• Title/Summary/Keyword: Size and Number Concentration

Search Result 481, Processing Time 0.023 seconds

Thermally Robust Highly Crosslinked Poly(methyl methacrylate-co-divinyl benzene) Microspheres by Precipitation Polymerization

  • Shim, Sang-Eun;Sunhye Yang;Hyejeon Jung;Soonja Choe
    • Macromolecular Research
    • /
    • v.12 no.2
    • /
    • pp.233-239
    • /
    • 2004
  • We prepared thermally robust fully crosslinked poly(methyl methacrylate-co-divinyl benzene) [poly(MMA-co-DVB)]microspheres successfully by precipitation polymerization in the absence of a stabilizing agent. The DVB concentration plays a pivotal role not only in the formation of the individually stable microspheres but also in the polymerization characteristics, including the particle size, the uniformity of size, the polymerization yield, and the thermal properties. The number-average diameter of the microspheres increased linearly, from 0.72 to 2.15 $\mu\textrm{m}$, and the particle size distribution became narrower, by elevating the uniformity from 1.35 to 1.12, as the DVB concentration increased from 20 to 75 mol%. In addition, the yield of the polymerization increased, from 73.4 to 98.6%, as the DVB concentration increased. Since the prepared particles possess fully crosslinked microstructures, no glass transition temperatures were observed, but all the samples prepared with DVB concentrations ranging from 20 to 75 mol% possess enhanced thermal properties. Based on the DSC and TGA data, the thermal stability of the mesospheres prepared by the precipitation polymerization is significantly improved as a result of crosslinking with DVB.

Deposition of Polydisperse Particles in a Falkner-Skan Wedge Flow (포크너-스캔 경계층유동에서의 다분산 입자부착에 대한 연구)

  • 조장호;황정호;최만수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.9
    • /
    • pp.2342-2352
    • /
    • 1995
  • Deposition of flame-synthesized silica particles onto a target is utilized in optical fiber preform fabrication processes. The particles are convected and deposited onto the target. Falkner-Skan wedge flow was chosen as the particle laden flow. Typically the particles are polydisperse in size and follow a lognormal size distribution. Brownian diffusion, thermophoresis, and coagulation of the particles were considered and effects of these phenomena on particle deposition were studied. A moment model was developed in order to predict the particle number density and the particle size distribution simultaneously. Particle deposition with various wedge configurations was examined for conditions selected for a typical VAD process. When coagulation was considered, mean particle size and its standard deviation increased and particle number density decreased, compared to the case without coagulation. These results proved the fact that coagulation effect expands particle size distribution. The results were discussed with characteristics of thermal and diffusion boundary layers. As the boundary layers grow in thickness, overall temperature and concentration gradients decrease, resulting in decrease of deposition rate and increase of particle residence time in the flow and thus coagulation effect.

Water Repellent Coating of Carbon Cloth with Different Size PTFE and Gas Permeabilities (PTFE 크기 변화에 따른 Carbon Cloth 발수 코팅과 가스 투과도 변화)

  • Jeon, Hyeon;Cho, Tae-Hwan;Choi, Weon-Kyung
    • Journal of Hydrogen and New Energy
    • /
    • v.21 no.4
    • /
    • pp.313-320
    • /
    • 2010
  • Carbon cloth was impregnated into PTFE emulsion. PTFE is a fluoropolymer used as a coating material in various fields due to its hydrophobicity and excellent mechanical properties. In this study, PTFE emulsion was prepared different particle size of 5~500 nm and $3{\sim}5{\mu}m$. FE-SEM and FT-IR spectroscopy were used microscopic observation and investigation of chemical structure change after PTFE coating. Mass variations, gas permeability and water contact angles were analyzed to determine a GDL performance of PTFE coated carbon cloth. PTFE coated carbon cloth show different mass increase according as PTFE concentration and the number of coating times. Water contact angle of PTFE coated carbon cloth was not effected by size of PTFE particle and the number of coating time; meanwhile, gas permeability was rapidly changed at carbon cloth coated by emulsion with size of $3{\sim}5{\mu}m$ PTFE particle.

Features on the Vertical Size Distribution of Aerosols using Ballon-borne Optical Particle Counter at Anmyeon (광학입자계수기를 이용한 안면도 연직 에어러솔 수농도 크기 분포 특성)

  • Choi, B.C.;Iwasaka, Y.;Lim, J.C.;Jeong, S.B.;Kim, Y.S.;Dmitri, T.;Nagatani, T.;Yamada, M.;Kim, S.B.;Hong, G.M.;Lee, Y.G.;Yoo, H.J.
    • Atmosphere
    • /
    • v.15 no.3
    • /
    • pp.149-153
    • /
    • 2005
  • A balloon-borne Optical Particle Counter (hereafter "OPC Sonde"), which was developed by the atmospheric research group of Nagoya University, is used for getting the information of vertical profile of particle size and concentration in Anmyeon ($36^{\circ}32^{\prime}N$ $126^{\circ}19^{\prime}E$) on 18 March 2005. A range of five different particle sizes is shown in the vertical profile of aerosol number density estimated from the OPC Sonde. It was found that small size particles have vertically larger aerosol number density than relatively big ones. For all size ranges the vertical aerosol number density shows a decreased pattern as the altitude becomes higher. The aerosol number density of $0.3{\sim}0.5{\mu}m$, $0.5{\sim}0.8{\mu}m$, $0.8{\sim}1.2{\mu}m$ size ranges at the 10km height, which is the tropopause approximately, are $1,000,000ea/m^3$, $100,000ea/m^3$, $10,000ea/m^3$ respectively. The data of OPC Sonde are also compared with the data of PM10 $\beta$-ray) and Micro Pulse Lidar which are operating at Korea Global Atmosphere Watch Observatory in Anmyeon.

Characteristics of long-range transported PM2.5 at a coastal city using the single particle aerosol mass spectrometry

  • Cai, Qiuliang;Tong, Lei;Zhang, Jingjing;Zheng, Jie;He, Mengmeng;Lin, Jiamei;Chen, Xiaoqiu;Xiao, Hang
    • Environmental Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.690-698
    • /
    • 2019
  • Air pollution has attracted ever-increasing attention because of its substantial influence on air quality and human health. To better understand the characteristics of long-range transported pollution, the single particle chemical composition and size were investigated by the single particle aerosol mass spectrometry in Fuzhou, China from 17th to 22nd January, 2016. The results showed that the haze was mainly caused by the transport of cold air mass under higher wind speed (10 m·s-1) from the Yangtze River Delta region to Fuzhou. The number concentration elevated from 1,000 to 4,500 #·h-1, and the composition of mobile source and secondary aerosol increased from 24.3% to 30.9% and from 16.0% to 22.5%, respectively. Then, the haze was eliminated by the clean air mass from the sea as indicated by a sharp decrease of particle number concentration from 4,500 to 1,000 #·h-1. The composition of secondary aerosol and mobile sources decreased from 29.3% to 23.5% and from 30.9% to 23.1%, respectively. The particles with the size ranging from 0.5 to 1.5 ㎛ were mainly in the accumulation mode. The stationary source, mobile source, and secondary aerosol contributed to over 70% of the potential sources. These results will help to understand the physical and chemical characteristics of long- range transported pollutants.

Development of Simple Bimodal Model for Charged Particle Coagulation (Bimodal 방법을 이용한 하전입자 응집 모델링)

  • Kim, Sang Bok;Song, Dong Keun;Hong, Won Seok;Shin, Wanho
    • Particle and aerosol research
    • /
    • v.10 no.1
    • /
    • pp.27-31
    • /
    • 2014
  • A simple bimodal model has been developed to analyze charged particle coagulation by modifying previously suggested bimdal model for evolution of particle generation and growth. In the present model, two monodisperse modes are used and 40 charge nodes are assigned to each mode to account both change of the particle size and charge distribution. In addition, we also implemented the effect of electrostatic dispersion loss in the present model. Based on the developed model, we analyzed coagulation of asymmetric bipolar charged particles by computing evolutions of particle number concentration, geometric mean diameter of particles, charge asymmetric ratio and geometric standard deviation of particle size distribution for various initial charge asymmetric ratios. The number concentration of asymmetric bipolar charged particles decreases faster than that of neutral particles but that does not give faster growth of particles since the electrostatic dispersion loss overwhelms particle growth by coagulation.

Condensation and coagulation of metallic species with fly ash particles in a waste incinerator (폐기물 소각시 생성되는 유해 중금속물질과 연소실내 비산재와의 응축, 응집 현상에 대한 연구)

  • Yu, Ju-Hyeon;Hwang, Jeong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.2
    • /
    • pp.264-274
    • /
    • 1997
  • A numerical analysis on condensation and coagulation of the metallic species with fly ash particles pre-existing in an incinerator was performed. Waste was simplified as a mixture of methane, chlorine, and small amounts of Pb and Sn. Vapor-phase amounts of Pb- and Sn -compounds were first calculated assuming a thermodynamic equilibrium state. Then theories on vapor-to-particle conversion, vapor condensation onto the fly ash particles, and particle-particle interaction were examined and incorporated into equations of aerosol dynamics and vapor continuity. It was assumed that the particles followed a log-normal size distribution and thus a moment model was developed in order to predict the particle concentration and the particle size distribution simultaneously. Distributions of metallic vapor concentration (or vapor pressure) were also obtained. Temperature drop rate of combustion gas, fly ash concentration and its size were selected as parameters influencing the discharged amount of metallic species. In general, the coagulation between the newly formed metal particles and the fly ash particles was much greater than that between the metal particles themselves or between the fly ash particles themselves. It was also found that the amount of metallic species discharged into the atmosphere was increased due to coagulation. While most of PbO vapors produced from the combustion were eliminated due to combined effect of condensation and coagulation, the highly volatile species, PbCl$_{2}$ and SnCl$_{4}$ vapors tended to discharge into the atmosphere without experiencing either the condensation or the coagulation. For Sn vapors the tendency was between that of PbO vapors and that of PbCl$_{2}$ or SnCl$_{4}$. To restrain the discharged amount of hazardous metallic species, the coagulation should be restrained, the number concentration and the size of pre-existing fly ash particles should be increased, and the temperature drop rate of combustion gas should be kept low.

Preparation of ZnO Thin Film by Electrophoretic Deposition(EPD)

  • Jun, Byung-Sei
    • Journal of the Korean Ceramic Society
    • /
    • v.49 no.1
    • /
    • pp.78-83
    • /
    • 2012
  • The electrophoretic deposition(EPD) of ZnO nano-sized colloids is investigated by changing the colloid number concentration, applied force, and deposition time. The change of the colloid size in a suspension was examined by the different colloid number concentrations (N = $3.98{\times}10^{15}$, N = $3.98{\times}10^{14}$, and N = $3.98{\times}10^{13}$) with an increase of the deposition time and applied forces. Deposition behavior was investigated by changing the applied fields (from DC 5 V to 50 V) and the deposition time (5 min to 25 min). The surface microstructures of the as-deposited films were investigated by SEM. The dried films were sintered from $850^{\circ}C$ to $1,050^{\circ}C$ for 2 h and then the microstructures were also explored by SEM. The agglomeration rate was enhanced by increasing the colloid number concentration of colloids. Colloid number concentration in a suspension must be rapidly decreased at higher values of the electric field. ZnO nano-sized colloids had the highest zeta potential value of over -28 mV in methanol. A homogeneous microstructure was obtained at colloid number concentration of N = $3.98{\times}10^{13}$, applied DC field of 5 V/cm and 15 min of deposition time at an electrode distance of 1.5 cm. Under these conditions, the deposited films were sintered at $850^{\circ}C$ and $1,050^{\circ}C$ for 2 h. The results show a typical pore-free surface morphology of a uniform thickness of 400 nm under these experimental conditions.

Influence of Aftertreatment System on the Size Distribution of Diesel Exhaust Particulate Matter (후처리 장치에 의한 디젤엔진 배출가스의 미세 입자 입경분포 변화)

  • 권순박;김민철;이규원;류정호;엄명도;김종춘;정일룩
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.7
    • /
    • pp.113-121
    • /
    • 1999
  • Diesel particulate matter is known to be one of the major harmful emissions produced by diesel engines. Diesel particulates are subject to diesel emission regulations and have lately become the focus in the diesel emission control technology. Thus, the aftertreatment system is adopted at the diesel engine exhaust to reduce the particulate emission. Although this benefit is recognized, it is not clear how the aftertreatment system influences quantitatively the particle size distribution distribution. In this study, the particle size distributions of diesel exhaust were measured using the scanning mobility particle sizer with and without the aftertreatment system. There results showed that the diesel particulate filter and plasm system reduced the number of emitted particles by more than 90% and about 80% respectivley in the particle size range of 20nm∼600nm. On the other hand no significant effect of the diesel oxidation catalyst on the particle number concentration was detected.

  • PDF

Vertical Aerosol Distribution and Flux Measurement in the Planetary Boundary Layer Using Drone (드론을 이용한 안면도 상공 대기경계층내의 미세먼지 연직분포 및 Flux 측정)

  • Kim, Heesang;Park, Yonghe;Kim, Wooyoung;Eun, Heeram;Ahn, Kang-Ho
    • Particle and aerosol research
    • /
    • v.14 no.2
    • /
    • pp.35-40
    • /
    • 2018
  • Vertical particle size distribution, total particle concentration, wind velocity, temperature and humidity measurement was performed with a drone. The drone was equipped with a wind sensor, house-made optical particle count(Hy-OPC), condensation particle counter(Hy-CPC), GPS, Temperature, Relative Humidity, Pressure and communication system. Base on the wind velocity and the particle size vertical distribution measurement with drone, the particle mass flux was calculated. The vertical particle distribution showed that the particle number concentration was very strongly correlated with the relative humidity.