• Title/Summary/Keyword: Skin condition

Search Result 941, Processing Time 0.034 seconds

Sick Building Syndrome in 130 Underground Workers (지하상가 근무자의 건강 장애에 관한 실태조사)

  • Joo, Ree;SaKong, Joon;Chung, Jong-Hak;Park, Sang-Whan;Kim, Dong-Hee;Kim, Dong-Min;Choi, Eun-Kyong;Cho, Hyun-Geon
    • Journal of Yeungnam Medical Science
    • /
    • v.15 no.2
    • /
    • pp.325-340
    • /
    • 1998
  • A cross-sectional study was conducted to evaluate the relationship between sick building syndrome(SBS) and the environmental factors affecting SBS on 130 underground workers and 60 controls. The study consisted of 1) a review of environmental condition 2) measurement of temperature, $O_2$, $CO_2$, CO, and formaldehyde and 3) a questionnaire survey of symptom prevalence and perception of environmental conditions using indoor Air Quality questionnaire recommended by National Institute for Occupational Safety and Health. Bronchitis and dust allergy were more prevalent in underground workers significantly(p < 0.05). Among the 18 symptoms related to the indoor air pollution, the experience rate of dry, itching or irritated eyes, sore or dry throat, chest tightness, tired or strained eyes and dry or itchy skin symptom was significantly different between the underground workers and controls. The diagnostic criteria of SBS was defined as at least 1 symptom is experienced 1-3 times a week during the last 1 month among 18 indoor air pollution related symptoms which can be relieved by moving out of the underground. Applying the criteria, the mean symptom score was significant higher in underground workers than controls significantly (p < 0.05). These resalts indicated that underground workers are under inappropriate ergonomic and physical condition and inadequate ventilation. Their experience rate of symptoms related to indoor air pollution and prevalence of SBS was significantly higher than controls. To reduce the prevalence of SBS of underground workers, the surveillance system of indoor air quality, restriction of using fuel in underground and legislative regulations for the environment are needed to establish a better indoor air quality. Early detection, treatment and prevention of SBS through medical attention is also needed.

  • PDF

Operative treatment for Proximal Humeral Fracture (상완골 근위부 골절의 수술적 요법)

  • Park Jin-Young;Park Hee-Gon
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.2
    • /
    • pp.168-175
    • /
    • 2003
  • Fracture about proximal humerus may be classified as the articular segment or the anatomical neck, the greater tuberosity, the lesser tuberosity, and the shaft or surgical neck. Now, usually used, Neer's classification is based on the number of segments displaced, over 1cm of displaced or more than 45 degrees of angulation , rather than the number of fracture line . Absolute indication of a operative treatment a open fracture, the fracture with vascular injury or nerve injury , and unreductable fracture-dislocation . Inversely, the case that are severe osteoporosis, and eldly patient who can't be operated by strong internal fixation is better than arthroplasty used by primary prosthetic replacement and early rehabilitation program than open reduction and internal fixation. The operator make a decision for the patient who should be taken the open reduction and internal fixation, because it's different that anatomical morphology, bone density, condition of patient. The operator decide operation procedure. For example, percutaneous pinning, open reduction, plate & screws, wire tension bands combined with some intramedullary device are operation procedure that operator can decide . The poor health condition for other health problem, fracture with unstable vital sign and severe osteoporosis , are the relative contraindication. The stable fracture without dislocation is not the operative indication . The radiologic film of the prokimal humerus before the operation can not predict for fracture evaluation. It's necessary to good radiologic film for evaluation of fracture form. The trauma serise is better than the other radiologic film for evaluation. The accessary radiologic exam is able to help for evaluation of bone fragment and anatomy. The CT can be helpful in evaluating these injury, especially if the extract fracture type cannot be determined from plain roenterogram of the proximal humerus, bone of humerus head. If the dislocation is severe anatomically , we could consider to do three dimentional remodelling. The MRI doing for observing of bony morphology before the operation is not better than CT If we were suspicious of vascular injury, we could consider the angiography.

  • PDF

A SURVEY OF SEDATION PRACTICES IN THE KOREAN PEDIATRIC DENTAL OFFICE (어린이의 치과치료시 약물에 의한 진정요법 사용에 대한 실태조사)

  • An, So-Youn;Choi, Byung-Jai;Kwak, Ji-Youn;Kang, Jeong-Wan;Lee, Jae-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.3
    • /
    • pp.444-453
    • /
    • 2005
  • Sometimes the dentists encounter a child who can not be treated with traditional behavior management techniques (for example, reward, restraint, Tell-Show-Do, familialization). In such a case, the dentists use sedation technique. Recently, in Korea, the use of sedation by pediatric dentists is increased. But, the guideline and survey of sedation is very insufficient. Now, we need a survey of sedation practice in Korea. We carried out research on the actual condition about sedation with a questionaire to pediatric dentists in Korea. Followings are the conclusions 1. Sixty six percent of pediatric dentists use sedative agents in their practice. In this study, using sedation shows an increase as compared with the past. 2. Determinative factors of using sedation were orderly behavior management, number of visiting, guidian's opinion, amount of treatment, general condition. 3. Distribution of ages in patients sedated with agents was orderly 3 years, 4-5 years, under 2 years, 6-10 years, more than 10 years. 4. Particular sedative drugs were chloral hydrate 60-70mg/kg, hydroxyzine 10-40mg/kg(25mg/kg), and oral route was the most favorable route. 5. Observation of skin and nail color, pulse oximeter were the most frequently utillized monitoring method during sedation. 6. Only fifty six percent of pediatric dentists complete the cardiopulmonary resuscitation course.

  • PDF

Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

  • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.160-167
    • /
    • 2015
  • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.

Comparison and evaluation between 3D-bolus and step-bolus, the assistive radiotherapy devices for the patients who had undergone modified radical mastectomy surgery (변형 근치적 유방절제술 시행 환자의 방사선 치료 시 3D-bolus와 step-bolus의 비교 평가)

  • Jang, Wonseok;Park, Kwangwoo;Shin, Dongbong;Kim, Jongdae;Kim, Seijoon;Ha, Jinsook;Jeon, Mijin;Cho, Yoonjin;Jung, Inho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.7-16
    • /
    • 2016
  • Purpose : This study aimed to compare and evaluate between the efficiency of two respective devices, 3D-bolus and step-bolus when the devices were used for the treatment of patients whose chest walls were required to undergo the electron beam therapy after the surgical procedure of modified radical mastectomy, MRM. Materials and Methods : The treatment plan of reverse hockey stick method, using the photon beam and electron beam, had been set for six breast cancer patients and these 6 breast cancer patients were selected to be the subjects for this study. The prescribed dose of electron beam for anterior chest wall was set to be 180 cGy per treatment and both the 3D-bolus, produced using 3D printer(CubeX, 3D systems, USA) and the self-made conventional step-bolus were used respectively. The surface dose under 3D-bolus and step-bolus was measured at 5 measurement spots of iso-center, lateral, medial, superior and inferior point, using GAFCHROMIC EBT3 film (International specialty products, USA) and the measured value of dose at 5 spots was compared and analyzed. Also the respective treatment plan was devised, considering the adoption of 3D-bolus and stepbolus and the separate treatment results were compared to each other. Results : The average surface dose was 179.17 cGy when the device of 3D-bolus was adopted and 172.02 cGy when step-bolus was adopted. The average error rate against the prescribed dose of 180 cGy was -(minus) 0.47% when the device of 3D-bolus was adopted and it was -(minus) 4.43% when step-bolus was adopted. It was turned out that the maximum error rate at the point of iso-center was 2.69%, in case of 3D-bolus adoption and it was 5,54% in case of step-bolus adoption. The maximum discrepancy in terms of treatment accuracy was revealed to be about 6% when step-bolus was adopted and to be about 3% when 3D-bolus was adopted. The difference in average target dose on chest wall between 3D-bolus treatment plan and step-bolus treatment plan was shown to be insignificant as the difference was only 0.3%. However, to mention the average prescribed dose for the part of lung and heart, that of 3D-bolus was decreased by 11% for lung and by 8% for heart, compared to that of step-bolus. Conclusion : It was confirmed through this research that the dose uniformity could be improved better through the device of 3D-bolus than through the device of step-bolus, as the device of 3D-bolus, produced in consideration of the contact condition of skin surface of chest wall, could be attached to patients' skin more nicely and the thickness of chest wall can be guaranteed more accurately by the device of 3D-bolus. It is considered that 3D-bolus device can be highly appreciated clinically because 3D-bolus reduces the dose on the adjacent organs and make the normal tissues protected, while that gives no reduction of dose on chest wall.

  • PDF

Evaluation of compensator to reduce thermal sensation in oncological hyperthermia (고주파 온열암 치료 시 열감감소를 위해 자체 제작한 보상체의 유효성 평가)

  • Lee, Yeong Cheol;Kim, Sun Myung;Jeong, Deok Yang;Kim, Young Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.27-32
    • /
    • 2017
  • Objectives: Oncological hyperthermia is a treatment to selectively kill cancer cells by directly applying heat to cancer cells or indirectly demage cancer cells. One of the most side effects of treatment is burn that can appear on the skin. In areas with irregularities such as the umbilicus, the patient feels a sense of hot and treatment may be discontinued. Therefore, in order to eliminate the irregularities of these areas, compensators are manufactured and measured to decrease in temperature. Materials and Methods: The temperature of the four sites (umbilicus, near the umbilicus, 5 cm below the umbilicus, back) was measured five times around the umbilicus in patients who were treated at oncological hyperthermia treatment device(EHY-2000, Oncotherm Kft, Hungary). The temperature sensor (TM-100, Oncotherm Kft, Hungary) was attached to four sites and the changes were observed at 5, 15, 25, 35, and 50 minutes after treatment. Compensators of three materials were used(Vaseline, Bolus, Dental resin). The data measured five times were compared for each compensator. Results: The temperature change when the compensator was not used increase from 34.65 degrees to 42.9 degrees on average. The near umbilicus was changed from 32.20 degrees to 37.00 degrees, and the 5 cm below the umbilicus was changed from 31.90 to 34.41 degrees. When the compensator material was inserted into the umbilicus, the temperature change was measured as 5.42 degrees for bolus, 6.55 degrees for vaseline, and 6.83 degrees for resin. Conclusion: Using the compensator in the region where the irregularities such as the umbilicus, the heat sensation could be reduced. the use of a resin that can be customized not only lowers the temperature but also significantly reduces the feeling of the patient. It will be possible to reduce the heat sensation in the treatment and to treat it in a more comfortable condition.

  • PDF

The effect of Percutaneous pig-tail catheter drainage in the management of lung abscess and empyema (폐 농양및 농흉 치료에서 Pig-tail 도관 배액술의 효과)

  • Kim, Yeon Sao;Kim, Seong Min;Kim, Jin Ho;Lee, Kyung Sang;Yang, Suck Chul;Yoon, Ho Joo;Shin, Dong Ho;Park, Sung Soo;Lee, Jung Hee;Choi, Yo Won;Jean, Seok Chol;Kim, Young Tae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.4
    • /
    • pp.571-578
    • /
    • 1996
  • Background : Long abscess is an accumulation of pus within a destroyed portion of the lung. Antibiotic therapy and postural drainge has proven to be an effective method of treatment for the majority of patients with pyogenic lung abscess. When medical therapy fails, thoracotomy and pulmonary resection are the current therapies. empyema is pus in the pleural space, and this term is deserved for effusions on which the Gram stain of the pleural fluid is positive. Initially, such collection may be drained via chest tribe. Recently, in patients who are judged to be unsuitable for surgery are in poor condition, percutaneous drainage using pig-tail catheter has been performed. We report out experience with 10 cases of lung abscess and 23 cases of empyema who were treated by percutaneous pit-tail catheter drainage. Subjects and Methods : Our study included 10 patients with lung abscess and 23 patients with empyema who were treated by percutaneous pig-tail catheter drainage, from January, 1990, to May, 1996, at Hanyang University then a pig-tail catheter was inserted into the abscess or the site of empyema under fluoroscopic and ultrasonograpic guidance. Following aspiration, the catheter was sutured into the skin, and connected to the suction tip. Catheter drainage was discontinued when the abscess of empyema was resolved in radiologically and clinically. Results : There were 2 cases of lung abscess caused by Staphylococcus aureus and Klebsiella pneumoniae and 14 cases of empyema caused by M. tuberculosis. The others were unknown. The duration of drainage was 1-2 weeks in 7 cases of lung abscess and 14 cases of empyema. In the 29 of 33 patients, percutaneous drainage were carried out successfully 20 of the 29 Gases rapidly improved. Conclusion : Percutaneous drainge is effective and relatively saute for management of lung abscess or empyema refractory to medical therapy or poor candidates for surgical treatment.

  • PDF

Effect of RED and FAR-RED LEDs on the Fruit Quality of 'Hongro'/M.26 Apple (적색과 초적색 LEDs 보광이 '홍로'/M.26 사과의 과실품질에 미치는 영향)

  • Kang, Seok-Beom;Song, Yang-Yik;Park, Moo-Yong;Kweon, Hun-Joong
    • Korean Journal of Environmental Agriculture
    • /
    • v.32 no.1
    • /
    • pp.42-47
    • /
    • 2013
  • BACKGROUND: As improved LEDs (Light Emitting Diode) industry and decreased the price of LEDs in Korea, some farmers try to using the RED LEDs in green house and open field to increase the production of crop under bad weather condition. The aim of this study is to find out the effect of RED and FAR-RED LEDs lighting on the fruit quality of twelve-year old 'Hongro'/M.26 apple during night after sunset. METHODS AND RESULTS: FAR-RED (730nm, 2 and 4 hour) and RED (620nm, 2 and 4 hour) with 20 LED/PCB were treated in orchard for 16 weeks from June 10 to October 10 in 2009 and 2010 with control as an comparison. In our experiments, leaf weight was significantly higher in RED LEDs than control, tended to be decreased as times of FAR-RED lighting increased. Fruit weight was increased more in RED LEDs than control in 2009 and 2010, but decreased in FAR-RED lighting compared to control in 2010. Firmness and Hunter's a value of fruit were increased in FAR-RED lighting with 2 and 4 h than control. Soluble solid contents were higher in 2 h RED and 2, 4 h FAR-RED LEDs compared to control in 2009, there was no significant difference in 2010. Acid contents were no difference among the treatments. CONCLUSION(S): In our results, we found that RED LEDs was more helpful to increase the fruit weight and FAR-RED LEDs promote to be higher hunter a value of fruit skin. So, we thought that it is necessary to more study if mixed of RED and FAR-RED lighting is more helpful to promote fruit quality of 'Hongro' apple than single lighting of RED or FAR-RED LEDs respectively.

Evaluation of Fruit Quality during Shelf-life at High Temperature Environment in 'Wonhwang' and 'Whasan' Pears ('원황' 및 '화산' 배의 숙도별 고온유통환경에서의 품질 평가)

  • Lee, Ug-Yong;Oh, Kyoung-Young;Choi, Jin-Ho;Hwang, Yong-Soo;Choi, Jong-Myung;Chun, Jong-Pil
    • Journal of Bio-Environment Control
    • /
    • v.20 no.3
    • /
    • pp.233-240
    • /
    • 2011
  • We evaluated the changes of fruit quality factors and the incidence of physiological disorders during the periods of high temperature environment in 'Wonhwang' and 'Whasan' pears to determine appropriate harvest time for exportation. In 'Wonhwang' pears, the fruits harvested at 130 days after full bloom (DAFB) showed 31.3 and 17.6N of flesh firmness after 5 and 10 days after simulated marketing at $30^{\circ}C$, respectively, while those of the fruits harvested at 135 DAFB lowered to 16.7 or 6.9N, respectively. Whereas, 'Whasan' pear showed higher firmness during 14 days of high marketing condition than 'Wonhwang' pears which represented 30.4, 26.5 and 21.6N in the fruits harvested 145, 150 and 155 DAFB, respectively. Higher soluble solid contents and lower acidity values observed in the late harvested fruits in both cultivar along with increased marketing period at $30^{\circ}C$. Late harvested 'Wonhwang' pears showed higher respiration rate and ethylene production than early harvested ones, while those of 'Whasan' pears showed lower values regardless of fruit maturity which represented less than 50% of 'Wonhwang' pears. The incidence of physiological disorders such as internal browning, water soaking, flesh spot decay, core breakdown and pithiness appeared more severely in the fruits of 'Wonhwang' in accordance with the progress of high temperature marketing and fruit maturity. Whereas, those symptoms were occurred only after 14 days of prolonged marketing time in 'Whasan' pears. Consequently, it was needed to pay more attention to determine the ripeness when the fruits exported to the country with high temperature environment, especially in the fruits of 'Wonhwang' pears showing rapid quality loss and severe physiological disorders.

Thermophysiological Responses of Wearing Safety Hat for Working at a Hot Environment (서열환경하에서 안전모 착용시의 인체생리학적 반응)

  • 박소진;김희은
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.26 no.1
    • /
    • pp.74-82
    • /
    • 2002
  • The present study is aimed to investigate the effect of the safety hat on the balance of body temperature by observation of the physiological response under hot working environment. The experiment was carried out in a climate chamber of 3$0^{\circ}C$, 50%RH for 70 minutes. To compare the two kinds of safety hat, 5 healthy male subjects worn safety hat without hole (called 'without hole') or safety hat with hole (called 'with hole') according to a randomized cross-over design. The main results of this study are as fellows: Rectal temperature and heart rate were significantly lower level in 'with hole'than in 'without hole'. The mean skin temperature was significantly higher in 'without hole'than in 'with hole'. Blood pressure were significantly low in 'with hole'. Sweat rate which was measured by weight loss before and after experiment was higher in 'without hole'. In subjective ratings, subjects replied more hot, more uncomfortable and more wet, they felt more fatigue in condition of 'without hole'. Work ability which was measured by a grip strength dynamometer was higher in 'with hole'. Safety hat which can be used for safety of the brain in work place is meaningful device of behavioral thermoregulatory response under the hot working environment. The safety hat which is designed for proper ventilation and hygiene can maintain the homeostasis of body temperature by releasing body temperature efficiently.