• 제목/요약/키워드: Site assessment test

검색결과 219건 처리시간 0.022초

3D 카메라 기반 직업성 근골격계 부담 작업 모니터링 장치 (A On-site Monitoring Device of Work-related Musculoskeletal Disorder Risk Based on 3D-Camera)

  • 노병국
    • 한국안전학회지
    • /
    • 제30권6호
    • /
    • pp.110-116
    • /
    • 2015
  • A 3D camera-based on-site work-related musculoskeletal disorder risk assessment(WMDs) tool has been developed. The device consists of Kinect a 3D camera manufactured by Microsoft, a servo-motor, and a mobile robot. To complement inherent narrow field of view(FOV) of Kinect, Kinect is rotated according to PID servo-control algorithm by a servo-motor attached underneath, to track movement of a subject, producing skeleton-based motion data. With servo-control, full 360 degrees tracking of a test subject is possible by single Kinect. It was found from experimental tests that the proposed device can be successfully employed for on-site WMDs risk assessing tool.

Static Analysis Tools Against Cross-site Scripting Vulnerabilities in Web Applications : An Analysis

  • Talib, Nurul Atiqah Abu;Doh, Kyung-Goo
    • 한국소프트웨어감정평가학회 논문지
    • /
    • 제17권2호
    • /
    • pp.125-142
    • /
    • 2021
  • Reports of rampant cross-site scripting (XSS) vulnerabilities raise growing concerns on the effectiveness of current Static Analysis Security Testing (SAST) tools as an internet security device. Attentive to these concerns, this study aims to examine seven open-source SAST tools in order to account for their capabilities in detecting XSS vulnerabilities in PHP applications and to determine their performance in terms of effectiveness and analysis runtime. The representative tools - categorized as either text-based or graph-based analysis tools - were all test-run using real-world PHP applications with known XSS vulnerabilities. The collected vulnerability detection reports of each tool were analyzed with the aid of PhpStorm's data flow analyzer. It is observed that the detection rates of the tools calculated from the total vulnerabilities in the applications can be as high as 0.968 and as low as 0.006. Furthermore, the tools took an average of less than a minute to complete an analysis. Notably, their runtime is independent of their analysis type.

진동시험에 기초한 액상화 상세예측법 개발 (A New Assessment of Liquefaction Potential Based on the Dynamic Test)

  • 김수일;최재순;강한수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.245-252
    • /
    • 2004
  • When some enormous earthquake hazards broke out in the neighboring Japan and Taiwan, many Korean earthquake engineers thought that seismic guidelines must be adjusted safely and economically to consider the moderate earthquake characteristics. In the present aseismic guideline for liquefaction potential assessment, a simplified method using SPT-N value and a detail method based on the dynamic lab-tests were introduced. However, it is said that these methods based on the equivalent stress concept to simplify an irregular earthquake are not reliable to simulate the kaleidoscopical characteristics of earthquake loading correctly. Especially, even though various data from the dynamic lab-test can be obtained, only two data, a maximum cyclic load and a number of cycle at an initial liquefaction are used to determine the soil resistance strength in the detailed method. In this study, a new assessment of liquefaction potential is proposed and verified. In the proposed assessment, various data from dynamic lab-tests are used to determine the unique soil resistance characteristic and a site specific analysis is introduced to analyze the irregular earthquake time history itself. Also, it is found that the proposed assessment is reasonable because it is devised to reflect the changeable soil behavior under dynamic loadings resulted from the generation and development of excess pore water pressure.

  • PDF

건설현장 근로자인 작업복 개발에 관한 연구 (Development of Work Clothing for the Construction Site)

  • 장선옥;최혜선
    • 한국의류학회지
    • /
    • 제30권7호
    • /
    • pp.1090-1102
    • /
    • 2006
  • The purpose of this study is to develop an improved work clothing which is much safe, comfortable, mobility and convenient than what workers currently wear at construction site. The investigation has been conducted to evaluate current work clothing to grasp any problems, discomforts and damages related to the work clothing. For the best and accurate data, hands-on investigation and a short-interview have been performed at the construction site as well as formulating a questionnaire. The questionnaires was answered by 425 workers and safety manager of 13 different construction site. The result of the questionnaire enables us to design a sample work clothing, many pa π s such as material, pattern and design have been improved. To improve the amenity of heat, the surface of a material was used by $Aerocool^{\circledR}$ fiber which contains inside dryness function. In order to absorb perspiration on the back the armpits, mesh martial that is mixture of $Coolever^{TM}$ fiber and $Mirawave^{TM}$ fiber was used to absorb perspiration in an effective manner. And a sleeve's bottom part and trousers' bottom part's cover method have been changed. Sample work clothing was shorten at the side of upper garment up to 2cm and lengthen the length of the back by 3cm. To reduce the tightness around armpit more room was given in that area. Darts were added to the elbow, the hip, and the knees that also followed an ergonomic pattern. A sample work clothing evaluated an objective assessment and subjective assessment to compare to a current work clothing. Assessment group consists of seven subject groups and nine expert groups to evaluate external appearance and adaptability to the movements. In all aspects of the test, the result of evaluation process of the sample work clothing received more positive assessment than the current work clothing.

풍력발전기 성능실증을 위한 단지교정 방법 (Site Calibration for the Wind Turbine Performance Evaluation)

  • 남윤수;유능수;이정완
    • 산업기술연구
    • /
    • 제22권A호
    • /
    • pp.49-57
    • /
    • 2002
  • The accurate wind speed information at the hub height of a wind turbine is very essential to the exact estimation of the wind turbine power performance testing. Several methods on the site calibration, which is a technique to estimate the wind speed at the wind turbine's hub height based on the measured wind data using a reference meteorological mast, are introduced. A site calibration result and the wind resource assessment for the Taekwanryung test site are presented using a one-month wind data from a reference meteorological mast and a temporal mast installed at the site of wind turbine. From this analysis, it turns out that the current location of the reference meteorological mast is wrongly determined, and the self-developed codes for the site calibration are working properly. Besides, an analysis on the uncertainty allocation for the wind speed correction using site calibration is performed.

  • PDF

Liquefaction hazard assessment in a GIS environment: A case study of Buğday Pazarı neighborhood in Çankırı province

  • Erenm Yurdakul;Sevkim Ozturk;Enderm Sarifakioglu
    • Geomechanics and Engineering
    • /
    • 제36권5호
    • /
    • pp.455-464
    • /
    • 2024
  • Seismic movements have varying effects on structures based on characteristics of local site. During an earthquake, weak soils are susceptible to damage due to amplified wave amplitudes. Soil-structure interaction issue has garnered increased attention in Türkiye, after devastating earthquakes in Kocaeli Gölcük (1999), Izmir (2020), Kahramanmaraş Pazarcık and Elbistan (2023). Consequently, liquefaction potential has been investigated in detail for different regions of Türkiye, mainly with available field test results. Çankırı, a city located close to North Anatolian Fault, is mainly built on alluvium, which is prone to liquefaction. However, no study on liquefaction hazard has been conducted thus far. In this study, groundwater level map, SPT map, and liquefaction risk map have been generated using Geographical Information System (GIS) for the Buğday Pazarı District of Çankırı province. Site investigations studies previously performed for 47 parcels (76 boreholes) were used within the scope of this study. The liquefaction assessment was conducted using Seed and Idriss's (1971) simplified method and the visualization of areas susceptible to liquefaction risk has been accomplished. The results of this study have been compared with the City Council's precautionary map which is currently in use. As a result of this study, it is recommended that minimum depth of boreholes in the region should be at least 30m and adequate number of laboratory tests particularly in liquefiable areas should be performed. Another important recommendation for the region is that detailed investigation should be performed by local authorities since findings of this study differ from currently used precautionary map.

Site Calibration for the Wind Turbine Performance Evaluation

  • Nam, Yoon-Su;Yoo, Neung-Soo;Lee, Jung-Wan
    • Journal of Mechanical Science and Technology
    • /
    • 제18권12호
    • /
    • pp.2250-2257
    • /
    • 2004
  • The accurate wind speed information at the hub height of a wind turbine is very essential to the exact estimation of the wind turbine power performance testing. Several methods on the site calibration, which is a technique to estimate the wind speed at the wind turbine's hub height based on the measured wind data using a reference meteorological mast, are introduced. A site calibration result and the wind resource assessment for the TaeKwanRyung test site are presented using three-month wind data from a reference meteorological mast and the other mast temporarily installed at the site of wind turbine. Besides, an analysis on the uncertainty allocation for the wind speed correction using site calibration is performed.

녹색건축 인증제도 평가항목에 대한 설계 실무자 및 사용자 의식 차이 분석 - 공동주택 인증 평가항목을 중심으로 - (Analyzing the Differential Views between the Designers and the Users on Certification Assessment Criteria of the G-SEED System - Focused on Certification Assessment Criteria for Apartment Buildings -)

  • 최여진
    • KIEAE Journal
    • /
    • 제15권6호
    • /
    • pp.87-92
    • /
    • 2015
  • Purpose: The green building certification system in Korea was introduced in 2002 and developed as an improvement version of the G-SEED(Green Standard for Energy and Environmental Design) system in 2013. This study conducts surveys targeting architectural designers and users on significance of certification assessment criteria for apartment buildings on the G-SEED system and examines the differential views between the two groups on assessment criteria. Method: First, The AHP(Analytic Hierarchy Process) method was used to find importance of assessment criteria and then the importances were compared with weighted points on the certification standard. Second, the t-test was used to investigate differential views between designer and user groups on certification assessment criteria based on drawn importances. Result: (1) While designer group considered land use and transportation, energy and environmental pollution, and water circulation management as more important, user group did material and resource, maintenance management, ecological environment, and indoor environment as more important. (2) Based on t-test results, sustainable energy, water circulation system, site management, habitat, acoustical environment, and light environment were found to be different on importance between the two groups.

THE USE OF NUMERICAL MODELS IN SUPPORT OF SITE CHARACTERIZATION AND PERFORMANCE ASSESSMENT STUDIES FOR GEOLOGICAL REPOSITORIES

  • Neerdael, Bernard;Finsterle, Stefan
    • Nuclear Engineering and Technology
    • /
    • 제42권2호
    • /
    • pp.145-150
    • /
    • 2010
  • The paper is describing work being developed in the frame of a 5-year IAEA Coordinated Research Programme (CRP) started in late 2005. Participants gained knowledge of modelling methodologies and experience in the development and use of rather sophisticated simulation tools in support of site characterization and performance assessment calculations. These goals were achieved by a coordinated effort, in which the advantages and limitations of numerical models are examined and demonstrated through a comparative analysis of simplified, illustrative test cases. This knowledge and experience should help them address these issues in their own country's nuclear waste program. Coordination efforts during the first three years of the project aimed at enabling this transfer of expertise and maximizing the learning experience of the participants as a group. This was accomplished by identifying common interests of the participants (i.e., Process Modelling and Total System Performance Assessment methodology), and by defining complementary tasks that are solved by the members. Synthesis of all available results by comparative assessments is planned in the coming months. The project will be completed end of 2010. This paper is summarizing activities up to November 2009.

수술부위감염이 재원일수와 비용에 미치는 영향 (The effect of surgical site infection on the length of stay and health care costs)

  • 장진희;김경훈;권순만;염선아;박춘선
    • 보건행정학회지
    • /
    • 제21권1호
    • /
    • pp.44-60
    • /
    • 2011
  • Background : Surgical site infection(SSI) is one of the important nosocomial infections with pneumonia, urinary tract infection. SSI increases mortality, morbidity, length of stay, and costs for postoperative patients. The purpose of this study was to estimate length of stay(LOS) and health care costs from SSI using the large observational data. The ultimate objective was to show the effect of prevention of SSI. Method : This study used antibiotic prophylaxis evaluation data and claims data of the HIRA(Health Insurance Review and Assessment Service). The study population included 18,361 patients who underwent gastric surgery, endoscopic cholecystectomy, colon surgery, hysterectomy, cesarean section in nationwide hospitals from August to October 2007. SSI group and non-SSI group were matched according to propensity score resulted from logistic regression. The paired t-test was used to compare the difference of the LOS and health care costs between SSI group and non-SSI group. Results : The 598 cases of SSI were detected of total subjects, and the crude SSI rate was 3.3%. For each surgery, SSI rates were 5.5% for gastric surgery, 4.7% for cholecystectomy, 6.6% for colon surgery, 2.6% for hysterectomy, and 1.6% for cesarean section. The 596 cases of SSI and the 596 cases of non-SSI were matched by propensity score. The LOS of SSI group was longer than that of non-SSI group, and the difference was statistically significant. Health care costs of SSI group was more than that of non-SSI group which was significant. Conclusions : SSI increased apparently the LOS and healthcare costs. The economic loss might affect the cost of national healthcare as well as patients and hospitals. This study provided the evidence that the healthcare expenditure could be reduced by preventing SSI.