• Title/Summary/Keyword: Single photon emission computed tomography

Search Result 155, Processing Time 0.024 seconds

The Preoperative Evaluation of the Carotid Artery in Head and Neck Surgery (두경부수술에서 경동맥 희생과 사전검사)

  • Kwon Tack-Kyun;Sung Myung-Whun;Kim Kwang-Hyun;Kim Jeong-Jun;Lee Chul-Hee;Min Yang-Gi
    • Korean Journal of Head & Neck Oncology
    • /
    • v.14 no.2
    • /
    • pp.175-181
    • /
    • 1998
  • Objectives: The authors tried to analyze the results of carotid artery sacrifice with or without preoperative carotid evaluation. Materials and Methods: Thirteen patients undergone carotid sacrifice were evaluated. Carotid balloon occlusion test (BOT) and single-photon emission computed tomography (SPECT) with technetium-99m-labeled hexamethylpropyleneamineoxime ($^{99m}Tc-HMPAO$) were used for preoperative carotid evaluation. Results: The causes of carotid artery sacrifice consisted of the neck mass involving the carotid artery, spontaneous aneurysmal rupture, and traumatic pseudoaneurysm. Five patient had postoperative neurologic complications and two of them had permanent neurologic deficits. Conclusion: The authors stress that the preoperative evaluation in carotid artery sacrifice is imperable, and the BOT with SPECT can be used in selecting the method of treatment. But since these tests cannot predict the postoperative outcome perfectly, careful perioperative care of the patients should be exercised regardless of the results of the preoperative evaluation.

  • PDF

Cross Talk Experiment with Two-element CdTe Detector and Collimator for BNCT-SPECT

  • Manabe, Masanobu;Ohya, Ryosuke;Saraue, Nobuhide;Sato, Fuminobu;Murata, Isao
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.328-332
    • /
    • 2016
  • Background: Boron Neutron Capture Therapy (BNCT) is a new radiation therapy. In BNCT, there exists some very critical problems that should be solved. One of the severest problems is that the treatment effect cannot be known during BNCT in real time. We are now developing a SPECT (single photon emission computed tomography) system (BNCT-SPECT), with a cadmium telluride (CdTe) semiconductor detector. BNCT-SPECT can obtain the BNCT treatment effect by measuring 478 keV gamma-rays emitted from the excited state of $^7Li$ nucleus created by $^{10}B(n,{\alpha})$ $^7Li$ reaction. In the previous studies, we investigated the feasibility of the BNCT-SPECT system. As a result, the S/N ratio did not meet the criterion of S/N > 1 because deterioration of the S/N ratio occurred caused by the influence of Compton scattering especially due to capture gamma-rays of hydrogen. Materials and Methods: We thus produced an arrayed detector with two CdTe crystals to test cross talk phenomenon and to examine an anti-coincidence detection possibility. For more precise analysis for the anti-coincidence detection, we designed and made a collimator having a similar performance to the real BNCT-SPECT. Results and Discussion: We carried out experiments with the collimator to examine the effect of cross talk of scattering gamma-rays between CdTe elements more practically. As a result of measurement the coincidence events were successfully extracted. Conclusion: We are now planning to carry out evaluation of coincidence rate from the measurement and comparison of it with the numerical calculations.

Biodistribution of 99mTc Tricarbonyl Glycine Oligomers

  • Jang, Beom-Su;Lee, Joo-Sang;Rho, Jong Kook;Park, Sang Hyun
    • Toxicological Research
    • /
    • v.28 no.4
    • /
    • pp.235-240
    • /
    • 2012
  • $^{99m}Tc$ tricarbonyl glycine monomers, trimers, and pentamers were synthesized and evaluated for their radiolabeling and in vivo distribution characteristics. We synthesized a $^{99m}Tc$-tricarbonyl precursor with a low oxidation state (I). $^{99m}Tc(CO)_3(H_2O)_3^+$ was then made to react with monomeric and oligomeric glycine for the development of bifunctional chelating sequences for biomolecules. Labeling yields of $^{99m}Tc$-tricarbonyl glycine monomers and oligomers were checked by high-performance liquid chromatography. The labeling yields of $^{99m}Tc$-tricarbonyl glycine and glycine oligomers were more than 95%. We evaluated the characteristics of $^{99m}Tc$-tricarbonyl glycine oligomers by carrying out a lipophilicity test and an imaging study. The octanol-water partition coefficient of $^{99m}Tc$ tricarbonyl glycine oligomers indicated hydrophilic properties. Single-photon emission computed tomography imaging of $^{99m}Tc$-tricarbonyl glycine oligomers showed rapid renal excretion through the kidneys with a low uptake in the liver, especially of $^{99m}Tc$ tricarbonyl triglycine. Furthermore, we verified that the addition of triglycine to prototype biomolecules (AGRGDS and RRPYIL) results in the improvement of radiolabeling yield. From these results, we conclude that triglycine has good characteristics for use as a bifunctional chelating sequence for a $^{99m}Tc$-tricarbonyl-based biomolecular imaging probe.

Encephalo-duro-arterio-synangiosis(EDAS) using Occipital Artery in Children with Moyamoya Disease

  • Choi, In-Jae;Hong, Seok-Ho;Cho, Byung-Kyu;Wang, Kyu-Chang;Kim, Seung-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.6
    • /
    • pp.413-418
    • /
    • 2005
  • Objective : Although an encephaloduroarteriosynangiosis procedure using the superficial temporal artery [STA-EDAS] is an effective indirect bypass method in children with moyamoya disease[MMD], there is still a need for an additional bypass operation that can cover the area of the posterior circulation. The goal of this study is to evaluate the efficacy of the EDAS procedure using the occipital arteries [OA-EDAS]. Methods : From August 2003 to April 2004, We performed OA-EDAS in sixteen patients with MMD who have a circulatory insufficiency in the territory of the posterior cerebral artery[PCA]. The medical records were reviewed retrospectively. The surgical outcomes, including the changes in neurological status and imaging studies, with the degree of neovascularization on the cerebral angiogram, and the hemodynamic changes on single-photon emission computed tomography[SPECT], were analyzed. Results : These 16 children consisted of 5 boys and 11 girls aged 2 to 9 years. The clinical outcome of their PCA symptoms, such as visual transient ischemic attacks[TIAs] or visual field defect, was favorable in 14 patients of 16. Nine patients of 11 who underwent follow up magnetic resonance imaging[MRI] showed favorable MRI changes. On angiogram most of the patients exhibited good or fair revascularization of the PCA territory [7 of 8]. The hemodynamic changes on SPECT in the PCA territory after surgery showed improved vascular reserve in 13 of the 16 territories. Conclusion : OA-EDAS is a safe and efficacious revascularization procedure in patients with MMD who have compromised cerebral perfusion in PCA territory, or with visual TIAs.

Effect of the Number of Detectors on Performance of Industrial SPECT (산업용 SPECT의 검출기 개수가 영상 해상도에 미치는 영향 평가)

  • Park, Jang Guen;Kim, Chan Hyeong;Kim, Jong Bum;Moon, Jinho;Jung, Sung-Hee
    • Journal of Radiation Industry
    • /
    • v.5 no.4
    • /
    • pp.325-330
    • /
    • 2011
  • To predict the details of flow in industrial process unit, single photon emission computed tomography (SPECT) is a promising technique. Recently, industrial SPECT based on medical system has developed by researchers of the Korea Atomic Energy Research Institute (KAERI) and Hanyang University. In the present study, to confirm the effect of the number of detectors on image quality, and determine the optimal number of detectors in industrial SPECT, industrial SPECT system with various geometries were evaluated by the Monte Carlo simulation. CsI(Tl) detectors ($12mm{\times}12mm{\times}20mm$) with collimators (the geometric resolution of collimator $R_g$ was 4 cm at the center of the 30 cm diameter cylindrical vessel object) were modeled in a hexagonal array, and the point sources of $^{99m}Tc$, $^{68}Ga$, and $^{137}Cs$ were simulated at the center of the cylindrical vessel object using the MCNPX code. Then, the reconstruction images of each geometry were reconstructed using the expectation maximization (EM) algorithm. In this study, the reciprocity theorem was used to improve computation time required for system matrix of the EM algorithm. The result shows that the resolution of the reconstructed image was significantly improved by increasing the number of detectors in industrial SPECT system and more than 60 detectors will be required for the resolution of the reconstructed image.

A Study on Comparison of Cardiac Ejection Fraction Values Measured in Myocardium SPECT and Cine MRI

  • Han, Jung-Seok;Dong, Kyung-Rae;Park, Yong-Soon;Chung, Woon-Kwan;Cho, Jae-Hwan;Cho, Young-Kuk
    • Journal of Magnetics
    • /
    • v.17 no.3
    • /
    • pp.229-232
    • /
    • 2012
  • This study examined the correlation between MR cine and myocardium Single-photon emission computed tomography (SPECT) by comparing the measured cardiac ejection fractions. The usefulness of cardiac MRI was also evaluated. Ten patients (8 men, 2 women and average age of 58.6 years), who underwent a myocardium SPECT scan and cardiac cine MRI scan among patients who visited the hospital for the chief complaint of cardiac disorder from June 1, 2010 to February 10, 2011, were enrolled in this study. The cardiac ejection fraction was calculated from the images obtained in both scans. The data was used to examine the correlation. The regression equation the cardiac ejection fraction values of the 10 patients obtained in myocardium SPECT and MRI cine was Y = 1.12X-8.91 ($R^2$ = 0.78, significance of F = 0.001639, and confidence level of 95%). The results were significant when the cardiac ejection fraction obtained from MRI cine was compared with that obtained from myocardium SPECT. Overall, a cardiac examination using MRI enables an investigation of not only the ejection fraction but also the ED and ES volumes, stroke volume, wall thickness, and wall thickening in a higher spatial resolution despite the examination being conducted once. This examination is believed to be very useful for diagnosing patients with cardiac disease.

A Study of Conservative Treatment for Patients with Osteoarthritis of the TMJ (측두하악골관절염 환자의 보존적 치료에 관한 연구)

  • Son, Dae-Eun;Ok, Seung-Joon;Ko, Myung-Yun;Ahn, Yong-Woo
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.2
    • /
    • pp.227-239
    • /
    • 2007
  • To evaluate the treatment outcome after conservative treatment in patients with osteoarthritis of the TMJ(OA), the subjects were chosen among the patients who presented to the Department of Oral Medicine of Pusan National University Hospital, diagnosed as osteoarthritis of the TMJ, and treated with conservative methods from 1994 to 2006. 101 patients with diagnosis of osteoarthritis of the TMJ were selected as the experimental group and 74 patients with diagnosis of masticatory muscle disorders(MMD) were selected as the control group. Subjective symptoms and clinical findings were investigated to evaluate and compare the subject's status at the first and the last visit. The results were as follows : 1. In the OA group, satisfactory treatment outcome was obtained with conservative methods. But, at the last visit, the symptoms of the OA group were not improved enough compared with those of the MMD group. 2. In the OA group, radiographic findings of panorama view and transcranial projection were positive by about 60 percent. But, computed tomography and single photon emission computed tomography were positive by more than 90 percent. 3. At the last visit of the OA group, the joint noise was reduced significantly. 4. In the majority of the OA group, satisfactory treatment outcome was obtained with conservative methods such as medication, physical therapy, and occlusal stabilization appliance. In the majority of the MMD group, satisfactory outcome was obtained with medication and physical therapy. 5. It took the OA group from 6 months to 2 years to be cured well while the MMD group within 6 months.6. The OA group needed more than 10 times' treatment for satisfactory outcome while the MMD group needed less than 10 times' treatment.

Usefulness of Xact-bone for the Resolution Advancement of Gamma Camera Image (감마카메라 영상에서 분해능 향상을 위한 Xact-bone의 유용성 평가)

  • Kim, Jong-Pil;Yoon, Seok-Hwan;Lim, Jung-Jin;Woo, Jae-Ryong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.30-35
    • /
    • 2011
  • Purpose: The Boramae Hospital are currently using Wide beam reconstruction (WBR: UltraSPECT, Israel) to improve the resolution. The Xact-bone belongs to the WBR. It has been reported that Xact-bone helps us to improve image resolution and contrast. This study will be evaluated clinical usefulness of Xact-bone method. Materials and Methods: The usefulness evaluation of Xact-bone method was analyzed in resolution test and contrast ratio. The resolution test in Planar image were obtained from Full width at half maximum (FWHM) by using capillary tube. And the contrast ratio was obtained from Bone and Soft tissue (B/S) ratio values that were acquired from bone scan study of 50 patients before and after using the Xact-bone method. We prepared the Triple Line Source Phantom, NEMA IEC Body Phantom and Standard Jaszczak Phantom to acquire the FWHM and Contrast Ratio values of Single photon emission computed tomography (SPECT) image. Subsequently we compared among the Filtered backprojection (FBP), Orderd subset expectation maximization (OSEM) and Xact-Bone image. Results: The results of the planar Xact-bone data improved resolution about 20% by using capillary tube. In addition it was improved B/S ratio about 15%. When using Triple Line Source Phantom, SPECT Xact-bone data improved resolution for both FBP, OSEM methods about 20% and 10%, respectively. Contrast ratio in each spheres has also been increased for both methods that using NEMA IEC body Phantom and Standard Jaszczak Phantom. Conclusion: When we were using Xact-bone method, we could see to improve the resolution and Contrast ratio as compared to do not use the Xact-bone method. Accordingly, by using WBR's Xact-bone method is expected to improve the image quality. However, when introducing new software, it is needed to match the characteristics of the hospital protocol and clinical application.

  • PDF

Comparison of Attenuation Correction Methods for Brain SPECT Ima (Brain SPECT 영상의 Attenuation Correction 방법들에 대한 비교)

  • Jo, Jin U;Kim, Chang Ho;Na, Soo Kyung;Lee, Gui Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.120-125
    • /
    • 2012
  • Purpose : The purpose of this study was to compare count between Chang's method and CT-based attenuation correction (AC-CT) among the attenuation correction (AC) methods for non-attenuation correction (AC-non) images of Brain SPECT (Single Photon Emission Computed Tomography). Materials and Methods : We injected $^{99m}Tc$ 37Mbq in a Hoffman 3D phantom filled with distilled water in the phantom study, and injected intravenously $^{99m}Tc$-HMPAO 740Mbq in a normal volunteer in the patient study, and then obtained Brain SPECT images with Symbia T6 of Siemens and conducted quantitative brain analysis. Transverse images to which each method was applied were rebuilt at the same position, and 6 regions of interest (ROI) were drawn on each of Slice No. 10, 20 and 30 and then the counts of AC-non, AC-CT and Chang's method were compared. Results : The mean counts of AC-non, AC-CT and Chang's method were $4606.8{\pm}511.3$, $16794.6{\pm}2429.4$, and $8752.6{\pm}896.5$, respectively, in the phantom study and $5460.8{\pm}519.6$, $15320{\pm}1171.6$ and $12795{\pm}1422.1$, respectively, in the patient study. In the phantom study, the ratio of AC-CT to AC-non was 3.70 and the ratio of Chang's method to AC-non was 1.92, and in the patient study, they were 2.85 and 2.38, respectively. Conclusion : From this study, we found that AC-CT makes higher AC than Chang's method. In addition, when Chang's method was used, AC in the patient study was higher than that in the phantom study. These results need to be considered also in other examinations.

  • PDF

Effect of ST 36-ST 41 Electro-acupuncture on Regional Cerebral Blood Flow in Normal Volunteers Evaluated by $^{99m}Tc$-ECD SPECT (족삼리-해계 전침치료가 정상인의 국소 뇌혈류에 미치는 영향 -Brain SPECT와 SPM을 이용하여-)

  • Moon, Sang-Kwan;Min, In-Kyu;Park, Sung-Uk;Jung, Woo-Sang;Park, Jung-Mee;Ko, Chang-Nam;Cho, Ki-Ho;Bae, Hyung-Sup;Kim, Young-Suk;Kim, Deok-Yoon
    • The Journal of Korean Medicine
    • /
    • v.31 no.1
    • /
    • pp.130-137
    • /
    • 2010
  • Objectives: So far it has been reported that acupuncture increases cerebral blood supply and stimulates the functional activity of brain nerve cells. Previous studies have demonstrated that frequently used electro-acupuncture (EA) therapies for stroke increased regional cerebral blood flow (rCBF) in normal volunteers. Though ST 36-ST 41 EA is another prevailing therapy for stroke, there had been no report about its effect on rCBF. This study was to evaluate the effect of ST 36-ST 41 EA on rCBF in normal volunteers using single photon emission computed tomography (SPECT) and statistical parametric mapping (SPM). Methods: In the resting state, $^{99m}Tc$-ECD brain SPECT scans were performed on 10 normal volunteers (5 males, 5 female, mean age $23.6{\pm}0.5$ years). On the other study day, 7 days after the resting examination, 15 minutesEA were applied at ST 36 and ST 41 on the right side of the subjects. Immediately after ST36-ST41 EA, the second SPECT images were obtained in the same manner as the resting state. Significant increases and decreases of rCBF after EA were estimated by comparing their SPECT images with those of the resting state using paired t statistics at every voxel, which were analyzed by SPM with a threshold of p = 0.01, uncorrected (extent threshold: k=100 voxels). Results: EA applied at the right ST36-ST41 significantly increased rCBF in the right inferior parietal lobule (Brodmann area [BA] 40), right retrosubicular area (BA 48), left inferior parietal lobule (BA 40), left middle temporal gyrus (BA 21), left fusiform gyrus (BA 37), left inferior parietal lobule (BA 39), left inferior temporal gyrus (BA 20), and left somatosensory association cortex (BA 7). However, right ST36-ST41 EA significantly decreased rCBF in the right parahippocampal gyrus (BA 35), right cerebellum, left frontopolar area (BA 10), left orbitofrontal area (BA 11), left dorsolateral prefrontal cortex (BA 9), and left dorsal anterior cingulate cortex (BA 32). Conclusions: These results demonstrate that rightST36-ST41 EA increased rCBF prominently in both inferior parietal lobule (BA 40) and right retrosubicular area (BA 48), which suggest that there be correlation between specific EA and corresponding rCBF.