• Title/Summary/Keyword: Single-phase PWM inverters

Search Result 40, Processing Time 0.019 seconds

A Modified Single-Phase Transformerless Z-Source Photovoltaic Grid-Connected Inverter

  • Liu, Hongpeng;Liu, Guihua;Ran, Yan;Wang, Gaolin;Wang, Wei;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1217-1226
    • /
    • 2015
  • In a grid-connected photovoltaic (PV) system, the traditional Z-source inverter uses a low frequency transformer to ensure galvanic isolation between the grid and the PV system. In order to combine the advantages of both Z-source inverters and transformerless PV inverters, this paper presents a modified single-phase transformerless Z-source PV grid-connected inverter and a corresponding PWM strategy to eliminate the ground leakage current. By utilizing two reversed-biased diodes, the path for the leakage current is blocked during the shoot-through state. Meanwhile, by turning off an additional switch, the PV array is decoupled from the grid during the freewheeling state. In this paper, the operation principle, PWM strategy and common-mode (CM) characteristic of the modified transformerless Z-source inverter are illustrated. Furthermore, the influence of the junction capacitances of the power switches is analyzed in detail. The total losses of the main electrical components are evaluated and compared. Finally, a theoretical analysis is presented and corroborated by experimental results from a 1-kW laboratory prototype.

Design of Single Loop Output Voltage Controller for 3 Phase PWM Inverterl (3상 PWM 인버터의 단일루프 전압제어기 설계)

  • 곽철훈;최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.6
    • /
    • pp.561-568
    • /
    • 2003
  • There arc two ways in the output voltage control method in PWM inverters. One Is double loop voltage control composed of inner current control loop and outer voltage control loop.'rho other is single loop voltage control method composed of voltage control loop only. It's characteristics shows lower performance in case of high output impedance than double loop voltage control. However, in case of low output impedance, it shows good control performance in all load ranges than double loop voltage control. In this paper, the rule and the gain of single loop voltage control have been developed analytically and these were verified through computer simulation and experiment.

Voltage Distortion Approach for Output Filter Design for Off-Grid and Grid-Connected PWM Inverters

  • Husev, Oleksandr;Chub, Andrii;Romero-Cadaval, Enrique;Roncero-Clemente, Carlos;Vinnikov, Dmitri
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.278-287
    • /
    • 2015
  • This paper proposes a novel voltage distortion approach for output filter design based on the voltage transfer function for both off-grid and grid-connected Pulse Width Modulation (PWM) Inverters. The method explained in detail is compared to conventional methods. A comparative analysis is performed on an example of L and LCL-filter design. Simulation and experimental results for the off-grid and the grid-connected single phase inverter prove our theoretical predictions. It was found that conventional methods define redundant values of the output filter elements. Assumptions and limitations of the proposed approach are also discussed.

The Measurement of 3-Phase Current with Single Current Sensor and the Compensation of Voltage Distortion in Carrier-Based PWM Technique (삼각파 비교 PWM 기법에 있어서 단일 전류센서에 의한 삼상 전류 측정 및 전압 왜곡 보상)

  • 김경서
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.292-298
    • /
    • 2003
  • Most of the three phase inverters for adjustable speed drive of AC machines are equipped with two or three current sensors for measurement of three phase current. One method to reduce the number of current sensors is that single current sensor measures the DC link current, then three phase current is reconstructed using the measured value and the switching status. To improve the measurement accuracy, switching state should be maintained for more than minimum switching time. Many papers have been published, which focused on the readjustment of pulse width and compensation of voltage distortion. Those methods are suitable for space vector modulation. But there are some difficulties in applying these methods to carrier-based PWM which is widely used in industry. In this paper, new current measurement method and voltage compensation method are proposed which are suitable for carrier-based PWM, then, the validity of proposed method is confirmed through experiment.

Multi-modulating Pattern - A Unified Carrier based PWM method In Multi-level Inverter - Part 2

  • Nho Nguyen Van;Youn Myung Joong
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.625-629
    • /
    • 2004
  • This paper presents a systematical approach to study carrier based PWM techniques (CPWM) in diode-clamped and cascade multilevel inverters by using a proposed named multi-modulating pattern method. This method is based on the vector correlation between CPWM and the space vector PWM (SVPWM) and applicable to both multilevel inverter topologies. A CPWM technique can be described in a general mathematical equation, and obtain the same outputs similarly as of the corresponding SVPWM. Control of the fundamental voltage, vector redundancies and phase redundancies in multilevel inverter can be formulated separately in the CPWM equation. The deduced CPWM can obtain the full vector redundancy control, and fully utilize phase redundancy in a cascade inverter In this continued part, it will be deduced correlation between CPWM equations in multi-carrier system and single carrier system, present the mathematical model of voltage source inverter related to the common mode voltage and propose a general algorithm for multi-modulating modulator. The obtained theory will be demonstrated by simulation results.

  • PDF

An Improved Wavelet PWM Technique with Output Voltage Amplitude Control for Single-phase Inverters

  • Zheng, Chun-Fang;Zhang, Bo;Qiu, Dong-Yuan;Zhang, Xiao-Hui;Li, Rui
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1407-1414
    • /
    • 2016
  • Unlike existing pulse-width modulation (PWM) techniques, such as sinusoidal PWM and random PWM, the wavelet PWM (WPWM) technique based on a Harr wavelet function can achieve a high fundamental component for the output voltage, low total harmonic distortion, and simple digital implementation. However, the original WPWM method lacks output voltage control. Thus, the practical application of the WPWM technique is limited. This study proposes an improved WPWM technique that can regulate output voltage amplitude with the addition of a parameter. The relationship between the additional parameter and the output voltage amplitude is analyzed in detail. Experimental results verify that the improved WPWM exhibits output voltage control in addition to all the merits of the WPWM technique.

Microcontroller-Based Improved Predictive Current Controlled VSI for Single-Phase Grid-Connected Systems

  • Atia, Yousry;Salem, Mahmoud
    • Journal of Power Electronics
    • /
    • v.13 no.6
    • /
    • pp.1016-1023
    • /
    • 2013
  • Predictive current control offers the potential for achieving more precise current control with a minimum of distortion and harmonic noise. However, the predictive method is difficult to implement and has a greater computational burden. This paper introduces a theoretical analysis and experimental verification for an improved predictive current control technique applied to single phase grid connected voltage source inverters (VSI). The proposed technique has simple calculations. An ATmega1280 microcontroller board is used to implement the proposed technique for a simpler and cheaper control system. To enhance the current performance and to obtain a minimum of current THD, an improved tri-level PWM switching strategy is proposed. The proposed switching strategy uses six operation modes instead of four as in the traditional strategy. Simulation results are presented to demonstrate the system performance with the improved switching strategy and its effect on current performance. The presented experimental results verify that the proposed technique can be implemented using fixed point 8-bit microcontroller to obtain excellent results.

Experimental and Numerical Analysis of a Simple Core Loss Calculation for AC Filter Inductor in PWM DC-AC Inverters

  • Lee, Kyoung-Jun;Cha, Honnyong;Lee, Jong-Pil;Yoo, Dong-Wook;Kim, Hee-Je
    • Journal of Power Electronics
    • /
    • v.13 no.1
    • /
    • pp.113-121
    • /
    • 2013
  • This paper introduces a simple core loss calculation method for output filter inductor in pulse width modulation (PWM) DC-AC inverter. Amorphous C-core (AMCC-320) is used to analyze the core loss. In order to measure core loss of the output filter inductor and validate the proposed method, a single-phase half-bridge inverter and a calorimeter are used. By changing switching frequency and modulation index (MI) of the inverter, core loss of the AMCC-320 is measured with the lab-made calorimeter and the results are compared with calculated core loss. The proposed method can be easily extended to other core loss calculation of various converters.

Observer Method for Three-Phase Current Estimation in PWM Inverters Using a single Sensor

  • Kim, Hyung-Seop;Im, Won-Sang;Ku, Hyun-Keun;Kim, Jang-Mok
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.211-212
    • /
    • 2012
  • This paper proposes a single current sensor control technique for controlling motors that use only a single DC-Link current sensing resistor to obtain the information of three line currents. However, the measurement is distorted due to the too narrow current pulse width in the shunt resistor. To solve this problem, the existing phase current reconstruction methods are voltage split methods. They have a disadvantage which makes noise. A new dedicated observer is applied to decrease noise problem. Experimental results showed the effectiveness of the proposed method.

  • PDF

LC Trap Filter Design of Single Phase NPC Multi-Level PWM Inverters for Harmonic Reduction (고조파 저감을 위한 단상 NPC 멀티레벨 PWM 인버터의 LC트랩 필터 설계)

  • Kim, Yoon-Ho;Lee, Jae-Hak;Kim, Soo-Hong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.313-320
    • /
    • 2006
  • In this paper, a design approach of LC trap filter for output side harmonic reduction of single phase NPC multilevel inverter is proposed, and THD of the output voltage and harmonic FFT of the output current are analyzed. The proposed filter consists of a conventional LCR filter cascaded with an LC trap filter and it is tuned to inverter switching frequency. A NPC multilevel inverter inverter is used an inverter system for high power application and DSP(TMS320C31) is used for the controller. The effectiveness of the proposed system confirmed through simulation and experimental results.