• 제목/요약/키워드: Size distribution measurement

검색결과 516건 처리시간 0.025초

실내외 압력 차에 따른 단창과 이중창의 틈새로 침투된 간접흡연의 입자 크기 분포 특성 (Characterization of Particle Size Distribution of Infiltrated Secondhand Smoke through the Gap in a Single Glazed and a Secondary Glazed Window by Indoor and Outdoor Pressure Differences)

  • 김정훈;이기영
    • 한국환경보건학회지
    • /
    • 제44권4호
    • /
    • pp.360-369
    • /
    • 2018
  • Objectives: Outdoor tobacco smoke can penetrate into the indoor environment through cracks in the building envelope. This study aimed to characterize the particle size distribution of infiltrated secondhand smoke (SHS) through the gap in a single glazed and a secondary glazed window according to pressure differences in a chamber. Methods: Two polyvinyl chloride sliding windows were evaluated for infiltration, one with a glazed window and the other with a secondary glazed window. Each window was mounted and sealed in a polycarbonate chamber. The air in the chamber was discharged to the outside to establish pressure differences in the chamber (${\Delta}P$). Outdoor smoking sources were simulated at a one-meter distance from the window side of the chamber. The particle size distribution of the infiltrated SHS was measured in the chamber using a portable aerosol spectrometer. The particle size distribution of SHS inside the chamber was normalized by the outdoor peak for fine particles. Results: The particle size distribution of SHS inside the chamber was similar regardless of window type and ${\Delta}P$. It peaked at $0.2-0.3{\mu}m$. Increases in particulate matter (PM) concentrations from SHS infiltration were higher with the glazed window than with the secondary glazed window. PM concentrations of less than $1{\mu}m$ increased as ${\Delta}P$ was increased inside the chamber. Conclusions: The majority of infiltrated SHS particles through window gap was $0.2-0.3{\mu}m$ in size. Outdoor SHS particles infiltrated more with a glazed window than with a secondary glazed window. Particle sizes of less than $1{\mu}m$ were associated with ${\Delta}P$. These findings can be a reference for further research on the measurement of infiltrated SHS in buildings.

에어로졸 중화기의 성능이 고하전 입자의 크기분포 측정에 미치는 영향 (Effect of Performance of Aerosol Charge Neutralizers on the Measurement of Highly Charged Particles Using a SMPS)

  • 지준호;배귀남;황정호
    • 대한기계학회논문집B
    • /
    • 제27권10호
    • /
    • pp.1498-1507
    • /
    • 2003
  • A SMPS(scanning mobility particle sizer) system measures the number size distribution of particles using electrical mobility detection technique. An aerosol charge neutralizer, which is a component of the SMPS, is a bipolar charger using a radioactive source to apply an equilibrium charge distribution to aerosols of unknown charge distribution. However, the performance of aerosol charge neutralizers is not well known, especially for highly charged particles. In this study, the effect of the particle charging characteristics of two aerosol charge neutralizers on the measurement using a SMPS system was experimentally investigated for highly charged polydisperse particles. One has radioactive source of $^{85}$ Kr (beta source, 2 mCi) and the other has $^{210}$ Po (alpha source, 0.5 mCi). The air flow rate passing through each aerosol charge neutralizer was changed from 0.3 to 3.0 L/min. The results show that the non-equilibrium character in particle charge distribution appears as the air flow rate increases although the particle number concentration is relatively low in the range of 1.5∼2x10$^{6}$ particles/㎤. The low neutralizing efficiency of the $^{85}$ Kr aerosol charge neutralizer for highly charged particles can cause to bring an artifact in the measurement using a SMPS system. However, the performance of the $^{210}$ Po aerosol charge neutralizer is insensitive to the air flow rate.

공기운반분무기용 세라믹 노즐의 미립화 성능 (The Atomization Performance of Ceramic Nozzles in Air Carrier Sprayer)

  • 박석호;노수영
    • Journal of Biosystems Engineering
    • /
    • 제20권3호
    • /
    • pp.236-244
    • /
    • 1995
  • Droplet size is one of the important factors in the deposition and drift of agrichemical application. In this study, droplet size and its distribution of the three different sizes of ceramic hollow cone nozzles being used in the air carrier sprayer for apple production were investigated at the various nozzle pressures and the three air velocities. The Malvern particle size analyzer were used for the measurement of droplet size and its distribution. The important results emerged from th is study can be summarized as follows. 1. Discharged rate was increase with the increase of the nozzle diameter and pressure, amount of the difference was remarkable between the nozzle diameter of 1.0, 1.2 and 1.5 mm, but no difference were found between the diameter of 1.0 and 1.2 mm in the same nozzle pressure. 2. Mass median diameter were varied as 40~160 ${mu}m$ at the air velocity of 0 m/s, 70~140 ${mu}m$ of 15 m/s and 100~160 ${mu}m$ of 20 m/s 3. It appeared that the air velocity range of 15~20 m/s was desirable for both drift and deposition control in the given experimental conditions.

  • PDF

신사복 상의 설계를 위한 체형의 호칭 분류와 사이즈 스팩;36세에서 43세 우리나라 남성을 대상으로 (Designation of Bodytypes and Size Specifications for Designing of the Ready-made Jacket)

  • 김구자
    • 한국의류학회지
    • /
    • 제23권8호
    • /
    • pp.1240-1247
    • /
    • 1999
  • The purpose of this study was to classify size specifications of Korean adult male for the men's ready-made garments especially jacket and dress shirts By the stratified sampling method data were collected by the real anthropometric measurement. Sample size was 263 subjects as the sample and their age range was from 36 to 43 years old 66 variables from the direct anthropometric data were applied to analyze. ANOVA is SPSSWIN 8.0 package was applied to the data and the expected frequency distribution of 10.000 men was calculated by the extraction of density function. This study was performed to classify size specificatios by the control dimensions. The drop values of 9,12 and 6 have the high coverage rate of 28.52% 23.44% respectively Obese body type ; H type HD type and HE type are composed of the majority of 55.47% of the subjects. According to the drop values size specifications and distribution of control dimensions are predicted About 69.82% of the expected frequency distribution were covered by 19 size specifications.

  • PDF

기성복 제작을 위한 성인 남성의 사이즈 스팩의 분류 (Size Specifications of Korean Adult Male for the Ready-made Garments)

  • 김구자;이순원
    • 한국의류학회지
    • /
    • 제21권7호
    • /
    • pp.1247-1257
    • /
    • 1997
  • The purpose of this study was to classify size specifications of Korean adult male for the men's ready·made garments, especially jacket and dress shirts. Concept of the comfort and fitness has become a major concern in the basic function of the ready-made garments. Data were collected by the real anthropometric measurement and by the photographic sources. Sample size was 1.290 subjects as the sample and their age range was from 19 to 54 pean old by the stratified sampling method. 66 variables from the direct anthropometric data in total were applied to analyze. ANOVA in SAS package was applied to the data and the expected frequency distribution of 10.000 men was calculated by the extraction of density function. Control dimensions for jacket and dress shirts has been designated by Bcorean Apparel Sizing System (KS-K). Therefore this study was performed to classify size specifications by the control dimensions and at the same interval of KS-K. The drop values of 15, 12 and 9 has the high coverage rate of 22.1%, 21.0% and 18.8% respectively and are composed of the majority of 61.9% of the subjects. According to the drop values, size specifications and distribution of control and reference dimensions are predicted. About 65.75% of the expected frequency distribution without stature were covered by 19 size specification.

  • PDF

유한요소법을 이용한 2차원 Field 내의 온도분포의 이론적 해석 (THEORITICALL ANALYSIS OF TEMPERATURE DISTRIBUTION IN TWO-DIMENSIONAL FIELD USING F.E.M)

  • 김낙환;최창순;최홍호;홍승홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(II)
    • /
    • pp.1292-1295
    • /
    • 1987
  • In noninvasive temperature measurement within body, this paper is presented temperature measurement method in security and with effect from Applicator by electromagnetic, and it is analyzed heat generation quantity or temperature rise distribution by computer simulation within body. In this paper, two-dimensional model is considered and temperature distribution produced by RF capacitive heating system is analyzed by using Finit Element Method (F.E.M). A passibility of temperature distribution control is examined based on the position and size of Applicator.

  • PDF

CMP 공정에서 발생하는 연마온도 분포에 관한 연구 (A Study on the Distribution of Friction Heat generated by CMP Process)

  • 김형재;권대희;정해도;이용숙;신영재
    • 한국정밀공학회지
    • /
    • 제20권3호
    • /
    • pp.42-49
    • /
    • 2003
  • In this paper, we provide the results of polishing temperature distribution by way of infrared ray measurement system as well as polishing resistance, which can be interpreted as tribological aspects of CMP, using force measurement system. The results include the trend of polishing temperature, its distribution profile and temperature change during polishing. The results indicate that temperature affects greatly to the removal rate. Polishing temperature increases gradually and reaches steady state temperature and the period of temperature change occurs first tens of seconds. Furthermore, the friction force also varies as the same pattern with polishing temperature from high friction to low. These results suggest that the first period of the whole polishing time greatly affects the nonuniformity of removal rate.

수영모 맞음새 개선을 위한 한국인의 두형분석과 치수분포에 관한 연구 (A Study on the Analysis of Korean Adults' Bead-type and the Distribution of Size for Improving the Fitness of Swimming Headgear)

  • 김인숙;권명숙;양민재
    • 한국의류학회지
    • /
    • 제29권8호
    • /
    • pp.1079-1091
    • /
    • 2005
  • The purpose of this study was to point out the unification of the size of swimming headgear by measuring detailed measurement of head ferm and systematizes the head form. A total of 300 male and female Korean adults aged from 18 years old to 35 years old were measured through the direct measurement method. This study attempted to identify the head form of male and female adults using measurement data and the head form was classified through factor analysis and cluster analysis. (1) Based on the fact that this study especially focuses on the size of swimming headgear, factor analysis was performed far both direct measurements with hair and without hair. For the measurements with hair, seven factors were extracted. They were head thickness factor, head width factor, width of side head factor, height of back head factor, length of front head factor, circumference of front head factor, thickness of front head factor and head height factor. They explained the $70.95\%$ of the measurements. (2) The cluster analysis was executed to classify the somatotype of the korean head form on the basis of similarity. According to the cluster analysis result, the measurements with hair categorized types, 'Woman's long-hair type', 'Small type', 'Long and flat type', 'Large type'. (3) Head circumference B and Left tragion - Vertex - Right tragion circumference which are generally length and width in choosing swimming headgear size were selected as measurement items far size of swimming headgear. Direct measurements and sizes of four swimming headgear with different materials taking into account their elongation rate were also compared.

Statistical Analysis of End-to-End Delay for VoIP Service in Mobile WiMAX Networks

  • Islam, Mohd. Noor;Jang, Yeong-Min
    • 한국통신학회논문지
    • /
    • 제35권2A호
    • /
    • pp.196-201
    • /
    • 2010
  • Measurement of Quality of Service (QoS) parameters and its statistical analysis becomes a key issue for Mobile WiMAX service providers to manage the converged network efficiently and to support end-to-end QoS. In this paper, we investigate the population distribution of end-to-end one-way delay which is the most important QoS parameter in Mobile WiMAX networks. The samples are analyzed with Chi-Square Goodness-of-Fit test, Kolmogorov-Smirnov (K-S), and Anderson-Darling (A-D) test to verify the distribution of parent population. The relation with confidence level and the minimum number of sample size is also performed for logistic distribution. The statistical analysis is a promising approach for measuring the performance Mobile WiMAX networks.

[Retraction]Size measurement and characterization of ceria nanoparticles using asymmetrical flow field-flow fractionation (AsFlFFF)

  • Kim, Kihyun;Choi, Seong-Ho;Lee, Seungho;Kim, Woonjung
    • 분석과학
    • /
    • 제32권5호
    • /
    • pp.173-184
    • /
    • 2019
  • As the size of semiconductors becomes smaller, it is necessary to perform high precision polishing of nanoscale. Ceria, which is generally used as an abrasive, is widely used because of its uniform quality, but its stability is not high because it has a high molecular weight and causes agglomeration and rapid precipitation. Such agglomeration and precipitation causes scratches in the polishing process. Therefore, it is important to accurately analyze the size distribution of ceria particles. In this study, a study was conducted to select dispersants useful for preventing coagulation and sedimentation of ceria. First, a dispersant was synthesized and a ceria slurry was prepared. The defoamer selection experiment was performed in order to remove the air bubbles which may occur in the production of ceria slurry. Dynamic light scattering (DLS) and asymmetrical flow field-flow fractionation (AsFlFFF) were used to determine the size distribution of ceria particles in the slurry. AsFlFFF is a technique for separating nanoparticles based on sequential elution of samples as in chromatography, and is a useful technique for determining the particle size distribution of nanoparticle samples. AsFlFFF was able to confirm the presence of a little quantities of large particles in the vicinity of 300 nm, which DLS can not detect, besides the main distribution in the range of 60-80 nm. AsFlFFF showed better accuracy and precision than DLS for particle size analysis of a little quantities of large particles such as ceria slurry treated in this study.