• Title/Summary/Keyword: Single restoration

Search Result 354, Processing Time 0.037 seconds

The Comparison between the success rates of single implants replacing the mandibular first and second molar (하악 제1, 2 대구치를 대체하는 단일 임프란트 간의 성공률 비교)

  • Lee, Hang-Bin;Paik, Jung-Won;Kim, Chang-Sung;Choi, Seong-Ho;Lee, Keun-Woo;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.1
    • /
    • pp.101-112
    • /
    • 2004
  • Osseointegrated implnats have proven to be successful in both full and partial edentulous patients since the 1960s and recently have shown successful results when used to restore single tooth missing. However, in most studies reporting the success of single implants, single implants replacing anterior teeth are more frequently mentioned than posterior single implants. Moreover, in studies regarding posterior single implants, the replaced region seemed to be variable; the maxilla, mandible and areas from the first premolar to the second molar were mentioned. However, considering the difference in bone quality in the mandible and maxilla, and the increased occlusal force in the posterior region, the success rates in each region may be different. In this study, the cumulative success rates and amount of bone loss of single implants replacing the mandibular first and second molar, respectively, were compared and analyzed to come to the following conclusion. 1. The 20 (20 persons) single implants that were placed in the mandibular first molar region were all successful and showed a 100% 5 year cumulative success rate. Among the 27 (24 persons) single implants replacing the mandibular second molar, 8 failed (27.63%) showing a 5 year cumulative success rate of 70.37%. 2. Among the 8 failed implants, one showed symptoms of postoperative infection and one complained of parenthesia. 6 implants failed after functional loading; 5 showed mobility and one resulted in fixture fracture. 3. After the attachment of the prosthesis, there was no significant statistical difference regarding the marginal bone loss in group 1 and group 2 during the checkup period (P>0.05). In conclusion, restoration of the mandibular first molar using single implants was found to be an excellent treatment modality, and when replacing mandibular second molars with single implants, poor bone quality and risk of overloading must be considered.

THE INFLUENCE OF IRM TEMPORARY RESTORATIONS ON MARGINAL MICROLEAKAGE OF DENTIN ADHESIVES (IRM 임시수복이 상아질 접착제의 변연 미세누출에 미치는 영향)

  • Cho, Young-Gon;Kim, Hyun-Kyung;Lee, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.1
    • /
    • pp.1-10
    • /
    • 2003
  • This study investigated the influence of IRM on marginal microleakage of 5th generation adhesives. Class V cavities with gingival margins in dentin were prepared on both buccal and lingual surfaces of 60 extract-ed human molar teeth. Prepared teeth were randomly divided into six groups. Group 1 and 4 received no temporary restoration with IRM. Group 2 and 5 were covered with IRM mixed at P/L ratio(10g/1g). Group 3 and 6 were covered with IRM mixed at P/L ratio(10g/2g). The temporary restorations were removed mechanically with an ultrasonic scaler after one-week storage in distilled water. The cavities were restored using one of two adhesives and composites ; Single Bond/Filtek Z 250(Croup 1, 2 and 3), UniFil Bond/UniFil F(Group 4, 5 and 6). Following one day storage in distilled water, the restored teeth were thermocycled for 500 cycles(between $5^{\circ}C{\;}and{\;}55^{\circ}C$) and immersed in 2 % methylene blue for dye penetration testing. The results were analysed using Kruskal-Wallis Test, Mann-Whitney and Wilcoxon signed ranked test at a significance level of 0.05. The results of this study were as follows 1. Ranking of mean microleakage scores at the enamel margins was Group 10.05) 4. At the dentin margins, the microleakage of the group not pretreated with IRM was lower than that of the group pretreated with IRM. And the microleakage of UniFil Bond was lower than that of Single Bond. 5. Compared with microleakages between the enamel and dentin margins of each groups, Group 1, 2, 3, 4, 5 and 6 at dentin margin were higher microleakage than those at enamel margin. There were significant difference between enamel and dentin microleakage of Group 2 and 3(p<0.05).

THREE-DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF SINGLE IMPLANT RESTORATION USING DIFFERENT FIXTURE AND ABUTMENT SCREW DIAMETERS (단일치 임플랜트 지지 보철물에서 고정체와 지대주 나사 직경의 차이에 따른 삼차원 유한요소법적 응력 분석)

  • Kwon Joo-Hong;Choi Min-Ho;Kim Yu-Lee;Cho Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.105-119
    • /
    • 2005
  • Statement of problem. As the effects of the various diameters of fixture and abutment screw on stress distribution was not yet examined, this study focused on the different design of single implant restoration using three dimensional finite element analysis. Purpose. This study was to compare five different fixture-abutment combinations for single implant supported restorations with different fixture and abutment screw diameters. Material of methods. The five kinds of finite element models were designed by 3 diameter fixtures ($\oslash$3.3, 3.75, 5.0 mm) with 3 different abutment screws $\oslash$1.5, 1.7, 2.0 mm). The crown for mandibular first molar was made using UCLA abutment according to Wheeler's anatomy. 244 N was applied at the central fossa with two different loading directions, vertically and obliquely (30$^{\circ}$) and at the buccal cusp vertically. Maximum von Mises stresses were recorded and compared in the supporting bone, crowns, fixtures, and abutment screws. Results. 1. The stresses in supporting bone and implant-abutment structure under oblique loading were greater than those under vertical or offset loading. The stresses under vertical loading were the least among 3 loading conditions regardless of the implant and abutment screw diameters. 2. The stresses in the narrow implants were greater than the wider implants. The narrow implant with narrow abutment screw showed highest stresses in the lingual crest, but the narrow implant with standard abutment screw showed highest stress in abutment screw. 3. The stresses of abutment screws were influenced by the diameter of fixtures and loading conditions. The wide implants showed least difference between two different abutment screw diameters. Conclusions. The wide implants showed lesser stresses than the narrow implants and affected least by the different abutment screw diameters. The narrow implants with standard abutment screw showed highest stresses in the lingual bony crest under oblique loading.

Habitat Restoration Initiative for Endangered Species Parnassius bremeri (Lepidoptera: Papilionidae) in Korea (멸종위기종 붉은점모시나비의 서식지 복원구상)

  • Kim, Do-Sung;Park, Seong-Joon;Shin, Young-Kyu;Park, Doo-Sang
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.39 no.6
    • /
    • pp.98-109
    • /
    • 2011
  • Habitat restoration initiative is an important factor for the on-site preservation of butterflies. A new habitat necessitates the investigation of the ecology of the butterfly, the landscape of the habitat, the work process, and a cost analysis. In this study, these factors were analyzed through1) re-consideration of the secured results from three years of field work, and 2) a habitat area estimation conducted according to the presence or absence of larvae and adults via a Parnassius bremeri Bremer survey. The investigation of the natural habitat, done for both larvae and adult butterflies found in South Korea, suggested that multiple patches with a minimum size exceeding $300m^2$ and with an average size of about $1,600m^2$were required for survival of this butterfly. Therefore, more than five patches should be considered for butterfly habitat and patches should have similarity to the present habitat environment with transplantation plans for diet plants and honeydew plants. In addition, to activate the migration of the butterfly, cutting down trees that are obstacles to migration, minimizing the distance between patches and the addition of a stepping patch are also required. A patch connectivity analysis showed that patches should be located within 300m of neighboring patches, as the migration of the butterfly will fail if it is more than 600m. Additionally, more than $10,000m^2$ for a single patch or a patch network composed more than five patches over $1,600m^2$ in size were recommended, with a total patch size of $8,000m^2$. Additionally, neighboring multiple patch networks are more desirable than a single habitat in the event a cyclic habitat pattern arises. In this study, we suggest a habitat restoration and optimal prerequisites for a butterfly habitat. It is expected that this research will lead to the creation of a good model for the restoration of butterfly species.

Computer-guided implant surgery and immediate provisionalization by chair-side CAD-CAM: A case report (진료실 CAD-CAM에 의한 컴퓨터 가이드 임플란트 수술과 즉시 임시보철치료: 증례보고)

  • Hyun, Sang Woo;Lee, sungbok Richard;Lee, Suk Won;Cho, Young Eun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.478-486
    • /
    • 2021
  • This report demonstrates a method of generating a chair-side and computer-aided template for implant surgery based on the Top-Down and restoration-driven concept. Compared to the traditional CAD-CAM process which requires multiple steps to be taken between dental clinic and laboratory, this alternative procedure, VARO guide system (VARO Guide, CAD, Pre-Guide, VARO-mill, NeoBiotech, Seoul, South Korea) enables accurate and patient-friendly implant surgery as well as immediate provisional restoration in a single visit. First, bite-registration at centric jaw relation and CBCT were taken using the Pre-Guide. The CBCT data was then reorganized directly through the chair-side CAD, and we could determine the most appropriate 3-dimensional position of implant. The STL file was extracted and put into the chair-side CAM (VARO-mill) to fabricate a VARO. This surgical guide allowed the implants to be accurately positioned into the planned sites within an hour.

A Study on the Development of "Bufo gargarizans" Habitat Suitability Index(HSI) (두꺼비 서식지 적합성 지수(HSI) 모델개발을 위한 연구)

  • Cho, Gun-Young;Koo, Bon-Hak
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.25 no.2
    • /
    • pp.23-38
    • /
    • 2022
  • This study investigates the characteristics and physical habitat requirements for each Bufo gargarizans life history through a literature survey. After deriving variables for each component of Bufo gargarizans, in order to reduce regional deviations from eight previously studied literature research areas for deriving the criteria for variables, a total of 12 natural habitats of Bufo gargarizanss are selected as spatial ranges by selecting four additional sites such as Umyeonsan Ecological Park in Seoul, Wonheungibangjuk in Cheongju in the central region, Changnyeong Isan Reservoir in the southern region, and Mangwonji in Daegu. This study presents Bufo gargarizans SI, a species endemic to Korea, whose population is rapidly declining due to large-scale housing site development and road development, and develops a Bufo gargarizans HSI model accordingly to improve the function of the damaged Bufo gargarizans habitat and to present an objective basis for site selection of alternative habitat. At the same time, it provides basic data for adaptive management and follow-up monitoring. The three basic habitat requirements of amphibians, the physical habitat requirements of Bufo gargarizans, synthesized with shelter, food, and water, and the characteristics of each life history, are classified into five components by adding space and threats through literature research and expert advice. Variables are proposed by synthesizing and comparing the general characteristics of amphibians, among the previously studied single species of amphibians, the components of HSI of goldfrogs and Bufo gargarizans, and the ecological and physical environmental characteristics of Bufo gargarizans. Afterwards, through consultation with an amphibian expert, a total of 10 variables are finally presented by adjacent forest area(ha), the distance between spawning area and the nearest forest land(m), the soil, the distance from the wetland(m), the forest layered structure, the low grassland space, the permanent wetland area(ha), shoreline slope(%), PH, presence of predators, distance from road(m), presence or absence of obstacles. n order to derive the final criteria for each of the 10 variables, the criteria(alternative) for each variable are presented through geographic information analysis of the site survey area and field surveys of the previously studied literature research area. After a focus group interview(FGI) of 30 people related to the Bufo gargarizans colony in Cheongju, a questionnaire and in-depth interviews with three amphibians experts are conducted to verify and supplement the criteria for each final variable. Based on the finally developed Bufo gargarizans HSI, the Bufo gargarizans habitat model is presented through the SI graph model and the drawing centering on the Bufo gargarizans spawning area

The Self-Sufficiency Experience of Korean-American Single Mothers with the History of Domestic Violence in Poverty (미국 한인 가정폭력피해 한부모 빈곤여성들의 자활 경험)

  • Chong, Hyesuk
    • Korean Journal of Social Welfare
    • /
    • v.65 no.4
    • /
    • pp.245-269
    • /
    • 2013
  • Self-sufficiency has been recognized as one of the most important welfare goals for women in the domestic violence field since the welfare reform in the U.S. A qualitative research design was conducted to explore the self-sufficiency experience of Korean-American single mothers with the history of domestic violence in poverty. The meaning of 'self-sufficiency' to participants is that a continuing task or process in life to move toward being independent mentally as well as economically. Their challenges toward self-sufficiency include the period of restoration of their potentials for self-sufficiency destroyed by domestic violence victimization and divorce, and the period of developing their sustainability for self-sufficiency. Their needs for 'help and support similar to care from the woman's parents' home', 'welfare service of select and concentration', 'mature dependency and self-sufficiency', and 'self-sufficiency from survival to dream come true' to cope with the challenges formentioned are reported. Concrete strategies for the development of self-sufficiency polices and services sensitive to immigrant single mothers with the history of domestic violence are suggested.

  • PDF

Errors in light-emitting diodes positioning when curing bulk fill and incremental composites: impact on properties after aging

  • Abdulrahman A. Balhaddad;Isadora M. Garcia;Haifa Maktabi;Maria Salem Ibrahim;Qoot Alkhubaizi;Howard Strassler;Fabricio M. Collares;Mary Anne S. Melo
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.4
    • /
    • pp.51.1-51.13
    • /
    • 2021
  • Objectives: This study aimed to evaluate the effect of improper positioning single-peak and multi-peak lights on color change, microhardness of bottom and top, and surface topography of bulk fill and incremental composites after artificial aging for 1 year. Materials and Methods: Bulk fill and incremental composites were cured using multi-peak and single-peak light-emitting diode (LED) following 4 clinical conditions: (1) optimal condition (no angulation or tip displacement), (2) tip-displacement (2 mm), (3) slight tip angulation (α = 20°) and (4) moderate tip angulation (α = 35°). After 1-year of water aging, the specimens were analyzed for color changes (ΔE), Vickers hardness, surface topography (Ra, Rt, and Rv), and scanning electron microscopy. Results: For samples cured by single-peak LED, the improper positioning significantly increases the color change compared to the optimal position regardless of the type of composite (p < 0.001). For multi-peak LED, the type of resin composite and the curing condition displayed a significant effect on ΔE (p < 0.001). For both LEDs, the Vickers hardness and bottom/top ratio of Vickers hardness were affected by the type of composite and the curing condition (p < 0.01). Conclusions: The bulk fill composite presented greater resistance to wear, higher color stability, and better microhardness than the incremental composite when subjected to improper curing. The multi-peak LED improves curing under improper conditions compared to single-peak LED. Prevention of errors when curing composites requires the attention of all personnel involved in the patient's care once the clinical relevance of the appropriate polymerization reflects on reliable long-term outcomes.

Frame Error Concealment Using Pixel Correlation in Overlapped Motion Compensation Regions

  • Duong, Dinh Trieu;Choi, Byeong-Doo;Hwang, Min-Cheol;Ko, Sung-Jea
    • ETRI Journal
    • /
    • v.31 no.1
    • /
    • pp.21-30
    • /
    • 2009
  • In low bit-rate video transmission, the payload of a single packet can often contain a whole coded frame due to the high compression ratio in both spatial and temporal domains of most modern video coders. Thus, the loss of a single packet not only causes the loss of a whole frame, but also produces error propagation into subsequent frames. In this paper, we propose a novel whole frame error concealment algorithm which reconstructs the first of the subsequent frames instead of the current lost frame to suppress the effects of error propagation. In the proposed algorithm, we impose a constraint which uses side match distortion (SMD) and overlapped region difference (ORD) to estimate motion vectors between the target reconstructed frame and its reference frame. SMD measures the spatial smoothness connection between a block and its neighboring blocks. ORD is defined as the difference between the correlated pixels which are predicted from one reference pixel. Experimental results show that the proposed algorithm effectively suppresses error propagation and significantly outperforms other conventional techniques in terms of both peak signal-to-noise ratio performance and subjective visual quality.

  • PDF

MARGINAL FIT OF THE AURO GALVANO CROWN SYSTEM MADE USING THE ELECTROFORMING TECHNIQUE

  • Yang Jae-Ho;Song Tae-Jin;Han Jung-Suk;Lee Jae-Bong;Lee Sun-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.6
    • /
    • pp.679-684
    • /
    • 2004
  • Statement of problem. There have been few studies about the marginal fit of Auro Galvano Crowns. Purpose. The purpose of this study was to compare the marginal fit of the anterior single restorations. Material and methods. The in vitro marginal discrepancies of metal-ceramic, Auro Galvano Crown and coping were evaluated and compared. The Auro Gavano Crowns were made from one extracted maxillary central incisor prepared by milling machine. 30crowns per each system were fabricated. Measurements of a crown were recorded at 50 points that were randomly selected for marginal gap evaluation. Parametric statistical analysis was performed for the results. Results. Mean marginal gap dimensions and standard deviations at the marginal opening for the anterior single crowns were $74{\pm}21{\mu}m$ for the control (metal-ceramic restoration), $45{\pm}11{\mu}m$ for Auro Galvano Crown coping, and $51{\pm}9{\mu}m$ for the Auro Galvano Crown. Conclusions. Auro Calvano Crown showed significantly smaller (P<.05) marginal gap than the control. Ceramic application did not significantly affected the marginal fit of Auro Galvano Crown. (P>.05)