• 제목/요약/키워드: Single station

Search Result 630, Processing Time 0.041 seconds

Analysis of Flood Stage in a Confluence using the Dynamic Numerical Model (동역학적 수치모형을 이용한 합류부 홍수위 분석)

  • Kim, Ji Sung;Kim, Keuk Soo;Kim, Won;Kim, Sang Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5B
    • /
    • pp.453-461
    • /
    • 2009
  • In this study, a dynamic numerical model, FLDWAV, is used for analyzing the backwater effect of flood stage in YeongWeol station, which is located on the confluence upstream where Pyeongchang river joins Han river. Given various inflow discharges of both main stream and tributary, the feasible stage-discharge relationships at the YeongWeol station and the upstream range of the backwater effect were computed. The results show that the relationships are completely different according to each of the inflow discharges from tributary and the maximum difference of stage is about 4.0 m. Therefore, the development of a single relationship of stage and discharge is very difficult problem in the zone of backwater effect. The increase of stage in the junction due to the lateral inflow has an effect on upstream stage up to about 8.0 km. The well-calibrated and verified dynamic wave routing model will be a useful tool for the flood forecast in the zone of backwater effect rather than conventional hydrological routing model.

Clinical Significance of the Aortic Node in Non-small Cell Lung Cancer of the Left Upper Lobe (좌상엽에 발생한 비소세포형 폐암에서 Aortic Node의 의의)

  • 김대준;김길동;이기종;정경영
    • Journal of Chest Surgery
    • /
    • v.36 no.11
    • /
    • pp.846-851
    • /
    • 2003
  • Background: To clarify the clinical significance of the aortic nodes in resected non-small cell lung cancer of the left upper lobe. Material and Method: One hundred fifty six patients with resected non-small cell lung cancer of the left upper lobe were studied. Patients who received preoperative induction therapy, non-curative operation or defined as operative mortality were excluded from this study. Result: In N2 left upper lobe tumors, aortic nodes comprised 52.7% of the metastatic mediastinal lymph nodes. In single station N2 disease, a frequently metastasized station was aortic node (64.3%). 5-year actuarial survival according to the N status was 65.0% in N0, 30.4% in N1, and 17.9% in N2. There was no statistically significant difference in survival between N1 and N2 diseases (p=0.06). The patients with metastasis to aortic node alone had a comparatively good prognosis (5-year survival: 35.6%) than other N2 diseases (5-year survival: 4.6%) (p=0.01) and had a similar survival outcome as N1 diseases (p=0.97). Considering the aortic node as N1 node, 5-year survival according to the N status was 65.0% in N0, 31.2% in N1, 4.6% in N2 and significant survival difference was observed between N1 and N2 disease (p=0.00). In multivariate analysis, the male sex (hazard ratio 6.892, p=0.011) and the involvement to the aortic node alone (hazards ratio 2.799, p=0.009) were the significant factors affecting postoperative survival. Conclusion: According to the our data, involvement to the aortic node alone in left upper lobe tumors should be grouped with N1 disease because this combined category reflects the surgical outcome more accurately.

A Study on Accuracy Evaluation and Accuracy Improvement in Cadastral Re-survey Surveying Method (지적재조사 측량방법의 정확도 비교 및 정확도 향상방안 연구)

  • Lee, Suk Bae;Auh, Su Chang;Suh, Yong Woon
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.22 no.4
    • /
    • pp.39-46
    • /
    • 2014
  • Network RTK GNSS positioning technique which has been developed to overcome the limitation of Single reference station RTK is used widely in the field of general surveying, cadastre surveying and engineering surveying due to the high accuracy and efficiency. It is specified Network RTK, Single reference station RTK and Static of GNSS as a surveying method in the regulation of Cadastre Re-survey Surveying. In this study, Network RTK and Static GNSS surveying were accomplished at cadastral re-survey field in Hadong, Gyeongnam and the surveying results were compared. Also, to analyze the performance of site calibration in Network RTK surveying, two types of Network RTK surveying with and without site calibration were accomplished and the results was compared. The research result shows that average positioning error between Network RTK(VRS) without site calibration and Static surveying result is 2.44cm and 1.53cm respectively and average positioning error between Network RTK(VRS) with site calibration and Static surveying result is 0.19cm and 0.82cm respectively at two zone. So, it was proved the effect of calibration in network RTK(VRS) surveying.

Characteristics of Indigenous Rhizobium to Korean Soils III. Symbiotic Dynamics of Bradyrhizobium japonicum YCK Strains According to Their Competitive Conditions for Nodulation (우리나라 토착근류균(土着根瘤菌)의 제(諸) 특성(特性) 연구(硏究) III. 수종(數種) Bradyrhizobium japonicum YCK 균주(菌株)의 경합여부(競合與否)에 따른 공생효과 변이(變異))

  • Kang, Ui-Gum;Jung, Yeun-Tae;Ha, Ho-Sung;Somasegaran, Padma;Bohlool, B. Ben
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.26 no.4
    • /
    • pp.265-270
    • /
    • 1993
  • The symbiotic dynamics of Bradyrhiwbium japonicum YCK strains indigenous to Korean soils were investigated accordingly to their competitive conditions for nodulation. For this experiment the single strain inoculants of YCK strains and the mixed inoculants of one YCK strain and one USDA strain were applied to Korean Jangbaekkong and American Clark soybeans at mollisol soils(Torroxic Haplustoll, pH 6.8). The results were summarized as follows : 1. The symbiotic effectiveness of B. japonicum YCK strains was increased on the average of nitrogen accumulation by mixing with USDA strains, especially with strain USDA 110. 2. The effectiveness of each mixed inoculant was affected by soybean cultivar. 3. YCK strains occupied on the average of 83 and 86 % of the nodules against strain USDA 110 on Jangbaekkong and Clark soybeans, respectitvely. 4. The most effective strain among three YCK strains was strain YCK 213 as a single inoculant and was strain YCK 141 as a mixed inoculant with USDA strains. 5. The mixed inoculants of YCK strains and strain USDA 123 showed antagonism for nodulation.

  • PDF

VRS-based Precision Positioning using Civilian GPS Code Measurements (가상기준점 기반 코드신호를 이용한 정밀 측위)

  • Bae, Tae-Suk
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.2
    • /
    • pp.201-208
    • /
    • 2011
  • With the increase in the number of smartphone users, precise 3D positional information is required by various applications. The positioning accuracy using civilian single-frequency pseudoranges is at the level of 10 m or so, but most applications these days are asking for a sub-meter level Therefore, instead of an absolute positioning technique, the VRS-based differential approach is applied along with the correction of the double-differenced (DD) residual errors using FKP (Flachen-Korrektur-Parameter). The VRS (Virual Reference Station) is located close to the rover, and the measurements are generated by correcting the geometrical distance to those of the master reference station. Since the unmodeled errors are generally proportional to the length of the baselines, the correction parameters are estimated by fitting a plane to the DD pseudorange errors of the CORS network. The DD positioning accuracy using 24 hours of C/A code measurements provides the RMS errors of 37 cm, 28 cm for latitudinal and longitudinal direction, respectively, and 76 cm for height. The accuracy of the horizontal components is within ${\pm}0.5m$ for about 90% of total epochs, and in particular the biases are significantly decreased to the level of 2-3 cm due to the network-based error modeling. Consequently, it is possible to consistently achieve a sub-meter level accuracy from the single-frequency pseudoranges using the VRS and double-differenced error modeling.

Characterization of Summertime Aerosol Particles Collected at Subway Stations in Seoul, Korea Using Low-Z Particle Electron Probe X-ray Microanalysis

  • Kim, Bo-Wha;Jung, Hae-Jin;Song, Young-Chul;Lee, Mi-Jung;Kim, Hye-Kyeong;Kim, Jo-Chun;Sohn, Jong-Ryeul;Ro, Chul-Un
    • Asian Journal of Atmospheric Environment
    • /
    • v.4 no.2
    • /
    • pp.97-105
    • /
    • 2010
  • A quantitative single particle analytical technique, denoted low-Z particle electron probe X-ray microanalysis (low-Z particle EPMA), was applied to characterize particulate matters collected at two underground subway stations, Jegidong and Yangje stations, in Seoul, Korea. To clearly identify the source of the indoor aerosols in the subway stations, four sets of samples were collected at four different locations within the subway stations: in the tunnel; at the platform; near the ticket office; nearby outdoors. Aerosol samples collected on stages 2 and 3 ($D_p$: $10-2.5\;{\mu}m$ and $2.5-1.0\;{\mu}m$, respectively) in a 3-stage Dekati $PM_{10}$ impactor were investigated. Samples were collected during summertime in 2009. The major chemical species observed in the subway particle samples were Fe-containing, carbonaceous, and soil-derived particles, and secondary aerosols such as nitrates and sulfates. Among them, Fe-containing particles were the most popular. The tunnel samples contained 85-88% of Fe-containing particles, with the abundance of Fe-containing particles decreasing as the distances of sampling locations from the tunnel increased. The Fe-containing subway particles were generated mainly from mechanical wear and friction processes at rail-wheel-brake interfaces. Carbonaceous, soil-derived, and secondary nitrate and/or sulfate particles observed in the underground subway particles likely flowed in from the outdoor environment by human activities and the air-exchange between the subway system and the outdoors. In addition, since the platform screen doors (PSDs) limit air-mixing between the tunnel and the platform, samples collected at the platform at the Yangjae station (with PSDs) showed a marked decrease in the relative abundances of Fe-containing particles compared to the Jegidong station (without PSDs).

A Study on the Development of the Single Station Fixed Temperature Detector of Low Power Consumption for Residential Fire Prevention (주택화재 예방을 위한 저소비 전력형 단독경보형 정온식감지기 개발에 관한 연구)

  • Park, Se-Hwa;Cho, Jae-Cheol
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.61-68
    • /
    • 2010
  • In this paper, a research and development result for the implementation of single station fixed temperature detector for residential fire prevention is described. The detector was developed for the certification in Japanese market because of very low domestic market situation. It is in the situation that there is no other regulation especially for residential detectors in Korea, Japanese case has been reviewed. Investigation of domestic legal circumstances and a comparative study for the test standard owned by KFI (Korea Institute of Fire Industry & Technology) and JFEII (Japan Fire Equipment Inspection Institute) respectively are also indicated. The detector alarms with a buzzer and an indicating LED. In the implementation ultra low power MCU(Micro Controller Unit) is applied to control the sleeping state and the monitoring state properly with low current consumption. To sense the temperature fast response thermistor is adopted in the design of fixed temperature residential detector. Automatic test function and alarm stop function are also considered in the design. The major factors which influence to current consumption are explained for the purpose of design reference. Main electronics circuit parts related to it's characteristics of the detector are described. It is explained that the measured current and experimental result of the battery discharge can be met over 10 years operation.

Determination of the Hypocentral Parameters Outside The Seismic Array Using a Single Station of Three-Component (지진관측망 밖의 진원결정과 3-성분 단일 지진관측에 관해서)

  • 김소구;이승규
    • The Journal of Engineering Geology
    • /
    • v.5 no.1
    • /
    • pp.59-74
    • /
    • 1995
  • It is well known that the hypocentral parameters inside the seismic array are well determined using HYPO71PC Programs. These programs, however, do not woik well for the non-evenly distribution of the seismic stations and/or the seismic events outside the seismic array. Furthermore it is very difficult to determine the exact locations of small events in North Korea since there is no seismological data exchange between South and North Koreas. We used the polarization method of the single-station with 3-component in addition to HYPO71PC(IASPEI's Program) in order to determine the source parameters of shallow-focus earthquakes outside the seismic array. First of all, we tested the interior events of the Uisung earthquake, April 14, 1991 and the Mt. Keyryong earthquakes, Feorirary 12, 1994, and two exterior events of W. Pyoungyang earthquake, Noventer 12, 1992, and Yellow Sea earthquake, July 26, 1994 to investigate the convergence and divergence to calculate the source parameters. We have found that the source determination outside the seismic array never converges to the exact location whereas the any events inside the array quickly converge to the exact location. The seismic events outside the array such as two events Vladivostok and East Sea, and the Yellow Sea event are more accurately determined using the polarization method. Estimating the source azimuth is carried out by estimating the polarization direction of the interesting phases and the range estimate is made frum the relative timing of different phases. The polarization method is verified by fmding that the estimates of azimuths and incidence angles by the polarization method are identical with those of the synthetic seismograms of the modellings using the generator program.

  • PDF

A Study on the Relation between the Single-track Subway and Housing Price - Focused on Row and Multi-family House around Eungam Loop Line of Seoul Subway Line 6 - (단선 일방통행 방식의 지하철과 주택가격의 관계 분석 - 서울 지하철 6호선 응암순환선 구간 주변 연립다세대를 중심으로 -)

  • So, Soung-Kue;Oh, Sae-Joon;Lee, Kyu-Tai
    • Journal of Cadastre & Land InformatiX
    • /
    • v.49 no.2
    • /
    • pp.39-56
    • /
    • 2019
  • In this study, we analyzed the effect of the Eungam Loop Line of Seoul Subway Line 6 on the sale price of adjacent row and multi-family houses on the accessibility and structural characteristics of subway stations. This study empirically analyzed a total of 17,938 cases from 2006 to 2017 based on data on the sale price of row and multi-family houses. In summary, the results of this study using the Hedonic Price Model are as follows. First, this study confirms that the Eungam Loop Line characteristics have a positive effect on the sale price as it is adjacent to the subway station. It is noteworthy that the sale price of 100-200m segment has a positive effect, and the sale price of Bulgwang station, which has excellent mobility and connectivity with CBD, YBD and GBD, has a positive effect. Second, this study shows the locational characteristics such as distance to bus stop, distance to mart, and distance to school have influence on the sale price. Third, this study finds the land characteristics such as land area, land shape, land facing, and road width, have significant effects on the sale price. Fourth, this study discovers the sale price is also is also affected by building and floor characteristics such as the type of housing, building area, the number of households, building age, elevator, and floor level.

Effect of Carbofuran on Rice Growth (식물생장조절제(植物生長調節劑) Carbofuran이 벼 생육(生育)에 미치는 영향(影響))

  • Kim, Soon-Chul
    • Korean Journal of Weed Science
    • /
    • v.7 no.1
    • /
    • pp.98-106
    • /
    • 1987
  • The effect of carbofuran (2, 3-Dihydro-2,2-dimethyl-benzofuran-7-ylmethyl carbamate) on rice growth was evaluated as a direct growth stimulant of rice. For this, several laboratory and field trials conducted from 1981 to 1986 at the Yeongnam Crop Experiment Station. Carbofuran solution affected the germination of rice seed. The growth of seminal roots was adversely affected by the increase of carbofuran concentrations while the length of single root became longer with the concentration increment up to 50 ppm. Carbofuran application (0.18g ai/$m^2$) at the rice nurserybed significantly enhanced the rice growth and recovered from the Low temperature damage. The enhancement effect was more pronounced at the plot that applied carbofuran before rice seeding as soil incorporation than top-dressing. The effect of growth enhancement further extended to transplanted lowland rice. This effect was greater at double cropping area (late of June transplanting) compared to single cropping area (May transplanting). Among important agronomic traits, the increment of panicle number was the most important direct effect for increasing rice grain yield by carbofuran application. Carbofuran application also exhibited the reducing effect against low temperature damage at reductive division stage and at rice heading stage and against submergence damage at booting stage through enhancement of fertile grain ratio, ripening ratio or photosynthetic activity.

  • PDF