A Study on the Reduction of the Sloshing of Storage Tank Using Wing and Diaphragm Baffle (날개형 및 격막형 배플을 이용한 유체저장탱크 내부의 슬로싱 저감 연구)

  • Lee, Young-Shin;Kim, Hyun-Soo;Lee, Jae-Hyung;Kim, Young-Wann;Ko, Sung-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.12
    • /
    • pp.2039-2046
    • /
    • 2003
  • Storage tank filled with fluid has unique dynamic characteristics compared to general structures, due to the interaction between fluid and structure. The oscillation of the fluid surface caused by external forces is called sloshing, which occurs in moving vehicles with contained liquid masses, such as trucks, railroad cars, aircrafts, and liquid missles. In this study, the evaluation method for the reduction of sloshing, the optimized size and location of wing and diaphragm baffles are suggested based on the experimental results. The experimental device can simulate the translation motion. A rectangular tank and various baffles are fabricated to study on the sloshing characteristics. The forces measured using the load cell at tank wall and those are compared with each other through the Fourier transformation for various conditions. The study of the sloshing of the rectangular tank equipped with baffles is conducted under the same conditions with non-baffled rectangular tank experiment. From the experimental results, the sloshing reduction effect by the baffles is observed. In conclusion in case of diaphragm baffles, the optimized size ratio of the width of baffle to the water height is 0.44 and the installation location has no effect to the damping of sloshing. In case of wing baffles, the optimized size ratio of the width of baffle to the length of a rectangular tank is 0.1 and the optimized location ratio of the baffle to the water height is 0.9.

Fabrication of Mechanical fatigue flawed Specimen and Evaluation of Flaw Size (기계적 피로결함 시험편 제조 및 결함 크기 평가)

  • Hong, Jae-Keun;Kim, Woo-Sung;Son, Young-Ho;Park, Ban-Uk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.1
    • /
    • pp.38-44
    • /
    • 2003
  • Performance demonstration with real flawed specimens has been strongly required for nondestructive evaluation of safety class components in nuclear power plant. Mechanical or thermal fatigue crack and intergranular stress corrosion cracking could be occured in the in-service nuclear power plant and mechanical fatigue crack was selected to study in this paper. Specimen was designed to produce mechanical fatigue flaw under tensile stress. The number of cycles and the level of stress were controlled to obtain the desired flaw roughness. After the accurate physical measurement of the flaw size and location, fracture surface was seal-welded in place to ensure the designed location and site. The remaining weld groove was then filled by using gas-tungsten are welding(GTAW) and flux-cored arc welding(FCAW). Results of radio graphic and ultrasonic testing showed that fatigue cracks were consistent with the designed size and location in the final specimens.

Development of the Home Location Register/Authentication Center in the CDMA Mobile System

  • Lim, Sun-Bae;Shin, Kyeong-Suk;Kim, Hyun-Gon
    • ETRI Journal
    • /
    • v.19 no.3
    • /
    • pp.186-201
    • /
    • 1997
  • In this paper, a home location register (HLR) for CDMA mobile communication system (CMS) is introduced. It stores the mobile station (MS) subscribers locations and supplementary service information. Call processing procedures for HLR are developed to receive and store subscriber's location coming from mobile exchange (MX) during the location registration, and to transfer subscriber's location and supplementary service information to the MX during the mobile-terminated call setup. For fast call processing by increasing database access speed, a memory-resident database management system is devised. For Easy and secure HLR operation, administration and maintenance functions and overload control mechanisms are implemented. Designed HLR hardware platform is expandable and flexible enough to reallocated software blocks to any subsystems within the platform. It is configurable according to the size of subscribers. An authentication center (AC) is developed on the same platform. It screens the qualified MS from the unqualified. The calls to and from the unqualified MS are rejected in CMS. To authenticate the MS, the AC generates a new authentication parameter called "AUTHR" using shared secret data (SSD) and compared it with the other AUTHR received from the MS. The MC also generates and stores seed keys called "A-keys" which are used to generate SSDs. The HLR requirements, the AC requirements, software architecture, hardware platform, and test results are discussed.

  • PDF

Study on the Utilization of Public Data for the Introduction of Solar Energy in Rural Areas (농촌지역 태양광에너지 도입을 위한 공공데이터 활용방안)

  • Kim, Sang-Bum;Kim, Yong-Gyun
    • Journal of Korean Society of Rural Planning
    • /
    • v.29 no.4
    • /
    • pp.175-182
    • /
    • 2023
  • The purpose of this study, the trend of renewable energy, domestic and foreign renewable energy policies, and the flow of the legal system related to renewable energy location were identified, and a location analysis using public data was studied when solar energy was located. First, renewable energy is leading to energy conversion by reducing the proportion of existing fossil fuel-centered energy sources in the global trend and increasing the proportion of renewable energy, an eco-friendly energy source, and changing the institutional and market structure. Second, large-scale solar energy power plants are installed and operated in rural areas where there is no change in insolation and land prices are cheaper than in urban areas where there are many changes in insolation due to surrounding high-rise buildings and street trees. Third, if a preliminary location review is conducted using public data at this time, it will be easy to identify the optimal location for area and size calculation. Fourth, the solar energy location functional area was studied in area A, and the total area of the target area was 624.5km2, with 392.7km2 and 62.9% of the avoidance area where solar power cannot be located.

Removal of Submandibular Stones via Intraoral approach (구강내 접근을 이용한 악하선 타석의 제거)

  • Lee, Sung-Bu;Lee, Jong-Cheol;Choi, Seung-Ho;Kim, Sang-Yoon;Nam, Soon-Yuhl
    • Korean Journal of Bronchoesophagology
    • /
    • v.14 no.1
    • /
    • pp.23-28
    • /
    • 2008
  • Background and Objectives : Traditionally, the excision of submandibular gland (SMG) has been commonly used for treatment of calculi in the proximal duct or gland parenchyma. Over the last 10 years several new minimally invasive techniques including lithotripsy, sialendoscope were introduced in the treatment of sialolithiasis. But these have some limitation on large, infected calculi. The aim of this study is to assess the intraoral treatment of submadibular stones. Subjects and Method : The records of one hundred and seventy-three patients who underwent intraoral removal of submadibular sialolithiasis between June 1, 1989 and July 31, 2006 were retrospectively reviewed. Results : Stone location was distal to the edge of the mylohyoid muscle in 127 patients and proximal to gland in 48 patients (mean size of sialoliths, 7.1mm [range 3.0-25mm]). The complete removal of stones was observed in 170 (97.1%) patients regardless of size and location. Recurrence of lithiasis was found in 8 patients (then treated with intraoral removal in 5 patientsand resection of SMG (submandibular glands) in 3 patients). Acalculous sialadenitis in 9 patients (5.1%) and cyst formation in 2 patients (1.1%) was found. But no evidence of postoperative complications including hemorrhage, fistula, damage to lingual nerve were found. Conclusion : The intraoral removal of submandibular stone is useful in preservation of submandiblar function and effective in palpable stones regardless of location, size.

  • PDF

Modeling Geologic Storage of Carbon Dioxide: Effects of Low-permeability Layer on Migration of CO2 (이산화탄소 지중저장 모델링: 저투수 이질협재층이 이산화탄소 거동에 미치는 영향)

  • Han, Ahreum;Kim, Taehee;Kwon, Yikyun;Koo, Min-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.22 no.3
    • /
    • pp.42-49
    • /
    • 2017
  • TOUGH2 was used to simulate the migration of $CO_2$ injected into a sandy aquifer. A series of numerical simulations was performed to investigate the effects of a low-permeability layer (LPL) embedded in the aquifer on the injection rate and the pressure distribution of $CO_2$. The results show that the size and location of the LPL greatly affected the spread of $CO_2$. The pressure difference between two points in the aquifer, one each below and above the LPL, increased as the size of the LPL increased, showing a critical value at 200 m, above which the size effect was diminished. The location of the LPL with respect to the injection well also affected the migration of $CO_2$. When the injection well was at the center of the LPL, the injection rate of $CO_2$ decreased by 5.0% compared to the case with no LPL. However, when the injection well was at the edge of the LPL, the injection rate was decreased by only 1.6%. The vertical distance between the injection point and the LPL also affected the injection rate. The closer the LPL was to the injection point, the lower the injection rate was, by up to 8.3%. Conclusively, in planning geologic storage of $CO_2$, the optimal location of the injection well should be determined considering the distribution of the LPL in the aquifer.

A study on location selection of total circulation complex using fuzzy theory (퍼지이론을 이용한 종합유통단지 입지 선정에 관한 연구)

  • Oh, Sun-Il;Yoon, Ho-Bin;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.1
    • /
    • pp.91-105
    • /
    • 2008
  • Nowadays, circulation industry is taking charge of important role in improvement of competitive power on the manufacturing industry and public welfare increase of consumer, price stabilization, employment creation and so on. A lot of research have been progressing for formation of total circulation complex, but decision making for selection of location on some facility is only calculated the optimum value when correct data values are inserted. However, a lot of decision making is accomplished in situation that have little knowledge of objective and constraints and as real world is also evaluated inclusive of analyst's subjectivity about variable, indefinite and fuzzy part, so it is decreasing a reliability on evaluation result and complicating objective evaluation on various effect and negative impact. Accordingly, from under like this situation, this study is to develop location decision model of circulation complex using fuzzy theory from the intention for the most reasonable decision making in fuzzy situation based on decision making problem on conventional location and size decision that did to be satisfactory constraints necessarily.

Adjusting Cluster Size for Alleviating Network Lifetime in Wireless Sensor Network (무선 센서네트워크에서 네트워크 수명 연장을 위한 클러스터 크기 조정 알고리즘)

  • Kwak, Tae-Kil;Jin, Kyo-Hong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.6
    • /
    • pp.1201-1206
    • /
    • 2007
  • In this paper, we propose an algorithm that improve network lifetime by adjusting cluster size according to location information of sensor node in wireless sensor network (WSN) using clustering algorithm. The collected sensing information by sensor nodes in each cluster are transferred to sink node using inter-cluster communications method. Cluster head (CH) that located nearby sink node spend much more energy than those of far from sink node, because nearer CH forwards more data, so network lifetime has a tendency to decrease. Proposed algorithm minimizes energy consumption in adjacent cluster to sink node by decreasing cluster size, and improve CH lifetime by distributing transmission paths. As a result of mathematical analysis, the proposed algorithm shows longer network lifetime in WSN.

Effect of Nozzle on LBB Evaluation for Small Diameter Nuclear Piping (직경이 작은 원자력배관의 파단전누설 해석에 미치는 노즐의 영향)

  • Yu, Yeong-Jun;Kim, Yeong-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.6
    • /
    • pp.1872-1881
    • /
    • 1996
  • LBB(Leak-Before-Break) analysis is performed for the highest stress location of each different type of mateerials in the nuclear piping line. In most cases, the highest stress occurs in the pipe and nozzle interface location. i.e. terminal end. The current finite element analysis approach utilizes the symmetry condition both for locations near the nozzle and for locationa away from the nozzle to minimize the size of the finite element model and to make analysis simple when calculating the J-integral values at the crack tip. In other words, the nozzle is not included in the finite element model. However, in reality, the symmetric condition is not applicable for the pipe-nozzle interface location. Because the pipe-nozzle interface location is asymmetric due to different stiffenss of the pipe and nozzle(both material and dimensions). The simplified analysis approach for pipe-nozzle interface locaiton is too conservative for a smaller diameter piping. In tlhis paper, various analyses are performed for the range of materials and crack sizes to evaluate the nozzle effect for a LBB anlaysis. This paper presents methodology for developing the piping evaluaiton diagram at the pipe-nozzle interface location.

Propose of New Ultrasonic Nondestructive Code Considering Discontinuity Position (불연속부의 위치를 고려한 초음파 비파괴 검사 규격의 개선안)

  • Jeong, Hwa-Young;Shin, Byoung-Chul;Jung, Beom-Seok;Lee, Chang-Moo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.3 no.4
    • /
    • pp.173-178
    • /
    • 1999
  • KS-code(KS B 0896) for nondestructive ultrasonic testing classifies the quality level by ratio of flaw size to plate thickness only. But stress distributions using verification(3 point bending test) show that location of the flaws is more important than the flaw size. So. KS-code should take the effect of flaw location for classifying the quality level of welded steel structures.

  • PDF