• Title/Summary/Keyword: Skin depth

Search Result 374, Processing Time 0.026 seconds

Dose Characteristics of Total-Skin Electron-Beam Irradiation with Six-Dual Electron Fields (Six-Dual 전자선 조사면에 의한 전신 피부 조사의 선량 특성)

  • Choi, Tae-Jin;Kim, Jin-Hee;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.16 no.3
    • /
    • pp.337-345
    • /
    • 1998
  • Purpose : To obtain the uniform dose at limited depth to entire surface of the body, the dose characteristics of degraded electron beam of the large target-skin distance and the dose distribution of the six-dual electron fields were investigated Materials and Method : The experimental dose distributions included the depth dose curve, spatial dose and attenuated electron beam were determined with 300 cm of target-skin distance (TSD) and full collimator size (35*35 $cm^2$ on TSD 100 cm) in 4 MeV electron beam energy. Actual collimated field size of 105 cm * 105 cm at the distance of 300 cm could include entire hemibody. A patient was standing on step board with hands up and holding the pole to stabilize his/her positions for the six-dual fields technique. As a scatter-degrader, 0.5 cm of acrylic plate was inserted at 20 cm from the body surface on the electron beam path to induce ray scattering and to increase the skin dose. Results : The full width at half maximum(FWHM) of dose profile was 130 cm in large field of 105*105 $cm^2$ The width of $100\pm10\%$ of the resultant dose from two adjacent fields which were separated at 25 cm from field edge for obtaining the dose unifomity was extended to 186 cm. The depth of maximum dose lies at 5 mm and the 80$\%$ depth dose lies between 7 and 8 mm for the degraded electron beam by using the 0.5 cm thickness of acrylic absorber. Total skin electron beam irradiation (TSEBI) was carried out using the six dual fields has been developed at Stanford University. The dose distribution in TSEBI showed relatively uniform around the flat region of skin except the protruding and deeply curvatured portion of the body, which showed excess of dose at the former and less dose at the latter. Conclusion : The percent depth dose, profile curves and superimposed dose distribution were investigated using the degraded electron beam through the beam absorber. The dose distribution obtained by experiments of TSEBI showed within$\pm10\%$ difference except the protruding area of skin which needs a shield and deeply curvatured region of skin which needs boosting dose.

  • PDF

Evaluation of Vertical Bearing Capacity for Bucket and Shallow Foundations Installed in Sand (사질토 지반에 설치된 버킷기초 및 얕은기초의 수직지지력 산정)

  • Park, Jeongseon;Park, Duhee;Jee, Sunghyun;Kim, Dongjoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.9
    • /
    • pp.33-41
    • /
    • 2015
  • The vertical bearing capacity of a bucket foundation installed in sand can be calculated as sum of the skin friction and end bearing capacity. However, the current design equations are not considering the non-associated flow characteristics of sand and the reduction in the skin friction and increase in the end bearing capacity when the vertical load is applied. In this study, we perform two-dimensional axisymmetric finite element analyses following non-associated flow rule and calculate the vertical bearing capacity of circular bucket foundation of various sizes installed in sand of different friction angles. After calculating the skin friction and end bearing force at the ultimate state, design equations are derived for each. The skin friction of bucket foundation is shown significantly small compared to the end bearing capacity. Considering the difference with the available design equation for piles, it is recommended that the equation for piles is used for the bucket foundation. A new shape-depth factor ($s_q{\cdot}d_q$) for bucket foundation is recommended which also accounts for the increment of the end bearing capacity due to skin friction. Additionally, the shape and depth factor of embedded foundation proposed from the associated flow rule can overestimate the bearing capacity in sand, so it is more adequate to use the shape-depth factor proposed in this study.

New Evaluation System of Cosmetic Effects on Morphology of Skin Surface Using TSRLM with Image Analyser

  • Kim, Jong-Il;Lee, Joa-Hoon;Lee, Yoo-Young;Kim, Chang-Kew
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.16 no.1
    • /
    • pp.47-63
    • /
    • 1990
  • Image analyser was used to understand the condition of skin surface and to evaluate the efficacy of cosmetic treatment. It was unsatisfactory to analyse skin surface structure although several methods using image analyser had been presented. We developed the new system composed of image analyser and Tandem Scanning Reflected Light Microscope (TSRLM) having the remarkable optical sectioning property as image input device. By using this new system, we quantitatively measured the change of skin surface, the depth and width of furrow in micron unit, resulted by cosmetic treatments. And also three dimensional image of skin was reconstructed with serial sectioned images, which were captured through TSRLM, for better understanding of the effect of cosmetic treatment. It was found that skin relief was more easily understood and the change of skin surface caused by cosmetic treatment was more accurately measured by using this system. In addition, we was also aware of the possibility of in vivo direct measurement of skin furrow without replica. It was conceivable that our system could be applicable for study of cosmetic effects further.

  • PDF

Recent Research Trends of Acupuncture for Wrinkle Treatment (주름 개선을 위한 침 연구의 현황분석)

  • Jung, Hyeon-Suk;Kim, Tae-Jun;Park, Ji-Yeun
    • Korean Journal of Acupuncture
    • /
    • v.38 no.2
    • /
    • pp.62-74
    • /
    • 2021
  • Objectives : The aim of this study is to analyze the effect of acupuncture and the details of acupuncture treatment methods on skin wrinkles. Methods : Search was conducted in Pubmed, KISS, and NDSL databases for acupuncture studies on skin wrinkles. The detailed therapeutic techniques of acupuncture used for skin wrinkles and the effect of acupuncture on skin wrinkle improvement were analyzed. Then, the study results using the same indicator were compared through meta-analysis in order to compare the effects of acupuncture with the control group. The quality of randomized controlled trials (RCTs) was assessed using the risk of bias (ROB) assessment tool (Ver. 1.0, Cochrane Collaboration). Results : A total of 10 RCTs and 19 case series were included in this study. The most frequently used therapeutic technique for skin wrinkle improvement was Microneedle therapy system (MTS, n=19), and they were mostly used with aesthetic solutions (13 out of 19 studies). Skin wrinkle related indexes were most commonly used to evaluate skin wrinkle improvement (n=14). Panax Ginseng pharmacopuncture showed the most remarkable effect in improving the range of skin wrinkles and the depth of skin wrinkles. MTS+epidermal growth factor improved the levels of skin hydration, skin elasticity, and variation of skin pigment the most. MTS+Endothelial precursor cell improved the number of skin melanin the most. Three RCTs included in the meta-analysis showed moderate ROB on average. Conclusions : Acupuncture treatment was effective in improving skin wrinkles. However, a precise study design using unified indicators and appropriate controls needs to be performed in further studies in order to establish more convincing evidence of the effectiveness of acupuncture for improving skin wrinkles.

The Variation of Surface Dose by Beam Spoiler in 10 MV Photon Beam from Linear Accelerator (선형가속기 10 MV 광자선에서 산란판(Beam Spoiler) 사용 시 표면선량 변화)

  • Bae, Seong-Cheol;Kim, Jun-Ho;Lee, Choul-Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.21-28
    • /
    • 2006
  • Purpose: The purpose of this study is to find a optimal beam spoiler condition on the dose distribution near the surface, when treating a squamous cell carcinoma of the head and neck and a lymphatic region with 10 MV photon beam. The use of a optimal spoiler allows elivering high dose to a superficial tumor volume, while maintaining the skin-sparing effect in the area between the surface to the depth of 0.4 cm. Materials and Methods: The lucite beam spoiler, which were a tissue equivalent, were made and placed between the surface and the photon collimators of linear accelerator. The surface-dose, the dose at the depth of 0.4 cm, and the maximum dose at the dmax were measured with a parallel-plate ionization chamber for $5{\times}5cm\;to\;30{\times}30cm^2$ field sizes using lucite spoilers with different thicknesses at varying skin-to-spoiler separation (SSS). In the same condition, the dose was measured with bolus and compared with beam spoiler. Results: The spoiler increased the surface and build-up dose and shifted the depth of maximum dose toward the surface. With a 10 MV x-ray beam and a optimal beam spoiler when treating a patient, a similer build-up dose with a 6 MV photon beam could be achieved, while maintaining a certain amount of skin spring. But it was provided higher surface dose under SSS of less than 5 cm, the spoiler thickness of more than 1.8 cm or more, and larger field size than $20{\times}20cm^2$ provided higher surface dose like bolus and obliterated the spin-sparing effect. the effects of the beam spoiler on beam profile was reduced with increasing depths. Conclusion: The lucite spoiler allowed using of a 10 MV photon beam for the radiation treatment of head and neck caner by yielding secondary scattered electron on the surface. The dose at superficial depth was increased and the depth of maximum dose was moved to near the skin surface. Spoiling the 10 MV x-ray beam resulted in treatment plans that maintained dose homogeneity without the consequence of increased skin reaction or treat volume underdose for regions near the skin surface. In this, the optimal spoiler thickeness of 1.2 cm and 1.8 cm were found at SSS of 7 cm for $10{\times}10cm^2$ field. The surface doses were measured 60% and 64% respectively. In addition, It showed so optimal that 94% and 94% at the depth of 0.4 cm and dmax respectively.

  • PDF

Clinical Study of Cream Containing Pueraria mirifia for Skin Elasticity (Pueraria mirifica 추출물 함유 화장품의 피부 탄력 임상 효능 평가)

  • Kim Bora;Jung Sung Won;Lee Joo Dong;Ryoo Hee Chang;Cherdshewasart Wichai
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.30 no.3 s.47
    • /
    • pp.385-388
    • /
    • 2004
  • Recently, along with the remarkable increase in interest in natural products, the application of phytoestrogens in anti-aging products has become very important. In the focus, we developed Pueraria mirifica (PM), in this in vivo study on skin elasticity and wrinkles, and investigated the anti-aging properties. Thirty healthy women volunteers, between the ages of 30 and 60, applied the cream formula with $4\% Pueraria mirifica or placebo, on the face area twice a day for 16 weeks. The evaluation was made by silicon replica analysis, Cutometer SEM 575 and Comeometer followed by statistical treatment using the student's t-test. Results of skin elasticity measurement showed that topical application on the skin increased the total surface of skin elasticity in comparison with placebo group (p<0.05). However, PM cream does not have prominent effect on the depth of wrinkles and skin moisturization. This in vivo study demonstrates that, PM exhibits a significant effect on skin elasticity therefore, is of great interest in anti-aging and firmness skin care products.

Analysis of Skin Micro-relief on Healthy Korean Youth According to Sex (건강한 한국인 청년에서 성별에 따른 피부표면 미세지형 분석)

  • Kim, Hyun-Wook;Oh, Seung-Hak;Kim, Nam-Sook;Na, Ji-Eun;Lee, Sang-Hoon;Park, In-Sung;Kwon, Soon-Wook;Rhyu, Im-Joo
    • Applied Microscopy
    • /
    • v.42 no.1
    • /
    • pp.35-42
    • /
    • 2012
  • The skin is the largest organ of the integument system whose surface is closely related to many physiological and pathological conditions. The skin surface is closely related to functional status of the epidermis and dermis. The outermost surface of the skin shows characteristic pattern defined by small furrows are called micro-relief. The micro-relief change is according to physiological and pathological conditions of the skin. But, there is no data on health Korean skin micro-relief yet. This study presents some aspect of health Korean skin micro-relief from the twenties. The silicon replicas obtained from forearm, dorsum hand and finger were analyzed by profiles were accessed by stereoscopy. We measured density of furrow, width of furrow, and depth of furrow in micro-relief with sectioned silicon replica sample using stereoscope. Stereoscopic analysis showed that male group has a larger density of furrow and depth furrow in finger significantly. The densities of furrow were shown different not only between forearm and finger but also between finger and hand in male with female group. In conclusion, there were differences results between sex different and regional difference in skin replica profile. These quantitative data can be used for basis of further skin research for Korean.

The Depth and Angle during Caudal Epidural Approach in Adult (성인에서 미추부 경막외강의 깊이와 각도)

  • Jo, Dae-Hyun;Kim, Myoung-Hee;Choy, Yoon-Keun
    • The Korean Journal of Pain
    • /
    • v.14 no.2
    • /
    • pp.207-210
    • /
    • 2001
  • Backgroud: Caudal blocks have been used for pain management in outpatient clinics. It is important to estimate the proper depth and angle in order to increase the success rate of the procedure. Methods: Data was collected from 60 patients who visited our pain clinic. We measured the depth of the needle's penetration and the angle of the needle at the insertion point when a caudal approach was confirmed by air flow method. We recorded age, sex, body weight and height, and calculated the ponderal index. Results: The depth from the skin to the caudal epidural space was a mean 2-4 cm ($3{\pm}0.4\;cm$). The angle at the needle insertion point was a mean 15-50 degree ($34.9{\pm}6.8$ degree). Conclusions: If we use the mean depth and angle as a guide, complications during the caudal epidural procedure can be avoided.

  • PDF

Safe Needling Depth of Pungbu(GV16) with MRI-a Retrospective Study (MRI를 통한 풍부혈(GV16)의 안전 자침 깊이에 대한 연구)

  • Yang, Hyun Jung;Park, Hae In;Lee, Kwang Ho
    • Journal of Acupuncture Research
    • /
    • v.32 no.4
    • /
    • pp.11-16
    • /
    • 2015
  • Objectives : The purpose of this study is to determine the safe needling depth of Pungbu($GV_{16}$) retrospectively by using magnetic resonance imaging (MRI). Methods : We chose 114 Brain or C-spine MRI images from the Sang-Ji hospital picture archiving communication system. We measured the shortest distance from skin to cerebral dura mater passing by posterior edge of the foramen magnum on the sagittal view for the depth of Pungbu. We analyzed the differences between male and female measured values by using a student t-test. Results : The average depth of male insertion was $49.71{\pm}6.32mm$ and the shortest depth of insertion was 36.29 mm. The average depth of female insertion was $39.84{\pm}5.25mm$ and the shortest depth of insertion was 30.02 mm. The results showed a significant difference according to gender (p=0.00). Conclusions : The depth of male insertion is deeper than that of female, and the safe needling depth in the case of males is 36.29-67.35 mm, while the safe needling depth in the of females is 30.02-52.18 mm.

A Real-time Face Tracking Algorithm using Improved CamShift with Depth Information

  • Lee, Jun-Hwan;Jung, Hyun-jo;Yoo, Jisang
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.2067-2078
    • /
    • 2017
  • In this paper, a new face tracking algorithm is proposed. The CamShift (Continuously adaptive mean SHIFT) algorithm shows unstable tracking when there exist objects with similar color to that of face in the background. This drawback of the CamShift is resolved by the proposed algorithm using Kinect's pixel-by-pixel depth information and the skin detection method to extract candidate skin regions in HSV color space. Additionally, even when the target face is disappeared, or occluded, the proposed algorithm makes it robust to this occlusion by the feature point matching. Through experimental results, it is shown that the proposed algorithm is superior in tracking performance to that of existing TLD (Tracking-Learning-Detection) algorithm, and offers faster processing speed. Also, it overcomes all the existing shortfalls of CamShift with almost comparable processing time.