• Title/Summary/Keyword: Size

Search Result 65,970, Processing Time 0.069 seconds

Effect of Different Milling Methods on Distribution of Particle Size of Rice Flours (제분방법이 쌀가루의 입자크기에 미치는 영향)

  • Kum, Jun-Seok;Lee, Sang-Hyo;Lee, Hyun-Yu;Kim, Kil-Hwan;Kim, Young-In
    • Korean Journal of Food Science and Technology
    • /
    • v.25 no.5
    • /
    • pp.541-545
    • /
    • 1993
  • Two different methods (Sieve shaker, Elzone particle size analyzer) were used to investigate rice flour particle size obtained by various milling method. Results of Elzone particle size analyzer were more effective than Sieve shaker in determining particle size, and the distribution of particle size of rice flours was affected by the type of the milling methods used. A rice flour, prepared in a Pin mill had a particle size range of $60{\sim}500$ mesh, and 30.38% of the sample was in the particle size range $200{\sim}270$ mesh. A rice flour, prepared in a Colloid mill had a particle size range of $40{\sim}500$ mesh and more of flour particles appeared in the range $140{\sim}200$ mesh than any other particle size. A rice flour, prepared in a Micro mill had a particle size range of $140{\sim}500$ mesh, and 41.62% of the sample was in the particle size range over 500 mesh. A rife flour, prepared in a Jet mill had a finer flour particle size was over the particle size range 500 mesh. The finer rice flour gave the highest L value and the lowest a value. The wet-milled flour particles were observed as a cluster of starch granules and the particles of rice flour (dry-milling) were observed as fragment of rice grains. Scanning Electron Photomicrographs revealed that visual differences in structure between milling methods, and similar results with Elzone particle size analyzer method in particle size.

  • PDF

Blind Equalization Algorithm Using A Variable Step-Size (가변 Step-Size를 갖는 블라인드 등화 알고리즘)

  • Choi, Ik-Hyun;Kim, Chul-Min;Oh, Kil-Nam;Choi, Soo-Chul
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2005.11a
    • /
    • pp.317-320
    • /
    • 2005
  • 기존의 블라인드 등화(blind equalization) 알고리즘의 step-size는 임의의 값을 알고리즘에 적용하여 수렴속도와 정상 상태의 특성을 고려하여 최적한 step-size를 결정하였다. step-size를 크게 하면 수렴속도는 빠른 반면에 정상 상태에서 에러가 크고, step-size를 작게 하면 수렴속도는 느린 반면에 정상 상태에서 에러가 작아진다. 그렇기 때문에 수렴속도와 정상 상태를 고려해서 step-size를 결정해야 되고, 특별하게 정해지는 기준이 없기 때문에 연구자의 판단에 의해서 다르게 선택된다. 본 논문에서는 등화기 출력의 잔류 심벌간 간섭에 따라 step-size를 가변함으로서 수렴속도 및 정상 상태 성능을 개선한 가변 step-size를 갖는 블라인드 등화 알고리즘을 제안한다.

  • PDF

Brassiere sizing system applying loss function -Centering on elderly women- (손실함수를 이용한 브래지어 치수 규격 설정에 관한 연구)

  • 이경화;최혜선
    • Proceedings of the ESK Conference
    • /
    • 1995.10a
    • /
    • pp.268-279
    • /
    • 1995
  • The purpose of this study is to suggest a brassiere sizing chart for elderly women. It is found that there is no direct linear relationship between cup size and under bust girth from the analsis of breast measurements. These 2 factors(under bust girth and cup size) were chosen as 2 axes of brassiere size chart. A loss function was used to determined intervals of bust girth and cup size of size chart, because the loss function introduces the concept of frequency to size chart for better customer's satisfaction. From the dual distribution table whose intervals had been determinde by a loss function. The 15 sizes, which had more than 2% of appearance were suggested for brassiere size chart. The suggested brassierc sizes covened 87.6% of all subjects. Considering that KS brassiere size thart consisting of 32 sizes covers 88.5%, the suggested brassiere size chart would be considered quite feasible. Also is suggested supply reference measurement chart relevant to brassiere manufacturing for 10 most frequent sizes.

  • PDF

Hierarchical Identity-Based Encryption with Constant-Size Private Keys

  • Zhang, Leyou;Wu, Qing;Hu, Yupu
    • ETRI Journal
    • /
    • v.34 no.1
    • /
    • pp.142-145
    • /
    • 2012
  • The main challenge at present in constructing hierarchical identity-based encryption (HIBE) is to solve the trade-off between private-key size and ciphertext size. At least one private-key size or ciphertext size in the existing schemes must rely on the hierarchy depth. In this letter, a new hierarchical computing technique is introduced to HIBE. Unlike others, the proposed scheme, which consists of only two group elements, achieves constant-size private keys. In addition, the ciphertext consists of just three group elements, regardless of the hierarchy depth. To the best of our knowledge, it is the first efficient scheme where both ciphertexts and private keys achieve O(1)-size, which is the best trade-off between private-key size and ciphertext size at present. We also give the security proof in the selective-identity model.

Relationship between Organizational Size and Performance in Public Management : Mediating Effect of Organizational Goal Ambiguity

  • Lee, Soochang;Kim, Daechan
    • International Journal of Advanced Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.18-27
    • /
    • 2020
  • This study is to corroborate the relationship between organizational size and performance in the Korean government context. Hence, this study aims to advance research on the relationship between organization size and performance by considering mediating variable: organizational goal ambiguity, which helps understand how organizational size affects organizational goal ambiguity in government and the organizational goal ambiguity has an influence on organizational performance. Bases on theoretical review, we assume that there is the inverted U-shaped relationship between the number of employees and budget size and organizational performance. From the results of path analysis, it shows that organizational size in the Korean government has a negative correlation, "a linear relationship", with organizational performance. Budget size has mediating variables, but the number of employees not. We try to suggest implications on the relationship between organizational size and performance in terms of theoretical perspectives in the context of the Korean government.

A Study on the Static Target Accurate Size Estimation Algorithm with TTSE (정지 표적 정밀 크기 추정을 위한 TTSE 알고리즘 연구)

  • Jung, Yun Sik;Kim, Jin Hwan;Hong, Seok Jin
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.7
    • /
    • pp.530-535
    • /
    • 2016
  • In this paper, the TTSE (Target size and Triangulation-based target Size Estimator) algorithm is proposed to estimate static target size in an imaging environment. The target size information is an important factor for accurate imaging target tracking. However, the imaging sensor cannot generate distance between the missile and target to calculate the target size. To overcome the problem, we propose the TTSE algorithm, which is based on target size and triangulation. The proposed method performance is tested in a target intercept scenario. The experiment results show that the proposed algorithm has better performance than the conventional algorithm (ET-TSE) for accurate CCD target size estimation.

A Study on Size Standardization of Saengbwal Hanbok (생활 한복의 치수규격 표준화에 관한 연구)

  • Nam, Yun-Ja;Lee, Hyung-Suk;Lee, Jeong-Yim
    • Fashion & Textile Research Journal
    • /
    • v.3 no.2
    • /
    • pp.140-147
    • /
    • 2001
  • The purpose of this study is to suggest the standard size system of Saenghwal Hanbok for design development and popularization. As a sample, 20's and 40's female data among the 1997's National Somatometry Survey data were used because two groups have different somatic characteristics and design tastes with each other. The results are as follows; From t-test of 35 somatometric items in 20's and 40's female data, we knew that the differentiated size system proper to each age is needed. We also knew that the 38 Saenghwal Hanbok brands don't have consistent size system from investigation of size list and size application. From consideration on the number of size for production and coverage rate, we suggested regression formula by bust circumference and stature, and suggested advanced standard size system which are proper to each 20' and 40' female group.

  • PDF

JSize: A Java Equivalent of the UNIX size program (JSize: 유닉스의 size에 대응하는 자바 등가 프로그램)

  • 양희재
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.548-551
    • /
    • 2003
  • JSize is a Java equivalent of the Unix size program. The Unix size program analyses an executable file and estimates the size of code and data segment when the file is loaded on memory. Likewise, JSize analyze a Java class file and estimates the size of class area when the file is loaded on memory. This paper presents the principles necessary to estimate the class area size with the information obtained from a class file. An experimental result is included to show the accuracy of estimation the JSize provides.

  • PDF

A Suggestion of Sizing System for Clean Room Wear (무진복의 치수체계에 대한 연구)

  • 이경화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.7
    • /
    • pp.1044-1055
    • /
    • 2000
  • The purpose of this study is to suggest sizing chart for a clean room wear. 3 control dimensions(Stature, Bust girth, B.N.P.∼Wrist point length) were chosen as 3 axes of clean room wear size chart. A loss function was used to determined intervals of stature, Bust girth and B.N.P.∼Wrist point length of size chart, because the loss function introduces the concept of frequency to size chart for better customer's size satisfaction. From the size table whose intervals had been determined by a loss function. The 4 sizes individually were suggested for clean room wear size chart by sex. The 3 sizes individually were suggested for clean room head cover size chart by sex too. The suggested size chart would be considered more feasible than present size chart. Also they are suggested supply reference measurement chart relevant to clean room wear manufacturing for 13 most frequent sizes.

  • PDF

Preparation and Characterization of Microcapsule for non-aqueous dyeing (비수계 염색용 마이크로캡슐의 제조 및 성질)

  • 최창남;박원규;변수진;이기영
    • Textile Coloration and Finishing
    • /
    • v.15 no.5
    • /
    • pp.327-332
    • /
    • 2003
  • In this study, the polyurethane microcapsules for non-aqueous dyeing containing iron oxide and disperse dyes were prepared by in-situ polymerization method using hexamethylene diisocyanate(HDI) with ethylene glycol(EG). And the size, shape, and particle size distribution of microcapsules prepared were investigated. The size and shape of microcapsule were observed by optical microscope and scanning elecron microscope. The particle size distribution was analyzed by particle size analyzer. The microcapsule size and its distribution were largely effected by the existance of surface active agent in the system. When a surfactant did not exist in the system, the size distribution of microcapsules prepared was much uneven. By adding a surfactant, this phenomenon was disappeared. And the size of microcapsule was also effeced by the hydrophobicity of core material(disperse dye). It was considered due to the difference of dispersity of core materials. And the size of microcapsule prepared was inversely proportional to the stirring speed.