• Title/Summary/Keyword: Skin Surface

Search Result 1,141, Processing Time 0.036 seconds

Liquid Moisture Management and Surface Properties of the Fabric in Transient Condition (작업복 소재 직물의 액상 수분 전달 특성 및 표면특성 연구)

  • 유신정
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.1
    • /
    • pp.61-70
    • /
    • 2001
  • As important factors determining human sensorial comfort, liquid moisture management and surface properties of heat resistant workwear materials were examined. To figure out liquid moisture management properties of the test materials, absorption capacity, rate of absorption, and evaporation properties were assessed. A modified GATS(Gravimetric Absorbency Testing System) was used to measure the liquid moisture accumulation associated with the wicking of liquid moisture from sweating skin. The GATS procedure measures demand wettability of materials to take up liquid in a direction perpendicular to the fabric surface and it was modified to incorporate a special test cell and cover to assess absorption behavior in the presence of evaporation. Fabric stiffness, smoothness, number and the length of surface fibers, and an estimate of the contact area between the skin and fabric surface were measured to characterize the mechanical and surface properties of the test materials. Also an estimate of the force with which a fabric clings to moist skin was made using as wet-cling index.

  • PDF

Preparation of harvested skin using the Versajet Hydrosurgery System in full-thickness skin grafts

  • Choi, Seo Gil;Shin, Hyun Woo;Yoon, Kun Chul
    • Archives of Plastic Surgery
    • /
    • v.46 no.6
    • /
    • pp.603-607
    • /
    • 2019
  • During a full-thickness skin graft procedure, the thickness of the harvested donor skin is adjusted based on the location of the recipient site and the judgment of the surgeon. Conventionally, the thickness of the harvested skin is roughly adjusted using surgical instruments such as scalpels and scissors. However, this method is not only time-consuming, but also requires effort to obtain both the desired thickness of the harvested skin and a smooth surface of that skin. Moreover, there is a possibility of skin perforation. Hence, the authors devised a method of adjusting harvested skin thickness using the Versajet Hydrosurgery System. The Versajet device is a handheld hydrosurgical tool that delivers a high-speed jet stream of saline solution, which enables the precise debridement of tissue. This method makes it easier and faster for the surgeon to obtain the desired thickness of harvested skin. In addition, by obtaining a smooth surface and an even thickness of harvested donor skin, this technique may lead to improved graft viability.

Physiological Effects of Jaeum-Dan Essence on Human Skin (가미자음단 에센스가 인체 피부 생리에 미치는 영향)

  • Park Seong Kyu;Nam Gae Won;Lee Hae Kwang;Bae Ji Hyun;Kim Jin-han;Kim Youn-joon;Ko Jae Sook;Kang Seung Joo;Moon Seong Joon;Chang Ih Seoup
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.18 no.3
    • /
    • pp.729-733
    • /
    • 2004
  • Jaeum-Dan was reported new anti-aging effect formula previously. We investigated the physiological effects on human skin with Jaeum-Dan essence (JED). We made a skin application product as essence form contained oriental herbs, and measured various physiological effects such as skin moisture contents, red blood cell flow rates, skin surface temperature, corneocyte exfoliation and skin intensity when volunteers(female, n=40) used the application product for 4 weeks. The results were as follows: The skin moisture contents were not only increased in human face skin through using the product, but also red blood cell flow :rates in face skin were increased. After using the essence, the face skin temperature rose and corneocyte exfoliation was decreased. Furthermore the upper dermis intensity of skin in female face was subsequently increased 4 weeks later. The results indicate that the application product containing JED was improved the physiological effects of human facial skin..

A Study on Expressed Characteristics to SKIN On the Contemporary Interior Design (현대실내공간에서 나타난 ′SKIN′ 표현특성에 관한 연구)

  • 이희정;이정욱
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2003.05a
    • /
    • pp.135-138
    • /
    • 2003
  • Skin, the complex membrane that holds the body together, also embraces the full spectrum of design today-from product to architecture, fashion, and media. Every object has a skin. thick or thin, smooth or rough, porous or impermeable, the skin is the line between a hidden interior and an exterior we experience. Skin: Surface, Substance and Design is a compendium of products, furniture, fashion, architecture and media that expand the limits of what we understand as surface. Reflecting the convergence of natural and artificial life, this provocative a thesis shows how enhanced and simulated skins appear everywhere in today's world.

  • PDF

Study on Dermatology In Oriental Medicine (피부생리의 원리 연구)

  • Kim Byoung Soo;Kang Jung Soo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.16 no.6
    • /
    • pp.1110-1116
    • /
    • 2002
  • The skin(皮膚) separates epidermis(皮) and dermis(膚) in Oriental medicine. epidermis and hair come from ectoderm as dermis comes from mesoderm in embryology. Epidermis and hair belong to the Metal(金) and dermis belongs to the Earth(土) in Oriental medicine. The lung is related to the skin and hair. The skin surface is nourished by the essence from the lung, and the. lung has the function of sending wei-qi(衛氣.: defensive Energy) to the skin surface to guarantee body resistance. The skin takes nourishment from blood(血) and express by qi(氣). The supply of nutrients to the lung and skin relies on the function of the spleen, pancreas and subcutis. Flaming of the heart fire may scorch the essence of the lung-metal, inducing dermatosis.

How Skin Care Ingredient Concentrations Can Modulate the Effect of polyols and Oils on Skin Moisturization and Skin Surface Roughness (화장품 원료 중 폴리올, 오일 농도에 따른 피부 보습과 피부 표면 거칠기의 변화)

  • Nam, Gae-Won;Kim, Seung-Hun;Kim, Eun-Joo;Kim, Jin-Han;Chae, Byung-Guen;Lee, Hae-Kwang;Moon, Seong-Joon;Kang, Hak-Hee;Chang, Ih-Seop
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.31 no.4 s.54
    • /
    • pp.337-342
    • /
    • 2005
  • The aim of this study was to evaluate the influence of different skin care ingredient concentrations on the effect of polyols and oils on the human skin moisturization and skin surface roughness. Polyols and oils were essential ingredients to make a skin care formulation. But these were still not understood how much concentration(s) were tested on human skin in the aspect of efficacy and sensory. We studied to examine various concentrations of ingredient by cosmetic companies using noninvasive methods. Polyols were composed of glycerol and butylene glycol (BG) as 1:1 ratio, and oils were hydrogenated polydecene, cetyl ethylhexanoate and pentaerythrityl tetraethylhexanoate (PTO(R), Stearinerie Dubois Fils Co., France) as 1:1:1 ratio. All compounds were tested $0{\sim}27%dml$ Polyols and $0{\sim}35%dml$ oils in O/W emulsions. We investigated the effect of water contents and the effect of stratum corneum roughness in forearm skin after application of compounds. Water contents of the skin measured by skin capacitance and skin surface roughness measured visual scoring of skin surface biopsy through the scanning electron microscopy. Water contents of the skin were highly related to amount of polyols (to 20%) and oils (to 12%). Correlation coefficients were 0.971 and 0.985 respectively (p<0.01), 2 h after application. Skin surface roughness was positively correlated with polyol contents in concentration dependent manner, and depend on oils up to 6%. The ratio of coefficient was 2.5 to 1 (polyol to oils) by regression analysis. Further studies will be conducted with other ingredients such as surfactants, lipids and aqueous materials, and with ether methods for noninvasive measurement.

Novel technique for preventing make up deterioration using performance materials

  • Miyazawa, Masakazu;Nishikata, Kazuhiro;Mohri, Kunihiko
    • Proceedings of the SCSK Conference
    • /
    • 2003.09b
    • /
    • pp.370-378
    • /
    • 2003
  • MFD (Make up Film Deterioration) is a gradual deterioration of applied make up and is a common problem experienced by most foundation users. Our investigation revealed that for 64% of all make up users MFD is their greatest consern is using foundations. Known that the primary cause of MFD is sebum secretion. We observed that the length of time prior to onset of MFD in people who produce high level of sebum varies significantly from person to person. This suggests that other factors besides quantity of sebum production can affect MFD. Control over this factor would, we believe, be key to developing longer-lasting makeups. We studied the relationship between MFD and skin surface conditions. Our study revealed that furrows on the skin surface affect MFD significantly. Sebum reaches the skin surface from sebaceous glands and flows along furrow on the skin. If there are many deep furrows, it takes longer for sebum to overflow. But if the furrows are few or shallow, sebum quickly overflows and spreads over the skin surface where it can degrade the make up film. Therefore even when the volume of sebum produced is the same, the rate of MFD will be different depending on the number and shape of the furrows. A longer-lasting foundation could be produced by matching personal skin condition, but this would be very difficult because individual variations in texture are very large. Therefore we approached the problem by attempting to impose sebum resistance in under make up and foundation. We have developed two new materials and make up products based on our theory. A new fluoroalkyl acrylate-methacrylates copolymer designed for incorporation in under make up is extremely sebum resistant and sweat proof. Another new acrylate polymer designed for inclusion in foundation absorbs sebum and changes to a solid. Usage tests confirm it is possible to reduce MFD by using under make up and foundation which incorporate our new materials to cover where skin furrows are few or shallow

  • PDF

The Comparison of Various Shampoos on Skin pH in Normal Dogs (상용샴푸가 정상견의 피부 pH에 미치는 영향)

  • 오태호;박성준
    • Journal of Veterinary Clinics
    • /
    • v.18 no.4
    • /
    • pp.363-367
    • /
    • 2001
  • Shampoos are used routinely by a large number of veterinarians to treat skin diseases. Skin pH is affected by shampoos, however, known to occur. In order to evaluate the effect of shampoos on skin surface pH, we performed the measurement of skin pH using skin pH meter PH900 in five healthy mixed breed dogs. The seven commercial shampoos: Humilac, Sebocalm, Sebolytics, Etiderm, PEroxyderm, HyLyt and Zn-7 Derm were included in this study. The anatomical sites, right thorax was the highest pH (7.66$\pm$0.10), and the lowest pH (6.20$\pm$0.23) was left pinna. A statiscally significant decrease in skin pH was found 7 minutes after application of Humilac, Sebocalm, Etiderm, Peroxyderm (p<0.01) and Sebolytics (p<0.05). After 17 minutes of application skin surface pH was inclined to increase in every shampoos but the degree of increase was slight at 77 minutes. No statiscally significant differences were found in HyLy-T and Zn-7 Derm, but skin pH was normal range (6.2-7.8) after application. Throughout the experiment skin surface pH was maintained above pH 7.0 in detergent. The commercial shampoos, Humilac, Sebocalm, Etiderm, had the decreasing effect on skin surface pH in dogs. The other four shampoos maintain the skin pH normal range. The skin pH meter PH 900 was found simple and useful for skin pH measurement.

  • PDF

Auditory Evoked Skin Potential in Normal Subjects (정상 성인에서 청성유발 피부전위)

  • Heo, Seung-Deok;Jung, Dong-Keun;Suh, Duk-Joon;Kim, Gwang-Nyeon;Kim, Gi-Ryon;Kang, Myung-Koo;Kim, Lee-Suk
    • Speech Sciences
    • /
    • v.12 no.2
    • /
    • pp.81-88
    • /
    • 2005
  • Electrodermal activity(EDA) is a bio-electric signal which occurs at the skin surface during the sweating. EDA reflects the activity of the sympathetic axis of the autonomic nervous system. EDA is associated with the eccrine sweat gland at the palmar and plamar surface. This study was aimed to characterize the relationship between EDA and auditory stimulus intensities. Acoustic stimulus used in this study were 500 Hz, 1 kHz, 2 kHz of narrow band noise, which were representative of speech frequencies in audible range. Stimulus intensity between 90 and 30 dB in 10 dB within dynamic range. After deriving the minimum stimulus intensity(threshold of skin potential) which elicited skin potential, and then the latency and amplitude were derived from waveform of skin potential, each latency and amplitude were compared to stimulus intensity. The waveform of skin potential were recorded stably, and the threshold of skin potential appeared nearly the hearing threshold level of the participant. The latency was decreased and the amplitude was increased according to the increase of the stimulus intensity. These results suggest that auditory evoked skin potential can be applicable to auditory assessment and audiological diagnosis tool.

  • PDF

Development of Dry-type Surface Myoelectric Sensor for the Shape of the Reference Electrode and the Inter-Electrode Distance (기준전극의 형상과 입력전극사이의 간격을 고려한 건식형 표면 근전위 센서 개발)

  • Choi, Gi-Won;Choe, Gyu-Ha
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.12
    • /
    • pp.550-557
    • /
    • 2006
  • This paper proposes a dry-type surface myoelectric sensor for the myoelectric hand prosthesis. The designed surface myoelectric sensor is composed of skin interface and processing circuits. The skin interface has one reference and two input electrodes, and the reference electrode is located in the center of two input electrodes. In this paper is proposed two types of sensors with the circle- and bar-shaped reference electrode, but all input electrodes are the bar-shaped. The metal material of the electrodes is the stainless steel (SUS440) that endures sweat and wet conditions. Considering the conduction velocity and the median frequency of the myoelectric signal, the inter-electrode distance (IED) between two input electrodes as 18mm, 20mm, and 22mm is selected. The signal processing circuit consists of a differential amplifier with a band pass filter, a band rejection filter for rejecting 60Hz power-line noise, amplifiers, and a mean absolute value(MAV) circuit. Using SUS440, six prototype skin interface with different reference electrode shape and IED is fabricated, and their output characteristics are evaluated by output signal obtained from the forearm of a healthy subject. The experimental results show that the skin interface with parallel bar shape and the 18mm IED has a good output characteristics. The fabricated dry-type surface myoelectric sensor is evaluated for the upper-limb amputee.