• 제목/요약/키워드: Sinusoidal rotation

검색결과 41건 처리시간 0.034초

Study of the Dependency of the Specific Power Absorption Rate on Several Characteristics of the Excitation Magnetic Signal when Irradiating a SPION-containing Ferrofluid

  • Rosales, Alejandra Mina;Aznar, Elena;Coll, Carmen;Mendoza, Ruben A. Garcia;Bojorge, A. Lorena Urbano;Gonzalez, Nazario Felix;Martinez-Manez, Ramon;del Pozo Guerrero, Francisco;Olmedo, Jose Javier Serrano
    • Journal of Magnetics
    • /
    • 제21권3호
    • /
    • pp.460-467
    • /
    • 2016
  • Magnetic hyperthermia mediated by superparamagnetic particles is mainly based in sinusoidal waveforms as excitation signals. Temperature changes are conventionally explained by rotation of the particles in the surrounding medium. This is a hypothesis quite questionable since habitual experimental setups only produce changes in the magnetic module, not in the field lines trajectories. Theoretical results were tested by changing the waveform of the exciting signal in order to compare non-sinusoidal signals against sinusoidal signals. Experiments were done at different frequencies: 200 KHz, 400 KHz, 600 KHz, 800 KHz and 1 MHz. Superparamagnetic Iron Oxide samples (SPION), made of magnetite ($Fe_3O_4$) and suspended in water (100 mg/ml), were used. Magnetic field strength varies from $0.1{\pm}0.015KA/m$ to $0.6{\pm}0.015KA/m$. In this study was observed that the power loss depends on the applied frequency: for 1 to 2.5 RMS current the responses for each signal are part of the higher section of the exponential function, and for 3.5 to 8 RMS current the response is clearly the decrement exponential function's tale (under $1{\times}10^3LER/gr$).

Temporal Changes in Neuronal Activity of the Bilateral Medial Vestibular Nuclei Following Unilateral Labyrinthectomy in Rats

  • Park, Byung-Rim;Lee, Moon-Young;Kim, Min-Sun;Lee, Sung-Ho;Na, Han-Jo;Doh, Nam-Yong
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제3권5호
    • /
    • pp.481-490
    • /
    • 1999
  • To investigate the changes in the responses of vestibular neurons with time during vestibular compensation, the resting activity and dynamic responses of type I and II neurons in the medial vestibular nuclei to sinusoidal angular acceleration were recorded following unilateral labyrinthectomy (ULX) in Sprague-Dawley rats. The unitary extracellular neuronal activity was recorded from the bilateral medial vestibular nuclei with stainless steel microelectrodes of $3{\sim}5\;M{\Omega}$ before ULX, and 6, 24, 48, 72 hours, and 1 week after ULX under pentobarbital sodium anesthesia (30 mg/kg, i.p.). Gain (spikes/s/deg/s) and phase (in degrees) were determined from the neuronal activity induced by sinusoidal head rotation with 0.05, 0.1, 0.2, and 0.4 Hz. The mean resting activity before ULX was $16.7{\pm}8.6$ spikes/s in type I neurons $(n=67,\;M{\pm}SD)$ and $14.5{\pm}8.4$ spikes/s in type II neurons (n=43). The activities of ipsilateral type I and contralateral type II neurons to the lesion side decreased markedly till 24 hr post-op, and a significant difference between ipsilateral and contralateral type I neurons sustained till 24 hr post-op. The gain at 4 different frequencies of sinusoidal rotation was depressed in all neurons till 6 or 24 hr post-op and then increased with time. The rate of decrease in gain was more prominent in ipsilateral type I and contralateral type II neurons immediately after ULX. Although the gain of those neurons increased gradually after 24 hours, it remained below normal levels. The phase was significantly advanced in all neurons following ULX. These results suggest that a depression of activities in ipsilateral type I and contralateral type II neurons is closely related with the occurrence of vestibular symptoms and restoration of activities in those neurons ameliorates the vestibular symptoms.

  • PDF

Design of a Propagation Wave Type Microrobot for Moving on the Slippery Surface

  • Kim, Eui-Jin;Park, Jong-Hyeon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2072-2077
    • /
    • 2003
  • Animal-like robots are serving an important role as a linkage between biology and engineering. So, in this paper, we aim to develop a biomimetic microrobot that mimics the locomotion mechanism of a gastropod. This microrobot has 3 DOF (x, y translation and rotation), and has small size, unlimited traveling range, high resolution and low cost. Its movement can be made using propagation wave that is generated by the controllable sinusoidal voltage source and piezoelectric effects. This soft motion that can be generated by propagation wave and piezoelectric mechanism would be useful for the motion on the slippery surface. So we modeled the propagation wave mechanism including piezoelectric effect and friction on the contact surface, and could know the velocity of the microrobot is dependent on the driving frequency, input voltage peak, propagation wavelength and surface friction coefficient. With these results we design the microrobot, and accomplish its fabrication and experimentation. The development of this microrobot shall be aimed to design an autonomous moving actuator like animal. Also it can be used from micromanipulation system technology to biology and medicine.

  • PDF

페룰 동축연삭시 척킹 오차 해석 (A study on the chucking alignment error analysis in coaxial grinding of ferrule)

  • 김동길;김영태;이상조
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.9-14
    • /
    • 2002
  • Ferrule is widely used as fiber optic connecters. In fiber-optic communications, the shape accuracy such as coaxiality and cylindricity of ferrule affects insertion loss. When coaxial grinding of ferrule supported by two pin, pin alignment and chucking accuracy are very important. In this research, the kinematic behavior of the ferrule center is investigated in the case where cone-shaped center pins and round circle hales which make contact with each other near the edge of the holes, using homeogenous coordinate transformation and numerical analysis. The obtained results are as follows: The alignment errors between center pins alone do not affect the rotation accuracy of ferrule. The alignment errors between center holes cause a sinusoidal displacement of ferrule. And the maximum displacement of ferrule centers increase in proportion to the center pin angle in the case of a fixed alignment errors

  • PDF

초전도 플라이휠 에너지 저장시스템의 개발 (Development of Flywheel Energy Storage System Using Superconducting Magnetic Bearing)

  • 정환명;연제욱;최재호;고창섭
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.427-430
    • /
    • 1999
  • This paper presents a S-FES(Superconducting magnetic bearing Flywheel Energy Storage System) for the purpose of replacing battery used to store the energy. Especially, the design elements of FES, such as the bearing, wheel material, and power converter, etc., is described. The design and manufacturing techniques of the controllable power converter are proposed to generate the sinusoidal output current in the high speed operation and to get the constant DC voltage in the regeneration mode. The cylindrical permanent magnet synchronous motor with halbach array of Nd-Fe-B permanent magnet which is the high coercivity material is used as the driver of FES. The proposed S-FES system shows the stable rotation characteristics at high speed range about 10,000 rpm. To verify the validity of proposed system, the comparative study with the conventional ball bearing system is proceeded and it is well confirmed with the result of the lower friction loss of S-FES system.

  • PDF

공작기계 열오차 모델의 최적 센서위치 선정 (Selection of Optimal Sensor Locations for Thermal Error Model of Machine tools)

  • 안중용
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1999년도 추계학술대회 논문집 - 한국공작기계학회
    • /
    • pp.345-350
    • /
    • 1999
  • The effectiveness of software error compensation for thermally induced machine tool errors relies on the prediction accuracy of the pre-established thermal error models. The selection of optimal sensor locations is the most important in establishing these empirical models. In this paper, a methodology for the selection of optimal sensor locations is proposed to establish a robust linear model which is not subjected to collinearity. Correlation coefficient and time delay are used as thermal parameters for optimal sensor location. Firstly, thermal deformation and temperatures are measured with machine tools being excited by sinusoidal heat input. And then, after correlation coefficient and time delays are calculated from the measured data, the optimal sensor location is selected through hard c-means clustering and sequential selection method. The validity of the proposed methodology is verified through the estimation of thermal expansion along Z-axis by spindle rotation.

  • PDF

Analytical approximate solutions for large post-buckling response of a hygrothermal beam

  • Yu, Yongping;Sun, Youhong
    • Structural Engineering and Mechanics
    • /
    • 제43권2호
    • /
    • pp.211-223
    • /
    • 2012
  • This paper deals with large deformation post-buckling of a linear-elastic and hygrothermal beam with axially nonmovable pinned-pinned ends and subjected to a significant increase in swelling by an alternative method. Analytical approximate solutions for the geometrically nonlinear problem are presented. The solution for the limiting case of a string is also obtained. By coupling of the well-known Maclaurin series expansion and orthogonal Chebyshev polynomials, the governing differential equation with sinusoidal nonlinearity can be reduced to form a cubic-nonlinear equation, and supplementary condition with cosinoidal nonlinearity can also be simplified to be a polynomial integral equation. Analytical approximations to the resulting boundary condition problem are established by combining the Newton's method with the method of harmonic balance. Two approximate formulae for load along axis, potential strain for free hygrothermal expansion and periodic solution are established for small as well as large angle of rotation at the end of the beam. Illustrative examples are selected and compared to "reference" solution obtained by the shooting method to substantiate the accuracy and correctness of the approximate analytical approach.

고배속 광디스크 적용을 위한 외란 관측기 설계 (Disturbance Observer Design for a High Speed Optical Disk Drive)

  • 이주상;최진영;박노철;양현석;박영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.1170-1175
    • /
    • 2003
  • Recently, the disturbance caused by an optical disk vibration and the external vibration/shock are more serious problem in an optical disk drives (ODD) as an ODD become small size and rotation speed increases. The conventional controller cannot cope with the mentioned problems properly when the disturbance and vibration are larger than some range. Therefore, we propose a new control scheme using a disturbance observer (DOB) and it can control the aforementioned problems. The designed the controller is applied to a commercial ODD in focusing direction, then its validity is proved by experimental method. By rising the disturbance observer theory, the focusing performance is conspicuously improved in the presence of sinusoidal vibrations or a shock disturbance. This algorithm also applies to a tracking structure also, because focusing structure is very similar to it.

  • PDF

Robust Optical Detection Method for the Vibrational Mode of a Tuning Fork Crystal Oscillator

  • Choi, Hyo-Seung;Song, Sang-Hun
    • 센서학회지
    • /
    • 제24권2호
    • /
    • pp.93-95
    • /
    • 2015
  • We present an optical detection method for the fundamental vibrational mode of a tuning fork crystal oscillator in air. A focused He/Ne laser beam is directed onto the edge of one vibrating tine of the tuning fork; its vibrating motion chops the incoming laser beam and modulates the intensity. The beam with modulated intensity is then detected and converted to an electrical signal by a high-speed photo-detector. This electrical signal is a sinusoid at the resonant frequency of the tuning fork vibration, which is 32.76 kHz. Our scheme is robust enough that the sinusoidal signal is detectable at up to $40^{\circ}$ of rotation of the tuning fork.

Trans-sinusoidal maxillary distractor($TS-MD^{(R)}$)를 이용한 구순구개열 환자에서의 상악골 골신장술 (Maxillary Distraction Osteogenesis Using $TS-MD^{(R)}$ (Trans-sinusoidal Maxillary distractor) on Cleft Patients)

  • 팽준영;이일구;명훈;황순정;서병무;최진영;이종호;정필훈;김명진
    • 대한구순구개열학회지
    • /
    • 제8권2호
    • /
    • pp.71-79
    • /
    • 2005
  • Purpose: Maxillary hypoplasia is a common developmental problem of cleft lip and palate. Fair results with distraction osteogenesis have been reported especially when these patients need a large amount of maxillary advancement, instead of orthognathic surgery. The purpose of this study is to evaluate the clinical results with a relatively new distractor, $TS-MD^{(R)}$ (Trans-sinusoidal maxillary distractor, KLS Martin, Tuttlingen, Germany) which was used for the advancement of the maxilla in the cleft patients. Patients and Method: Distraction osteogenesis using $TS-MD^{(R)}$ was performed for four CLP patients (three males and one female) who had maxillary hypoplasia. All patients were over 16 years old. As three patients showed mandibular prognathism as well, bilateral sagittal split ramus osteotomy for mandibular setback was performed at the same time. After consolidation periods of 4 to 12 weeks, the distraction devices were removed and miniplates were placed for simultaneous internal fixation. Results: Three patients showed a large amount of incisal overbite but one patient did not have sufficient maxillary advancement. Le Fort I osteotomy, maxillary advancement and internal fixation should have been performed for the patient when removing the distraction devices. Different from the $clinician{\box}s$ expectation, the amount of maxillary advancement using $TS-MD^{(R)}$ was not sufficient, although the device has rigid mechanical property. Rotation of maxilla during distraction forward and downward was also observed. Conclusion: Even though the maxillary advancement with $TS-MD^{(R)}$ device could be achieved, the clinical control of some characteristics related with the device was necessary. More clinical studies on $TS-MD^{(R)}$ should be performed.

  • PDF