• Title/Summary/Keyword: Siphon Effect

Search Result 11, Processing Time 0.023 seconds

A Micro Shunt Valve with Anti-siphon Effect

  • Lee, Sang-Wook;Yoon, Hyeun-Joong;Yang, Sang-Sik
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.1
    • /
    • pp.31-34
    • /
    • 2004
  • This paper presents the fabrication and testing of a two-way pressure regulation micro shunt valve with an anti-siphon effect that can be implanted in hydrocephalus patients. This micro shunt valve consists of a silicone rubber membrane and a valve seat for the opening pressure control as well as the anti-siphon behavior. The two-way pressure regulation and the anti-siphon effect of the micro shunt valve are verified experimentally for various sizes of membranes and valve seats.

Analysis of Design Parameters For Shunt Valve and Anti-Siphon Device Used to Treat Patients with Hydrocephalus

  • Lee, Chong-Sun;Jang, Jong-Yun;Suh, Chang-Min
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.7
    • /
    • pp.1061-1071
    • /
    • 2001
  • The present study investigated design parameters of shunt valves and anti-siphon device used to treat patients with hydrocephalus. The shunt valve controls drainage of cerebrospinal fluid (CSF) through passive deflection of a thin and small diaphragm. The anti-siphon device(ASD) is optionally connected to the valve to prevent overdrainage when the patients are in the standing position. The major design parameters influencing pressure-flow characteristics of the shunt valve were analyzed using ANSYS structural program. Experiments were performed on the commercially available valves and showed good agreements with the computer simulation. The results of the study indicated that predeflection of the shunt valve diaphragm is an important design parameter to determine the opening pressure of the valve. The predeflection was found to depend on the diaphragm tip height and could be adjusted by the diaphragm thickness and its elastic modulus. The major design parameters of the ASD were found to be the clearance (gap height) between the thin diaphragm and the flow orifice. Besides the gap height, the opening pressure of the ASD could be adjusted by the diaphragm thickness, its elastic modulus, area ratio of the diaphragm to the flow orifice. Based on the numerical simulation which considered the increased subcutaneous pressure introduced by the tissue capsule pressure on the implanted shunt valve system, optimum design parameters were proposed for the ASD.

  • PDF

A Study on Accalerated Vocous Condition in Siphon Spillway (싸이폰식 여수토의 진공촉진에 대한 연구)

  • 김시원
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.6 no.2
    • /
    • pp.816-825
    • /
    • 1964
  • 1. Outline: The flow of the siphon spillway is very intricate and affected by vacuous condition. It is an intresting problem to make vacuum rapidly in_siphon, i.e, to provoke the perfect siphonaoge with the lowest water-level of overflow. The hydraulic experiments of siphon spillway have practiced at the Masan Lake, Haenam, the province of Junnam and gained rational and economical results which cannot be odtained by calculation. 2. Experiment: The model scale was a half of that of the prototype. 3. Results and discussion: In the experiments of 14 runs, washing, overflow water level, outlet, water level of cushion, phenomenon of water flying and water pressure of every part, etc. were studied. a) The relation of overflow water-level at siphon inlet and deflector When the elevation of the deflector is 10. 65m and the form of deflector O.4m long is the hypotenuse of an $45^{\circ}$ isosceles triangle, the over flow water-level is the minimum, i. e. the siphonage was excellent. There is no effect by the rising of overflow water-Ievel between 11.95m to 1O.65m of deflector elevation (in the first plan, it is 11.05m). But the overflow water-level rises remarkably in the outside region of the above limits. b) The relation of overflow water-level, the length of cushion and standard height of the base. The reduction of the length of cushion brings the rising of overflow waterlevel, and the rising of the standard height of the base brings the rising of overflow water level. For the long cushion length and low standard height of the base, it cannot be expeted to have the falling of overflow water-level. The most satisfactory data were obtained at 5.20m of the base standard height and 6.1m of the length of cushion. The first vah,le planned was 5.70 m and 4.30m.

  • PDF

A Determination of Discharge Head of the Cherepnov Water Lifter with Siphon (Siphon을 이용한 Cherepnov 送水機의 揚程 決定)

  • 이관수;이경훈
    • Water for future
    • /
    • v.29 no.1
    • /
    • pp.213-220
    • /
    • 1996
  • This paper presents an experimental study on the discharge head of Cherepnov water lifter that was continuously operated with the aid of the siphon. The energy used by the Cherepnov water lifter is derived from the potential energy ofthe water itself. The lifter consists of three interconnected tanks and five pipes, one of which is open and two others are hermetically sealed. The effects of varying operating parameters such as the tank and pipe size, the ratio between head of discharge and drop height were analyzed. As a result, factors that can maximize the efficiency and increase the average delivery rate were indentified. When the ratio between head of discharge and drop height is about 0.5, the efficiency of Cherepnov water lifter is maximized. In order to design the efficient Cherepnov water lifter, the discharge head of the Cherepnov water lifter should be assigned to be twice as much as the drop height. The effect of tank size on the efficiency is less than 5%, while the effect of the pipe size is not negligible. The larger the pipe size is, the more the efficiency increases.

  • PDF

Analysis on Flood Control Effect of Siphon Spillway by Reservoir Routing (저수지 추적을 통한 사이펀 여수로의 홍수조절 효과 분석)

  • Ko, Suhyeon;Kim, Jaeyoung;Lee, Giha
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.11
    • /
    • pp.55-63
    • /
    • 2013
  • Agricultural small dam reservoirs in Korea are vulnerable to flooding because of insufficient flood control capacity and deterioration such that reservoir water level is likely to rise rapidly and a large amount of water release quickly to downstream without flood warning. In this study, we performed hydrologic analysis to estimate design flood(200 years return period ${\times}1.2$) and also evaluated the effect of siphon spillway as a structural countermeasure for flood control and mitigation by applying reservoir routing to the Jipyeong reservoir, located in Sangju, Korea. The results show that the design flood was calculated at $284.3m^3/s$, and water level and water release decreased by 40cm and $91m^3/s$, respectively.

Effects of Protease Treatment and Animal Behavior on the Dissociative Culture of Aplysia Neurons

  • Lee, Nuribalhae;Rim, Young-Soo;Kaang, Bong-Kiun
    • Animal cells and systems
    • /
    • v.13 no.3
    • /
    • pp.267-274
    • /
    • 2009
  • The dissociative culture technique of Aplysia neuron is one of the key methods that have been used for studies of cellular and molecular mechanisms of neuronal functioning. However, despite the advantages this method offers as an experimental model, its technical efficiency has had room for improvement. In this study, we examined certain putative factors that might affect the culture quality. The effects of neuronal damage induced by physical injuries, heat shock, and surface protein degradation were evaluated along with the correlation between the culture quality and animal behavior. As a result, we found that physical injury can be a critical factor that affects culture quality, whereas the heat shock and surface protein degradation had negligible effect on it. In addition, we discovered that siphon retraction time was not a good measurement for healthy neurons. Based on these findings, we suggest here an improved method in which the degree of physical injury is reduced by means of multiple protease treatment.

High Temperature Solar Gas Heating by a Compact Fluidized-Bed Receiver of Closed-Type (밀폐형 유동층을 이용한 태양광 고온가스가열 장치의 연구)

  • Choi, Jun-Seop
    • Solar Energy
    • /
    • v.12 no.1
    • /
    • pp.88-94
    • /
    • 1992
  • A small-scale solar collector and tracking system, using a Fresnel lens of $0.5m^2$, and novel compact fluidized-bed solar receiver[FBR] of closed type has been developed for high temperature solar gas heating. The FBR was improved in carrying over of SiC powder and thermo-siphon effect. The maximum outlet air temperature of 1140K and the maximum thermal efficiency of 64% were obtained. The present FBR's operated efficiently at extremely high temperatures in comparison with conventional solar receivers, composed of flat or tubular solid surfaces.

  • PDF

Effect of Ginkgo biloba extract in treatment of cerebral infarction (腦硬塞 患者에서 銀杏葉椎出物의 治療效果)

  • Park, Yang-chun;Lim, Seok-in;Kim, Byeong-tak
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.11 no.1
    • /
    • pp.240-250
    • /
    • 1998
  • Background: Ginkgo biloba extract is used in disorser of cerebral and peripheral blood circulation, dysfunction of brain, atherosclerosis etc., but there are little study about GbE in oriental medicine. We wished to assessthe efficacy of GbE for the treatment of cerebral infarction Method : The study group comprised 40 patients who arrived at hospital during 48 hours after attack. All patient were devided into two group. The control group was treated with Uhuangcheongsimhuan, Seonghyangjeonggisan, acupuncture therapy only, while the GbE group was treated with above therapy plus 5 days of administration of GbE(40mg three times per day). Result: 1. Symptom improve scores did not showed significant difference between control and GbE group. 2. Vasoreactivity of carotid siphon increased significantly in GbE group after treatment (in the left only : p<0.05). 3. Vasorcactivity of radial artery increased significantly in GbE group after treatment(in the right only ; p<0.05). 4. PT, a-PTT, Fibrinogen did not showed significant changes between before and after treatment in both group. Conclusion: These findings suggest that vasoreactivity increasing effect of GbE may be useful in the prevention and treatment of cerebral infarction. But the vasoreactivity increasing effect of GbE may be different from symptom imroving.

  • PDF

Investigation of two-phase natural circulation with the SMART-ITL facility for an integral type reactor

  • Jeon, Byong Guk;Yun, Eunkoo;Bae, Hwang;Yang, Jin-Hwa;Ryu, Sung-Uk;Bang, Yun-Gon;Yi, Sung-Jae;Park, Hyun-Sik
    • Nuclear Engineering and Technology
    • /
    • v.54 no.3
    • /
    • pp.826-833
    • /
    • 2022
  • A two-phase natural circulation test using SMART integral test loop (SMART-ITL) was conducted to explore thermo-hydraulic phenomena of two-phase natural circulation in the SMART reactor. Specifically, the test examined the natural circulation in the primary loop under a stepwise coolant inventory loss while keeping the core power constant at 5% of the scaled full power. Based on the test results, three flow regimes were observed: single-phase natural circulation (SPNC), two-phase natural circulation (TPNC), and boiler-condenser natural circulation (BCNC). The flow rate remained steady in the SPNC, slightly increased in the TPNC, and dropped abruptly and maintained in the BCNC. Using a natural circulation flow map, the natural circulation characteristic in the SMART-ITL was compared with those in pressurized water reactor simulators. In the SMART-ITL, a BCNC regime appeared instead of siphon condensation and reflux condensation regimes because of the use of once-through steam generators.

STUDIES ON THE SHELLFISH PROCESSING 1. Purification of the Surf Clam Mactra sulcataria REEVE for the Remove of Sand (패류 가공에 관한 연구 1. 개량조개 Mactra Sulcataria REEVE의 토사 배출에 대하여)

  • LEE Eung-Ho;PYEUN Jae-Hyeung;HUR Jong-Wha
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.3 no.1
    • /
    • pp.27-32
    • /
    • 1970
  • A study on the purification of the surf clam Mactra Sulcataria REEVE for the remove of sand and fecal piles was conducted in the laboratory. The sand was mostly distributed around the inhalent and exhalent siphon, mantle and gill, and were also distributed in the digestive tract including the mid-gut gland. The sand particles in the digestive tract were extremely small and their sizes were about $180\times10\mu\;to\;550\times200\mu$. It could be seen that there was little, if any, difference in the rate of sand removal when either the hanging Purification method was used or the method of laying the surf clams in thick or thin layers on the bottom of the experimental vessel was used. The surf clam removed about $50\%$ of its sand during the first hour of purification. The weight of the removed sand and fecal piles on a dry basis reached a constant value after 22 to 26 hours of purification. After 42 hours of Purification, no sand could be seen in the fecal piles. The surf clam removed the sand in its body more rapidly when it was in sea water with the pH of 8.75 than when it was in natural sea water. Also high temperature had a much greater depressing effect upon the removal of sand In the surf clam than did natural sea water. Also low salinity had greater accelerating effect upon the removal of sand in the body than did natural sea water. However the surf clam died when the salinity was $8.19\%_{\circ}$.

  • PDF