• Title/Summary/Keyword: Sinusoidal

Search Result 1,980, Processing Time 0.024 seconds

A study on real time measuring microscopic movements in sinusoidal phase modulating interferometry using a laser diode (레이저 다이오드를 이용한 정현파 위상변조 간섭에 의한 실시간 극미세 진동 측정에 관한 연구)

  • 강성철;진상규;지철근
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1991.10a
    • /
    • pp.33-37
    • /
    • 1991
  • A now signal precessing system for real time displacement measurement in sinusoidal phase modulating interferometry is described. Although sinusoidal phase modulating interferometry is effective in measuring with high accuracy the displacement of an object, conventional signal processing takes along time. In this method, detection of the object's displacement is easily achieved by sampling the interference signal at those times that satisfy certain conditions and by processing the sampled signals with electric circuits in real time. the delay time of this signal processing system is < 45 $\mu$s. Specially in this paper we describe all electronic circuit and optical system design

  • PDF

A Grid Current-Controlling Shunt Active Power Filter

  • Tumbelaka, Hanny H.;Borle, Lawrence J.;Nayar, Chemmangot V.;Lee, Seong-Ryong
    • Journal of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.365-376
    • /
    • 2009
  • In this paper, the implementation of a three-phase shunt active power filter is presented. The filter is essentially three independent single-phase current-controlled voltage source inverters (CC-VSI) with a common DC bus. The CC- VSI is operated to directly control the AC grid current to be sinusoidal and in phase with the grid voltage without detecting the load currents. The APF consists of a current control loop, which shapes the grid currents to be sinusoidal and a voltage control loop, which regulates the active power balance of the system. The experimental results indicate that the active filter is able to handle predominantly the harmonics, as well as the unbalance and reactive power, so that the grid currents are sinusoidal, in phase with the grid voltages and symmetrical.

The Modelling and Characteristic Analysis of Brushless Synchronous Motor with Sinusoidal back EMF (정현파 역기전력 특성을 갖는 브러시리스 동기전동기의 모델링 및 특성해석)

  • Kim, Il-Nam;Baek, Su-Hyeon;Kim, Cheol-Jin;Maeng, In-Jae;Yun, Sin-Yong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.6
    • /
    • pp.380-386
    • /
    • 2000
  • This paper presents the mathematical modelling analysis of Brushless Synchronous Motor(BLSM). The dynamic and the steady state characteristics of BLSM are simulated and analyzed : electromagnetic torque, speed, line voltage, and current. We used mathematical modelling to model of BLSM with sinusoidal back EMF, namely the shaft transformation referencing rotor frame from a, b, c three to produce constant torque like synchronous motor. The experiment result has already similar to compare with simulation result : torque error about 7%, speed error about 5%. The validity of proposed modelling and analysis was confirmed by the experimental result.

  • PDF

Low Rayleigh Number Thermal Convection Between Two Horizontal Plates with Sinusoidal Temperature Distributions (정현적인 온도 분포를 갖는 두 수평 평판 사이에서의 작은 Rayleigh 수 열 대류)

  • 유주식;김용진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.3
    • /
    • pp.145-152
    • /
    • 2001
  • Low Rayleigh number thermal convection in a fluid layer confined between two-infinite horizontal walls kept at spatially sinusoidal temperature distributions, T_L=T_m+\Delta T\sin \kappax,\;T_U=T_m+\Delta T\sin(\kappax-\beta)$, is theoretically investigated by a regular perturbation expansion method. For small wave numbers, an upright cell is formed between the two walls at $\beta$=0. The cell is tilted, as the phase difference increases, and a flow with tow counter-rotating eddies occurs at $\beta=\pi$. when the wave number is large, isolated eddies are formed near the lower and upper walls, for all the phase differences. There exists a wave number at which maximum heat transfer rate at the walls occurs, at each of the phase differences. And the wave number increases with increase of the phase difference. for a fixed wave number, the heat transfer rate decrease with increase of the phase difference.

  • PDF

Wind flow over sinusoidal hilly obstacles located in a uniform flow

  • Lee, Sang-Joon;Lim, Hee-Chang;Park, Ki-Chul
    • Wind and Structures
    • /
    • v.5 no.6
    • /
    • pp.515-526
    • /
    • 2002
  • The wind flow over two-dimensional sinusoidal hilly obstacles with slope (the ratio of height to half width) of 0.5 has been investigated experimentally and numerically. Experiments for single and double sinusoidal hill models were carried out in a subsonic wind tunnel. The mean velocity profiles, turbulence statistics, and surface pressure distributions were measured at the Reynolds number based on the obstacle height(h=40 mm) of $2.6{\times}10^4$. The reattachment points behind the obstacles were determined using the oil-ink dot and tuft methods. The smoke-wire method was employed to visualize the flow structure qualitatively. The finite-volume-method and the SIMPLE-C algorithm with an orthogonal body-fitted grid were used for numerical simulation. Comparison of mean velocity profiles between the experiments and the numerical simulation shows a good agreement except for the separation region, however, the surface pressure data show almost similar distributions.

Sinusoidal Input Power factor Improved for Single-Phase Buck AC-DC Type Converter (정현파 입력 역률개선을 위한 단상 강압형 AC-DC 컨버터)

  • Jung, S.H.;Kwon, K.S.;Lee, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.338-340
    • /
    • 2001
  • Power factor improved for single-phase buck-converter is studied in the paper. To sinusoidal waveform the input current with a near-unity power factor over a wide variety of operating conditions, the output capacitor is operated with voltage reversibility for the supply by arranging the auxiliary diode and power switching device. Then the output voltage is superposed on the input voltage during on time duration of power switching devices in order to minimize the input current distortion caused by the small input voltage when changing the polarity. The tested setup, using two insulated gate bipolar transistors(IGBT) and a microcomputer, is implemented and IGBT are switched with 20[kHz], which is out of the audible band. Moreover, a rigorous state-space analysis is introduced to predict the operation of the rectifier. The simulated results confirm that the input current can be sinusoidal waveform with a near-unity power factor and a satisfactory output voltage regulation can be achieved.

  • PDF

Vibration analysis of a shear deformed anti-symmetric angle-ply conical shells with varying sinusoidal thickness

  • Javed, Saira;Viswanathan, K.K.;Aziz, Z.A.;Lee, J.H.
    • Structural Engineering and Mechanics
    • /
    • v.58 no.6
    • /
    • pp.1001-1020
    • /
    • 2016
  • The study is to investigate the free vibration of antisymmetric angle-ply conical shells having non-uniform sinusoidal thickness variation. The arbitrarily varying thickness is considered in the axial direction of the shell. The vibrational behavior of shear deformable conical shells is analyzed for three different support conditions. The coupled differential equations in terms displacement and rotational functions are obtained. These displacement and rotational functions are invariantly approximated using cubic spline. A generalized eigenvalue problem is obtained and solved numerically for an eigenfrequency parameter and an associated eigenvector of spline coefficients. The vibration characteristic of the shells is examined for cone angle, aspect ratio, sinusoidal thickness variation, layer number, stacking sequence, and boundary conditions.

Speech Unit Concatenation by Phase Succession in an ABS/OLA Sinusoidal Model (ABS/OLA Sinusoidal 모델에서 위상계승을 이용한 단위음성의 연결)

  • Bae Jae-Hyun;Byeon Heo-Jin;Oh Yung-Hwan
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.11-14
    • /
    • 1999
  • 본 논문에서는 중첩가산 Sinusoidal 합성방식에서 매칭된 정현파별로 위상을 계승하는 단위음성 연결방법을 제안한다. 선행 단위음의 마지막 프레임, 후행 단위음의 첫 프레임, 후행 단위음의 나머지 프레임의 단계로 나누어 각 단계마다 제안한 방식으로 선행 프레임의 위상을 계승하였다. 실험결과 후행 단위음의 연결 위치를 이동하는 기존의 방식을 사용한 연결음에 비해 연결부분에서 음성파형의 급격한 변화가 줄었다.

  • PDF

Motor speed and revolution angle detection using a sinusoidal AC tacho-generator (정현파 교류 타코제너레이터를 이용한 전동기 속도 및 회전각 검출)

  • 최정수;유완식;조규민
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.6
    • /
    • pp.94-103
    • /
    • 1997
  • This paper presents motor speed and revolution angle detection method using a sinusoidal AC tacho-generator. The 2-phase or 3-phase output tacho-generator can be adopted, and its' output voltages must have sinusoidal waveforms. Because the detection algorithm is simple, the proosed method can be implemented with analog devices or microprocessor conveniently. And the proposed method has a very short detection delay time. Especially in the analog implementation, there is no delay time without the settling time of analog devices. With the experimental results, it is verified that the proposed method can acculately detect the instantaneous motor speed and revolution angle over the wide ranges.

  • PDF

Evaluation of thermal striping damage for a tee-junction of LMR secondary piping”

  • Lee, Hyeong-Yeon;Kim, Jong-Bum;Bong Yoo;Yoon, Sam-Son
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.837-843
    • /
    • 1998
  • This paper presents the thermomechanical and fracture mechanics evaluation procedure of thermal striping damage on the secondary piping of LMFR using Green's function method and standard FEM. The thermohydraulic loading conditions used in the present analysis are simplified sinusoidal thermal loads and the random type data thermal load. The thermomechainical fatigue damage was evaluated according to ASME code subsectionNH. The analysis results of fatigue for the sinusoidal and random load cases show that fatigue failure would occur at a geometrically discontinuous location during 90,000 hours of operation The fracture mechanics analysis showed that the crack would be initiated at an early stage of the operation. The fatigue crack was evaluated to propagate up to 5 ㎜ along the thickness direction during the first 944 and 1083 hours of operation for the sinusoidal and the random loading cases, respectively.

  • PDF