• 제목/요약/키워드: Skin Plate

검색결과 262건 처리시간 0.024초

금속 샌드위치 판재 대면적 롤 프로젝션 용접에 관한 연구 : Part 2 - 수치 해석 (A Study on Large Area Roll Projection Welding for Metallic Sandwich Plate : Part 2 - Numerical Analysis)

  • 김종화;안준수;나석주
    • Journal of Welding and Joining
    • /
    • 제27권3호
    • /
    • pp.92-96
    • /
    • 2009
  • Metallic sandwich plate has many good properties such as high specific stiffness, high specific strength, good impact absorptivity, effective thermal insulation and soundproofing. In our study, a new bonding method, 3-layer roll projection welding, is introduced to fabricate the metallic sandwich plate. The new method uses a pair of roll electrodes like the seam welding, and projection welding is made at two internal interfaces of the 3-layer weldment consisting of a structured inner sheet and a pair of skin sheets. During the welding process, skin sheet temperature are measured to produce metallic sandwich plate with uniform and good quality. But it is difficult to observe or measure the temperature at the welding points during welding process because the welding points exist at the internal interfaces. Therefore FEM numerical analysis using ABAQUS is conducted to estimate the generated heat at the welding points with different welding conditions.

Pre-contoured reconstruction plate fabricated via three-dimensional printed bending support

  • Song, In-Seok;Ryu, Jae-Jun;Choi, Young-Jun;Lee, Ui-Lyong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제47권3호
    • /
    • pp.233-236
    • /
    • 2021
  • A mandibular continuity defect can be repaired using either a prosthetic device or autogenous bone. A titanium reconstruction plate can be used with a localized or vascularized flap over the defect of the mandible. Unfortunately, the plate may fail due to plate exposure, screw loosening, fracture, or infection, and will need to be removed. Plate exposure though the skin or mucosa is one of the main reasons for failure. In the present work, the authors introduced a lingually positioned reconstruction plate fabricated via three-dimensional printed bending support. This custom reconstruction plate can avoid plate re-exposure as well as reduce surgical errors and operation time.

Allium속 향신채 첨가가 찐어묵의 저장성과 품질에 미치는 영향 (The Effect of Herbs of Alium Species on Quality and Storage Characteristics of Kamaboko)

  • 황지희;조은자
    • 동아시아식생활학회지
    • /
    • 제11권1호
    • /
    • pp.33-43
    • /
    • 2001
  • The effects of the addition of herbs belonging to Allium species on the quality and storage characteristics of kamaboko were studied. The herbs employed in the study were garlic (Allium sativum for.Pekinenese Makino), leek(.Allium tuberosum Roth), onion(Allium cepa Linnaeus), and onion skin. water activity(Aw) , pH, TBA, VBN, microbial load, textural characteristics and sensory evaluation were tested. 1. Aw of all the samples decreased on storage, the Aw on lower day ranged from 0.937~o.950. All thesamples containing herbs retained the pH 6 ~7 during the entire storage period even though it decreased gradually on storage. 2. In general, TBA and VBN of the samples containing herbs were lower than the control. The sample containing 3% onion skin showed the lowest TBA and VBN value. 3. The total plate count of the samples containing herbs was low compared to the control even though the total count increased during the storage. The samples containing 3% garlic and 3% onion skin showed the lowest total plate count on 20 days of storage. 4. The sample with garlic showed remarkably low value in sensory evaluation. The samples containing onion and onion skin, however, reached to the high sensory points as storage period increased. They received high points in taste as well as overall acceptance.

  • PDF

신체적 자극과 심리적 자극에서 교감신경피부반응에 대한 탐색연구 (Exploratory Study on Sympathetic Skin Response to Physical and Psychological Stimulation)

  • 김기련;정동근
    • 대한의용생체공학회:의공학회지
    • /
    • 제45권1호
    • /
    • pp.37-42
    • /
    • 2024
  • In this study, we explored the possibility of using sympathetic skin response (SSR), a type of electrodermal activity (EDA), as a method of evaluating a subject's responsiveness to physical or psychological stimulation. To provide physical and psychological stimulation, walking on an acupressure plate and a roller coaster virtual reality experience wearing an HMD (head mounted display) were used. Walking on an acupressure plate significantly increased the SSR signal compared to walking on the bare floor. Additionally, it was observed that the SSR response significantly increased while the subject was wearing an HMD and experiencing a roller coaster compared to the resting state of sitting on a chair. The SSR response to physical or psychological stimulation increased in all subjects, but the degree of reactivity differed. These experimental results suggested that sympathetic skin response (SSR) is a useful tool as a biosignal that can be used to evaluate the human body's responsiveness to physical stimulation or psychological stimulation using virtual reality.

목제(木製) 프러쉬 문의 함수율 변동에 따른 틀어짐과 좌굴 예측모델 (I) : 예측모델과 실측치 비교 (Warping and Buckling Prediction Model of Wooden Hollow Core Flush Door due to Moisture Content Change (I) : Comparison of Prediction Model with Experimental Results)

  • 강욱;정희석
    • Journal of the Korean Wood Science and Technology
    • /
    • 제27권3호
    • /
    • pp.99-116
    • /
    • 1999
  • 목재 hollow core 형태의 프러쉬문은 가구과 목공품 산업에서 주요 제품으로 사용중 틀어짐과 좌굴은 매우 중요한 문제이다. 틀어짐은 도아 표면재 간의 물리적 및 기계적 성질의 차이에 기인된다고 알려져 있다. 본 연구는 수치적 모델덜을 사용해 틀어짐과 좌굴을 예측하는데 그 목적이 있다. 여러 환경조건에서 경질섬유판과 합판으로 만들어진 프러쉬문에 대한 각 모델들과 실측치간의 비교를 하였다. 문의 틀어짐과 좌굴을 예측하기 위해 3가지 연속체 모델, 즉 보, 판상 및 판상-좌굴 모델이 채택되었다. 틀어짐은 고습에서보다 저습에서 현저하게 훨씬 현저하게 발생되었으며, 포아송 비를 고려한 판상 모델은 저습에서 보 모델보다 더 정확하게 틀어짐을 예측할 수 있었다. 그러나 고습에서 좌굴이 문의 표면재에 발생하기 때문에 판상-좌굴 모델 이 모든 시험범위에서 가장 적절하였다.

  • PDF

Shear strength of connections between open and closed steel-concrete composite sandwich structures

  • Kim, Woo-Bum;Choi, Byong Jeong
    • Steel and Composite Structures
    • /
    • 제11권2호
    • /
    • pp.169-181
    • /
    • 2011
  • The behavior of connections between open sandwich slabs and double steel skin composite walls in steel plate-concrete(SC) structure is investigated by a series of experimental programs to identify the roles of components in the transfer of forces. Such connections are supposed to transfer shear by the action of friction on the interface between the steel surface and the concrete surface, as well as the shear resistance of the bottom steel plate attached to the wall. Experimental observation showed that shear transfer in slabs subjected to shear in short spans is explained by direct force transfer via diagonal struts and indirect force transfer via truss actions. Shear resistance at the interface is enhanced by the shear capacity of the shear plate as well as friction caused by the compressive force along the wall plate. Shear friction resistance along the wall plate was deduced from experimental observation. Finally, the appropriate design strength of the connection is proposed for a practical design purpose.

치료보조기구의 제작 및 유용성 평가 (The evaluation of usefulness of the newly manufactured immobilization device)

  • 서석진;김찬용;이제희;박흥득
    • 대한방사선치료학회지
    • /
    • 제17권1호
    • /
    • pp.45-55
    • /
    • 2005
  • 목적 : 최근의 방사선치료는 정상조직의 장애는 최대한 줄이고 종양조직 선량을 높여 치료효과를 극대화 하기위하여 3차원적으로 발전되어왔으며, 이에 따른 환자 체위고정을 위한 고정기구와 보조기구의 개발이 필수적으로 요구되고 있다. 본원에서는 MR head holder, 개방형 head holder, Plan CT couch plate를 자체 제작하여 그 유용성을 평가하고 분석하였으며, 임상에 적용한 결과를 보고하고자 한다. 대상 및 방법 : MR head holder를 제작하여 진단 MR영상과 치료계획용 MR영상을 CT영상과 fusion하여 두 영상의 일치성과 정확성을 분석하였고, 개방형 head holder를 제작하여 피부선량과 선량감약 정도를 알아보았으며, 6 mm 아크릴판에 스티로폼을 부착하는 CT couch plate를 제작하여 hard plate와 artifact 정도를 비교하였다. 결과 : Head holder를 사용하지 않은 fusion영상보다 2 mm이내의 오차로 정확한 fusion을 할 수 있었고, 개방형 head holder를 사용함에 따라 피부선량을 최대 2배 이상 줄일 수 있었고, $20\%$이상 선량이 감약되는 것을 최소화할 수 있었다. Plan CT couch plate를 사용했을 때는 2단 연결, 부착 식으로 제작하여 사용이 간편하고 artifact를 현저하게 줄일 수 있었다. 결론 : MR 영상에서도 기준 좌표점을 확인할 수 있어 정확한 MR / CT fusion을 시행할 수 있었고, 향후 PET, 초음파 영상의 fusion도 연구되어야 할 것으로 사료되며, 이에 따른 고정기구의 개발도 필수적이라 할 수 있겠다. 개방형 head holder를 사용함으로써 피부선량과 선량 감약을 감소시킬 수 있었다. 이러한 치료보조기구를 자체 제작하여 고가의 외국상품을 대체할 수 있어 비용은 절감할 수 있었지만 견고성에서는 떨어지므로 가볍고 선량 감약이 적으며 강도가 강한 특수 재질의 치료보조기구가 개발되어야 할 것으로 사료된다.

  • PDF

방오 도료가 도장된 평판에 대한 항력 성능 연구 (Study on the Drag Performance of the Flat Plates Treated by Antifouling Paints)

  • 백부근;김경열;조성락;안종우;조상래;김경래;정용욱
    • 대한조선학회논문집
    • /
    • 제50권6호
    • /
    • pp.399-406
    • /
    • 2013
  • In the present study, the flat plate model test method is developed to evaluate the skin friction of the marine coating in the cavitation tunnel. Six-component force balance is used to measure the profile drag of the flat plate and strut. LDV(laser Doppler velocimetry) technique is also employed to evaluate the drag and to figure out the reason of the drag reduction. The flow velocities above the surface can be used to assess the skin friction, combined with direct force measurement. Since the vortical structure in the coherent turbulence structure influences on the skin friction in the high Reynolds number regime, the interaction between the turbulence structure and the surface wall is paying more attention. This sort of thing is important in the passive control of the turbulent boundary layer because the skin friction can't be determined only by wall condition. As complicated flow phenomena exist around a paint film, systematic measurement and analysis are necessary to evaluate the skin friction appropriately.

피부검판 고정술을 이용한 하안검 내반증의 교정 (Correction of Lowerlid Entropion by Using Skin-tarsal Fixation Method)

  • 홍정수;김한구;김우섭;김승홍
    • Archives of Plastic Surgery
    • /
    • 제32권3호
    • /
    • pp.397-402
    • /
    • 2005
  • For its lowerlid entropion correction, nonsurgical eyelid suture or surgical eyelid suture can be employed. Different types of surgical eyelid suture such as the Hotz method and the Callahan method, are generally performed, but were not sufficient for correcting of entropion. In our hospital we performed modified skin-tarsal fixation on 15 patients, 5 male and 10 female from January 20, 1999 to December 16, 2002. We corrected lower eyelid entropion with the excision of the skin and orbicularis oculi muscle and buried suture of tarsal plate and dermis which is a variant of the Callahan method. All the patients were satisfied with the operation results, and there was no case of recurrence of the lower eyelid pricking the cornea. During the 6 months period after the operation, the lower eyelids slightly turned inward but there was no further progression. The correction was performed excessively, therefore there was no case of recurrence after the operation and the results were satisfactory. There developed a dimple at the suture margin caused by skin contraction but it usually disappeared within 2 months after the operation. To avoid recurrence and to achieve satisfactory results, the orbicularis oculi muscle must be totally resected at the ciliary margin. We resected ciliary as well as pretarsal portion of orbicularis oculi muscle. Also, since most of the recurrences are originated from the medial side, the medial portion of skin flap must be tightly fixed to avoid recurrence and the upper part of the dermis should be fixed tightly to the lower border of the tarsal plate.

견봉쇄골탈구와 원위쇄골골절에서 소절개를 이용한 Wolter금속판 내고정술 (Minimal incision Wolter Plate Fixation on the Displaced Lateral End Fracture of the Clavicle and the Acromioclayicular Dislocation)

  • 고상훈
    • Clinics in Shoulder and Elbow
    • /
    • 제5권1호
    • /
    • pp.23-28
    • /
    • 2002
  • Purpose Displaced lateral end fracture of clavicle and acromioclavicular dislocation type Ⅲ∼Ⅵ may be required surgical treatment. Material and Methods : From May 1998 to March 2001, we operated with Welter plate with minimal incision by one surgeon. Immediately, pendulum and passive exercise was initiated after surgery. The shoulder function was evaluated using UCLA score. Average follow up was on 28(12∼45) months. Results : All 11 patients were regained satisfactory function. Average UCLA score was 31.9(29~35) at last follow up. Conclusion . The merit of Welter plate fixation with minimal incision is simple technique, reduced surgical time, smaller scar than large plate, strong fixation, early exercise, reduced implant failure. The disadvantage is expensive, skin irritatatation by long hook. But Welter plate fixation with minimal incision is a good method of internal fixation and excellent clinical result in surgical treatment of type H displaced lateral end fracture of the clavicle and type Ⅲ∼Ⅵ acromioclavicular dislocation.