• 제목/요약/키워드: Single value

검색결과 3,339건 처리시간 0.029초

CAD/CAM 밀링 시스템을 활용한 단일 치관과 3본 교의치의 3D 적합도 평가 (Three-dimensional evaluation of the internal adaptation of single and three-unit fixed dental restoration by CAD/CAM milling system)

  • 김소리;김총명;김웅철;김지환
    • 대한치과기공학회지
    • /
    • 제39권1호
    • /
    • pp.35-42
    • /
    • 2017
  • Purpose: The purpose of this paper was to evaluate the occurrence of errors regarding adaptation by conducting a three-dimensional assessment comparing the bridge type dental restoration after the cutting process, which has multiple abutments, with a single type dental restoration. Methods: By using ten identical files obtained by scanning the master model, thirty designs were created consisting of ten maxillary right first premolars and ten maxillary right first molars with single crown abutments, along with ten bridge designs with the identical abutment. A 5-axis milling machine was used to produce the design file. The produced denture prostheses were scanned using a silicone replica for a STL file. An evaluation was conducted using 3D analysis software on the master model and each of the thirty data files. Results: The RMS value of the pre-molar (14) was $38.4{\pm}4{\mu}m$ for single and $54.7{\pm}6{\mu}m$ for bridge abutment; therefore, a statistically significant difference was observed for single and bridge designs although both shared the same abutment form (P<.05). Also, the RMS value of the molar (16) was $47.6{\pm}2{\mu}m$ and $56.6{\pm}5{\mu}m$ for the single and bridge designs, respectively, thereby presenting a statistically significant difference (P<.05). Conclusion: As a result, dental prosthesis fabricated using the single method presented better internal adaptation outcomes.

새로운 Cephalosporin계 항생제 IDC-7181의 랫드에 대한 단회 및 4주 반복 정맥투여 독성시험 (Single and Four-Week Intravenous Toxicity Studies of a Novel Cephalosporin Antibiotic Agent, IDC-7181, in Rats)

  • 장호송;황재식;신장우;정은용;신지순;이수해;이종성;강재훈;김기원
    • Toxicological Research
    • /
    • 제18권2호
    • /
    • pp.195-203
    • /
    • 2002
  • This study was performed to evaluate single and repeated-dose toxicities oj a new cophalosporin antibiotic agent IDC-7l81 in Sprague-Dawley rats. IDC-7181 was injected intravenously to rats at dose levels of 0, 3.2, 16, 80, 400 and 2,000 mg/kg/day for single-dose toxicity study and at dose levels of 0, 10, 50 and 250 mg/kg/day for 4-week repeated-dose toxicity study. In both studies, there were no dose-related changes in mortality clinical signs, body weight changes, food and water consumption, opthalmoscopy, organ weights, urine analysis, biochemical examination, and hematological findings of all animals treated with IDC-7l8l. Gross and histopathological findings revealed no evidence of specific toxicity related to IDC-7181. These results suggest that the intravenous maximum tolerated dose value of IDC-7181 may be over 250 mg/kg and $LD_{50}$ value may be over 2,000 mg/kg in rats.

에지계면균열을 갖는 단순겹치기 접착이음의 강도평가 (Analysis on the Bonded Single Lap-Joint Containing the Interface Edge Crack)

  • 유영철;박정환;이원
    • 한국정밀공학회지
    • /
    • 제15권6호
    • /
    • pp.159-166
    • /
    • 1998
  • The problem of interface crack in the bonded structures has received a great deal of attention in recent years. In this paper the aluminum bonded single lap-joint containing the interface edge crack is investigated. The tensile load and the average shear stress of the adhesive joints which have different crack length are obtained from the static tensile tests. The critical value of crack length to provoke the interface fracture is determined to a/L=0.4, where a is the interface crack length and L is the adhesive lap-length. The fracture mechanical parameters are introduced to confirm the existence of the critical crack length. The compliance and the stress intensity factors are calculated using the displacement and the stress near the interface crack tip by the boundary element method. These numerical results support the experimental results that the critical value of a/L is 0.4. It is known that the compliance and the stress intensity factors are the efficient parameters to estimate the bonded single lap-joint containing the interface edge crack.

  • PDF

발효차 청태전 제조용 미생물의 분리 (Isolating Microorganisms to Ferment Traditional Cheongtaejeon)

  • 박정숙;조정일
    • 한국식생활문화학회지
    • /
    • 제26권2호
    • /
    • pp.190-197
    • /
    • 2011
  • Chungtaejeon is a traditional tea introduced in the age of the Three States and is the only "Don-cha" culture in the world that survived on the southwestern shore of Korea. To restore Chungtaejeon and to make the tea with consistent quality, the microorganisms involved in traditional type fermentation of Chungtaejeon were isolated, and the tea was prepared with high fermentation ability starters. The sensuous characteristics of Chungtaejeon were also examined. Only Bacilli were found in 3 and 5 year aged Chungtaejeon samples. The Lactobacilli were isolated from properly fermented kimchi and one of them showed high growth capability in media containing green tea extract and also showed strong antagonistic activity against methicillin-resistant Staphylococcus aureus, S. aureus, Salmonella, and E. coli. It was identified and named Lactobacillus plantarum CHO25. Chungtaejeon was fermented with a single starter of L. plantarum CHO25 and with a mixed starter (L. plantarum CHO25, Saccharomyces cerevisiae and Bacillus amyloliquefaciens CHO104). The single fermented sample had the highest cell growth after 5 days of inoculation and the level decreased slowly thereafter. The mixed fermented sample showed strong growth of S. cerevisiae. The highest hunter values were the a value of the single fermented sample and the b value of the mixed sample. The single fermented tea showed the best incense score.

Single Junction Charge Pumping 방법을 이용한 전하 트랩형 SONOSFET NVSM 셀의 기억 트랩분포 결정 (Determination of Memory Trap Distribution in Charge Trap Type SONOSFET NVSM Cells Using Single Junction Charge Pumping Method)

  • 양전우;홍순혁;서광열
    • 한국전기전자재료학회논문지
    • /
    • 제13권10호
    • /
    • pp.822-827
    • /
    • 2000
  • The Si-SiO$_2$interface trap and nitride bulk trap distribution of SONOSFET(polysilicon-oxide-nitride-oxide-semiconductor field effect transistor) NVSM (nonvolatile semiconductor memory) cell is investigated by single junction charge pumping method. The device was fabricated by 0.35㎛ standard logic fabrication process including the ONO stack dielectrics. The thickness of ONO dielectricis are 24$\AA$ for tunnel oxide, 74 $\AA$ for nitride and 25 $\AA$ for blocking oxide, respectively. By the use of single junction charge pumping method, the lateral profiles of both interface and memory traps can be calculated directly from experimental charge pumping results without complex numerical simulation. The interface traps were almost uniformly distributed over the whole channel region and its maximum value was 7.97$\times$10$\^$10/㎠. The memory traps were uniformly distributed in the nitride layer and its maximum value was 1.04$\times$10$\^$19/㎤. The degradation characteristics of SONOSFET with write/erase cycling also were investigated.

  • PDF

관자뼈의 확산강조영상검사 시 Single Shot Turbo Spin Echo 기법의 유용성 (The Utility of Single Shot Turbo Spin Echo Technique for Temporal Bone Diffusion Weighted Imaging)

  • 최관우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권1호
    • /
    • pp.25-30
    • /
    • 2021
  • The purpose was to reduce the distortion of the image that occurs in the temporal bone area due to the very strong differences in susceptibility. A new SS-TSE technique was applied when examining the diffusion-weighted image of the temporal bone, where the auditory and facial nerves to be imaged were very thin and were adjacent to the cranial base including bone and air. This study was conducted from March 2020 to August of the same year, targeting 32 subjects who underwent the diffusion-weighted imaging of the temporal bone. To compare the distortion, existing SS-EPI technique and the new SS-TSE technique were both applied on the temporal bone area. As a result of the study, applying the new SS-TSE technique appeared to lower the distortion of images by 87.44, 46.13 and 42.35 % on the b-value 0, 800 and the ADC images, respectively. In conclusion, when using the new SS-TSE technique on the temporal bone DWI, distortion can be reduced, and thus images with high diagnostic value can be obtained.

Filter Design for Grid-Connected Single-Phase Inverters

  • Kim, Hyo-Sung
    • Journal of Power Electronics
    • /
    • 제9권4호
    • /
    • pp.623-630
    • /
    • 2009
  • This paper proposes a filter design guideline for grid-connected single-phase inverters. By analyzing the instantaneous voltage applied to the filter inductor, the switching ripple current through the filter inductor can be precisely calculated. Therefore, filter inductance can be designed accurately, which guaranties that the switching ripple current will be under the target value. The proposed filter design method is verified by experiment.

단일 경량콘크리트판넬의 차음성능 예측 (Prediction of Sound Transmission through Single Lightweight Concrete Panel)

  • 양홍석;안지형;김명준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.56-60
    • /
    • 2007
  • Nowadays shear wall structural system is gradually changing to framed structure. For this reason, lightweight panel is increasingly being used as separating walls. One of design methods to obtain high transmission loss is double panel. To predict the acoustic performance of double panel, prediction of transmission loss of single panel must be performed, previously. In this study, the predicted values for four single panels were compared with the measured values. The result shows the arithmetical average deviations(100Hz to 3150Hz) between the predicted and measured transmission loss were in range between 1.1dB and 3.9dB. The predicted values were generally lower than measured values above critical frequency. The single-number quantities, $R_W+C$, were predicted in range between 36dB to 38dB, and the differences of single-number quantities between the predicted and measured value were within 1dB.

  • PDF

스마트폰 영상정보를 활용한 쿼터니언 기반 후방교회법과 PnP 알고리즘의 외부표정요소 비교 분석 (Comparative Analysis of Exterior Orientation Parameters of Smartphone Images Using Quaternion-Based SPR and PnP Algorithms)

  • 김남훈;이지상;배준수;손홍규
    • 한국측량학회지
    • /
    • 제37권6호
    • /
    • pp.465-472
    • /
    • 2019
  • 사진 촬영 당시의 외부표정요소 추정 방법에는 공선조건식 기반 후방교회법이 널리 사용되지만 초기값을 필요로 하고, 그 값에 민감하다는 단점이 있다. 본 연구에서는 초기값을 필요로 하지 않는 외부표정요소 알고리즘인 쿼터니언 기반 공간후방교회법과 PnP (Perspective-n-Point algorithm)을 소개하고 그 결과를 비교하였다. 두 결과를 비교하기 위하여 일반 스마트폰으로 취득한 영상을 사용하였고, 지상기준점 취득은 본 연구진이 보유하고 있는 하이브리드 MMS (Mobile Mapping System) 점군 자료를 이용하였다. 그 결과, 공선조건식 기반 SPR (Single Photo Resection)을 참값으로 할 때, 쿼터니언 기반 SPR이 PnP 알고리즘에 비해 자세각 추정 정확도가 높았다. 카메라 위치추정의 경우에는 두 알고리즘 모두 지상기준점과 비교했을 때 0.8m 내의 정확도를 보임을 확인하였다.

Al-MIS(p-Si) 태양전지의 AR Coating 방법 (On the AR Coating Method of Al-MIS(p-Si) Solar Cel)

  • 엄경숙;백수현
    • 대한전자공학회논문지
    • /
    • 제21권6호
    • /
    • pp.64-69
    • /
    • 1984
  • Al-MIS(p-Si)태양전지의 최대 효율은 Al 박막을 0.6A/sec 이하의 속도로 증착시켜 80Å인 두께가 되었을 때임을 알았다. ZnS와 SiO로 AR coating을 했는데, 단층 피막일때는 각각 570Å과 690Å인 박막 두께에서 최대 Isc를 나타냈다. 이는 quarter-coating 조건인 n1d1=λ/4를 만족함을 알았다. 이중층 피막일 때는 한 층을 단층 피막때의 최적 두께를 유지하면서 다른 한 층을 조절했다. 이때의 최대 Isc는 단층피막일 때와 비슷한 값이었으나 넓은 범위의 두께에서 그 값이 그대로 유지되었다. 한편 dzns/ds10=1.9/2.3=570/690인 관계를 유지하면서 총 두께를 각각의 단층피막때의 최적 두께 합에 대해서 70∼90%로 얇게 했을 때 앞에서 논의한 어떤 경우보다도 20%이상의 더 높은 Isc를 얻을 수 있었다 따라서 높은 효율을 얻으면서 정밀한 두께 조절이 불필요한 새로운 AR coating방법을 얻었다.

  • PDF