• 제목/요약/키워드: Single use device

검색결과 233건 처리시간 0.026초

일회용 의료기기에 적용을 위한 ISO 14971:2019 분석과 Periodic Safety Update Report 작성 방법 - Medical Device Regulation 2017/745 요구사항 중심으로 (ISO14971:2019 Detailed Analysis and Periodic Safety Update Report Establishment Method for the Single Use Medical Device - Focusing on Medical Device Regulation 2017/745 requirements)

  • 박상민;류규하
    • 대한의용생체공학회:의공학회지
    • /
    • 제44권1호
    • /
    • pp.1-10
    • /
    • 2023
  • With the announcement of MEDICAL DEVICE REGULATION 2017/745 (MDR) on April 5 2017, medical device manufacturers shall apply ISO 14971:2019 (3rd) revised in December 2019. However, there is not much related information and guidance available to medical device manufacturers, especially single use medical device. Risk management process basically follow 5 steps which are Risk Analysis, Risk Evaluation, Risk Control, Evaluation of overall residual risk and post-production activities. The purpose of this study is to provide a guidance of from risk analysis with Failure Mode and Effects Analysis (FMEA) table to overall residual risk evaluation for the single use medical device and to reflect it in a Periodic Safety Update Reports (PSUR) to satisfy with MDR requirements with single use medical device which are widely used and manufactured FDA class 2 or CE class IIb as examples. For this study, single use medical device manufacturer can adopt ISO 14971:2019 in accordance with MDR requirements and it can be extended to the PSUR. But there are still limitations to adopt to the all-single use medical device especially high class, private device and implantable device. So, Competent Authority (CA) shall publish more guidance for the single use medical device.

프레스 공정 단축을 위한 회전식 트랜스퍼 성형장치 개발 (Development of Rotary Transfer Forming Device for Process Reduction in Forming)

  • 김승기;윤재웅
    • 한국생산제조학회지
    • /
    • 제23권5호
    • /
    • pp.413-420
    • /
    • 2014
  • Although the transfer forming process has various advantages, it is also inefficient for the use of multiple press machines, especially for small part sizes. In this study, a new forming process was proposed to use multiple tandem dies in a single press machine. A rotary transfer forming device was developed to combine the advantages of the progressive and transfer forming process. In this study, a detailed forming process using this device was analyzed, and the device was designed to perform four series of tandem forming processes in a single press. In order to analyze the feasibility of this forming process, simple forming dies were made. As a result, the position accuracy was 4 arcsec, and the forming speed reached up to 20 strokes per minute. It is thought that this rotary transfer forming device can help to save initial setup costs through the more efficient use of space in a press machine.

단상 SRM에 사용되는 전자석 기동 장치 (Electromagnet Starting Device used in the Single-Phase SRM)

  • 김준호;이은웅;이종한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.813-814
    • /
    • 2006
  • The squirrel case induction motor has widely used in the driving of the blowers but it is low efficiency and hard to control. So, the damper is used for the control of a flow and it cause to low the driving efficiency. Our laboratory has proposed the single-phase SRM(switched reluctance motor) for driving blowers. It has salient pole structure and can be reduced a number of semiconductors than three-phase SRM. But it can not be starting by itself and has heavier torque ripple than three-phase SRM. For self-starting the single-phase SRM is required the starting device which place the rotor at the rising inductance slope. On this paper, the electromagnet starting device is designed to generate the starting torque and to fix the rotating direction of the single-phase SRM which is fabricaed to use a blower.

  • PDF

Slipchip Device Development in Molecular Diagnostics

  • Qingtian Yin;Huiwen Bai;Ruijie Li;Youngung Seok
    • 한국재료학회지
    • /
    • 제34권2호
    • /
    • pp.63-71
    • /
    • 2024
  • Slipchip offers advantages such as high-throughout, low cost, and simple operation, and therefore, it is one of the technologies with the greatest potential for high-throughput, single-cell, and single-molecule analyses. Slipchip devices have achieved remarkable advances over the past decades, with its simplified molecular diagnostics gaining particular attention, especially during the COVID-19 pandemic and in various infectious diseases scenarios. Medical testing based on nucleic acid amplification in the Slipchip has become a promising alternative simple and rapid diagnostic tool in field situations. Herein, we present a comprehensive review of Slipchip device advances in molecular diagnostics, highlighting its use in digital recombinase polymerase amplification (RPA), loop-mediated isothermal amplification (LAMP), and polymerase chain reaction (PCR). Slipchip technology allows users to conduct reliable droplet transfers with high-throughput potential for single-cell and molecule analyses. This review explores the device's versatility in miniaturized and rapid molecular diagnostics. A complete Slipchip device can be operated without special equipment or skilled handling, and provides high-throughput results in minimum settings. This review focuses on recent developments and Slipchip device challenges that need to be addressed for further advancements in microfluidics technology.

유비쿼터스 컴퓨팅 환경에서 속성 인증서를 이용한 단일/멀티 도메인 인증 (Authentication for Single/Multiple Domain using Attribute Certificates)

  • 이덕규;박희운;이임영
    • 한국정보과학회논문지:정보통신
    • /
    • 제32권3호
    • /
    • pp.291-300
    • /
    • 2005
  • 유비쿼터스 컴퓨터 환경은 사용자가 언제 어디서나 컴퓨터를 이용할 수 있도록 네트워크를 통해 상호 연결된 보이지 않는 수많은 컴퓨터(Invisible Computer)가 편재되고 사용자가 원하는 대로 쉽게 이용할 수 있는 컴퓨팅 환경을 지향하고 더 나아가서는 사용자가 원하는 컴퓨팅을 컴퓨터 스스로 알아서 (상황인식 Context Awareness) 제공하는 스마트 환경이다. 이러한 유비쿼터스 컴퓨팅은 보안에 있어 특히 취약한 면을 많이 내포하고 있다. 그 중에서도 분산된 다양한 컴퓨팅 기기들이 도처에 존재함으로 인해 사웅자 주턴에 있는 기기 중에서 사웅자 혹은 서버에 인증된 기기로의 위장공격 등이 가능해진다. 이에 본 논문에서는 다음과 같은 특징을 가지는 방식을 제안한다. 디바이스의 이동을 통한 인증 모델을 제시한다. 이는 개인의 작은 디바이스가 다른 사용자의 공간(MD: Multi Domain)로 이동하였을 경우 디바이스를 통한 인증을 실쳔하는 방식과 사용자 자신의 공간(SD: SinEle Domain)으로 이동하였을 경우 디바이스를 통한 인증을 실현하는 두 가지 방식을 제안한다.

일회용침 단체표준의 개발과 향후 전망 (Perspective on the Development of the Cooperation Group Standards of Acupuncture Needles for Single Use in Korea)

  • 장인수;김장현;박재현;박종배;박히준;서정철;송호섭;이인환;이향숙;최선미;한창호;구성태
    • 대한한의학회지
    • /
    • 제27권3호
    • /
    • pp.222-226
    • /
    • 2006
  • Objective: The aim of this study was to introduce newly developed cooperation group standards of acupuncture needles for single use and to make a contribution to the future development of Korean Industrial Standards (KS) of acupuncture needles for single use. Results and Conclusion: Quality assurance and quality control with high safety profile is one of the most critical issues in medical device manufacturing. Up to now, proper attention has not been paid to this issue with respect to acupuncture needles for single use and their related devices. We, therefore, organized a committee to make guidelines to produce an acupuncture needle with high quality and safety. In the committee, we reviewed the topic from an historical viewpoint, and investigated the current situation of the standardization of acupuncture needles in other developed countries. Finally, we developed the cooperation group standards in advance of development of KS on the acupuncture needles for single use. The standards are composed of 12 sections describing: Scope, Normative references, Definitions, Materials, Configuration, Appearance and Cleanliness, Quality, Sterilization and Safety, Processing of Surface and Coating Material, Test, Packaging, and Labeling. We hope that the standards would be useful guidelines to produce high quality acupuncture needles and play an important role in the development of KS in the future.

  • PDF

A brief review on the recent progress of superconducting nanowire single photon detectors

  • Chong, Yonuk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제19권4호
    • /
    • pp.22-25
    • /
    • 2017
  • Superconducting nanowire single photon detectors (SNSPD) have become the most competent photon-counting devices in wide range of wavelengths. Especially in the communication wavelength (infrared), SNSPD has shown unbeatable superior performance compared to the state-of-art semiconductor single photon detectors. The technology has matured enough for the last decade so that several commercial systems are now almost ready for routine use in general optics experiments. Here we summarize briefly the recent progress in this research field, and hope to motivate further research on the improvement of the device and the system. We cover the basic key concepts, device and system performances, remaining issues and possible further research directions of SNSPD.

InGaAsP/InP Buried-Ridge Waveguide Laser with Improved Lateral Single-Mode Property

  • Oh, Su-Hwan;Kim, Ki-Soo;Kwon, Oh-Kee;Oh, Kwang-Ryong
    • ETRI Journal
    • /
    • 제30권3호
    • /
    • pp.480-482
    • /
    • 2008
  • A novel InGaAsP/InP buried-ridge waveguide laser diode structure is proposed and demonstrated for use as a single-mode laser. The lateral mode of the proposed device can be controlled by adjusting the composition and thickness of the InGaAsP layer grown over the active region. Stable single-mode operation without kinks or beam-steering is achieved successfully with lateral and transverse in the junction plane even for the device with the ridge width of 9 ${\mu}m$ up to an injection current of 500 mA.

  • PDF

Continuous Human Activity Detection Using Multiple Smart Wearable Devices in IoT Environments

  • Alshamrani, Adel
    • International Journal of Computer Science & Network Security
    • /
    • 제21권2호
    • /
    • pp.221-228
    • /
    • 2021
  • Recent improvements on the quality, fidelity and availability of biometric data have led to effective human physical activity detection (HPAD) in real time which adds significant value to applications such as human behavior identification, healthcare monitoring, and user authentication. Current approaches usually use machine-learning techniques for human physical activity recognition based on the data collected from wearable accelerometer sensor from a single wearable smart device on the user. However, collecting data from a single wearable smart device may not provide the complete user activity data as it is usually attached to only single part of the user's body. In addition, in case of the absence of the single sensor, then no data can be collected. Hence, in this paper, a continuous HPAD will be presented to effectively perform user activity detection with mobile service infrastructure using multiple wearable smart devices, namely smartphone and smartwatch placed in various locations on user's body for more accurate HPAD. A case study on a comprehensive dataset of classified human physical activities with our HAPD approach shows substantial improvement in HPAD accuracy.

전기화재 분야에서 다목적으로 시험장치의 활용범위를 증가시키기 위한 시험장치의 설계 및 구현 (Design and Implementation of a Multi-purpose Test Equipment with a Large Utilization Range for use in Electric Fire)

  • 신동철;고형호
    • 센서학회지
    • /
    • 제32권3호
    • /
    • pp.180-186
    • /
    • 2023
  • Test devices can perform various functions, such as research on detection targets, sensors that detect detection targets, combined products containing sensors, and certification for the launch of combined products. However, the scope of use of test devices is limited because they perform only a single role or could only serve a particular purpose in the past. Therefore, studies on test devices that can perform various functions, such as research on detection targets, sensors that detect detection targets, combined products containing sensors, and certification for the release of combined products are necessary. Accordingly, this study proposes a test device that can increase the scope of use in the technical field of electric fires. In addition, we examine various outcomes of the proposed test device.