• 제목/요약/키워드: Single phase

검색결과 5,340건 처리시간 0.029초

CUPID 코드의 유체 물성치 변화를 고려한 자연대류 해석 (NATURAL CIRCULATION ANALYSIS CONSIDERING VARIABLE FLUID PROPERTIES WITH THE CUPID CODE)

  • 이승준;박익규;윤한영;김정우
    • 한국전산유체공학회지
    • /
    • 제20권4호
    • /
    • pp.14-20
    • /
    • 2015
  • Without electirc power to cool down the hot reactor core, passive systems utilizing natural circulation are becoming a big specialty of recent neculear systems after the severe accident in Fukusima. When we consider the natural circulation in a pool, thermal mixing phenomena may start from single phase circulation and can continue to two phase condition. Since the CUPID code, which has been developed for two-phase flow analysis, can deal with the phase transition phenomena, the CUPID would be pertinent to natural convection problems in single- and two-phase conditions. Thus, the CUPID should be validated against single- and two-phase natural circulation phenomena. For the first step of the validation process, this study is focused on the validation of single-phase natural circulation. Moreover, the CUPID code solves the fluid properties by the relationship to pressure and temperature from the steam table considering non-condensable gas effects, so that the effects from variable properties are included. Simple square thermal cavity problems are tested for laminar and turbulent conditions against numerical and experimental data. Throughout the investigation, it is found that the variable properties can affect the flow field in laminar condition, but the effect becomes weak in turbulence condition, and the CUPID code implementing steam table is capable of analyzing single phase natural circualtion phenomena.

Fault-Tolerant Control of Five-Phase Induction Motor Under Single-Phase Open

  • Kong, Wubin;Huang, Jin;Kang, Min;Li, Bingnan;Zhao, Lihang
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.899-907
    • /
    • 2014
  • This paper deals with fault-tolerant control of five-phase induction motor (IM) drives under single-phase open. By exploiting a decoupled model for five-phase IM under fault, the indirect field-oriented control ensures that electromagnetic torque oscillations are reduced by particular magnitude ratio currents. The control techniques are developed by the third harmonic current injection, in order to improve electromagnetic torque density. Furthermore, Proportional Resonant (PR) regulator is adopted to realize excellent current tracking performance in the phase frame, compared with Proportional Integral (PI) and hysteresis regulators. The analysis and experimental results confirm the validity of fault-tolerant control under single-phase open.

비정현 계통 전압하에서 단상 인버터의 PLL 성능 개선 방법 (A Method to Improve the Performance of Phase-Locked Loop (PLL) for a Single-Phase Inverter Under the Non-Sinusoidal Grid Voltage Conditions)

  • Khan, Reyyan Ahmad;Ashraf, Muhammad Noman;Choi, Woojin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 추계학술대회
    • /
    • pp.7-8
    • /
    • 2017
  • The Phase-Locked Loop (PLL) is widely used in grid-tie inverter applications to achieve the synchronization between the inverter and the grid. However, its performance is deteriorated when the grid voltage is not pure sinusoidal due to the harmonics and the frequency deviation. Therefore it is important to design a high performance phase-locked loop (PLL) for the single phase inverter applications to guarantee the quality of the inverter output. In this paper a simple method to improve the performance of the PLL for the single phase inverter is proposed. The proposed PLL is able to accurately estimate the fundamental frequency component of the grid voltage even in the presence of harmonic components. In additional its transient response is fast enough to track a change in grid voltage within two cycles of the fundamental frequency. The effectiveness of the proposed PLL is confirmed through the PSIM simulation and experiments.

  • PDF

단상전원에 접속된 3상 유도전동기의 손실분석 (Loss Analysis of Three Phase Induction Motor Connected to Single Phase Source)

  • 김도진;좌종근
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.121-126
    • /
    • 2008
  • This paper analyzes the losses of a Steinmetz connection three-phase induction motor which is supplied by a single-phase source. The T-type equivalent circuit which is taken no-load losses into account is used to determine phase converter capacitive reactances at starting and rated speed by using the condition of the minimum voltage unbalance. The starting and the operating capacitor are replaced at the slip of the same voltage unbalance factor points which are depicted using two capacitive reactances. The operation characteristics are investigated by comparing with those of three-phase balanced operation to find the feasibility of single-phase operation. To analyze the losses of this motor, the output power decrease factor(OPDF), the loss ratio(LR), the no load loss ratio(NLLR), the copper loss ratio(CLR), the stator copper loss ratio(SCLR), and the rotor copper loss ratio(RCLR) are defined and simulated in the whole slip range. The simulated results show that OPDF is maintained almost uniformly, LR is low at low speed and high at high speed, CLR is higher !ban NLLR, but CLR varies concavely and NLLR varies convexly at high speed, SCLR is low at low speed and high at high speed, but SCLR varies convexly at high speed, and RCLR is nearly opposite to SCLR.

단상유도전동기의 속도-부하의 검출을 위한 입력파라미터 특성 (A Characteristics of Input Parameters for Detecting of Speed-Load of SPIM)

  • 박수강;임양수;김평호;김대곤;조금배;백형래
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.964-966
    • /
    • 2003
  • The three-phase induction motor is rugged, reliable, long-lived, self-starting, smooth-running. But it is relatively inexpensive and three-phase power in not available everywhere, so if possible we need single-phase motor with the same characteristics. In fact, single-phase induction motors have excellent characteristics and outnumber the three-phase variety. Most of the small electric motors used in home, farm, or office are single-phase induction motors of one type or another. This electric motors application field need most energy saving type drive according to enlargement of electronic goods and to tend high class. The paper is proposed a various phase control methods for energy saving of single- phase induction motor. The controllers that are embodied by each method can use by various usage according to each performance and it is considered that application may help in the electrical energy saving because is possible to other electrical appliances.

  • PDF

단상 유도전동기의 벡터제어에 의한 고성능 운전 (High Performance of Single-Phase Induction Motor with Vector Control)

  • 이경주;이득기;김진규;정종진;김흥근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2776-2779
    • /
    • 1999
  • This paper describes the vector control of a single-phase induction motor drive system to improve the dynamic performance for low power applications. Using auxiliary winding which is only utilized for starting, the single-phase induction motor is regarded as the unsymmetrical two-phase motor. This paper shows that the vector control of single-phase induction motor with new method achieves the high performance of the motor. The results of the new method are illustrated by the simulations.

  • PDF

직접전력변환 방식을 이용한 전압 강하/상승 보상기의 구현 (Implementation of Voltage Sag/Swell Compensator using Direct Power Conversion)

  • 이상회;차한주;한병문
    • 전기학회논문지
    • /
    • 제58권8호
    • /
    • pp.1544-1550
    • /
    • 2009
  • In this paper, a new single phase voltage sag/swell compensator using direct power conversion is proposed. A new compensator consists of input/output filter, series transformer and direct ac-ac converter, which is a single-phase back-to-back PWM converter without dc-link capacitors. Advantages of the proposed compensator include: simple power circuit by eliminating dc link electrolytic capacitors and thereby, improved reliability and increased life time of the entire compensator; simple PWM strategy or compensating voltage sag/swell at the same time and reduced switching losses in the ac-ac converter. Further, the proposed scheme is able to adopt simple switch commutation method without requiring complex four-step commutation method that is commonly employed in the direct power conversion. Simulation and experimental results are shown to demonstrate the advantages of the new compensator and PWM strategy. A 220V, 3kVA single-phase compensator based on the digital signal processor controller is built and tested.

디지털제어기를 기반으로 하는 단상 능동전력필터 (Single-Phase Active Power Filter based on Digital Controller)

  • 배병열;이지헌;이혜연;주영아;한병문;박병주;윤동철
    • 전기학회논문지
    • /
    • 제57권5호
    • /
    • pp.789-796
    • /
    • 2008
  • This paper describes a single-phase active power filter based on a newly developed digital controller. The developed controller utilizes FFT(Fast Fourier Transform) algorithm to extract the reference signal from the load current, considering the phase-angle delay of each order of harmonics. Optimized technique was applied for whole control algorithm to implement the real-time operation of developed controller. The performance of developed controller for a single-phase active power filter was verified through computer simulations with PSCAD/EMTDC. The feasibility of hardware implementation was confirmed by building and testing a prototype. The developed digital controller for a single-phase active power filter can compensate the harmonic current generated by the power supply for digital equipment.

단상 직립기동 영구자석 동기전동기의 기동특성 해석 (Starting Characteristic Analysis of Single-Phase Line-Start Permanent Magnet Synchronous Motor)

  • 강규홍;홍정표
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권12호
    • /
    • pp.592-600
    • /
    • 2001
  • This Paper presents the transient analysis of the single-phase line-start permanent magnet synchronous motor. To analyse the starting characteristics, the dynamic equation which is combined electric dynamic equations with mechanical dynamic equation is used. The electric dynamics are derived from the d-q axis voltages of stator and rotor respectively. Especially, symmetrical components transformation is used to consider unbalanced magnetic field which is produced by single-phase input. Non-linear d-q axis inductances according to current amplitude and current phase angle are calculated by Finite Element Method and applied to lumped parameter circuit. The analysis methods are validated by comparing simulated and experimental results.

  • PDF

자기포화 특성을 고려한 단상유도전동기의 등가회로 해석 (Equivalent Circuit Analysis of Single Phase Induction Motor Considering Magnetic Saturation Characteristics)

  • 김영선
    • 전기학회논문지
    • /
    • 제62권2호
    • /
    • pp.270-277
    • /
    • 2013
  • Single phase induction motor(SPIM) is used widely because it is driven by single phase source. However, the efficiency of the motor is not good due to saturation of magnetic material. To analyze the motor accurately, the magnetic saturation characteristics should be considered in analysis of equivalent circuit. In this paper, lumped parameter of circuit are derived from multi phase induction motor using method of symmetrical coordinates. Also, we presents a method for the equivalent circuit analysis of SPIM using magnetic saturation rate. The magnetic nonlinearity is considered deriving magnetizing reactance from voltage-current saturation curve. As a results, current characteristic, torque, output and efficiency are shown through analysis of equivalent circuit. A simulation results of SPIM will be used to improve the characteristics and efficiency of motor.