• 제목/요약/키워드: Skin Depth

검색결과 371건 처리시간 0.027초

Value Addition Span of Silkworm Cocoon - Time for Utility Optimization

  • Reddy, R. Manohar
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제17권1호
    • /
    • pp.109-113
    • /
    • 2008
  • Realizing the scope of utilizing by-products of silk cocoons by applying appropriate methods is the immediate crave to optimize returns. The nutritive value of pupae suits for human diet, feed for poultry, carps, fish, rabbits, piggery and dogs. The pupal skin, fat, oil, cocoon palade have applications in oleo chemical, soap, glycerin, cosmetic, artificial fibres, membranes and n-triacontanol isolation. The pupal proteins Chitin, Shinki fibroin, Serrapeptidase, glucosamine are latent precursors of post surgical, anti-carcinogenic, anti-inflammative, anti-bacterial, anti-histaminic, gastric, hepatitis, pancreatitis, leukocytopenia, neurological, ophthalmic, blood pressure, cardiac and diabetic medicines and for preparation of vitamins A, E and K. The silk and its proteins sericin and fibroin are potentially used for wound healing, diabetes, impotence, sinusitis, arthritis, edema, cystitis, epididymitis, tissue regeneration, cancer, post-surgical trauma and used as anti-oxidatives, bio-adhesives, ultra violet screens and bio-active textiles. The waste cocoons can be used in making art crafts like garlands, carpets, overcoats, decoratives and greeting cards. The in-depth research towards utility optimization and make aware this reality to sericulturists, reelers, weavers, traders, entrepreneurs, policy makers etc., is the upright want of the today's Sericulture industry.

평면형 유도결합 플라즈마 장치에서의 RF 전력 전달 특성 계산 (Characteristics calculation on radio frequency power transfer in a planar inductively coupled plasma source)

  • 이정순;정태훈
    • 한국진공학회지
    • /
    • 제8권3B호
    • /
    • pp.368-375
    • /
    • 1999
  • The Maxwell equation and the transformer equivalent-circuit model are applied to a radio frequency planar inductively coupled plasma. The spatial distribution of the vector potential, the magnetic field, and the electric field are obtained analytically. As a result, the plasma current, the mutual inductance between the coil and the plasma, and the self inductance of plasma are found to increase with increasing skin depth. The spatial distribution of absorbed power has maximum where the antenna coil exists, and has a similar profile to that of the induced electric field. The power transfer efficiency is found to increase with increasing gas pressure before a saturation around p+ 20mTorr, while it shows an increase with the plasma density before a slight decrease around a density of $5\times10^{11}/\textrm{cm}^3$.

  • PDF

Simulation Study of Solar Wind Interaction with Lunar Magnetic Fields

  • Choi, Cheong Rim;Dokgo, Kyunghwan;Woo, Chang Ho;Min, Kyoung Wook
    • Journal of Astronomy and Space Sciences
    • /
    • 제37권1호
    • /
    • pp.35-42
    • /
    • 2020
  • Particle-in-cell simulations were performed to understand the interaction of the solar wind with localized magnetic fields on the sunlit surface of the Moon. The results indicated a mini-magnetosphere was formed which had a thin magnetopause with the thickness of the electron skin depth. It was also found that the solar wind penetrated into the cavity of the magnetosphere intermittently rather than in a steady manner. The solar wind that moved around the magnetosphere was observed to hit the surface of the Moon, implying that it may be the cause of the lunar swirl formation on the surface.

강재의 유도가열 방법의 수치적 승온 해석 (A Numerical Study on Temperature Profiles of Steel Plates Heated by Induction Heater)

  • 김형진;정원철;조병수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1412-1416
    • /
    • 2003
  • Induction Heaters are commonly used in heating steel strip product, because it can rapidly and efficiently heat steel strip/bar. In this study, a inductive heating model is developed and the predictions are compared with measured temperatures. The temperatures are measured from POSCO thin-slab rolling facility (so called Minimill). Induction heater is installed between reduction unit and holding furnace This induction heater raise the temperature of steel bars from $930^{\circ}C$ to about $1100^{\circ}C$ which gives the required temperature for finishing mill process after holding period at holding furnace. Unlike other simple equation models, this model allows us to predict temperature profiles of sections of steel bars.

  • PDF

Characteristics of Specific Absorption Rate (SAR) in Electromagnetic (EM) Dosimetry

  • Hwang, Sun-Tae;Choi, Kil-Oung
    • Journal of Radiation Protection and Research
    • /
    • 제25권2호
    • /
    • pp.109-114
    • /
    • 2000
  • The SI unit of specific absorption rate (SAR) in W/kg in the electromagnetic (EM) field as non-ionizing radiation is exactly same as the SI unit of absorbed dose rate in Gy/s in the ionizing radiation field. The SI unit of both physical quantities can be expressed in $[m^{\cdot}s^{-3}]$. Where, the unit of absorbed dose, Gy stands for Gray. In EM biological interactions, the SAR equations are derived and the characteristics of EM field energy absorption in terms of the SAR are discussed and described on the mathematical basis.

  • PDF

Epilepsy Surgery of the Cerebral Paragonimiasis

  • Lee, Woo-Jong;Koh, Eun-Jeong;Choi, Ha-Young
    • Journal of Korean Neurosurgical Society
    • /
    • 제39권2호
    • /
    • pp.114-119
    • /
    • 2006
  • Objective : The authors investigate appropriate evaluation and surgical methods in treatment of the cerebral paragonimiasis accompanying epilepsy. Methods : Thirteen patients with the cerebral paragonimiasis accompanying epilepsy were included for this study. Preoperative evaluation methods included history taking, skin and serologic tests for Paragonimus westermani, neurologic examinations, computerized tomography, magnetic resonance imaging, amytal test, PET or SPECT, and video-EEG monitoring with depth and subdural grid electrodes. Seizure outcome was evaluated according to Engel's classification. Results : Surgical methods were temporal lobectomy including lesions in six, lesionectomy in five, and temporal lobectomy plus lesionectomy in two. Postoperative neurological complications were not noticed, and seizure outcomes were class I in 12 patients [92%], class II in one [8%]. Conclusion : In patients with a cerebral paragonimiasis accompanying epilepsy, further evaluation methods must be done to define the epileptogenic zone, and complete resection of the epileptogenic zone with different surgical methods should be performed for seizure control.

주파수 변화에 따른 축대칭 관결함의 와전류탐상 수치해석 (Numerical Analysis of Eddy Current Testing for Pipe with Axi-symmetric Defect According to Frequency Changes)

  • 서장원;이향범;정태언
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.102-104
    • /
    • 2001
  • This paper presents a numerical analysis of the eddy current testing for pipe with axi-symmetric defect according to frequency changes using the finite element method(FEM). The defects used in this analysis are inner and outer axi-symmetric type. In order to obtain the behaviors of the signals by changing the frequency, the defects with different depths are modeled and analyzed using FEM. It is important to choose proper frequency because of the effect of skin depth in eddy current testing. This paper describes signal characteristics of each defects as frequency is changed.

  • PDF

와전류에 의한 저주파 자기장 차폐 성능 평가 (Performance Evaluation of Low Frequency Magnetic Field Shielding by Eddy-Current)

  • 최학윤
    • 조명전기설비학회논문지
    • /
    • 제24권9호
    • /
    • pp.124-128
    • /
    • 2010
  • In this paper, the shielding effectiveness of aluminum shielded room with using eddy-current is calculated and measured after fabricated. The size and thickness of shielded room are decided as $2.4{\times}2.4{\times}2.4[m^3]$ and 12[mm] after AC shielding characteristics by eddy-current of conductive materials is analyzed. To verify the shielding effectiveness, a rectangular helmholtz coil is fabricated to generate magnetic field of 1.37[${\mu}T$] and measured magnetic field inside shielding room for 0.01~10[Hz]. According to calculations and measurements, AC Shielding effectiveness by eddy-current in aluminum is very small for 0.01~2[Hz] and 5 times to 11 times for 5~10[Hz].

손 이미지의 기하학적 특징을 이용한 중심 검출 (The Center of Hand Detection Using Geometric feature of Hand Image)

  • 김민하;이상걸;조재현;차의영
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2012년도 제46차 하계학술발표논문집 20권2호
    • /
    • pp.311-313
    • /
    • 2012
  • 본 논문에서는 RGBD(Red Green Blue Depth)센서를 이용하여 얻은 영상의 깊이 정보와 손 이미지의 기하학적 특징을 이용하여 손의 중심을 검출하는 방법을 제안한다. 영상의 깊이 정보와 피부색 정보를 이용하여 손 영역을 검출한다. 검출된 손의 기하학적 정보로 손에 대한 볼록 외피(convex hull)를 형성한다. 볼록 외피의 정점들(vertices)의 위치 정보를 이용하여 손의 중심을 찾는다. 손의 중심은 손의 위치를 추적하거나 손가락 개수를 구하는 것 등에 이용될 수 있다. 이러한 응용은 인간과 컴퓨터의 상호작용(HCI, Human Computer Interface)을 이용한 시스템에 적용될 수 있다.

  • PDF

SIP 말뚝의 주면마찰 특성에 관한 연구 (A Study on the Skin Friction Characteristics of SIP(Soil-cement Injected Precast Pile))

  • 천병식;임해식;강재모;김도형;지원백
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.583-588
    • /
    • 2002
  • As environmental problem in course of construction has been a matter of interest, noise and vibration in the process of piling are considered as a serious problem. For this reason, the use of SIP method inserting pile as soon as boring and cement grouting is rapidly increasing for preventing vibration and noise. But a resonable bearing capacity formula for SIP method does not exit and even the standard specification for domestic condition isn't formed, though the lateral friction between cement paste and the ground does an important role and boring depth largely influences to the design bearing capacity, applying the SIP method . Therefore, the lateral friction was analyzed after the direct shear test worked with the lateral face of SIP and the soil.

  • PDF