• 제목/요약/키워드: Single photon emission tomography (SPECT)

검색결과 138건 처리시간 0.028초

기능적 영상술을 이용한 다약제 내성의 체내 진단 (Functional Imaging of the Multidrug Resistance In Vivo)

  • 이재태
    • 대한핵의학회:학술대회논문집
    • /
    • 대한핵의학회 2001년도 제40차 춘계학술대회 및 연수교육
    • /
    • pp.66-75
    • /
    • 2001
  • Although diverse mechanisms are involved in multidrug resistance for chemotherapeutic drugs, the development of cellular P-glycoprotein(Pgp) and multidrug-resistance associated protein (MRP) are important factors in the chemotherapy failure to cancer. Various detection assays provide information about the presence of drug efflux pumps at the mRNA and protein levels. However these methods do not yield information about dynamic function of Pgp and MRP un vivo. Single photon emission tomography (SPECT) and positron emission tomography (PET) are available for the detection of Pgp and MRP-mediated transport. $^{99m}Tc$-sestaMIBl and other $^{99m}Tc$-radiopharmaceuticals are substrates for Pgp and MRP, and have been used in clinical studies for tumor imaging, and to visualize blockade of Pgp-mediated transport after modulation of Pgp pump. Colchicine, verapamil and daunorubicin labeled with $^{11}C$ have been evaluated for the quantification of Pgp-mediated transport with PET in vivo and reported to be feasible substrates with which to image Pgp function in tumors. Leukotrienes are specific substrates for MRP and N-$[^{11}C]$acetyl-leukotriene E4 provides an opportunity to study MRP function non-invasively in vivo. Results obtained from recent publications are reviewed to confirm the feasibility of using SPECT and PET to study the functionality of MDR transporters in vivo.

  • PDF

두부외상 환자에서 HMPAO-SPECT를 이용한 국소 뇌혈류 변화의 평가 (Spect Assessment of Regional Cerebral Perfusion Abnormality in Head Injury)

  • 이경한;김철희;장하성
    • 대한핵의학회지
    • /
    • 제26권2호
    • /
    • pp.235-243
    • /
    • 1992
  • Patterns of abnormality in regional cerebral perfusion and its relation to clinical severity was evaluated with 32 head injury patients using $^{99m}Tc-HMPAO$ single photon emission tomography (SPECT). The findings were compared with computed tomography (CT) done within 48 hours of each SPECT study. The initial SPECT study was done within 7 days of injury in 16 cases, between 1 week and 2 months in 12, and after over 2 months in 4. Nineteen of the patients underwent followup SPECT and CT after a mean interval of 1 to 2 months. The initial SPECT showed abnormalities in 96% (31/32) of the patients while CT showed abnormal findings in only 81% (26/32). There were a total of 54 supratentorial SPECT lesions in all. Ninity percent (49/54) of these were of regional hypoperfusion, while 5 lesions showed focal hyperperfusion. The lesions were most often localized in the frontal and temporal lobes. Fifty five percent (30/54) were areas not detected as a lesion on CT. Cerebellar diaschisis was observed in 50% (16/32) of the patients. The degree of perfusion abnormality was quantified by the product of differential activity and a size factor. Correlation between the degree of perfusion abnormality and the clinical severity (Glasgow coma scale) failed to show statistical significance (p=0.053). The amount of change in the degree of perfusion abnormality on follow up SPECT was compared to the amount of change in clinical severity. Perfusion abnormality showed a tendancy to improve in most patients, and the degree of improvement showed significant correlation with the amount of clinical improvement (p < 0.01).

  • PDF

High-Performance Compton SPECT Using Both Photoelectric and Compton Scattering Events

  • Lee, Taewoong;Kim, Younghak;Lee, Wonho
    • Journal of the Korean Physical Society
    • /
    • 제73권9호
    • /
    • pp.1393-1398
    • /
    • 2018
  • In conventional single-photon emission computed tomography (SPECT), only the photoelectric events in the detectors are used for image reconstruction. However, if the $^{131}I$ isotope, which emits high-energy radiations (364, 637, and 723 keV), is used in nuclear medicine, both photoelectric and Compton scattering events can be used for image reconstruction. The purpose of our work is to perform simulations for Compton SPECT by using the Geant4 application for tomographic emission (GATE). The performance of Compton SPECT is evaluated and compared with that of conventional SPECT. The Compton SPECT unit has an area of $12cm{\times}12cm$ with four gantry heads. Each head is composed of a 2-cm tungsten collimator and a $40{\times}40$ array of CdZnTe (CZT) crystals with a $3{\times}3mm^2$ area and a 6-mm thickness. Compton SPECT can use not only the photoelectric effect but also the Compton scattering effect for image reconstruction. The correct sequential order of the interactions used for image reconstruction is determined using the angular resolution measurement (ARM) method and the energies deposited in each detector. In all the results of simulations using spherical volume sources of various diameters, the reconstructed images of Compton SPECT show higher signal-to-noise ratios (SNRs) without degradation of the image resolution when compared to those of conventional SPECT because the effective count for image reconstruction is higher. For a Derenzo-like phantom, the reconstructed images for different modalities are compared by visual inspection and by using their projected histograms in the X-direction of the reconstructed images.

뇌의 단일 광자 방출 전산화 단층촬영 영상, 양전자 방출 단층 촬영 영상 그리고 핵자기공명 영상의 융합과 등록에 관한 연구 (A study on image registration and fusion of MRI and SPECT/PET)

  • 주라형;최용;권수일;허수진
    • 한국의학물리학회지:의학물리
    • /
    • 제9권1호
    • /
    • pp.47-53
    • /
    • 1998
  • 방사성 의약품 또는 방사성 동위원소를 이용하여 동적 상태의 변화를 측정하고 핵자기 공명 영상에서 해부학적 기준 정보를 얻어 영상을 융합, 등록하고 같은 대상에서 비슷한 검사를 계속해서 비교하게 되며 해부학적 기준 정보나 다른 검사 기기 종류에서 반복되는 검사의 비교를 위해 영상 합성 연구가 유효하며 기능적 특성 때문에 단일 광자 방출 전산화 단층 촬영과 양전자 방출 단층 촬영은 해부학적 기준 정보가 필요하게 되고 같은 대상에서 이러한 해부학적 기준 정보를 얻고 기능적인 이상과 상관관계를 찾아내고 반복되는 진단에 대한 비교를 위해서 영상등록과 융합을 시행하였다. 해부학적 구조가 같은 특성을 갖는 여러 영상 시스템들을 이용하여 해부학적기준과 동적 정보를 함께 얻고 등록하기 위해 짝을 이루는 점올 이용하여 2 가지 영상 데이터에서 4 점 쌍 이상을 선택하여 등록하였다. 기준 영상과 짝을 이루는 점과 대응한 영상은 다른 색을 선택하여 영상을 구분하였으며 핵자기 공명영상을 기준영상으로 하고 단일 광자 방출 컴퓨터 단층 촬영 영상, 양전자 방출 전산화 단층 촬영 영상을 기준영상에 1:1 대응하여 영상을 등록하기 위해서 변환한다. 핵자기 공명 영상이 기준 영상으로 사용되지만 인터폴레이션 에러는 주어진 영상의 공간 주파수에 따라 달라지므로 낮은 해상도를 갖는 양전자 방출 전산화 단층 촬영 영상과 단일 광자 방출 컴퓨터 단층 촬영 영상의 인터폴레이션 에러는 적다. 따라서 방사성 동위원소를 이용하여 질병의 진단 및 질환의 병태 생리 생화학적 연구를 통한 신체의 동역학적 상태의 변화를 측정할 수 있는 이런 정량적이고 기능적인 정보를 해부학적 기준 정보를 주는 핵자기 공명 영상이나 컴퓨터 단층 촬영에서 반복 시행하여 검사와 진단에 용이하게 이용하고, 비교를 위해서 영상을 등록하고 융합하여 진단에 보다 좋은 결과를 얻을 수 있도록 하였다.

  • PDF

Post-Coronary Artery Bypass Grafting Myocardial Ischemia Caused by an Overgrown Left Internal Thoracic Artery Side Branch

  • Kim, Eung Re;Oh, Se Jin;Kang, Hyun-Jae;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • 제47권5호
    • /
    • pp.465-467
    • /
    • 2014
  • We present a patient who developed recurrent angina after coronary artery bypass grafting (CABG). Myocardial single-photon emission computed tomography (SPECT) demonstrated deterioration in the myocardial perfusion, and coronary angiography revealed an overgrown side branch of the grafted left internal thoracic artery (ITA); otherwise, there were no significant changes compared with previous imaging studies obtained after the CABG. After percutaneous embolization of the grafted left ITA side branch, the angina was resolved and myocardial SPECT showed improved perfusion.

Spect-guidance to Reduce Radioactive Dose to Functioning Lung for Stage III Non-small Cell Lung Cancer

  • Wang, Zhong-Tang;Wei, Li-Li;Ding, Xiu-Ping;Sun, Ming-Ping;Sun, Hong-Fu;Li, Bao-Sheng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권2호
    • /
    • pp.1061-1065
    • /
    • 2013
  • Objective: To investigate the treatment effect of additional information obtained by single photon emission computed tomography (SPECT) lung perfusion imaging (LPI) in the radiotherapy planning process for patients with stage III non-small cell lung cancer (NSCLC). Methods: 39 patients with stage III NSCLC were enrolled. Gross tumor volume (GTV) was outlined by SPECT/CT images, SPECT-LPIs being used to define functional lung (FL) and non-functional lung (NFL) regions. Two sets of IMRT plans were designed to deliver 64Gy to PTV. One was a regular IMRT plan using CT images only (Plan 1), and the other was a corresponding IMRT plan using co-registered images (Plan 2). $FL_{Vx}$ (the % volume of functional lung receiving ${\geq}$x Gy) and $WL_{Vx}$ (% volume of whole lung to receive ${\geq}$x Gy) were compared by paired Student's t test. Kendalls correlation was used to analyze the factor (s) related with the FLV20 decrease. Results: Compared with plan 1, both $WL_{Vx}$ and $FL_{Vx}$ were decreased in plan 2. $WL_{V10}$, $WL_{V15}$, $WL_{V20}$, $WL_{V25}$, $WL_{V30}$ and $WL_{V35}$ decreased 9.7%, 13.8%, 17.2%, 12.9%, 9.8% and 9.8%, and $FL_{V10}$, $FL_{V15}$, $FL_{V20}$, $FL_{V25}$, $FL_{V30}$ and $FL_{V35}$ decreased 10.8%, 14.6%, 17.3%, 14.5%, 14.5% and 10.5%. $FL_{Vx}$ decreased significantly compared with $WL_{Vx}$. There were significant differences in $WL_{V10}$, $WL_{V15}$, $WL_{V20}$, $WL_{V25}$, $WL_{V3}$ and $FL_{V10}$, $FL_{V15}$, $FL_{V20}$, $FL_{V25}$, $FL_{V30}$ between plan 1 and plan 2 (P=0.002, 0.000, 0.000, 0.005, 0.027 and 0.002, 0.000, 0.000, 0.006, 0.010). According to Kendall correlation analysis, NFL had a negative relation with the percentage FLV20 decrease (r=-0.559, P<0.01), while the distance of PTV and NFL center had a significantly positive relation with the percentage of FLV20 decrease (r=0.768, P<0.01). Conclusion: Routine use of SPECT-LPI for patients undergoing radiotherapy planning for stage III NSCLC appears warranted.

SPECT/CT를 이용한 증후성 족부 부골의 진단 (Diagnosing Symptomatic Accessory Tarsal Bones Using SPECT/CT)

  • 김려섭;강준순;김영태;김범수
    • 대한족부족관절학회지
    • /
    • 제15권4호
    • /
    • pp.212-216
    • /
    • 2011
  • Purpose: This study was designed to analyze the usefulness of Single Photon Emission Computed Tomography/Computed Tomography (SPECT/CT) in diagnosing symptomatic accessory tarsal bones. Materials and Methods: Twenty four feet (16 patients) with symptomatic accessory navicular and/or os trigonum, who agreed to take SPECT/CT, were included in this study. Fifteen feet had accessory navicular, five had os trigonum, and four had both. According to the uptake in the SPECT/CT, 11 feet were classified into high and 13 into low uptake groups. The low uptake group was treated non-operatively, while the high uptake group received operations when initial conservative management failed. A modified Kidner procedure was performed for accessory navicular and arthroscopic excision was done for os trigonum. After a mean follow-up of 6.8 (range, 3~13) months, the American Orthopaedic Foot and Ankle Society (AOFAS) score and the Visual Analogue Scale (VAS) for pain were compared. Results: Patients in the high uptake group had a higher initial mean VAS score ($7.0{\pm}0.8$ vs $2.2{\pm}0.9$, p<0.05) and a lower initial mean AOFAS score ($45.9{\pm}9.2$ vs $83.9{\pm}4.2$, p<0.05) compared to the low uptake group. All patients in the low uptake group improved after non-operative treatment. Seven patients underwent operations and had a decreased VAS ($1.6{\pm}0.5$) and an increased AOFAS score ($88.3{\pm}1.8$) at the last follow-up. Four patients in the high uptake group demonstrated erratic symptoms. Conclusion: SPECT/CT can be a useful diagnostic tool and helpful in designing treatment plans for symptomatic accessory navicular and os trigonum.

Daily adaptive proton therapy: Feasibility study of detection of tumor variations based on tomographic imaging of prompt gamma emission from proton-boron fusion reaction

  • Choi, Min-Geon;Law, Martin;Djeng, Shin-Kien;Kim, Moo-Sub;Shin, Han-Back;Choe, Bo-Young;Yoon, Do-Kun;Suh, Tae Suk
    • Nuclear Engineering and Technology
    • /
    • 제54권8호
    • /
    • pp.3006-3016
    • /
    • 2022
  • In this study, the images of specific prompt gamma (PG)-rays of 719 keV emitted from proton-boron reactions were analyzed using single-photon emission computed tomography (SPECT). Quantitative evaluation of the images verified the detection of anatomical changes in tumors, one of the important factors in daily adaptive proton therapy (DAPT) and verified the possibility of application of the PG-ray images to DAPT. Six scenarios were considered based on various sizes and locations compared to the reference virtual tumor to observe the anatomical alterations in the virtual tumor. Subsequently, PG-rays SPECT images were acquired using the modified ordered subset expectation-maximization algorithm, and these were evaluated using quantitative analysis methods. The results confirmed that the pixel range and location of the highest value of the normalized pixel in the PG-rays SPECT image profile changed according to the size and location of the virtual tumor. Moreover, the alterations in the virtual tumor size and location in the PG-rays SPECT images were similar to the true size and location alterations set in the phantom. Based on the above results, the tumor anatomical alterations in DAPT could be adequately detected and verified through SPECT imaging using the 719 keV PG-rays acquired during treatment.

99mTc-3PRGD2 SPECT/CT Imaging for Diagnosing Lymph Node Metastasis of Primary Malignant Lung Tumors

  • Liming Xiao;Shupeng Yu;Weina Xu;Yishan Sun;Jun Xin
    • Korean Journal of Radiology
    • /
    • 제24권11호
    • /
    • pp.1142-1150
    • /
    • 2023
  • Objective: To evaluate 99mtechnetium-three polyethylene glycol spacers-arginine-glycine-aspartic acid (99mTc-3PRGD2) single-photon emission computed tomography (SPECT)/computed tomography (CT) imaging for diagnosing lymph node metastasis of primary malignant lung neoplasms. Materials and Methods: We prospectively enrolled 26 patients with primary malignant lung tumors who underwent 99mTc-3PRGD2 SPECT/CT and 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/CT imaging. Both imaging methods were analyzed in qualitative (visual dichotomous and 5-point grades for lymph nodes and lung tumors, respectively) and semiquantitative (maximum tissue-to-background radioactive count) manners for the lymph nodes and lung tumors. The performance of the differentiation of lymph nodes with and without metastasis was determined at the per-lymph node station and per-patient levels using histopathological results as the reference standard. Results: Total 42 stations had metastatic lymph nodes and 136 stations had benign lymph nodes. The differences between metastatic and benign lymph nodes in the visual qualitative and semiquantitative analyses of 99mTc-3PRGD2 SPECT/CT and 18F-FDG PET/CT were statistically significant (all P < 0.001). The area under the receiver operating characteristic curve (AUC) in the semi-quantitative analysis of 99mTc-3PRGD2 SPECT/CT was 0.908 (95% confidence interval [CI], 0.851-0.966), and the sensitivity, specificity, positive predictive value, and negative predictive value were 0.86 (36/42), 0.88 (120/136), 0.69 (36/52), and 0.95 (120/126), respectively. Among the 26 patients (including two patients each with two lung tumors), 15 had pathologically confirmed lymph node metastasis. The difference between primary lung lesions in patients with and without lymph node metastasis was statistically significant only in the semi-quantitative analysis of 99mTc-3PRGD2 SPECT/CT (P = 0.007), with an AUC of 0.807 (95% CI, 0.641-0.974). Conclusion: 99mTc-3PRGD2 SPECT/CT imaging may notably perform in the direct diagnosis of lymph node metastasis of primary malignant lung tumors and indirectly predict the presence of lymph node metastasis through uptake in the primary lesions.

PubMed와 대한침구학회지(大韓針灸學會誌) 논문(論文) 검색(檢索)을 통(通)한 침요법(鍼療法)과 뇌(腦)와의 관계(關係)에 대한 연구동향(硏究動向) 고찰(考察) (The acupuncture mechanism related brain in Medline and the journal of Korean acupuncture & moxibustion)

  • 김후동;고형균;김창환
    • Journal of Acupuncture Research
    • /
    • 제18권4호
    • /
    • pp.188-200
    • /
    • 2001
  • Background and Objetive : Acupuncture is a valuable method of oriental medicine with broad application in many disease. It is based on the experiences of traditional oriental medicine as well as on experimentally proven biological (biochemical and neurophysiological) effects. Acupuncture theory has been explained by the meridian system that is thought to be linked with particular organs. However, in western medicine it is held that many disorders are either controlled or affected by the brain. Material and Method : In order to review the studies concerned with the mechanism related brain, we have referred to the Pubmed site and the Journal of Korean acupuncture and moxibustion Result and Conculsion : Among the 12 studies in the Journal of Korean acupuncture and moxibustion, 8 papers related neurotransmitters were done by experimental study, 4 papers related brain mapping were done by clinical study. Among the 8 studies related brain mapping in the Pubmed site, 6 clinical studies using functional magnetic resonance imaging(fMRI) were done and I clinical study using single-photon emission computed tomography(SPECT) was done, I paper was review article. By the above result, it would be needed further research on the acupuncture mechanism related brain using SPECT, fMRI, positron emission tomography(PET) etc.

  • PDF