• Title/Summary/Keyword: Single prosthesis

Search Result 133, Processing Time 0.028 seconds

Effect of initial placement level and wall thickness on maintenance of the marginal bone level in implants with a conical implant-abutment interface: a 5-year retrospective study

  • Yoo, Jaehyun;Moon, Ik-Sang;Yun, Jeong-Ho;Chung, Chooryung;Huh, Jong-Ki;Lee, Dong-Won
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.3
    • /
    • pp.185-192
    • /
    • 2019
  • Purpose: Implant wall thickness and the height of the implant-abutment interface are known as factors that affect the distribution of stress on the marginal bone around the implant. The goal of this study was to evaluate the long-term effects of supracrestal implant placement and implant wall thickness on maintenance of the marginal bone level. Methods: In this retrospective study, 101 patients with a single implant were divided into the following 4 groups according to the thickness of the implant wall and the initial implant placement level immediately after surgery: 0.75 mm wall thickness, epicrestal position; 0.95 mm wall thickness, epicrestal position; 0.75 mm wall thickness, supracrestal position; 0.95 mm wall thickness, supracrestal position. The marginal bone level change was assessed 1 day after implant placement, immediately after functional loading, and 1 to 5 years after prosthesis delivery. To compare the marginal bone level change, repeated-measures analysis of variance was used to evaluate the statistical significance of differences within groups and between groups over time. Pearson correlation coefficients were also calculated to analyze the correlation between implant placement level and bone loss. Results: Statistically significant differences in bone loss among the 4 groups (P<0.01) and within each group over time (P<0.01) were observed. There was no significant difference between the groups with a wall thickness of 0.75 mm and 0.95 mm. In a multiple comparison, the groups with a supracrestal placement level showed greater bone loss than the epicrestal placement groups. In addition, a significant correlation between implant placement level and marginal bone loss was observed. Conclusions: The degree of bone resorption was significantly higher for implants with a supracrestal placement compared to those with an epicrestal placement.

A retrospective randomized study of success rates according to abutment selection in DENTIS submerged implant with an internal hex connection (DENTIS 내부연결형 서브머지드 임플란트에서 지대주 선택에 따른 성공률의 후향적 연구)

  • Kim, Eun-Hee;Lee, Joeng-Eun;Hwang, Hee-Seong;Kim, Chul-Hoon;Kim, Jung-Han;Kim, Bok-Joo
    • The Journal of the Korean dental association
    • /
    • v.56 no.11
    • /
    • pp.605-614
    • /
    • 2018
  • PURPOSE. The purpose of this study is to determine the efficacy of the DENTIS submerged-type implant with an internal hex connection and to build corresponding abutment-selection criteria. MATERIAL AND METHODS. A total of 204 patients received submerged implant fixtures with an internal hex connection at the Dong-A University Hospital Dental clinic in Busan from January 2013 and May 2016. Three specific abutments, UCLA abutments, customized abutments, ready-made abutments, were randomly selected. Implant success was defined as the basis of the International Congress of Oral Implantologists(ICOI, 2007) criteria. The relationship between the implant success rate and the abutment factor was analyzed using the Kruskal-Wallis test(P<.05). RESULTS. A total of 508 implants were placed in 204 patients. After a mean observation period of 38.6 months, 493 out of 508 implants were in normal function, yielding an overall success rate of 97.05%. A total of 15 implants failed: 10 in the maxillary molar area, 4 in the mandibular molar area, and 1 in the mandibular incisal area. All of the implant failures occurred in a single-implant prosthesis, especially high in the maxillary molar area. The Kruskal-Wallis analysis showed that abutment selection has no significant correlation with implant failure(P>.05). CONCLUSION. DENTIS submerged implants with an internal hex connection showed predictable results with a success rate of 97.05%. It is no influence on the success rate in the selection of submerged implant abutment with an internal hex connection.

  • PDF

A case report of single crown restoration using an intraoral scanner for occlusal evaluation (단일 치관 수복 시 구강스캐너를 이용한 교합평가 활용 증례보고)

  • Song, Jun-Beom;Lee, Jong-Hyuk;Ha, Seung-Ryong;Choi, Yu-Sung;Choi, Sun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.341-349
    • /
    • 2021
  • The evaluation of occlusion using digital methods is easier and simpler in terms of recording, comparison, analysis, and objectivity compared to existing methods such as articulating paper and occlusion foil. The purpose of this case report was utilizing the digital method for evaluating occlusion. The occlusion of patient requiring full veneer crown restoration was evaluated using an intraoral scanner (i500, Medit, Seoul, Korea) at every visit. The occlusion was also assessed using conventional articulating paper and a digital occlusal analysis system (Dental prescale II, GC corp., Tokyo, Japan) for comparison. Throughout the treatment process, the intraoral scanner and the conventional articulating paper method showed similar outcomes. The results suggest that the use of digital evaluation system is highly probable in the near future.

Influence of zirconia and titanium fixture materials on stress distribution in abutment screws: a three-dimensional finite element analysis (지르코니아 및 티타늄 고정체 소재가 지대주 나사의 응력 분포에 미치는 영향: 3차원 유한 요소 분석)

  • Kim, Eun Young;Hong, Min-Ho
    • Journal of Technologic Dentistry
    • /
    • v.43 no.2
    • /
    • pp.42-47
    • /
    • 2021
  • Purpose: The purpose of this study was to evaluate the stability of abutment screws used with the zirconia fixture-based implant system and compare them with those used with the existing titanium fixture system via the finite element method. Methods: A single implant-supported restoration was designed for the finite element analysis. A universal analysis program was used to set 8 occlusal points along the direction to the long axis of the implant, and an occlusal load of 700 N was applied. Results: In all models (Zir and Ti-fixture model), the screw threads presented with the highest von Mises stress (VMS) values, whereas the head and end presented with the lowest VMS values. The VMS of the screw used in the zirconia-fixture model was 5.97% lower than that used in the titanium-fixture model (261.258 vs. 276.911 MPa, respectively) despite statistical significance. Furthermore, the zirconia fixture (352.912 MPa) had a higher stress value (8.42%) than the titanium fixture (332.331 MPa). In a completely tightened titanium fixture implant system, the stress was concentrated in the implant-abutment connection interface, the zirconia fixture presented with a stable stress distribution. Conclusion: Although the zirconia fixture demonstrated a high VMS value, owing to the stiffness and elasticity coefficients of the material, the stress generated in the abutment screws was similar in all models. In conclusion, the zirconia fixture-based implant system presented with a more stable stress distribution in the abutment screws than the titanium fixture-based implant system.

A retrospective comparison of clinical outcomes of implant restorations for posterior edentulous area: 3-unit bridge supported by 2 implants vs 3 splinted implant-supported crowns

  • Yi, Yuseung;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.4
    • /
    • pp.223-235
    • /
    • 2022
  • PURPOSE. To compare the clinical outcomes of two types of implant restoration for posterior edentulous area, 3-unit bridge supported by 2 implants and 3 implant-supported splinted crowns. MATERIALS AND METHODS. The data included 127 implant-supported fixed restorations in 85 patients: 37 restorations of 3-unit bridge supported by 2 implants (2-IB), 37 restorations of 3 implant-supported splinted crowns (3-IC), and 53 single restorations (S) as controls. Peri-implantitis and mechanical complications that occurred for 14 years were analyzed by multivariable Cox regression model. Kaplan-Meier curves and the multivariable Cox regression model were used to analyze the success and survival of implants. RESULTS. Peri-implantitis occurred in 28.4% of 2-IB group, 37.8% of 3-IC group, and 28.3% of S control group with no significant difference. According to the implant position, middle implants (P2) of the 3-IC group had the highest risk of peri-implantitis. The 3-IC group showed a lower mechanical complication rate (7.2%) than the 2-IB (16.2%) and S control group (20.8%). The cumulative success rate was 52.8% in S (control) group, 62.2% in 2-IB group, and 60.4% in 3-IC group. The cumulative survival rate was 98.1% in S (control) group, 98.6% in 2-IB group, and 95.5% in 3-IC group. There was no significant difference in the success and survival rate according to the restoration type. CONCLUSION. The restoration type was not associated with the success and survival of implants. The risk of mechanical complications was reduced in 3 implant-supported splinted crowns. However, the middle implants of the 3 implant-supported splinted crowns had a higher risk of peri-implantitis.

Meshed Acellular Dermal Matrix for Two-Staged Prepectoral Breast Reconstruction: An Institutional Experience

  • Luo, Jessica;Willis, Rhett N. Jr;Ohlsen, Suzanna M.;Piccinin, Meghan;Moores, Neal;Kwok, Alvin C.;Agarwal, Jayant P.
    • Archives of Plastic Surgery
    • /
    • v.49 no.2
    • /
    • pp.166-173
    • /
    • 2022
  • The introduction of acellular dermal matrix (ADM) to breast reconstruction has allowed surgeons to reexplore the prepectoral implant placement technique in postmastectomy breast reconstruction. Our institution adopted a novel approach using meshed ADM to lessen the financial burden of increased ADM utilization with the prepectoral breast reconstruction. This is a retrospective, single-center review of two-stage prepectoral breast reconstruction using meshed human-derived ADM for anterior prosthesis coverage. Patient demographics, oncologic data, perioperative characteristics, and complications were examined and reported as means with standard deviations. Cost-saving with the meshed technique was evaluated. Forty-eight patients (72 breasts) with a mean age of 48.5 ± 15.0 years (range 26-70 years) were included in the study. The mean follow-up time was 13.2 ± 4.4 months (range 4.1-25.8 months). Nineteen breasts (24.6%) experienced complications, with seromas being the most common complication (12.5%, n = 9). Expander removal and reoperation occurred at a rate of 8.3 and 9.7%, respectively. The average time to drain removal was 18.8 ± 6.6 days (range 8-32 days). Meshed ADM provided an average cost savings of $6,601 for unilateral and $13,202 for bilateral reconstructions. Our study found that human-derived meshed ADM can be safely used in two-staged prepectoral tissue expander-based breast reconstruction and can result in significant cost savings.

Anatomic total shoulder arthroplasty with a nonspherical humeral head and inlay glenoid: 90-day complication profile in the inpatient versus outpatient setting

  • Andrew D. Posner;Michael C. Kuna;Jeremy D. Carroll;Eric M. Perloff;Matthew J. Anderson;Ian D. Hutchinson;Joseph P. Zimmerman
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.4
    • /
    • pp.380-389
    • /
    • 2023
  • Background: Total shoulder arthroplasty (TSA) with a nonspherical humeral head component and inlay glenoid is a successful bone-preserving treatment for glenohumeral arthritis. This study aimed to describe the 90-day complication profile of TSA with this prosthesis and compare major and minor complication and readmission rates between inpatient- and outpatient-procedure patients. Methods: A retrospective review was performed of a consecutive cohort of patients undergoing TSA with a nonspherical humeral head and inlay glenoid in the inpatient and outpatient settings by a single surgeon between 2017 and 2022. Age, sex, body mass index, American Society of Anesthesiologists (ASA) score, Charlson Comorbidity Index (CCI), and 90-day complication and readmission rates were compared between inpatient and outpatient groups. Results: One hundred eighteen TSAs in 111 patients were identified. Mean age was 64.9 years (range, 39-90) and 65% of patients were male. Ninety-four (80%) and 24 (20%) patients underwent outpatient and inpatient procedures, respectively. Four complications (3.4%) were recorded: axillary nerve stretch injury, isolated ipsilateral arm deep venous thrombosis (DVT), ipsilateral arm DVT with pulmonary embolism requiring readmission, and gastrointestinal bleed requiring readmission. There were no reoperations or other complications. Outpatients were younger with lower ASA and CCI scores than inpatients; however, there was no difference in complications (1/24 vs. 3/94, P=1.00) or readmissions (1/24 vs. 1/94, P=0.37) between these two groups. Conclusions: TSA with a nonspherical humeral head and inlay glenoid can be performed safely in both inpatient and outpatient settings. Rates of early complications and readmissions were low with no difference according to surgical setting. Level of evidence: IV.

THE EFFECT OF ABUTMENT HEIGHT ON SCREW LOOSENING IN SINGLE IMPLANT-SUPPORTED PROSTHESES AFTER DYNAMIC CYCLIC LOADING

  • Kim Nam-Gun;Kim Yung-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.6
    • /
    • pp.664-670
    • /
    • 2004
  • Statement of problem. One of the common problems of dental implant prosthesis is the loosening of the screw that connects each component, and this problem is more common in single implant-supported prostheses with external connection. Purpose. The purpose of this study was to examine the changes of detorque values of abutment screws with external connection in different abutment heights. Materials and methods. After cyclic loading on three different abutment heights, detorque values were measured. Abutments were retained with titanium abutment screws tightened to 30 Ncm (30.5 kgmm) with digital torque gauge as recommended by the manufacturer. Replacing abutments, implants and titanium abutment screws with new ones at every measurement, initial detorque values were measured six times. In measuring de torque values after cyclic loading, Avana Cemented Abutments of 4.0 mm collar, 7.0 mm height (Osstem Co., Ltd., Seoul, Korea) were used with three different lengths of 5.0, 8.0, 11.0 mm. Shorter abutments were made by milling of 11.0 mm abutment to have the same force-exercised area of 4.5 mm diameter. Sine curve force (20N-320N, 14Hz) was applied, and detorque values were measured after cyclic loading of 2 million times by loading machine. Detorque values of initial and after-loading were measured by digital torque gauge. One-way ANOVA was employed to see if there was any influence from different abutment heights. Results. The results were as follows: 1. The initial detorque value was 27.8$\pm$0.93 kgmm, and the ratio of the initial detorque value to the tightening torque was 0.91(27.8/30.5). 2. Measured detorque values after cyclic loading were declined as the height of the abutment increased, that was, 5.0 mm; 22.3$\pm$0.82 kgmm, 8.0 mm; 21.8$\pm$0.93 kgmm, and 11.0 mm; 21.3$\pm$0.94 kgmm. 3. One-way ANOVA showed no statistically significant differences among these (p>0.05). 4. Noticeable mobility at the implant-abutment interface was not observed in any case after cyclic loading at all.

Evaluation of Tightness of Proximal tooth Contact on Implant Prostheses (임프란트 보철수복물에서의 인접치간 접촉강도의 평가)

  • Kim, Sang-Pil;Jung, J-Hyun;Kang, Dong-Wan;Oh, Sang-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.371-379
    • /
    • 2008
  • The aim of this study was to evaluate the tightness of proximal tooth contact(TPTC) using a novel device at rest state on implant prostheses. Ten healthy young adults with class I normal occlusion consented to participate in the study and twenty patients were restored with a total 20 single-implant crowns in the left maxillary and mandibular second molars for 10 single-implant crowns, respectively. Test area were divided by 4 groups. UM describes the contact between the upper natural left first molar and natural second molar; LM the contact between the lower natural left first molar and natural second molar; IUM the contact between the upper natural left first molar and implant second molar and ILM the contact between the lower natural left first molar and implant second molar. The TPTC was measured at rest state in each area. The mean TPTC of the UM, LM, IUM and ILM was 1.48(${\pm}0.44$) N, 1.78(${\pm}0.40$) N, 1.14(${\pm}0.37$) N and 1.30(${\pm}0.32$) N respectively. These results indicate that the TPTC was less between natural tooth and implant prosthesis than between natural teeth.

The Effect of Hounsfield Unit Value with Conventional Computed Tomography and Intraoperative Distraction on Postoperative Intervertebral Height Reduction in Patients Following Stand-Alone Anterior Cervical Discectomy and Fusion

  • Lee, Jun Seok;Son, Dong Wuk;Lee, Su Hun;Ki, Sung Soon;Lee, Sang Weon;Song, Geun Sung;Woo, Joon Bum;Kim, Young Ha
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.1
    • /
    • pp.96-106
    • /
    • 2022
  • Objective : The most common complication of anterior cervical discectomy and fusion (ACDF) is cage subsidence and maintenance of disc height affects postoperative clinical outcomes. We considered cage subsidence as an inappropriate indicator for evaluating preservation of disc height. Thus, this study aimed to consider patients with complications such as reduced total disc height compared to that before surgery and evaluate the relevance of several factors before ACDF. Methods : We retrospectively reviewed the medical records of 40 patients who underwent stand-alone single-level ACDF using a polyetheretherketone (PEEK) cage at our institution between January 2012 and December 2018. Our study population comprised 19 male and 21 female patients aged 24-70 years. The minimum follow-up period was 1 year. Twenty-seven patients had preoperative bone mineral density (BMD) data on dual-energy X-ray absorptiometry. Clinical parameters included sex, age, body mass index, smoking history, and prior medical history. Radiologic parameters included the C2-7 cobb angle, segmental angle, sagittal vertical axis, disc height, and total intervertebral height (TIH) at the preoperative and postoperative periods. Cage decrement was defined as the reduction in TIH at the 6-month follow-up compared to preoperative TIH. To evaluate the bone quality, Hounsfield unit (HU) value was calculated in the axial and sagittal images of conventional computed tomography. Results : Lumbar BMD values and cervical HU values were significantly correlated (r=0.733, p<0.001). We divided the patients into two groups based on cage decrement, and 47.5% of the total patients were regarded as cage decrement. There were statistically significant differences in the parameters of measuring the HU value of the vertebra and intraoperative distraction between the two groups. Using these identified factors, we performed a receiver operating characteristic (ROC) curve analysis. Based on the ROC curve, the cut-off point was 530 at the HU value of the upper cortical and cancellous vertebrae (p=0.014; area under the curve [AUC], 0.727; sensitivity, 94.7%; specificity, 42.9%) and 22.41 at intraoperative distraction (p=0.017; AUC, 0.722; sensitivity, 85.7%; specificity, 57.9%). Using this value, we converted these parameters into a bifurcated variable and assessed the multinomial regression analysis to evaluate the risk factors for cage decrement in ACDF. Intraoperative distraction and HU value of the upper vertebral body were independent factors of postoperative subsidence. Conclusion : Insufficient intraoperative distraction and low HU value showed a strong relationship with postoperative intervertebral height reduction following single stand-alone PEEK cage ACDF.