flow of a viscous incompressible fluid past a porous medium in the presence of chemical reaction is considered. This work is devoted to investigate the Soret effect and Electromagnetic radiation effect and analyze analytically. In the energy equation the applied magnetic field strength and in the concentration equation the Soret effect are incorporated. The basic PDE (partial differential equations) are reduced to ODE (ordinary differential equations) using non dimensional variables. Then the analytical solution of the dimensionless equations are found using perturbation technique. The features of the fluid flow parameters are analyzed, discussed and explained graphically. The graphical solutions are found using MATLAB R2019b. Skin friction coefficient at the wall, Couple stress coefficient at the plate and the local surface heat flux are also thoroughly examined. Overall, this study sheds light on the complex interplay between physical parameters in the behavior of MHD micro-polar fluid past a porous medium in the presence of chemical reaction.