• 제목/요약/키워드: Single-shot echo planar imaging

검색결과 15건 처리시간 0.023초

관자뼈의 확산강조영상검사 시 Single Shot Turbo Spin Echo 기법의 유용성 (The Utility of Single Shot Turbo Spin Echo Technique for Temporal Bone Diffusion Weighted Imaging)

  • 최관우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권1호
    • /
    • pp.25-30
    • /
    • 2021
  • The purpose was to reduce the distortion of the image that occurs in the temporal bone area due to the very strong differences in susceptibility. A new SS-TSE technique was applied when examining the diffusion-weighted image of the temporal bone, where the auditory and facial nerves to be imaged were very thin and were adjacent to the cranial base including bone and air. This study was conducted from March 2020 to August of the same year, targeting 32 subjects who underwent the diffusion-weighted imaging of the temporal bone. To compare the distortion, existing SS-EPI technique and the new SS-TSE technique were both applied on the temporal bone area. As a result of the study, applying the new SS-TSE technique appeared to lower the distortion of images by 87.44, 46.13 and 42.35 % on the b-value 0, 800 and the ADC images, respectively. In conclusion, when using the new SS-TSE technique on the temporal bone DWI, distortion can be reduced, and thus images with high diagnostic value can be obtained.

${T_2}weighted$- Half courier Echo Planar Imaging

  • 김치영;김휴정;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • 제5권1호
    • /
    • pp.57-65
    • /
    • 2001
  • 목적 : 초고속 Echo Planar Imaging (EPI) 의 데이터 측정시간을 반으로 단축시킨 half courier EPI와 임상에서 널리 사용하는 $T_2$ 강조 영상을 결합한 $T_2$-weighted half courier EPI(T2HEPl) 영상기법을 제안하였다. 제안한 방법으로 강한 $T_2$ 대조도를 갖는 $128{\times}128$의 고해상도 EPI 영상을 single scan으로 얻고자 한다. 대상 및 방법 : 초고속 EPI 기법의 데이터 측정시간을 줄이기 위하여 k-space의 절반만을 측정하고, 나머지 절반은 conjugate symmetry 성질을 이용하여 재구성한다. 따라서 64개의 에코로 $128{\times}128$의 고해상도 single shot 영상을 얻을 수 있다. 또한 k-space 데이터의 순서를 시간 축에서 조절하여 강한 $T_2$ 대조도를 갖는 영상을 얻을 수 있다 Eddy current의 영향으로 phase encoding 방향으로 잔류 경사자계가 있을 경우 측정된 데이터들은 k-space에서 이동이 되며 , 이것은 재구성 영상에 심각한 문제점을 초래하게 된다. 본 논문에서는 pre-scan에서 얻은 기준 데이터와 dc에 해당하는 에코간의 상관도를 측정하여 이동을 추정하며, 초기의 phase encoding gradient의 크기를 조정하여 이러한 이동을 제거한다. 결과 : 제안한 $T_2$-weighted half courier EPI 영상기법을 1.0 Tesla 전신 MRI 시스템에 적용하였다. 실험 조건은 single shot으로 TR은 무한대이고, TE는 72ms와 96ms로 설정하였다. 제안한 영상기법을 이용하여 single scan으로 강한 $T_2$ 대조도를 갖는 128x128의 고해상도 EPI 영상을 얻을 수 있었다. 결론 : 제안한 Half Fourier기법을 이용하여 기존의 $64{\times}64$ 영상보다 해상도를 높인 $128{\times}128$ EPI영상을 single scan으로 얻을수 있었으며, 에코의 적절한 배치를 통해 임상에서 널리 사용되는 $T_2$ 대조도를 얻을 수 있었다. 제안한 방법은 특별한 하드웨어의 추가 없이, 펄스 시퀀스와 tuning 및 재구성 알고리즘 등의 소프트웨어적인 방법만으로 구현이 가능하여 많은 임상 응용이 기대된다.

  • PDF

자기공명 확산강조영상검사 시 영상왜곡 감소에 관한 연구 (The Study on Reduction of Image Distortion by using Single-Shot Turbo Spin Echo in Brain Stem Diffusion MRI)

  • 최관우;이호범;나사라;유병규;손순룡
    • 한국방사선학회논문지
    • /
    • 제10권4호
    • /
    • pp.279-284
    • /
    • 2016
  • 본 연구는 DWI 검사 시 자화율 차이로 인해 뇌줄기에 발생하는 영상의 왜곡을 새로운 SS-TSE를 적용하여 감소시키고자 하였다. 연구방법은 2015년 7월부터 동년 9월까지 DWI 검사를 검사한 30명을 대상으로, 기존의 SS-EPI 기법과 새로운 SS-TSE를 적용하여 기법에 따른 뇌줄기의 왜곡과 오차율을 비교평가 하였다. 연구결과, 새로운 SS-TSE 적용 시 왜곡이 감소된 것을 볼 수 있으며, 오차율 또한 b0 영상은 2.4%(11.1%에서 8.7%), b1000 영상은 1.2%(11.4%에서 10.1%) 감소하는 것을 볼 수 있었다. 결론적으로, 뇌줄기의 DWI 검사 시 본 연구의 SS-TSE를 이용하면 기존 기법 사용 시 발생하는 영상의 왜곡을 감소시킬 수 있어 진단적 가치가 높은 영상을 획득할 수 있다.

3.0 Tesla 자기공명영상시스템에서 고 해상도 나선주사영상 (High-resolution Spiral-scan Imaging at 3 Tesla MRI)

  • 김판기;임종우;강승원;조상흠;전수열;임헌진;박호종;오승준;이흥규;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • 제10권2호
    • /
    • pp.108-116
    • /
    • 2006
  • 목적 : 3.0 Tesla 고 자장에서 고 해상도 나선주사영상을 수행하였다. 나선주사영상은 초고속 영상기법의 하나로서, Echo Planar Imaging(EPI)에 비하여 eddy current 가 작게 발생하고, 경사자계 파형의 기울기가 완만하여 상대적으로 낮은 slew rate 를 가진 경사자계시스템으로 구현이 가능한 장점이 있다. 또한 고 자장 영상에서 고속스핀에코(Fast Spin Echo: FSE) 등의 rf 에코 기반의 고속영상방법에서 심각하게 대두되는 SAR 문제가 근원적으로 발생하지 않는 장점이 있어 고 자장에서의 초고속영상방법으로 주목을 받고 있다. 본 연구에서는 3.0 Tesla 에서 나선주사방식으로 고 해상도 영상을 얻어 고 자장 MRI에서 나선주사영상기법의 다양한 응용 가능성을 살펴보고자 한다. 대상 및 방법 : 3 Tesla 전신 자기 공명 영상 시스템에서 다양한 해상도의 나선주사영상 방법을 개발하였다. 고차(higher-order) shimming 을 통하여 영상의 화질을 개선하였고, 해상도에 맞게 interleaves 수를 조절하였다. 스핀에코 와 gradient에코 기반 나선주사영상방법을 구현하였고, 에코 time 과 repetition time, rf 회전 각도를 조절하여 영상의 대조도(contrast)와 신호대잡음비를 조절하였다. 결과 : 3 Tesla 전신 자기 공명 영상 시스템에서 나선 주사 방법을 이용하여 다양한 해상도의 영상을 얻었다. 고 자장에서 주 자장의 불균일도(inhomogeneity) 의 절대 크기가 커지기 때문에 이를 줄이기 위한 shimming 이 더욱 중요해진다. 한번의 스캔으로 axial, sagittal, coronal 방향의 불균일도 map을 구하여 spherical harmonics 분석으로 고차 shimming을 하였다. 팬텀과 in-vivo 두부 영상에서 single shot 나선주사 영상으로 $100{\times}100$ 정도의 영상과 6-12 정도의 interleaves 를 적용하여 $256{\times}256$ 의 고 해상도 영상을 얻을 수 있었다. 결론 : 신호대잡음비의 향상과 스펙트럼의 분리, 뇌기능영상에서 BOLD 효과 향상 등으로 고자장 영상에 대한 관심이 높아지고 있다. 그러나 고 자장 영상에서의 rf field 에 의한 SAR 증가는 중요한 제한 요소로 부각되고 있다. 나선주사영상은 SAR 문제가 근원적으로 발생하지 않고, EPI에 비하여 하드웨어 요구 조건이 낮아 고 자장에서의 고속영상방법으로 적합하다. 본 논문에서는 고차 shimming 을 통하여 불균일도를 개선하고, single shot 과 interleaving 을 적용한 multi-shot 나선주사영상 기법으로 $100{\times}100$에서 $256{\times}256$의 고해상도 영상을 얻어 고 자장에서 초고속영상기법으로 다양한 적용 가능성을 보였다.

  • PDF

뇌줄기 확산강조 자기공명영상검사 시 뒤틀림을 줄이기 위한 SS-TSE 기법의 신호대잡음비 연구 (The Study on Signal to Noise Ratio of Single-Shot Turbo Spin Echo to Reduce Image Distortion in Brain Stem Diffusion MRI)

  • 구노현;이호범;최관우;손순룡;유병규
    • 한국방사선학회논문지
    • /
    • 제10권4호
    • /
    • pp.241-246
    • /
    • 2016
  • 본 연구는 뇌줄기 확산강조영상검사 시 뒤틀림을 줄이기 위한 SS-TSE 기법의 신호대잡음비 감소를 수치적으로 정량화하여, 낮은 신호대잡음비로 인한 SS-TSE 기법의 문제점을 지적하고자 하였다. 연구방법은 2015년 7월부터 10월까지 뇌줄기 확산강조영상검사를 검사한 35명을 대상으로 하였으며, 기존의 SS-EPI 기법과 SS-TSE 기법을 적용하여 기법별 숨뇌의 신호대잡음비을 비교하였다. 연구결과 b=0 영상의 신호대잡음비는 새로운 SS-TSE 기법($314.41{\pm}42.96$) 적용 시 SS-EPI 기법($514.84{\pm}48.97$) 보다 38.9% 감소하였으며, b=1,000 영상의 경우도 SS-TSE 기법($117.33{\pm}14.04$) 적용 시 SS-EPI 기법($208.65{\pm}25.70$) 보다 43.8% 감소하였다. 결론적으로, 미세 병변을 진단하기 위한 뇌줄기의 확산강조 자기공명영상 검사 시 뒤틀림을 줄이기 위해 SS-TSE 기법을 적용할 경우 신호대잡음비가 저하됨으로 기존의 SS-EPI 기법이나 MS-EPI 기법을 병행하여 검사하는 것이 진단의 정확성을 높일 수 있으리라 사료된다.

In vivo Visualization of Human White Matter Tract by Diffusion Tensor Imaging Fiber Tractography (DTI-FT)

  • Lee, Seung-Koo;Kim, Dong-Ik
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2002년도 제7차 학술대회 초록집
    • /
    • pp.85-85
    • /
    • 2002
  • Purpose: To evaluate the white matter fiber connectivity of normal human using diffusion tensor MRI. Method: Normal young healthy volunteers (2 women and 1 man) and 3 brain tumor patients participated in this study. All studies were performed using a 1.5T Philips Gyroscan Intern system. Diffusion weighted imaging was performed using single-shot echo planar imaging, with navigator echo phase correction and SENSE. Diffusion weighting was performed along six independent axes, using diffusion weighting of b=800s/$\textrm{mm}^2$. 128matrix, 23cm FOV, 2.5mm slice thickness were used for Imaging parameters. Data were processed on a Window-2000 PC equipped with IDL and PRIDE (Philips Medical System). Corticospinal tract was traced from mid-pons level via posterior limb of internal capsule. Corpus callosum, cerebellar peduncles and frontal fibers were traced by fiber tractography.

  • PDF

Diffusion Tensor MRI and Fiber Tractography: Evaluation of Developmental CNS Anomaly: Preliminary Results

  • Lee, Seung-Koo;Kim, Dong-Ik
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2002년도 제7차 학술대회 초록집
    • /
    • pp.86-86
    • /
    • 2002
  • Purpose: To evaluate the white matter fiber configuration in various developmental CNS anomaly 대상 및 방법: Jubert Syndrome, congenital schizencephaly, callosal agenesis and hemiplegic cerebral palsy patients were evaluated by diffusion tensor MRI. All studies were performed using a 1.5T Philips Gyroscan Intern system. Diffusion weighted imaging was performed using single-shot echo planar imaging, with navigator echo phase correction and SENSE. Diffusion weighting was performed along six independent axes, using diffusion weighting of b=600s/$\textrm{mm}^2$. 128 matrix/zero filled to 256, 23cm FOV, 3mm slice thickness were used for imaging parameters. Data were processed on a Window-2000 PC equipped with IDL and PRIDE (Philips Medical System).

  • PDF

일회 영상으로 확산텐서 자기공명영상을 얻을 수 있는 다편-다에코 펄스 경사자장 스핀에코(MePGSE) 시퀀스의 초기 결과 (Multi-slice Multi-echo Pulsed-gradient Spin-echo (MePGSE) Sequence for Diffusion Tensor Imaging MRI: A Preliminary Result)

  • 장건호
    • 한국의학물리학회지:의학물리
    • /
    • 제18권2호
    • /
    • pp.65-72
    • /
    • 2007
  • 대부분의 임상용 자기공명영상 장치에서 확산텐서(difiusion tensor) 영상을 얻기 위하여 에코플렌(EPI) 스핀에코(spin-echo) 시퀀스를 사용한다. 하지만 이 영상법은 자화감수성에 매우 예민한 단점이 있다. 따라서 본 연구의 목적은 자화감수성에 의해 발생하는 영상의 변질을 최소화하면서 확산텐서를 한번에 얻을 수 있는 시퀀스를 개발하는데 있다. 모든 확산 텐서 성분을 한번에 얻기 위하여 다편(multi-slice) 8에코 스핀에코 시퀀스(MePGSE)가 개발되었다. 모든 180도 펄스는 기존에 사용된 방법과는 달리 선택된(slice selective) 경사자장을 이용하였다. 처음 7개의 에코 영상은 확산텐서 영상을 위하여 사용하였고, 마지막 에코 영상에서는 영상을 얻는 경사자장은 사용하지 않고 남아있는 자화를(residual magnetization) 최소화하기 위하여 삼차원 경사자장(crusher gradients)만을 사용하였다. 따라서 6개의 텐서 성분을 단 한번의 실험에 의하여 얻을 수 있었다. 이 시퀀스를 사용하여 물과 수박을 이용하여 실험을 하였으며 물에서의 확산 값이 기존에 출판된 값과 유사하게 나타나 본 연구에서 MePGSE 시퀀스의 신뢰를 가질 수 있었다.

  • PDF

Review of Recent Advancement of Ultra High Field Magnetic Resonance Imaging: from Anatomy to Tractography

  • Cho, Zang-Hee
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권3호
    • /
    • pp.141-151
    • /
    • 2016
  • Purpose: Advances of magnetic resonance imaging (MRI), especially that of the Ultra-High Field (UHF) MRI will be reviewed. Materials and Methods: Diffusion MRI data was obtained from a healthy adult young male of age 30 using a 7.0T research MRI scanner (Magnetom, Siemens) with 40 mT/m maximum gradient field. The specific imaging parameters used for the data acquisition were a single shot DW echo planar imaging. Results: Three areas of the imaging experiments are focused on for the study, namely the anatomy, angiography, and tractography. Conclusion: It is envisioned that, in near future, there will be more 7.0T MRIs for brain research and explosive clinical application research will also be developed, for example in the area of connectomics in neuroscience and clinical neurology and neurosurgery.

뇌 운동피질의 기능적 영상: 고식적 Gradient Echo기법과 EPI기법간의 비교 (Functional MR Imaging of Cerbral Motor Cortex: Comparison between Conventional Gradient Echo and EPI Techniques)

  • 송인찬
    • Investigative Magnetic Resonance Imaging
    • /
    • 제1권1호
    • /
    • pp.109-113
    • /
    • 1997
  • 목적: 고식적인 spoiled gradient echo(SPGR) 기법과 EPI기법간의 뇌의 운동피질에 대한 기능적 영상의 차이를 평가하고자 하였다. 대상 및 방법: 5명의 정상 성인을 대상으로 1.5T 자기공명영상기기에서 SPGR기법(TR/TE/flep angle=50ms / 40ms / $30^{\circ}$, FOV=300mm, matrix $size=256{\times}256$, 단면두께=5mm)과 기법(TR / TE / flip angle=3000ms / 40ms / $90^{\circ}$, FOV=300mm, matrix $size=128{\times}128$, 단면두께=5mm)을 사용하여 MR 에이터를 얻었다. EPI기법의 경우, 총 6개의 단면에 대해 총 960개의 영상을 얻었고 SPGR 기법 겨우, 위 6개의 단면 중 운동중추영역이 포함된 한 단면에 대해 총 160개의 영상을 얻었다. 사용된 paradigm은 각각 8번의 휴지 기간과 활성 기간으로 구성되었고 활성기간동안에 시행된 작업은 오른손 손가락의 쥠과 펼침 운동이었다. 뇌의 활성영역을 국소화 하기 위해 사용된 통게적인 처리방법은 cross-correlation 방법이었다. 두 기법의 활성화 영상에 대해 활성 영역에서의 휴지 기간과 활성 기간간의 신호 크기의 변화와 연속적인 MR 데이터의 신호 대 잡음비의 측정, 그리고 활성 영역의 위치와 그 범위를 비교 분석하였다. 결과: 두 기법 모두에서 운동중추영역인 전운동피질이 잘 관찰되었다. 휴지 기간과 활성 기간간의 신호 크기의 변화는 두 기법간의 유의한 차이가 없었다. 그러나, 연속적인 MR 데이터의 신호 대 잡음비에 있어서는 EPI 기법이 SPGR 기법보다 약 2배 높았다. 또한, 활성 영역에 있어서 EPI 기법이 SPGR기법보다 낮은 쪽으로의 p값의 분포를 보여 주었다. 결론: 본 연구는 운동중추영역에 대한 뇌의 기능적 영상을 얻는 데에 있어서 두 기법 모두 유용함을 보여주었다. 그러나, EPI 기법에서 얻을 수 있는 높은 신호 감도 특성에 의해 EPI 기법이 SPGR 기법보다 뇌의 기능적 영역에 대한 더 정확한 정보를 제공하는 장점을 지닌다.

  • PDF