• Title/Summary/Keyword: Size measurements

Search Result 1,912, Processing Time 0.025 seconds

Study of Product Sizes Currently Used by Manufacturers, for the Purpose of Designing Figure Skating Wear for children (아동용 피겨 스케이트복 설계를 위한 업체 사이즈 조사연구)

  • Park, Sang-Hee
    • Journal of the Korean Society of Costume
    • /
    • v.60 no.1
    • /
    • pp.1-13
    • /
    • 2010
  • Recently population of figure skating is growing fast, so that the needs for girls figure skating wear of better quality and better fit is growing too. As the characteristics of figure skating require both strong stretching and grace movements, the skating wears should be designed to have sufficient extensibility and impressive effects through body movements. In order that the figure skating wear should be fit well by using right sizing systems. The purpose of this study is to find out how the figure skating wear specialists are using their sizing system. There were two separate comparative studies in this article. One is to compare girls' sizing system between countries such as USA, UK, Japan and Korea. This is to look into the characteristics of girls body measurements than adults or other ages. The other is to compare sizing systems of 88 figure skating wear specialists from 8 countries. As a results, it is suggested that there should be a practical sizing systems for figure skating wear, which uses common size code, measurements definition and size interval.

A Study on the Suitability of Sifting System for Children′s Clothing - focused on the Tween Generation from fifth grade to eighth grade - (트윈세대(Tween Generation) 아동복의 치수적합성에 관한 연구 -초등학교 5, 6학년, 중학교 1, 2학녕을 중심으로-)

  • 김은경;최혜선;강여선
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.26 no.5
    • /
    • pp.691-702
    • /
    • 2002
  • The purpose of this study was to provide basic information on the propriety of the ready to wear garment sizes of Tween Generation(ages from 5th grade to 8th grade) who has different clothing preferences in color, styles, and design and also different body sizes and shapes from younger and older students. The objectives of the study were to ascertain (a) the body figure changes occurring during Tween Generation; (b) the coverage of manufactures'garment sizes. The body measurements of elementary school students(5th & 6th grades) and junior high school students(7th & 8th grades) provide the basic statistics for this study. The mean differences of each size within each figure type are compared by using t-teats. The differences in various manufacturers'apparel sizing and figure size are investigated. Also the body measurements and the apparel sizes of the manufacturers are compared in order to evaluate the suitability of the garment size. Results indicate that the body type factors are different in each age group. And manufactures'sizes come out to be much smaller than the actual body measurements. Young casual wear can cover junior high school students satisfactorily but for elementary school students, because of low drop-value, the overall satisfaction with filling is low.

Design and Implementation of an Absolute Position Sensor Based on Laser Speckle with Reduced Database

  • Tak, Yoon-Oh;Bandoy, Joseph Vermont B.;Eom, Joo Beom;Kwon, Hyuk-Sang
    • Current Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.362-369
    • /
    • 2021
  • Absolute position sensors are widely used in machine tools and precision measuring instruments because measurement errors are not accumulated, and position measurements can be performed without initialization. The laser speckle-based absolute position sensor, in particular, has advantages in terms of simple system configuration and high measurement accuracy. Unlike traditional absolute position sensors, it does not require an expensive physical length scale; instead, it uses a laser speckle image database to measure a moving surface position. However, there is a problem that a huge database is required to store information in all positions on the surface. Conversely, reducing the size of the database also decreases the accuracy of position measurements. Therefore, in this paper, we propose a new method to measure the surface position with high precision while reducing the size of the database. We use image stitching and approximation methods to reduce database size and speed up measurements. The absolute position error of the proposed method was about 0.27 ± 0.18 ㎛, and the average measurement time was 25 ms.

In vivo assessment of accuracy of Propex II, Root ZX II, and radiographic measurements for location of the major foramen

  • Tampelini, Fernanda Garcia;Coelho, Marcelo Santos;de Azevedo Rios, Marcos;Fontana, Carlos Eduardo;Rocha, Daniel Guimaraes Pedro;Pinheiro, Sergio Luiz;da Silveira Bueno, Carlos Eduardo
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.3
    • /
    • pp.200-205
    • /
    • 2017
  • Objectives: The aim of this in vivo study was to assess the accuracy of 2 third-generation electronic apex locators (EALs), Propex II (Dentsply Maillefer) and Root ZX II (J. Morita), and radiographic technique for locating the major foramen (MF). Materials and Methods: Thirty-two premolars with single canals that required extraction were included. Following anesthesia, access, and initial canal preparation with size 10 and 15 K-flex files and SX and S1 rotary ProTaper files, the canals were irrigated with 2.5% sodium hypochlorite. The length of the root canal was verified 3 times for each tooth using the 2 apex locators and once using the radiographic technique. Teeth were extracted and the actual WL was determined using size 15 K-files under a ${\times}25$ magnification. The Biostat 4.0 program (AnalystSoft Inc.) was used for comparing the direct measurements with those obtained using radiographic technique and the apex locators. Pearson's correlation analysis and analysis of variance (ANOVA) were used for statistical analyses. Results: The measurements obtained using the visual method exhibited the strongest correlation with Root ZX II (r = 0.94), followed by Propex II (r = 0.90) and Ingle's technique (r = 0.81; p < 0.001). Descriptive statistics using ANOVA (Tukey's post hoc test) revealed significant differences between the radiographic measurements and both EALs measurements (p < 0.05). Conclusions: Both EALs presented similar accuracy that was higher than that of the radiographic measurements obtained with Ingle's technique. Our results suggest that the use of these EALs for MF location is more accurate than the use of radiographic measurements.

Characteristics of Adult Women's Body Somatotype according to Drop Values (성인 여성의 드롭 치수에 따른 체형 특성 연구)

  • Yoon, Ji-Won;Suh, Mi-A
    • The Research Journal of the Costume Culture
    • /
    • v.20 no.4
    • /
    • pp.529-534
    • /
    • 2012
  • An analysis of adult women's somatotypes classified by drop values can provide important preliminary data in determining standard clothing sizes for mass production of ready-made clothes. This is because the values are based on measurements of girth, which is essential information in the size-setting process. Adult women's body types are classified according to drop values in a standard clothing size system adopted by Korea and several other countries. This study aims to identify somatotype characteristics of adult women aged 20 to 69 by using five types of drop values: bust-waist, hip-waist, hip-bust, abdomen-waist, and hip-abdomen. Statistical cluster analysis of collected data revealed four somatotypes among adult women. Type R, with a developed lower body, accounted for 36.6%, and its bodyline was found to be closest to the average adult woman. Type X, constituting 25.4%, had the curviest contours of all and relatively large hip measurements, with the thinnest figure. Flat abdomen and hips characterized type Y, which accounted for 18.9%. Lastly, 19.0% fell into type H, the most obese figure, in which abdomen girth exceeded hip measurements. Since type H has excess fat deposits in the abdomen, not only hip measurements but also abdomen girth should be considered when designing top longer than torso-length and bottoms.

A Korean-American Comparative Study of 3D Scanned Female Anthropometric Data

  • Yi, Kyonghwa;Cynthia, L. Istook
    • Journal of Fashion Business
    • /
    • v.17 no.3
    • /
    • pp.74-84
    • /
    • 2013
  • The purpose of this research is to provide useable data for application in American and Korean apparel company. This data was developed by analyzing information of Korean and American body sizes obtained from "Size USA Project" and "Size Korea Project". The Subjects were 6,306 American females and 1,988 Korean females over 18 years old. 30 measurements and 14 computed values were chosen that were considered critical in making garments. And descriptive analysis, percentile analysis and t-test were used as statistical methods for analyzing measurements and computed value between the two countries. The results were as follows. It was determined that American women were larger and bigger than Korean women in all measurements and computed values, except for Shoulder Slope. Based on BMI values, we determined that American women had a distinct tendency towards being overweight. Through the comparison of drop values (i.e. the difference between Hip and Bust Girths or Hip and Waist Girths), ratio values (i.e. waist height divided by height) and Body Mass Index (BMI) between the two countries, we determined that American women's figures were shapelier than Korean women's. American women had higher hip heights and longer leg lengths for their height compared to Korean woman. Furthermore, the back shapes of Korean women were flatter than American women and BMI values indicated American women were relatively more overweight than Korean women.

Imperfect Competition and Productivity: Korean Fossil-fueled Power Generation Sector (발전부문의 불완전경쟁과 생산성 변화)

  • Kwon, Oh-Sang;Park, Hojeong
    • Environmental and Resource Economics Review
    • /
    • v.19 no.1
    • /
    • pp.3-21
    • /
    • 2010
  • By the significant structural change in 1999, a partial privatization has occurred in Korean fossil-fuel power generation sector. Under the current price scheme wholesale electricity price is dependent on output size, and hence, may not satisfy the assumption of price-taking producers. The purpose of our study is constructing the productivity change measurements of Korean power generation sector taking into account possibly imperfect competition and variable returns to scale. Our approach based on Harrison (1994) and Levinsohn (1993) derives the plant-level productivity measurements of the period between 2001 and 2007, as well as the measurements of mark-ups and returns to scale. It is shown that the mark-up size is dependent on the plants' fuel type and is decreasing over time. Allowing for imperfect competition and variable returns to scale adjusts the productivity measurements substantially.

  • PDF

Development of Standard Body Measurement for Elderly Women -Characteristics & Regional Difference of Body Dimensions- (노년 여성의 표준치수 설정에 관한 연구(I) -연령대별 체형특성 및 지역별 체형차-)

  • 이정임;주소령;남윤자;문지연
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.27 no.1
    • /
    • pp.88-99
    • /
    • 2003
  • The body changes of the elderly women are the forward tilt of the neck and shoulder point shrinkage of the spinal column, and protrusive abdomen. Unfortunately, few data based on body measurements for elderly women existed and a few studies are limited to the body figure of the elderly women. If these changes are not applied to the manufacturing of the clothing, almost of the elderly women will be unfitted with their clothing. So to improve the fitting of the elderly women, it is necessary to use the standard size systems for elderly women. This report is the first study to develop the standard tables of body measurements to be used for improving the fit of garments and patterns for women aged 60 and older. This study drew from anthropometric measurements of 337 and photographic measurements of 276 women aged 60 and older. It described the protocol of anthropometric measurement, the comparison between the measured data and the data on which National anthropometric survey of Korea 1997 is based, and the development of body measurement standard tables for elderly women. And we also considered the regional difference of body dimensions in order to develop the national size standards for elderly women. Further study would include the classification of body dimensions and description of each figure type for sizing apparel of women aged 60 and older.

Size Measurements of Droplets Entrained in a Stagnant Bubbling Liquid Column

  • Jeong, Hae-Yong;No, Hee-Cheon;Song, Chul-Hwa;Chung, Moon-Ki
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11a
    • /
    • pp.254-259
    • /
    • 1996
  • Phase Doppler particle analyze. (PDPA) is a instrument which can be used to obtain simultaneous size and velocity measurements in a multiphase flow. In this study, the size of the water droplets entrained from a bubbling surface of a stagnant liquid column is measured by PDPA with a specially designed transmitter of long focal length and large beam diameter. The test section tube is made of acryle with 18 mm I.D. and 900 mm length. The experimental data are obtained for the air superficial velocity between 0.7 m/s to 3.4 m/s at atmospheric pressure. The experimental results show that there exists large difference in the entrainment mechanism between the churn-turbulent flow and annular flow. Through the present study, the phase Doppler analyzer system is shown to be successfully applied to measure particle sizes larger than $2,000\mu\textrm{m}$ if a transmitter of long focal length is utilized.

  • PDF

An experimental study on the atomizing characteristics of liquid column type coaxial sprays (액주형 동축노즐 분무의 무화특성에 관한 실험적 연구)

  • 노병준;강신재;오제하
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.14 no.5
    • /
    • pp.41-53
    • /
    • 1992
  • The main purpose of this study is to investigate the atomizing characteristics of a two phase spray by using a liquid column type coaxial nozzle. The experiments have been carried out to analyze the atomization behavior, the droplet size distributions, and the statistical properties of droplet size distributions. Immersion sampling method and the image processing technique were adapted for the measurements of particles, and the distributions of the droplet sizes were statistically analyzed. In the experiments, the mass ratio defined as Mr= $M_{\sigma}$/ $M_{1}$ has been changed from 1.0 to 3.4 and the measurements have been performed along the axis of the spray. As a result of this experimental study, the distributions of droplet size were satisfied with the Log-Normal distributions and arithmetic mean diameter and deviation of mass ratio. Droplet volume-surface mean diameter was denoted by a exponential function of mass-ratio and the exponent was denoted by linear relation according to the central axis from the nozzle. Dispersions, skewness factors and flatness factors had comparatively constant values regardless of mass ratio and location.

  • PDF