• 제목/요약/키워드: Single-photon emission

검색결과 189건 처리시간 0.019초

Cross Talk Experiment with Two-element CdTe Detector and Collimator for BNCT-SPECT

  • Manabe, Masanobu;Ohya, Ryosuke;Saraue, Nobuhide;Sato, Fuminobu;Murata, Isao
    • Journal of Radiation Protection and Research
    • /
    • 제41권4호
    • /
    • pp.328-332
    • /
    • 2016
  • Background: Boron Neutron Capture Therapy (BNCT) is a new radiation therapy. In BNCT, there exists some very critical problems that should be solved. One of the severest problems is that the treatment effect cannot be known during BNCT in real time. We are now developing a SPECT (single photon emission computed tomography) system (BNCT-SPECT), with a cadmium telluride (CdTe) semiconductor detector. BNCT-SPECT can obtain the BNCT treatment effect by measuring 478 keV gamma-rays emitted from the excited state of $^7Li$ nucleus created by $^{10}B(n,{\alpha})$ $^7Li$ reaction. In the previous studies, we investigated the feasibility of the BNCT-SPECT system. As a result, the S/N ratio did not meet the criterion of S/N > 1 because deterioration of the S/N ratio occurred caused by the influence of Compton scattering especially due to capture gamma-rays of hydrogen. Materials and Methods: We thus produced an arrayed detector with two CdTe crystals to test cross talk phenomenon and to examine an anti-coincidence detection possibility. For more precise analysis for the anti-coincidence detection, we designed and made a collimator having a similar performance to the real BNCT-SPECT. Results and Discussion: We carried out experiments with the collimator to examine the effect of cross talk of scattering gamma-rays between CdTe elements more practically. As a result of measurement the coincidence events were successfully extracted. Conclusion: We are now planning to carry out evaluation of coincidence rate from the measurement and comparison of it with the numerical calculations.

Biodistribution of 99mTc Tricarbonyl Glycine Oligomers

  • Jang, Beom-Su;Lee, Joo-Sang;Rho, Jong Kook;Park, Sang Hyun
    • Toxicological Research
    • /
    • 제28권4호
    • /
    • pp.235-240
    • /
    • 2012
  • $^{99m}Tc$ tricarbonyl glycine monomers, trimers, and pentamers were synthesized and evaluated for their radiolabeling and in vivo distribution characteristics. We synthesized a $^{99m}Tc$-tricarbonyl precursor with a low oxidation state (I). $^{99m}Tc(CO)_3(H_2O)_3^+$ was then made to react with monomeric and oligomeric glycine for the development of bifunctional chelating sequences for biomolecules. Labeling yields of $^{99m}Tc$-tricarbonyl glycine monomers and oligomers were checked by high-performance liquid chromatography. The labeling yields of $^{99m}Tc$-tricarbonyl glycine and glycine oligomers were more than 95%. We evaluated the characteristics of $^{99m}Tc$-tricarbonyl glycine oligomers by carrying out a lipophilicity test and an imaging study. The octanol-water partition coefficient of $^{99m}Tc$ tricarbonyl glycine oligomers indicated hydrophilic properties. Single-photon emission computed tomography imaging of $^{99m}Tc$-tricarbonyl glycine oligomers showed rapid renal excretion through the kidneys with a low uptake in the liver, especially of $^{99m}Tc$ tricarbonyl triglycine. Furthermore, we verified that the addition of triglycine to prototype biomolecules (AGRGDS and RRPYIL) results in the improvement of radiolabeling yield. From these results, we conclude that triglycine has good characteristics for use as a bifunctional chelating sequence for a $^{99m}Tc$-tricarbonyl-based biomolecular imaging probe.

Encephalo-duro-arterio-synangiosis(EDAS) using Occipital Artery in Children with Moyamoya Disease

  • Choi, In-Jae;Hong, Seok-Ho;Cho, Byung-Kyu;Wang, Kyu-Chang;Kim, Seung-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • 제38권6호
    • /
    • pp.413-418
    • /
    • 2005
  • Objective : Although an encephaloduroarteriosynangiosis procedure using the superficial temporal artery [STA-EDAS] is an effective indirect bypass method in children with moyamoya disease[MMD], there is still a need for an additional bypass operation that can cover the area of the posterior circulation. The goal of this study is to evaluate the efficacy of the EDAS procedure using the occipital arteries [OA-EDAS]. Methods : From August 2003 to April 2004, We performed OA-EDAS in sixteen patients with MMD who have a circulatory insufficiency in the territory of the posterior cerebral artery[PCA]. The medical records were reviewed retrospectively. The surgical outcomes, including the changes in neurological status and imaging studies, with the degree of neovascularization on the cerebral angiogram, and the hemodynamic changes on single-photon emission computed tomography[SPECT], were analyzed. Results : These 16 children consisted of 5 boys and 11 girls aged 2 to 9 years. The clinical outcome of their PCA symptoms, such as visual transient ischemic attacks[TIAs] or visual field defect, was favorable in 14 patients of 16. Nine patients of 11 who underwent follow up magnetic resonance imaging[MRI] showed favorable MRI changes. On angiogram most of the patients exhibited good or fair revascularization of the PCA territory [7 of 8]. The hemodynamic changes on SPECT in the PCA territory after surgery showed improved vascular reserve in 13 of the 16 territories. Conclusion : OA-EDAS is a safe and efficacious revascularization procedure in patients with MMD who have compromised cerebral perfusion in PCA territory, or with visual TIAs.

산업용 SPECT의 검출기 개수가 영상 해상도에 미치는 영향 평가 (Effect of the Number of Detectors on Performance of Industrial SPECT)

  • 박장근;김찬형;김종범;문진호;정성희
    • 방사선산업학회지
    • /
    • 제5권4호
    • /
    • pp.325-330
    • /
    • 2011
  • To predict the details of flow in industrial process unit, single photon emission computed tomography (SPECT) is a promising technique. Recently, industrial SPECT based on medical system has developed by researchers of the Korea Atomic Energy Research Institute (KAERI) and Hanyang University. In the present study, to confirm the effect of the number of detectors on image quality, and determine the optimal number of detectors in industrial SPECT, industrial SPECT system with various geometries were evaluated by the Monte Carlo simulation. CsI(Tl) detectors ($12mm{\times}12mm{\times}20mm$) with collimators (the geometric resolution of collimator $R_g$ was 4 cm at the center of the 30 cm diameter cylindrical vessel object) were modeled in a hexagonal array, and the point sources of $^{99m}Tc$, $^{68}Ga$, and $^{137}Cs$ were simulated at the center of the cylindrical vessel object using the MCNPX code. Then, the reconstruction images of each geometry were reconstructed using the expectation maximization (EM) algorithm. In this study, the reciprocity theorem was used to improve computation time required for system matrix of the EM algorithm. The result shows that the resolution of the reconstructed image was significantly improved by increasing the number of detectors in industrial SPECT system and more than 60 detectors will be required for the resolution of the reconstructed image.

A Study on Comparison of Cardiac Ejection Fraction Values Measured in Myocardium SPECT and Cine MRI

  • Han, Jung-Seok;Dong, Kyung-Rae;Park, Yong-Soon;Chung, Woon-Kwan;Cho, Jae-Hwan;Cho, Young-Kuk
    • Journal of Magnetics
    • /
    • 제17권3호
    • /
    • pp.229-232
    • /
    • 2012
  • This study examined the correlation between MR cine and myocardium Single-photon emission computed tomography (SPECT) by comparing the measured cardiac ejection fractions. The usefulness of cardiac MRI was also evaluated. Ten patients (8 men, 2 women and average age of 58.6 years), who underwent a myocardium SPECT scan and cardiac cine MRI scan among patients who visited the hospital for the chief complaint of cardiac disorder from June 1, 2010 to February 10, 2011, were enrolled in this study. The cardiac ejection fraction was calculated from the images obtained in both scans. The data was used to examine the correlation. The regression equation the cardiac ejection fraction values of the 10 patients obtained in myocardium SPECT and MRI cine was Y = 1.12X-8.91 ($R^2$ = 0.78, significance of F = 0.001639, and confidence level of 95%). The results were significant when the cardiac ejection fraction obtained from MRI cine was compared with that obtained from myocardium SPECT. Overall, a cardiac examination using MRI enables an investigation of not only the ejection fraction but also the ED and ES volumes, stroke volume, wall thickness, and wall thickening in a higher spatial resolution despite the examination being conducted once. This examination is believed to be very useful for diagnosing patients with cardiac disease.

감마카메라 영상에서 분해능 향상을 위한 Xact-bone의 유용성 평가 (Usefulness of Xact-bone for the Resolution Advancement of Gamma Camera Image)

  • 김종필;윤석환;임정진;우재룡
    • 핵의학기술
    • /
    • 제15권2호
    • /
    • pp.30-35
    • /
    • 2011
  • 현재 분해능 향상을 위한 프로그램인 Wide beam reconstruction (WBR: UltraSPECT, Israel) 을 사용하고 있다. WBR에 속해있는 Xact-Bone은 Planar영상과 Single photon emission computed tomography (SPECT) 영상의 분해능과 대조도를 향상시켜 상당한 영상의 질 향상에 도움을 준다고 보고 되어있다. 본 연구는 Xact-Bone의 임상적용에 대한 유용성을 알아보고자 한다. Xact-Bone에서의 유용성 평가는 분해능 평가와 Contrast Ratio를 비교분석하였다. Planar영상에서의 분해능 평가는 capillary tube를 이용하여 Full width at half maximum (FWHM)을 구하였고, Contrast Ratio분석은 2010년 1월부터 2010년 10월까지 bone scan 검사를 위해 본원에 내원한 50명의 환자 Xact-Bone의 사용 전 후 영상에서 Bone and Soft tissue (B/S) ratio 값을 비교 평가하였다. SPECT영상에서의 분해능 평가는 Triple Line Source Phantom을 이용하여 FWHM을 구하였고, Contrast Ratio 비교 분석은 NEMA IEC Body Phantom과 Standard Jaszczak Phantom을 이용하여 획득한 영상을 각각 Filtered backprojection (FBP), Orderd subset expectation maximization (OSEM), Xact-Bone으로 재구성하여 비교하였다. Planar영상에서의 유용성 평가는 capillary tube를 이용한 실험결과, FWHM은 기존의 Planar영상보다 WBR의 Xact-Bone 프로그램을 이용한 재구성 영상에서 약 20% 향상되었으며, B/S ratio값도 약 15% 향상되었다. SPECT영상의 유용성 평가는 Triple line Source Phantom을 이용한 실험결과, FWHM은 Xact-Bone이 FBP, OSEM 기법보다 각각 20%, 10% 향상되었다. 또한 NEMA IEC body Phantom을 이용한 Contrast Ratio 비교분석결과 각각 20%, 10% 향상되었고, Standard Jaszczak Phantom을 이용한 Contrast Ratio 비교분석 결과는 각각 90%, 50% 향상되었다. WBR의 Xact-bone 프로그램을 이용한 Planar 영상에서는 사용하지 않은 경우와 비교하였을 경우 상당한 영상의 분해능과 Contrast Ratio가 향상됨을 알 수 있었고, SPECT영상에서 기존의 FBP, OSEM 영상재구성 방법보다 분해능, Contrast Ratio가 향상됨을 알 수 있었다. 이에 WBR의 Xact-Bone을 이용함으로써 영상의 질적 향상이 기대되는 바이다. 하지만, 새로운 소프트웨어 도입시 병원의 특성에 맞는 protocol 과 임상적용이 필요하다고 사료된다.

  • PDF

급성 심근경색 환자의 Tc-99m Tetrofosmin 심근 관류 지연영상에서 관찰되는 역재분포 현상의 임상적 의의 (Clinical Significance of Reverse Redistribution Phenomenon on Delayed Tc-99m Tetrofosmin Myocardial Perfusion Imaging in Patients with Acute Myocardial Infarction)

  • 박순아;김대응;김창근;정진원;김남호;김경호
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제43권2호
    • /
    • pp.112-119
    • /
    • 2009
  • 목적: Tc-99m tetrofosmin은 일반적으로 재분포 하지 않는 것으로 알려져 있으나 최근 일부 연구에서 Tc-99m tetrofomin의 재분포 현상이 보고 되고 있다. 본 연구는 재관류 치료를 받은 급성 심근경색 환자의 Tc-99m tetrofosmin 심근 관류 지연영상에서 역재분포 현상을 관찰하고 이에 대한 정량분석 및 추적 검사를 통해 역재분포 현상의 임상적 의의에 대하여 알아보고자 하였다. 대상 및 방법: 급성 심근경색으로 관동맥 중재술을 시행한 67명(남자 46명, 여자 21명, 평균연령 $62{\pm}12.9$세)을 대상으로 게이트 Tc-99m tetrofosmin SPECT영상을 얻었다. 휴식기 조기 영상은 주사 후 40분째 얻었고 부하 후 지연기 영상은 3시간째 촬영하였다. 심근은 단축 영상을 주로 하여17개 분절로 나누어 분석하였고 심근의 혈류감소 정도와 범위, 국소심근벽 운동, 심근벽 두께는 단축 영상을 주로 하여 정상에서 결손까지 4등급으로 분류하여 분절 점수를 매겼다(0: 정상, 1: 약간 감소, 2: 심한 감소, 3: 결손). 조기 영상을 지연기 영상과 비교하여 지연기 영상에서 2점 이상으로 악화되는 분절을 역재분포가 있는 분절로 정의하였다. 대상 환자들은 9개월 후 관동맥 조영술과 게이트 Tc-99m tetrofosmin 심근 관류를 시행하였으며 역재분포가 있었던 경우와 없었던 경우로 나누어 관동맥 재협착 유무와 심근의 혈류감소 정도와 범위, 국소 심근벽 운동, 심근두께. 구혈률을 비교 분석하였다. 결과: 관동맥 중재술을 시행한 급성 심근경색 환자에서Tc-99m tetrofosmin의 역재분포 현상은67명 중 43명으로 64%였으며 391개 분절 중에서는 100개로 31%에서 관찰되었다 심근 혈류의 감소와 범위, 국소 심근벽 운동의 이상과 심근벽 두께의 감소, 구혈률은 역재분포가 있는 심근에서 더 심하였으며 통계학적 의미를 가졌다. 9개월 후 추적검사에서 관동맥 재협착의 발생은 역재분포의 유무에 따른 차이를 보이지 않았지만 Tc-99m tetrofosmin 심근관류 SPECT에서 역재분포를 보이는 심근이 혈류감소의 정도와 범위, 국소 심근벽운동의 이상, 심근 두께의 회복은 유의한 결과를 보였다. 결론: Tc-99m tetrofosmin지연기 영상에서 보이는 역재분포는 관동맥 중재술을 시행한 환자에서 관찰될 수 있으며 재혈관화 된 심근의 생존 가능성과 좌심실 기능의 회복을 예측하는데 추가적인 정보를 제공할 수 있을 것으로 사료되어 Tc-99m tetrofosmin 심근관류 영상의 임상적 유용성을 향상 시킬 수 있을 것으로 기대된다.

Brain SPECT 영상의 Attenuation Correction 방법들에 대한 비교 (Comparison of Attenuation Correction Methods for Brain SPECT Ima)

  • 조진우;김창호;나수경;이귀원
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.120-125
    • /
    • 2012
  • 이 연구의 목적은 Brain SPECT (Single Photon Emission Computed Tomography)의 Non-attenuation correction (AC-non) 영상에 대한 attenuation correction(AC) 방법 중 Chang's method와 CT based attenuation correction(AC-CT) 사이의 count를 비교하기 위함이다. phantom study는 증류수로 채워진 hoffman 3D phantom에 $^{99m}Tc$ 37Mbq을 투여하였고, patient study는 normal volunteer에 $^{99m}Tc$-HMPAO 750Mbq를 정맥주입하고 Siemens사의 Symbia T6로 Brain SPECT 영상을 획득하였고 뇌 정량 분석을 하였다. 각각의 방법들을 적용한 transverse image는 같은 위치에서 재구성 되었으며 각각 10, 20, 30번째 slice에서 6개의 region of interest(ROI)를 그려 AC-non 과 AC-CT 그리고 Chang's method의 count를 비교하였다. phantom study에서 AC-non, AC-CT, Chang's method의 각각 평균 count는 $4606.8{\pm}511.3$, $16794.6{\pm}2429.4$, $8752.6{\pm}896.5$이었으며 patient study에서 $5460.8{\pm}519.6$, $15320{\pm}1171.6$, $12795{\pm}1422.1$이었다. phantom study에서 AC-CT와 AC-non 사이의 비는 3.70이고 Chang's method와 AC-non 사이의 비는 1.92였으며 patient study에서는 각각 2.85, 2.38이었다. 우리는 이 연구를 통하여 AC-CT가 Chang's method보다 더 높은 AC을 해준다는 걸 알 수 있었다. 그리고 Chang's method는 patient study에서의 AC 값이 phantom study에서의 AC값보다 더 높다는 것을 알 수 있었다. brain SPECT/CT를 시행하는 경우 scatter correction을 같이 시행하고 bone에 의한 감쇠 정보를 반영할 수 있는 AC-CT가 chang's method보다 정확하다 할 수 있겠다.

  • PDF

족삼리-해계 전침치료가 정상인의 국소 뇌혈류에 미치는 영향 -Brain SPECT와 SPM을 이용하여- (Effect of ST 36-ST 41 Electro-acupuncture on Regional Cerebral Blood Flow in Normal Volunteers Evaluated by $^{99m}Tc$-ECD SPECT)

  • 문상관;민인규;박성욱;정우상;박정미;고창남;조기호;배형섭;김영석;김덕윤
    • 대한한의학회지
    • /
    • 제31권1호
    • /
    • pp.130-137
    • /
    • 2010
  • Objectives: So far it has been reported that acupuncture increases cerebral blood supply and stimulates the functional activity of brain nerve cells. Previous studies have demonstrated that frequently used electro-acupuncture (EA) therapies for stroke increased regional cerebral blood flow (rCBF) in normal volunteers. Though ST 36-ST 41 EA is another prevailing therapy for stroke, there had been no report about its effect on rCBF. This study was to evaluate the effect of ST 36-ST 41 EA on rCBF in normal volunteers using single photon emission computed tomography (SPECT) and statistical parametric mapping (SPM). Methods: In the resting state, $^{99m}Tc$-ECD brain SPECT scans were performed on 10 normal volunteers (5 males, 5 female, mean age $23.6{\pm}0.5$ years). On the other study day, 7 days after the resting examination, 15 minutesEA were applied at ST 36 and ST 41 on the right side of the subjects. Immediately after ST36-ST41 EA, the second SPECT images were obtained in the same manner as the resting state. Significant increases and decreases of rCBF after EA were estimated by comparing their SPECT images with those of the resting state using paired t statistics at every voxel, which were analyzed by SPM with a threshold of p = 0.01, uncorrected (extent threshold: k=100 voxels). Results: EA applied at the right ST36-ST41 significantly increased rCBF in the right inferior parietal lobule (Brodmann area [BA] 40), right retrosubicular area (BA 48), left inferior parietal lobule (BA 40), left middle temporal gyrus (BA 21), left fusiform gyrus (BA 37), left inferior parietal lobule (BA 39), left inferior temporal gyrus (BA 20), and left somatosensory association cortex (BA 7). However, right ST36-ST41 EA significantly decreased rCBF in the right parahippocampal gyrus (BA 35), right cerebellum, left frontopolar area (BA 10), left orbitofrontal area (BA 11), left dorsolateral prefrontal cortex (BA 9), and left dorsal anterior cingulate cortex (BA 32). Conclusions: These results demonstrate that rightST36-ST41 EA increased rCBF prominently in both inferior parietal lobule (BA 40) and right retrosubicular area (BA 48), which suggest that there be correlation between specific EA and corresponding rCBF.

$^{99m}Tc$-HMPAO SPECT를 이용한 알쯔하이머병의 진단에서 허혈성 뇌병변이 미치는 영향 (Influence of Ischemic Lesions on $^{99m}Tc$-HMPAO SPECT Findings in the Diagnosis of Alzheimer's Disease)

  • 이경한;이명철;이동수;권준수;김종호;정준기;우종인;고창순
    • 대한핵의학회지
    • /
    • 제28권3호
    • /
    • pp.282-292
    • /
    • 1994
  • 본 연구에서는 $^{99m}Tc$-HMPAO SPECT를 이용한 AD의 진단에서 허혈성 뇌병변의 유무와 대조군의 선정방법이 진단성적에 미치는 영향을 조사하기 위하여 지역주민을 대상으로 진단된 PAD군 11례와 연령을 맞춘 대조군 12례에서 SPECT를 시행하여 국소 혈류비를 분석하였다. MRI 소견을 조사한 결과 PAD군의 27%(3/11)와 대조군의 25%(3/12)에 유의한 뇌허혈 또는 경색 병변이 관찰되었다. 뇌병변의 유무와 관계없이 두군을 비교한 결과 측두엽이나 두정엽에 평균혈류비의 유의한 차이가 없었으며 두군을 신뢰성있게 감별할 만한 특징적인 혈류양상을 발견하지 못하였다. 그러나 뇌허혈병변이 있는 자를 대조군에서 제외시켰을 때 두군의 측두엽 및 두정엽 혈류비의 차이가 증가하였다. 또 별도로 설정한 건강한 대조군과 비교한 결과 같은 부위의 혈류비에 현저한 차이가 관찰되었다. 이상의 결과로 뇌혈류 SPECT에 의한 AD의 진단성적은 연구대상의 선정에 의해 영향을 받으며 특히 허혈성 뇌병변의 유무는 연구결과에 많은 영향을 미친다고 생각되었다. 향후 허혈성 뇌병변에 의한 영향을 해결하기 위해 SPECT 영상을 방사선학적 검사와 함께 평가하는 방법에 대한 연구가 필요하다고 사료되었다.

  • PDF