• Title/Summary/Keyword: Six Sigma method

Search Result 127, Processing Time 0.029 seconds

A Six Sigma Project for Reducing the Make pressure problem of Relay (릴레이 복귀전압 신뢰성 향상을 위한 6시그마 프로젝트 사례연구)

  • Kim Hyun Soo;Lee Hwa Ki;Kim Pan Joe
    • Journal of the Korea Safety Management & Science
    • /
    • v.7 no.1
    • /
    • pp.87-100
    • /
    • 2005
  • This paper studies on the quality problem for the Reley using the 6 sigma process. The application of 6 sigma process suggested reliable and valuable statistical data for the quality of the Relay at the production line. In the measurement step in 6 sigma process, the FMEA(filure mode effect analysis) were used for the detection of problem source. The application of 6 sigma process gave the improving method for the quality of the Relay. Consequently the 6 sigma process was proved very effective for the quality problem reducing at the production line.

A Study of Six Sigma and Total Error Allowable in Chematology Laboratory (6 시그마와 총 오차 허용범위의 개발에 대한 연구)

  • Chang, Sang-Wu;Kim, Nam-Yong;Choi, Ho-Sung;Kim, Yong-Whan;Chu, Kyung-Bok;Jung, Hae-Jin;Park, Byong-Ok
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.2
    • /
    • pp.65-70
    • /
    • 2005
  • Those specifications of the CLIA analytical tolerance limits are consistent with the performance goals in Six Sigma Quality Management. Six sigma analysis determines performance quality from bias and precision statistics. It also shows if the method meets the criteria for the six sigma performance. Performance standards calculates allowable total error from several different criteria. Six sigma means six standard deviations from the target value or mean value and about 3.4 failures per million opportunities for failure. Sigma Quality Level is an indicator of process centering and process variation total error allowable. Tolerance specification is replaced by a Total Error specification, which is a common form of a quality specification for a laboratory test. The CLIA criteria for acceptable performance in proficiency testing events are given in the form of an allowable total error, TEa. Thus there is a published list of TEa specifications for regulated analytes. In terms of TEa, Six Sigma Quality Management sets a precision goal of TEa/6 and an accuracy goal of 1.5 (TEa/6). This concept is based on the proficiency testing specification of target value +/-3s, TEa from reference intervals, biological variation, and peer group median mean surveys. We have found rules to calculate as a fraction of a reference interval and peer group median mean surveys. We studied to develop total error allowable from peer group survey results and CLIA 88 rules in US on 19 items TP, ALB, T.B, ALP, AST, ALT, CL, LD, K, Na, CRE, BUN, T.C, GLU, GGT, CA, phosphorus, UA, TG tests in chematology were follows. Sigma level versus TEa from peer group median mean CV of each item by group mean were assessed by process performance, fitting within six sigma tolerance limits were TP ($6.1{\delta}$/9.3%), ALB ($6.9{\delta}$/11.3%), T.B ($3.4{\delta}$/25.6%), ALP ($6.8{\delta}$/31.5%), AST ($4.5{\delta}$/16.8%), ALT ($1.6{\delta}$/19.3%), CL ($4.6{\delta}$/8.4%), LD ($11.5{\delta}$/20.07%), K ($2.5{\delta}$/0.39mmol/L), Na ($3.6{\delta}$/6.87mmol/L), CRE ($9.9{\delta}$/21.8%), BUN ($4.3{\delta}$/13.3%), UA ($5.9{\delta}$/11.5%), T.C ($2.2{\delta}$/10.7%), GLU ($4.8{\delta}$/10.2%), GGT ($7.5{\delta}$/27.3%), CA ($5.5{\delta}$/0.87mmol/L), IP ($8.5{\delta}$/13.17%), TG ($9.6{\delta}$/17.7%). Peer group survey median CV in Korean External Assessment greater than CLIA criteria were CL (8.45%/5%), BUN (13.3%/9%), CRE (21.8%/15%), T.B (25.6%/20%), and Na (6.87mmol/L/4mmol/L). Peer group survey median CV less than it were as TP (9.3%/10%), AST (16.8%/20%), ALT (19.3%/20%), K (0.39mmol/L/0.5mmol/L), UA (11.5%/17%), Ca (0.87mg/dL1mg/L), TG (17.7%/25%). TEa in 17 items were same one in 14 items with 82.35%. We found out the truth on increasing sigma level due to increased total error allowable, and were sure that the goal of setting total error allowable would affect the evaluation of sigma metrics in the process, if sustaining the same process.

  • PDF

A Case Study of Six Sigma Project for Improving method of measuring pulse wave (6시그마 기법을 통한 안정된 맥파측정 프로세스 설계)

  • Lee, Jeon;Lee, Yu-Jung;Lee, Hae-Jung;Choi, Eun-Ji;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.12 no.2 s.17
    • /
    • pp.85-92
    • /
    • 2006
  • Pulse is one of the basic diagnostic information of TKM(Traditional Korean Medicine). To quantify and standardize pulse diagnosis, we had collected an amount of clinical data from May 2005 by using newly developed pulse analyzer. But there were many noises in pulse wave according to measuring method, environment, operator and condition of patient. So some data can’t be included for analyzing diagnosis. To reduce noises from measuring pulse and to collect reliable pulse wave data, we made the process map of measuring method and applied six sigma project. With this we can improved the method of measuring pulse wave in collecting clinical data. The project follows a disciplined process of five macro phases: define, measure, analyze, improve and control (DMAIC). A process map and C-E diagram are used to identify process input and output variables. The major input variables are selected by using C&E matrix, and process map is developed by analyzing input variables. And the optimum process conditions are going to be controled to avoid in increasing loss of collecting pulse wave data.

  • PDF

Six Sigma based on Robust Design of Gripper for LCD Transfer System (LCD 이송장치의 그립퍼부 시그마 기반 강건설계)

  • Chung W.J.;Jung D.W.;Kim H.J.;Yoon Y.M.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.361-362
    • /
    • 2006
  • This paper presents the robust design of gripper part for a high-speed LCD (Liquid Crystal Display) transfer system. In this paper, the 1st DOE (Design of Experiment) is conducted to find out main-effect factors fur the design of gripper part. Thirty-six experiments are performed using $ANSYS^{(R)}$ and their results are statistically analyzed using $MINITAB^{(R)}$, which shows that the factors, i.e., First-width, Second-width, Rec-width, and thickness of gripper part, are more important than other factors. The main effect plots shows that the maximum deflection and mass of gripper part are minimized by increasing First-width, Second-width, Rec-width and thickness. The 2nd DOE is conducted to obtain RSM (Response Surface Method) equation. The CCD (Central Composite Design) technique with four factors is used. Optimum design is conducted using the RSM equation. Genetic algorithm is used for optimal design. Six sigma robust design is conducted to find out a guideline for control range of design parameter. To obtain six sigma level reliability, the standard deviations of design parameters are shown to be controlled within 5% of average design value.

  • PDF

Robust Design of Composite Structure under Combined Loading of Bending and Torsion (굽힘-비틀림 복합하중을 받는 복합재료 구조물의 최적 강건 설계)

  • Yun, Ji-Yong;O, Gwang-Hwan;Nam, Hyeon-Uk;Han, Gyeong-Seop
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.11a
    • /
    • pp.211-214
    • /
    • 2005
  • This research studied robust design of composite structure under combined loading of bending and torsion. DOE (Design of Experiment) technique was used to find important design factors. The results show that the beam height, beam width, layer thickness and stack angle of outer-layer are important design parameter. The $2^{nd}$ DOE and RSM (Response Surface Model) were conducted to obtain optimum design. Multi-island genetic algorithm was used to optimum design. An approximate value of 6.65 mm in deflection was expected under optimum condition. Six sigma robust design was conducted to find out guideline for control range of design parameter. To acquire six sigma level reliability, the sigma level reliability, the standard deviation of design parameter should be controlled within 2.5 % of average design value.

  • PDF

A Study on Dimension Optimization of Injection-molded Automotive Bumper by Six Sigma (6시그마를 이용한 자동차 범퍼의 치수 최적화에 대한 연구)

  • Kim, Joo-Kwon;Kim, Jong-Sun;Lee, Jun-Han;Kwak, Jae-Seob
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.6
    • /
    • pp.109-116
    • /
    • 2017
  • In this study, the optimization of the overall dimensions of an automobile bumper was investigated through CAE and experiment using the Six Sigma method and design of experiment (DOE) method, respectively. Injection pressure, injection speed, injection time, cooling time, holding time, injection temperature, and holding pressure were selected as the vital parameters affecting the overall width of product through analysis of trivial many using CAE. The optimal values were determined using the DOE method, and we analyzed the improvement by applying the optimal conditions to the production process. As a result, the mean value of the overall width was close to the target value, with a deviation of 0.05mm, and the processability and I-MR control were remarkably improved. Finally, the dimension pass rate of the product improved by 20%.

Six Sigma Robust Design for Railway Vehicle Suspension (철도차량 현수장치의 식스시그마 강건 설계)

  • Lee, Kwang-Ki;Park, Chan-Kyoung;Han, Seung-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.10
    • /
    • pp.1132-1138
    • /
    • 2009
  • The spring constants of primary suspensions for a railway vehicle are optimized by a robust design process, in which the response surface models(RSMs) of their dynamic responses are constructed via the design of experiment(DOE). The robust design process requires an intensive computation to evaluate exactly a probabilistic feasibility for the robustness of dynamic responses with their probabilistic variances for the railway vehicle. In order to overcome the computational process, the process capability index $C_{pk}$ is introduced which enables not only to show the mean value and the scattering of the product quality to a certain extent, but also to normalize the objective functions irrespective of various different dimensions. This robust design, consequently, becomes to optimize the $C_{pk}$ subjected to constraints, i.e. 2, satisfying six sigma. The proposed method shows not only an improvement of some $C_{pk}$ violating the constraints obtained by the conventional optimization, but also a significant decrease of the variance of the $C_{pk}$.

BPR Consulting applying New Customer Value Innovation Requirements Engineering Process (새로운 고객 가치혁신 요구공학 프로세스를 적용한 BPR 컨설팅)

  • Han, Kwang-Shin;Park, Man-Gon
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.6
    • /
    • pp.685-697
    • /
    • 2018
  • (Most companies that perform BPR have not achieved satisfactory results or have not performed successful BPRs. There are many reasons for this, but the most important one has caused problems that do not accurately reflect the requirements of various stakeholders. In this paper, we will apply the BPR consulting methodology to a new value innovation requirements engineering process based on the Blue Ocean strategy, which is a way to create a new market without competition by customerizing potential customers by satisfying new customer expectations and needs. This paper uses a requirements engineering process that can generate customer value by applying the ERRC(Erasure Reduce Raise Create) analysis method, which is the core of the Blue Ocean Strategy Framework[1,2]. We will also apply the Six Sigma DFSS (Design For Six Sigma) methodology to improve quality and process through quantitative and systematic analysis. The proposed approach was presented to the BPR consulting to present a practical case, and the results of the empirical analysis of the system user to validate the results of BPR consulting.

The Study of Influence Factor of Head Restraints on the Whiplash by using DFSS (DFSS 기법을 이용한 후방 추돌 시 경부 상해 감소를 위한 머리지지대 인자의 영향성 연구)

  • Oh, Hyungjoon;Seo, Sangjin;Yoo, Hyukjin
    • Journal of Auto-vehicle Safety Association
    • /
    • v.4 no.2
    • /
    • pp.5-10
    • /
    • 2012
  • Whiplash is the most frequent injury among occupants in low speed rear-end car collision. The aim of this paper is to analyze thecorrelation between influence parameters of head restraints and whiplash injury criteria.In this paper, DFSS (Design for Six Sigma) method is used for optimum design of head restrains. Four control factors of head restraints have selected by function matrix method. The effects of the control factors have been experimentally evaluated by using a sled pulse from 16km/h relative velocity which is suggested by KNCAP (Korean New Car Assessment Program). In order to reduce the noise factors of dynamic tests, whiplash tests were repeated twice. By using DFSS, the correlation between control factors and injury criteria has been comprehended.

A Case Study of Six Sigma Project for Improving Measurement Method of Skin Elasticity (피부탄성 측정 문제점 개선을 위한 6시그마 프로젝트)

  • Lee, Hae-Jung;Kang, Nam-Sik;Jeon, Young-Ju;Kim, Keun-Ho;Kim, Hong-Gie;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.16 no.3
    • /
    • pp.135-140
    • /
    • 2010
  • The usefulness of constitutional diagnoses based on skin measurements has been established in oriental medicine. According to Sasang constitutional medicine, humans can be distinguished based on properties of skin's friction, thickness and elasticity. To quantify and standardize skin diagnosis, the present study designed an equipment for measuring skin elasticity of hand. But there were some noises in measuring skin elasticity such as measurement method, environment, operator and conditions of patient. So we considered a six sigma project for reducing the measurement errors. The project was followed to discipline process of five macro phases: Define, Measure, Analyze, Improve and Control(DMAIC). So, we could find the major factors which should be controled for stabilizing measurement system and we revised the SOP(Standard Operating Procedure) of the skin elasticity measurement.