• Title/Summary/Keyword: Skin Depth

Search Result 371, Processing Time 0.029 seconds

Development of An Onion Peeler ( II ) - Air injection type peeling equipment - (양파 박피기 개발 (II) - 공기분사식 박피장치 -)

  • 민영봉;김성태;강동현;최선웅;유준현
    • Journal of Biosystems Engineering
    • /
    • v.27 no.4
    • /
    • pp.311-316
    • /
    • 2002
  • This study was carried out to investigate the optimum operating conditions of the air injection type onion peeling device which could be attached to a prototype onion peeler. An onion, stem and root was cut and some vertical line was dug in 1 mm depth on the skin, was put on the two parallel rollers. The diameters of the rollers were 105 mm and the ratio of peripheral velocity was 3:2, and moved by a geared motor. Air from the nozzle with high pressure and velocity was jetted to the rotating onion on the revolving rollers, and then the skin of the onion was stripped. On the test, the rolling characteristics of the experimental materials were measured. The effective peeling conditions were, the number of digging line on the skin of the onion was 4, and the air jet pressure was above 392.3 kPa(4.0 kg/$\textrm{cm}^2$) when the peripheral velocity was at 2.4 m/s. On these conditions, time requirement to peel an onion was less than 2 sec.

Planning of the Blind Position Considering Thermal Performance in the Intermediate Space of Double-Skin Facade

  • Choi Dong-Hee;Jo Jae-Hun;Seok Ho-Tae;Yeo Myoung-Souk;Kim Kwang-Woo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.14 no.2
    • /
    • pp.57-65
    • /
    • 2006
  • The blinds in the intermediate space are installed to block the direct solar radiation. As the blind divides the airflow of intermediate space into two parts, thermal performance of Double-Skin Facade(DSF) is affected by the blind position. Therefore the blind position should be planned with careful consideration in order to maximize the thermal performance of DSF. In this study, CFD was performed to analyze the effect of blind position in multistory-type DSF in variation of other DSF elements. The simulation results showed that the case with narrow depth of intermediate space and outlet on upper side of outer-facade, it is profitable to place blind as close as possible to the outer facade. In the other cases, the blind should maintain 0.15m distance from outer facade.

Calibration of Double-skin Simulation Model Depending on Configuration And Impact of Local Weather Information (이중외피 형상에 따른 모델 보정과 local 기상 정보의 필요성)

  • Yoon, Kyeong-Soo;Kim, Deuk-Woo;Lee, Keon-Ho;Park, Cheol-Soo
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.142-147
    • /
    • 2009
  • In order to achieve performance assessment and optimal control of a double-skin system, an accurate simulation model is required. In the previous study, a lumped simulation model of such system was developed. As a follow-up of the previous research, the first objective of this paper is to investigate how the mathematical model should be calibrated according to system configuration(cavity width, depth, height, airflow pattern, local environment, etc.). And the second objective of this study is to discuss the effect of local weather information. In conclusion, this paper describes that the model should be recalibrated according to configuration. And it is necessary to have local weather information for accurate prediction and optimal control of the system.

  • PDF

Real time tracking of multiple humans for mobile robot application

  • Park, Joon-Hyuk;Park, Byung-Soo;Lee, Seok;Park, Sung-Kee;Kim, Munsang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.100.3-100
    • /
    • 2002
  • This paper presents the method for detection and tracking of multiple humans robustly in mobile platform. The perception of human is performed in real time through the processing of images acquired from a moving stereo vision system. We performed multi-cue integration such as human shape, skin color and depth information to detect and track each human in moving background scene. Human shape is measured by edge-based template matching on distance transformed image. Improving robustness for human detection, we apply the human face skin color in HSV color space. And we could increase the accuracy and the robustness in both detection and tracking by applying random sampling stochastic estimati...

  • PDF

A study on the PAL according to thermal characteristic of building skin and perimeter zone depth (건물 외피의 열특성과 외주부 깊이에 따른 PAL에 관한 연구)

  • Kim, Ji-Hye;Kim, Hwan-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.2
    • /
    • pp.33-38
    • /
    • 2010
  • The perimeter zone is space which receives a significant effect of ambient condition, it is necessary to improve the thermal performance in order to building energy saving. For this reason, a lot of study about the active approach is being performed, such as perimeter-less air conditioning system. But the performance of the perimeter zone is necessary to improve, through the passive approach. Therefore, the purpose of this study is to provide basic materials of energy-saving design of perimeter zone, based of the PAL that simulation changing the thickness of insulation and the rate of windows.

Scalp reconstruction using the reverse temporalis muscle flap: a case report

  • Na, Youngsu;Shin, Donghyeok;Choi, Hyungon;Kim, Jeenam;Lee, Myungchul
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.3
    • /
    • pp.134-138
    • /
    • 2022
  • The scalp is the thickest skin in the body and protects the intracranial structures. The coverage of a large scalp defect is a difficult surgical procedure, the full details of which must be considered prior to the procedure, such as defect size and depth, and various factors related to the patient's general condition. Although a free flap is the recommended surgical procedure to cover large scalp defects, it is a high-risk operation that is not appropriate for all patients. As such, other surgical options must be explored. We present the case of a patient with an ulcer on the scalp after wide excision and split-thickness skin graft for squamous cell cancer. We successfully performed a reverse temporalis muscle flap for this patient.

The Measurements of Energy and Distribution of Scattered Electrons in Therapeutic X-Ray Beam (치료 방사선 선속(Flux)에 포함된 산란전자의 분포와 에너지 측정)

  • Vahc, Young-Woo;Park, Kyung-Ran;Ohyun Kwon;Lee, Yong-Ha;Kim, Tae-Hong;Kim, Sookil
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.1-8
    • /
    • 2002
  • Accurate knowledge of the distribution of contamination electrons ( which comes from mainly gantry head by Compton scattering, pair production, and tray: henceforth called leptons ) at the surface and in the first centimeters of tissue is essential for the clinical practice of radiation oncology. Such lepton tends to reduce or eliminate the ‘skin-sparing’ advantage of megavoltage photon beam radiotherapy, This information is needed to prescribe a absorbed dose to a skin volume at a few millimeter depth in high energy therapeutic radiation photon beam All experiments were done with 15 MV photon beam from a dual energy linear accelerator (Clinac 1800, Varian). Field size is defined by ranged from 10.0$\times$10.0 to 30.0$\times$30.0 $\textrm{cm}^2$. The absorbed dose and distribution of leptons in therapeutic radiation beam (15 MV) are investigated by means of variable blocked beams of 30.0$\times$30.0 $\textrm{cm}^2$ and dose beam profiles partly removed leptons with a copper plate. A numerous leptons mainly are distributed as shape of broad cone in the central photon beam and leptons path length in the water are shorter than 2.5 cm because of the leptons energy having around 3.0 MeV. These results clearly appears that the subtraction of leptons from the total depth dose curve not only lower the absolute dose in the buildup region and surface dose, it also causes a shift of d$_{max}$ to a deeper depth.

  • PDF

The Change of Burn Depth within 24 Hours after Burn in the Standardized Burn Model (표준화된 화상 모델에서 화상 후 첫 24시간 내의 화상 깊이의 변화)

  • Son, Dae Gu;Choi, Tae Hyun;Kwon, Sun Young
    • Archives of Plastic Surgery
    • /
    • v.35 no.4
    • /
    • pp.373-378
    • /
    • 2008
  • Purpose: In full thickness burn, the depth of burn is known to increase until around 1-3 days after the burn. However, no study on how the depth increase during the first 24 hours has been conducted. Therefore, the authors investigated how the depth of burn changes within the first 24 hours after the burn by using the standardized burn model. Methods: A total of four experiments on pigs were carried out for this study. Experiment 1 was performed to examine how temperature affects the depth of burn. The digitally controlled aluminum thermal block was set at different temperatures-80, 90 and 100 degrees in Celsius, respectively. Then the pig was exposed to the block for 15 seconds each time. The time exposed to heat was set as a variable for the Experiment 2. The temperature was maintained at 80 degrees Celsius, and the pig was contacted with the thermal block for 5, 10 and 20 seconds, respectively. The biopsy of the tissues were performed in one hour, 6 hours, 24 hours, and 7 days after the burn. After hematoxylin and eosin staining a percentage of the depth from a basement membrane of epidermis to the deepest tissue damaged by the burn against total dermal thickness was measured. Results: In Experiment 1, the depth of burn increased considerably as time passed by. At all three temperatures, differences in depths measured in 6 and 24 hours, and in 1 hour and 7 days were both significant. In addition, the depth deepened as the temperature went higher. In the case of Experiment 2, the depth of burn also increased significantly as time passed by. At all three times, differences in depth measured in 6 and 24 hours, and in 1 hour and 7 days were also significant. Moreover, the depth extended with longer contact time when it was compared according to the time. Conclusion: Full thickness burn progressed rapidly from 6 to 24 hours after the burn and the depth of burn was almost decided within the first 24 hours after the burn. On the other hand, partial thickness burn also advanced from 6 to 24 hours after the burn but the depth deepened at slower level.

Relationship between needle depth for lumbar transforaminal epidural injection and patients' height and weight using magnetic resonance imaging

  • John, Hyunji;Sohn, Kyomin;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • v.35 no.3
    • /
    • pp.345-352
    • /
    • 2022
  • Background: Optimal needle depth in transforaminal epidural injection (TFEI) is determined by body measurements and is influenced by the needle entry angle. Physician can choose the appropriate needle length and perform the procedure more effectively if depth is predicted in advance. Methods: This retrospective study included patients with lumbosacral pain from a single university hospital. The skin depth from the target point was measured using magnetic resonance imaging transverse images. The depth was measured bilaterally for L4 and L5 TFEIs at 15°, 20°, and 25° oblique angles from the spinous process. Results: A total of 4,632 measurements of 386 patients were included. The lengths of the left and right TFEI at the same level and oblique angle were assessed, and no statistical differences were identified. Therefore, linear regression analysis was performed for bilateral L4 and L5 TFEIs. The R-squared values of height and weight combined were higher than the height, weight, and body mass index (BMI). The following equation was established: Depth (mm) = a - b (height, cm) + c (weight, kg). Based on the equation, maximal BMI capable with a 23G, 3.5-inch, Quincke-type point spinal needle was presented for three different angles (15°, 20°, and 25°) at lumbar levels L4 and L5. Conclusions: The maximal BMI that derived from the formulated equation is listed on the table, which can help in preparations for morbid obesity. If a patient has bigger BMI than the one in the table, the clinician should prepare longer needle than the usual spinal needle.

Human-Computer Natur al User Inter face Based on Hand Motion Detection and Tracking

  • Xu, Wenkai;Lee, Eung-Joo
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.4
    • /
    • pp.501-507
    • /
    • 2012
  • Human body motion is a non-verbal part for interaction or movement that can be used to involves real world and virtual world. In this paper, we explain a study on natural user interface (NUI) in human hand motion recognition using RGB color information and depth information by Kinect camera from Microsoft Corporation. To achieve the goal, hand tracking and gesture recognition have no major dependencies of the work environment, lighting or users' skin color, libraries of particular use for natural interaction and Kinect device, which serves to provide RGB images of the environment and the depth map of the scene were used. An improved Camshift tracking algorithm is used to tracking hand motion, the experimental results show out it has better performance than Camshift algorithm, and it has higher stability and accuracy as well.