• Title/Summary/Keyword: Site plan

Search Result 1,492, Processing Time 0.024 seconds

Dressing Effect of Phosphorus Fetilizer on the Growth of Soil Improving Species (비료목생장(肥料木生長)에 미치는 인산비료(燐酸肥料)의 시비효과(施肥效果))

  • Ma, Sang Kyu
    • Journal of Korean Society of Forest Science
    • /
    • v.45 no.1
    • /
    • pp.26-36
    • /
    • 1979
  • Through several trials that has done for making the fertilizing-counter plan on the soil improving species, some results have been got as follows; 1. In the non-phosphorus dressing plots soil improving species have very poor survial ratio and show us to be died step by step. It may be resons that root can not make the nodule in case of non-phosphorus dressing and so tree could not absorb the nitrogen nutrient fixed by the nodule. And root competition with the weedy speces for utilizing the nutrient and oxygen in the soil could be reasons when planting in the heavy weedy rooting site. 2. Triple super phosphate, Fused Mg Phosphate and Fused super phosphate have showed the remarkable effects on the growth of soil improving species within 3rd year after planting. But Koreaan tablet fertilizer(9-12-4) for forest purpose have reacted considerably lower effect in comparision with the above powder and grain type phosphorous fertilizer. 3. In case of tablet type fertilizer tree root will have very little phosphorus absorbing surface because phosphorus can be utilized only from the tablet surface and root can not penetrate into the tablet. This my be reson to show the poor dressing reaction of tablet fertilizer but tablet fertilizer has a possibility to be utilized during long years as a sympton in photo 6. So tablet fertilizer can have a recommendation to dress much fertilizer at p]anting year and then tree root can get much more chance for absorbing the phosphorus that could keep the high survival and for utilizing it during many years without after dressing. 4. The granurar and powder type phosphate can develop the dense root mat like photo 8 because of giving the large surface for absorbing the phosphorus and weedy root can approch to the nodule for taking the nitrogen element. So this type seems to present better effect than tablet type to control the soil movement, stem weight as 200g per meter(l meter long${\times}$0.1m width). When added the lime any effect could not be found and rather give the negative effect. So Lespedeza seed sowing and phosphorus dressing system seems us to be very reasonable method for covering the raw material of basket making, fodder and fuel wood supply. 7. Fused Mg phosphate and Fused super phosphate are good fertilizer to the soil improving species and dressing more than 30g per seedling can be recommendable amount. 5. In the unproductive and dry soil with phosphorus fertilizer Robinia pseudoacacia and Alnus firnui can grow more than 2.3m in height at 3rd year and Alnus inokumae have the rapid height growth that is more than 1.8m at 2nd year. Depending on the growth situation like the above example minirotated management has possibilities and rapid covering of erosed land can be done with the soil improving species and phosphorus fertilizer. 6. In the Lespedeza sowing plot with 40g Fused Mg phosphate dressing per meter in the eroded and unproductive forest soil Lespedeza have completely covered this poor land and produced the green.

  • PDF

Development of Adjustable Head holder Couch in H&N Cancer Radiation Therapy (두경부암 방사선 치료 시 Set-Up 조정 Head Holder 장치의 개발)

  • Shim, JaeGoo;Song, KiWon;Kim, JinMan;Park, MyoungHwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.43-50
    • /
    • 2014
  • In case of all patients who receive radiation therapy, a treatment plan is established and all steps of treatment are planned in the same geometrical condition. In case of head and neck cancer patients who undergo simulated treatment through computed tomography (CT), patients are fixed onto a table for planning, but laid on the top of the treatment table in the radiation therapy room. This study excogitated and fabricated an adjustable holder for head and neck cancer patients to fix patient's position and geometrical discrepancies when performing radiation therapy on head and neck cancer patients, and compared the error before and after adjusting the position of patients due to difference in weight to evaluate the correlation between patients' weight and range of error. Computed tomography system(High Advantage, GE, USA) is used for phantom to maintain the supine position to acquire the images of the therapy site for IMRT. IMRT 4MV X-rays was used by applying the LINAC(21EX, Varian, U.S.A). Treatment planning system (Pinnacle, ver. 9.1h, Philips, Madison, USA) was used. The setup accuracy was compared with each measurement was repeated five times for each weight (0, 15, and 30Kg) and CBCT was performed 30 times to find the mean and standard deviation of errors before and after the adjustment of each weight. SPSS ver.19.0(SPSS Inc., Chicago, IL,USA) statistics program was used to perform the Wilcoxon Rank test for significance evaluation and the Spearman analysis was used as the tool to analyze the significance evaluation of the correlation of weight. As a result of measuring the error values from CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.4{\pm}0.8mm$, $0.8{\pm}0.4mm$, 0 for 0Kg before the adjustment. In 15Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.2{\pm}0.8mm$, $1.2{\pm}0.4mm$, $2.0{\pm}0.4mm$. After adjusting position was X,Y,Z axis was $0.2{\pm}0.4mm$, $0.4{\pm}0.5mm$, $0.4{\pm}0.5mm$. In 30Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.8{\pm}0.4mm$, $2.4{\pm}0.5mm$, $4.4{\pm}0.8mm$. After adjusting position was X,Y,Z axis was $0.6{\pm}0.5mm$, $1.0{\pm}0mm$, $0.6{\pm}0.5mm$. When the holder for the head and neck cancer was used to adjust the ab.0ove error value, the error values from CBCT were $0.2{\pm}0.8mm$ for the X axis, $0.40{\pm}0.54mm$ for Y axis, and 0 for Z axis. As a result of statistically analyzing each value before and after the adjustment the value was significant with p<0.034 at the Z axis with 15Kg of weight and with p<0.038 and p<0.041 at the Y and Z axes respectively with 30Kg of weight. There was a significant difference with p<0.008 when the analysis was performed through Kruscal-Wallis in terms of the difference in the adjusted values of the three weight groups. As it could reduce the errors, patients' reproduction could be improved for more precise and accurate radiation therapy. Development of an adjustable device for head and neck cancer patients is significant because it improves the reproduction of existing equipment by reducing the errors in patients' position.