• Title/Summary/Keyword: Single restoration

Search Result 354, Processing Time 0.025 seconds

Esthetic rehabilitation of single anterior edentulous space using fiber-reinforced composite

  • Kim, Hyeon;Song, Min-Ju;Shin, Su-Jung;Lee, Yoon;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.3
    • /
    • pp.220-225
    • /
    • 2014
  • A fiber-reinforced composite (FRC) fixed prosthesis is an innovative alternative to a traditional metal restoration, as it is a conservative treatment method. This case report demonstrates a detailed procedure for restoring a missing anterior tooth with an FRC. A 44-year-old woman visited our department with an avulsed tooth that had fallen out on the previous day and was completely dry. This tooth was replanted, but it failed after one year. A semi-direct technique was used to fabricate a FRC fixed partial prosthesis for its replacement. The FRC framework and the pontic were fabricated using a duplicated cast model and nanofilled composite resin. Later on, interproximal contact, tooth shape, and shade were adjusted at chairside. This technique not only enables the clinician to replace a missing tooth immediately after extraction for minimizing esthetic problems, but it also decreases both tooth reduction and cost.

Color image restoration for a single-CCD color camcorder system (단일 CCD 컬러 캠코더 시스템을 위한 컬러 영상복원)

  • Na, Woon;Park, Yong-Cheol;Paik, Joon-Ki
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.6
    • /
    • pp.1398-1415
    • /
    • 1996
  • Instead of using three charge-coupled devices (CCDs) for the corresponding color channels, most consumer's most consummer's color macmorders reconstruct color images by using only one CCD with a color filter array (CFA), which periodically samples different color signals. By this reson the resulting image cannot produce the full resolution of the input image. More sepecifically, a single-CCD color camcorder reconstructs red, greed, and blue color channels from a color filter array followed by a CCD. During the reconstruction process, color cross-talk among channels (interchannel distortion) and eriodically space-verying blur (intrachannel distortion) occur. The proposed restoration system reduces distortions due to interchannel interference, and then restores each color channel by removing the corresponding intrachannel distortion. Experimental results show that the proposedsystem provides the improved image in oth objective and subjective senses. A major advantage of the proposed system is feasible to real-time image improvement because it can be implemented by a finite impulse response (FIR) filter structure.

  • PDF

Spatial Frequency Adaptive Image Restoration Using Wavelet Transform (웨이브릿 변환을 이용한 공간주파수 적응적 영상복원)

  • 우헌배;기현종;정정훈;신정호;백준기
    • Journal of Broadcast Engineering
    • /
    • v.8 no.2
    • /
    • pp.204-208
    • /
    • 2003
  • In this paper, a new matrix vector formulation for a wavelet-based subband decomposition is introduced. This formulation provides a means to compute a regular multi-resolution analysis over many levels of decomposition. With this approach. any single channel linear space-invariant filtering problem can be cast into a multi-channel framework. This decomposition Is applied to the linear space-invariant image restoration problem and propose a frequency-adaptive constrained least squares(CLS) filter. In the proposed filter, we use different parameters adaptively according to subband characteristics. Experimental results are presented for the proposed frequency-adaptive CLS filter These experiments show that if accurate estimates of the subband characteristics are available, the proposed frequency adaptive CLS filter provides significant improvements over the traditional single channel filter.

An Auto-drawing Algorithm for the Single Line Diagram of Distribution Systems (배전선로 회선별단선도 자동생성 알고리즘)

  • Son, Ju-Hwan;Lim, Seong-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.5
    • /
    • pp.854-859
    • /
    • 2010
  • Distribution Automation System(DAS) is designed to improve operational efficiency by acquisition and control of remote data using its components such as central computation units, communication network and feeder remote terminal units. A conventional human machine interface of the DAS adopts a schematic diagram which is made by drawing power equipments on the geographic information system map. The single line diagram is more useful than the schematic diagram for the main tasks of distribution system operation such as protective relay coordination, service restoration and loss minimization. Since the configuration of the distribution line is changed according to the relocation of the open tie switches, the auto-drawing algorithm based on the connection between the sections and the switches is an essential technique. This paper proposes a new auto-drawing algorithm for a single line diagram of distribution systems based on tertiary tree and collision avoidance method. The feasibility of the proposed algorithm has been testified for various cases using practical distribution system with 12 feeders.

Retinex-based Logarithm Transformation Method for Color Image Enhancement (컬러 이미지 화질 개선을 위한 Retinex 기반의 로그변환 기법)

  • Kim, Donghyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.9-16
    • /
    • 2018
  • Images with lower illumination from the light source or with dark regions due to shadows, etc., can improve subjective image quality by using retinex-based image enhancement schemes. The retinex theory is a method that recognizes the relative lightness of a scene, rather than recognizing the brightness of the scene. The way the human visual system recognizes a scene in a specific position can be in one of several methods: single-scale retinex, multi-scale retinex, and multi-scale retinex with color restoration (MSRCR). The proposed method is based on the MSRCR method, which includes a color restoration step, which consists of three phases. In the first phase, the existing MSRCR method is applied. In the second phase, the dynamic range of the MSRCR output is adjusted according to its histogram. In the last phase, the proposed method transforms the retinex output value into the display dynamic range using a logarithm transformation function considering human visual system characteristics. Experimental results show that the proposed algorithm effectively increases the subjective image quality, not only in dark images but also in images including both bright and dark areas. Especially in a low lightness image, the proposed algorithm showed higher performance improvement than the conventional approaches.

Restoring Turbulent Images Based on an Adaptive Feature-fusion Multi-input-Multi-output Dense U-shaped Network

  • Haiqiang Qian;Leihong Zhang;Dawei Zhang;Kaimin Wang
    • Current Optics and Photonics
    • /
    • v.8 no.3
    • /
    • pp.215-224
    • /
    • 2024
  • In medium- and long-range optical imaging systems, atmospheric turbulence causes blurring and distortion of images, resulting in loss of image information. An image-restoration method based on an adaptive feature-fusion multi-input-multi-output (MIMO) dense U-shaped network (Unet) is proposed, to restore a single image degraded by atmospheric turbulence. The network's model is based on the MIMO-Unet framework and incorporates patch-embedding shallow-convolution modules. These modules help in extracting shallow features of images and facilitate the processing of the multi-input dense encoding modules that follow. The combination of these modules improves the model's ability to analyze and extract features effectively. An asymmetric feature-fusion module is utilized to combine encoded features at varying scales, facilitating the feature reconstruction of the subsequent multi-output decoding modules for restoration of turbulence-degraded images. Based on experimental results, the adaptive feature-fusion MIMO dense U-shaped network outperforms traditional restoration methods, CMFNet network models, and standard MIMO-Unet network models, in terms of image-quality restoration. It effectively minimizes geometric deformation and blurring of images.

Risk indicators associated with peri-implant diseases: a retrospective cross-sectional study of Colombian patients with 1 to 18 years of follow-up

  • Ana Maria Ortiz-Echeverri;Carolina Gallego-Gonzalez;Maria Catalina Castano-Granada;Sergio Ivan Tobon-Arroyave
    • Journal of Periodontal and Implant Science
    • /
    • v.54 no.3
    • /
    • pp.161-176
    • /
    • 2024
  • Purpose: Peri-implant mucositis (PIM) and peri-implantitis (PI) are multicausal conditions with several risk factors contributing to their pathogenesis. In this study, we retrospectively investigated risk variables potentially associated with these peri-implant diseases (PIDs) over a follow-up period of 1 to 18 years. Methods: The study sample consisted of 379 implants placed in 155 patients. Single-visit clinical and radiographic evaluations were employed to determine the presence or absence of PIDs. Parameters related to the patient, site, surgery, implant, and prosthetic restoration were documented. The relationships between risk variables and the occurrence of PIDs were individually examined and adjusted for confounders using multivariate binary logistic regression models. Results: The prevalence rates of PIM and PI were 28.4% and 36.8% at the patient level and 33.5% and 24.5% at the implant level, respectively. Poor oral hygiene, active gingivitis/periodontitis, preoperative alveolar ridge deficiency, early or delayed implant placement, implant length of 11.0 mm or less, and poor restoration quality were strong and independent risk indicators for both PIDs. Furthermore, a follow-up period of more than 5 years and a loading time of more than 4 years were important indicators for PI. Simultaneously, age and smoking status acted as modifiers of the effect of mesiodistal (MD) and buccolingual (BL) widths of restoration on PI. Conclusions: In this study population, oral hygiene, periodontal status, preoperative alveolar ridge status, implant placement protocol, implant length, and the quality of coronal restoration appear to be robust risk indicators for both PIM and PI. Additionally, the length of follow-up and functional loading time are robust indicators of PI. Furthermore, the potential modifying relationships of age and smoking status with the MD and BL widths of restoration may be crucial for the development of PI.

Single and Double-row Repair in Rotator Cuff Tears (회전근 개 파열의 일열 봉합술과 이열 봉합술)

  • Park, Jin-Young;Choi, Jin-Hyung;Park, Hong-Keun;Yu, Je-Wook;Seo, Joong-Bae
    • Clinics in Shoulder and Elbow
    • /
    • v.9 no.1
    • /
    • pp.89-95
    • /
    • 2006
  • Purpose: Arthroscopic repair of rotator cuff tears are many techniques that have been developed to improve the initial postoperative strength of the repair. There was a doubt that current arthroscopic cuff repairs using a single row of suture anchors reproduce insufficient area of the anatomic cuff insertion, and concerns about failure of fixation often lead surgeons to limit early motion. Newer technique of double-row repair in arthroscopic treatment may provide initial stronger fixation and more contact with bone at the repair site than single-row repair did. We studied the comparison between clinical outcomes of arthroscopic single- and double-row repair in cuff tears at 1year postoperatively. Materials and methods: We retrospectively analyzed 40 shoulders with single-row repair and 38 shoulders with double-row repair of full-thickness rotator cuff tears between May 2002 and October 2004. Out of total 78 shoulders, 42 (54%) were male patients and 36 (46%) were female patients and the mean age at surgery was 56 years. All patients were diagnosed by physical examination and MRI. At 1year' follow-up after operation, we evaluated with the ASES and the Constant scoring system, and measured muscle power of abduction, internal and external rotation of the affected shoulder then compared with each other. Results: Mean ASES scores and Constant scores in double-row repair group improved more than single-row repair group significantly at 1year postoperatively. Muscle power of abduction and internal rotation, especially abduction power, improved more significantly in double-row repair group than in single-row repair. Conclusion: Arthroscopic double-row repair for the full thickness rotator cuff tear may be a superior technique, which showed better clinical outcomes and restoration of muscle power compared with single-row repair at relatively short period of postoperative follow-up. Restoration of footprint close to normal anatomy by double-row repair seems to play an important role in the recovery of muscle strength.

THE EFFECTS OF PHOTOPOLYMERIZATION OF ADHESIVE ON SHEAR BOND STRENGTH AND MICROLEAKAGE OF FLOWABLE RESIN RESTORATION (유동성 레진 수복술에서 접착제 중합 여부에 따른 미세누출과 전단결합강도에 관한 연구)

  • Park, Yong-Kyu;Kim, Jong-Soo;Yoo, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.3
    • /
    • pp.398-407
    • /
    • 2007
  • This study was performed to evaluate possibility to reduce treatment time for child patient who have limited control activity during flowable composite resin restoration according to comparing microleakage and shear bond strength. Group I, II with Single $Bond^{TM}$, group III, IV with AQ Bond $Plus^{TM}$, group V, VI with Prompt L-$Pop^{TM}$, and group VII as control group without adhesive system. 12 premolars and 10 molars were assigned into each group. Restorative material was used the Filtek $Z350^{TM}$ flowable. The results were as follows; 1. The result of microleakage evaluation, in the group I, II with Single $Bond^{TM}$ showed low dye penetration score. Dye penetration between group I and group II were similar. 2. Results for shear bond strength at group I and group II showed values higher than other groups. (p<0.05) There were no statistical differences between group I and group II. (p>0.05) 3. There was no statistical differences among I and II, III and IV, V and VI groups. 4. Group VII showed significantly low shear bond strength than group I, II, V, VI(p<0.05). Group VII showed low value than group with III and IV, but no statistical significances. In conclusion, adhesive bonding resin was not affect significantly to microleakage and shear bond strength of flowable resin restoration. Therefore, to reduce the operation time, adhesive bonding resin and flowable composite resin can be cured at once. But contamination of saliva, location of cavities can affect to bond strength in clinical field.

  • PDF