• Title/Summary/Keyword: Single phase SCR rectifier

Search Result 5, Processing Time 0.023 seconds

A Study on the SCR Frequency Converter With a Rotating Distributor (회전접촉자를 사용한 SCR 주파수 변환기에 관한 연구)

  • Chung Yon Tack
    • 전기의세계
    • /
    • v.24 no.1
    • /
    • pp.43-53
    • /
    • 1975
  • This paper describes a converter, which combines SCR bridge type rectifier circuit with a rotating distributor. This type of converter produces an adjustable low frequency output of three phase or single phase, from three phase or single phase power source. Output-waveforms of this converter are multi-pulse in three phase output, and square wave in single phase output. Problems about the operation of static switches, a commutation and output-waveforms are investigated, and experimental results verify that frequency can be adjusted satisfactorily from zero to 20 (Hz) and the expected output-waveforms are obtained without sparking on the distributor under various loading conditions. This converter can be utilized to low speed control of A.C. motors, and other lowfrequency loads.

  • PDF

Case Study of Second Harmonic Generation under Nonlinear Load and Second Harmonic Elimination Method Based on Impedance Variation Scheme (비선형 부하 이차 고조파 발생 실증사례 분석 및 임피던스 변동 기법을 통한 이차 고조파 저감 기법)

  • Bang, Heegyun;Kim, Sikyung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.5
    • /
    • pp.604-611
    • /
    • 2013
  • This paper presents an second harmonic elimination method based on the impedance variation scheme. Through the power quality analysis from the nonlinear loads connected on the power system, the second harmonic problems have been analyzed with a case study analysis and the experiments. In the paper, the second Harmonic generation was simulated with a single phase SCR rectifier and the analytical model is proposed for the second harmonic generation. A novel impedance variation scheme is proposed and analyzed to eliminate the second harmonic. The experiment has been performed on the 60(MVA) industry manufacturing plant. The experimental result demonstrates the proposed impedance variation scheme successfully operate on the 60(MVA) industry manufacturing plant.

Module-Type Switching Rectifier for Cathodic Protection of Underground and Maritime Metallic Constructions (지하매설 및 해양 금속구조물 음극방식용 모듈 타입 스위칭 정류기)

  • 문상호;김보경;김인동;노의철;권영원;정성우;임헌호
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.6
    • /
    • pp.570-578
    • /
    • 2002
  • Cathodic protection is widely used to prevent corrosion of steel materials buried in the underground and sea. As a rectifier for cathodic protection, the conventional phase-controlled rectifiers have been used so far in spite of such shortcomings as large volume, heavy weight and floor power factor. In order to overcome such disadvantages, this paper proposes a new module-type switching rectifier for cathodic protection, which is composed of two parts, namely, AC/DC converter and module- type DC/DC converter. The AC/DC converter is a single-phase IGBT PWM rectifier, thus resulting in almost unity power factor and controlled DC output voltage. The module-type DC/DC converter operates under ZVS/ZCS switching condition to permit high frequency switching operation. It enables to use high-frequency transformer for electrical isolation, thus reducing volume and weight of overall system and improving system efficiency. It should be anticipated that the proposed rectifier techniques apply to the similar technical areas.

Effects of Contrast Improvement on High Voltage Rectification Type of X-ray Diagnostic Apparatus (X선 진단장치의 고압정류방식이 대조도 향상에 미치는 영향)

  • Lee, Hoo-Min;Yoon, Joon;Kim, Hyun-Ju
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.187-193
    • /
    • 2014
  • The purpose of this study was to analyze the effect on the selectivity on of high-voltage rectification device that measured the performance of the grid, and the contrast improvement ability (K factor) by measuring the scattered radiation content of the transmitted X-rays. The scattered radiation generated when the X-ray flux comes from the diagnostic X-ray generator that passes through an object. Targeting four different rectifications of X-ray generators, the mean value of the tube voltage and the tube current was measured in order to maximize the accuracy of the generating power dose within the same exposure condition. Using fluorescence meter, the content of the scattered rays that are transmitted through the acrylic was measured depending on the grid usage. When grid is not used, the content of the scattered rays was the lowest (34.158%) with the single-phase rectifier, was increased with the inverter rectifier (37.043%) and the three-phase 24-peak rectification method (37.447%). The difference of the scattered radiation content of each device was significant from the lowest 0.404% to the highest 3.289% while using 8:1 grid, the content of the scattered ray was the lowest with the single content of the scattered ray was the lowest with the single-phase rectifier (18.258%), was increased with the rectifier (25.502%) and the 24-peaks rectification (24.217%). Furthermore, there was difference up to content 7.244% to the lowest content 1.285% within three-phase 24-peaks rectification, inverter rectifications, and single-phase rectifier depending on the selectivity of the grid. Drawn from the statistical analysis, there was a similar relationship between the contrast improvement factor and the K factor. As a result, the grid selectivity and the contrast were increased within the single-phase rectifier rather than the constant voltage rectifier.

The Improvement of Transient State Characteristics with Voltage Type PWM Conbverter Control (전압형 PWM 컨버터 제어에의한 과도상태의 특성 개선)

  • 이상일;이진섭;백형래
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.3
    • /
    • pp.268-274
    • /
    • 1999
  • The problem of power factor and hmmonics are occurred in convelter system which used to SCRs and diodes as p power semiconductor devices. IGBT power device with selh:ommutation type was solved that problem. maintain the l input line current with sinusoidal wave CUlTent of input power source voltage. It was estimated that improvement of t transient state characteristics with feedfolward compensator added in the diode rectifier with single phase voltage type i inverter was used to simulation load. As a results it was verified that the transient state characteristics with voltage t type PWM convelter control was improved.

  • PDF