• Title/Summary/Keyword: Single use device

Search Result 233, Processing Time 0.027 seconds

A Study on design of the PZT Cantilever for Micro Switch (Micro Switch용 PZT Cantilever의 설계에 관한 연구)

  • Kim, In-Sung;Song, Jae-Sung;Min, Bok-Ki;Jeong, Soon-Jong;Muller, A.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.422-423
    • /
    • 2005
  • RF Micro switches is a miniature device or an array of integration devices and mechanical components and fabricated with Ie batch-processing techniques. RF Micro switches application area are in phased arrays and reconfigurable apertures for defence and telecommunication systems, switching network for satellite communication, and single-pole double throw switches for wireless application. Recently, RF Micro switches have been developed for the application to the milimeter wave system. RF Micro switches offer a substantilly higher performance than PIN diode or FET switches. In this paper, SPDT(single-pole-double-throw) switch are designed to use 10 GHz. Actuation voltage and displacement are simulated by tool.

  • PDF

A Study on design of the Ferroelectrics Cantilever for RF Switch (RF Switch용 강유전체 Cantilever 설계에 관한 연구)

  • Kim, In-Sung;Min, Bok-Ki;Song, Jae-Sung;Muller, A.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.652-655
    • /
    • 2004
  • RF MEMS is a miniature device or an array of integration devices and mechanical components and fabricated with If batch-processing techniques. RF MEMS application area are in phased arrays and reconfigurable apertures for defence and telecommunication systems, switching network for satellite communication, and single-pole double throw switches for wireless application. Recently, RF MEMS switches have been developed for the application to the milimeter wave system. RF MEMS switches offer a substantilly higher performance than PM diode or FET switches. In this paper, SPDT(single-pole-double-throw) switch are designed to use 10 GHz. Actuation voltage and displacement are simulated by tool. And stress and distribution are simulated.

  • PDF

The Edge Computing System for the Detection of Water Usage Activities with Sound Classification (음향 기반 물 사용 활동 감지용 엣지 컴퓨팅 시스템)

  • Seung-Ho Hyun;Youngjoon Chee
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.2
    • /
    • pp.147-156
    • /
    • 2023
  • Efforts to employ smart home sensors to monitor the indoor activities of elderly single residents have been made to assess the feasibility of a safe and healthy lifestyle. However, the bathroom remains an area of blind spot. In this study, we have developed and evaluated a new edge computer device that can automatically detect water usage activities in the bathroom and record the activity log on a cloud server. Three kinds of sound as flushing, showering, and washing using wash basin generated during water usage were recorded and cut into 1-second scenes. These sound clips were then converted into a 2-dimensional image using MEL-spectrogram. Sound data augmentation techniques were adopted to obtain better learning effect from smaller number of data sets. These techniques, some of which are applied in time domain and others in frequency domain, increased the number of training data set by 30 times. A deep learning model, called CRNN, combining Convolutional Neural Network and Recurrent Neural Network was employed. The edge device was implemented using Raspberry Pi 4 and was equipped with a condenser microphone and amplifier to run the pre-trained model in real-time. The detected activities were recorded as text-based activity logs on a Firebase server. Performance was evaluated in two bathrooms for the three water usage activities, resulting in an accuracy of 96.1% and 88.2%, and F1 Score of 96.1% and 87.8%, respectively. Most of the classification errors were observed in the water sound from washing. In conclusion, this system demonstrates the potential for use in recording the activities as a lifelog of elderly single residents to a cloud server over the long-term.

A Multi-chambered Single Autoinjector: Design and Performance Assesment (다중챔버 단일주사기: 설계, 성능 평가)

  • An, Seoyeon;Lee, Keunwoo;Kwon, Taekeun;Kim, Dongyeon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.170-180
    • /
    • 2017
  • An autoinjector allows a single use medical device serving for automatic intramuscular injection to deliver a dose of a particular emergency drug through an intuitive activation mechanism. By design and structure, autoinjectors are easy to use and are intended for self-administration by patients or untrained personnel. Depending on the number of drugs filled in the cartridge, autoinjectors are divided by one-chamber type and multi-chamber type. Most autoinjectors may have a special structure including spring-loading syringes and needle which is specially designed to ensure strength due to the necessity of penetration through layers of clothing. The purpose of this study was to introduce the design technology of autoinjector of multi-chamber type that could be released into the two drugs sequentially. Additionally, we verified performance of the prototype developed by applying the design.

A Framework of User Authentication for Financial Transaction based Multi-Biometrics in Mobile Environments (모바일 환경에서 다중 바이오인식 기반의 금융 거래를 위한 사용자 인증 프레임워크)

  • Han, Seung-Jin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.1
    • /
    • pp.143-151
    • /
    • 2015
  • Biometric technology has been proposed as a new means to replace conventional PIN or password because it is hard to be lost and has the low possibility of illegal use. However, unlike a PIN, password, and personal information there is no way to modify the exposure if it is exposed and used illegally. Therefore, the existing single modality with single biometrics is critical when it expose. However in this paper, we use a multi-modality and multi-biometrics to authenticate between users and TTP or between users and financial institutions. Thereby, we propose a more reliable method and compared this paper with existed methods about security and performance in this paper.

An All-Optical NOR Logic Device using a Semiconductor Optical Amplifier and an External Modulation Technique (반도체 광증폭기와 외부변조 기법을 이용한 전광 NOR 논리소자)

  • Byun, Young-Tae;Kim, Sang-Hyuck;Lee, Seok;Kim, Jae-Hun;Woo, Deok-Ha;Kim, Sun-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.197-200
    • /
    • 2000
  • All-optical NOR logic device was realized by use of two pump signals with a single wavelength and a semiconductor optical amplifier(SOA). Specially, Mach-Zehnder(MZ) modulator was used for an external modulation of the pump signals. To obtain the sufficient gain saturation of the SOA, pump signals are amplified by an Er-doped fiber amplifier(EDFA) at the input of the SOA. Pump and probe signals are obtained from a DFB laser diode(${\lambda}_p$=1554 nm) and a tunable laser diode(${\lambda}_s$=1535 nm), respectively. The operation characteristics of the NOR logic device are successfully measured and demonstrated at the modulation frequency of 4.83 MHz.

  • PDF

Clinical outcomes of a low-cost single-channel myoelectric-interface three-dimensional hand prosthesis

  • Ku, Inhoe;Lee, Gordon K.;Park, Chan Yong;Lee, Janghyuk;Jeong, Euicheol
    • Archives of Plastic Surgery
    • /
    • v.46 no.4
    • /
    • pp.303-310
    • /
    • 2019
  • Background Prosthetic hands with a myoelectric interface have recently received interest within the broader category of hand prostheses, but their high cost is a major barrier to use. Modern three-dimensional (3D) printing technology has enabled more widespread development and cost-effectiveness in the field of prostheses. The objective of the present study was to evaluate the clinical impact of a low-cost 3D-printed myoelectric-interface prosthetic hand on patients' daily life. Methods A prospective review of all upper-arm transradial amputation amputees who used 3D-printed myoelectric interface prostheses (Mark V) between January 2016 and August 2017 was conducted. The functional outcomes of prosthesis usage over a 3-month follow-up period were measured using a validated method (Orthotics Prosthetics User Survey-Upper Extremity Functional Status [OPUS-UEFS]). In addition, the correlation between the length of the amputated radius and changes in OPUS-UEFS scores was analyzed. Results Ten patients were included in the study. After use of the 3D-printed myoelectric single electromyography channel prosthesis for 3 months, the average OPUS-UEFS score significantly increased from 45.50 to 60.10. The Spearman correlation coefficient (r) of the correlation between radius length and OPUS-UEFS at the 3rd month of prosthetic use was 0.815. Conclusions This low-cost 3D-printed myoelectric-interface prosthetic hand with a single reliable myoelectrical signal shows the potential to positively impact amputees' quality of life through daily usage. The emergence of a low-cost 3D-printed myoelectric prosthesis could lead to new market trends, with such a device gaining popularity via reduced production costs and increased market demand.

Contraception Behaviors in Unmarried Men and Women: A Descriptive Qualitative Approach (미혼남녀의 피임경험에 관한 질적 연구)

  • Hwang, Shin Woo;Chung, Chae Weon
    • Perspectives in Nursing Science
    • /
    • v.9 no.2
    • /
    • pp.71-82
    • /
    • 2012
  • Purpose: The aim of this study was to identify contraception behaviors in unmarried men and women. Methods: A descriptive qualitative study design was used. Individual in-depth interviews with fifteen participants were conducted. Content analysis was utilized to determine the main outcomes. Results: For men, three themes were consistently seen as contraception behaviors: 'men desired sexual intercourse greatly', 'men would not use a contraceptive device, even though they knew it was necessary', and 'men gradually considered contraceptive use to live their lives without interruption'. For women, the three themes were as follow: 'women had sex half willingly while half did not have sexual inter course for the first time', 'women did not use contraceptive devices because of ignorance of contraceptive methods', and 'women did not carefully consider contraceptive use'. Conclusion: To prevent unmarried men and women from having unplanned pregnancies, tailored sex education programs should be established throughout Korea. All things considered, the effect of multimedia sex education should be considered to maximize the use of contraceptive devices.

  • PDF

Design of Torque Actuator in Hybrid Multi-D.O.F. System (하이브리드 다자유도 시스템의 틸팅 구동용 토크액츄에이터 설계)

  • Hong, Hyun-Seok;Park, Hyun-Jong;Won, Sung-Hong;Kim, Sol;Lee, Ju
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.665-666
    • /
    • 2015
  • In this paper, it is proposed to substitute the tilting operation device of hybrid multi-D.O.F system from three phase SPM to single phase torque actuator. When using tilting operation with three phase SPM which is appropriate for continuous rotary operation, there are disadvantages that electricity availability rate is low and controllability is difficult. On the other hand when using a single phase torque actuator instead of SPM, it is appropriate for sequential tilting, electricity availability rate is high, and it is easy to control. Thus this will have a great influence on the development and practical use of the system. This study designed a single phase torque actuator in consideration of the magnetic saturation. Also, this was verified with comparative analysis with SPM through FEM(finite element method) analysis values of the design model and test values of the manufactured model.

  • PDF

A Feasibility Study for Application of Single-Chip Solution for Diagnostic Resting ECG (ECG 원칩 솔루션의 진단용 심전계 적용을 위한 타당성 연구)

  • Kang, Bum-Sun;Choi, Gi Sang
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.4
    • /
    • pp.86-94
    • /
    • 2015
  • In order for medical devices to be used outside hospital, they have to be not only of small size but also power consumption has to be kept at low level. This study investigates the feasibility of application of ADS1298 ECG single-chip solution developed by Texas Instruments Inc. for use in development of a new platform for diagnostic resting ECG. To prove the feasibility of commercial products based on the ADS1298 chip, the performance of the ADS1298 chip was measured in terms of input impedance, common mode rejection, frequency response, and input dynamic range using the testing method under the suitability criteria of the IEC 60601-2-25 standard. Result of the this study shows that commercialization of the ECG products based on the ADS1298 ECG single-chip solution that satisfies the international standards would be possible, if the manufactures take the filter characteristics into account in building a new platform for diagnostic resting ECG.