• Title/Summary/Keyword: Single loop

Search Result 765, Processing Time 0.025 seconds

Positioning idle vehicles of AGVS on unidirectional guide paths (단방향 유도경로AGVS상의 유휴차량 대기위치 결정)

  • Kim, Jae-Yeon;Kim, Kap-Hwan
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.24 no.1
    • /
    • pp.77-93
    • /
    • 1998
  • It is discussed how to locate idle vehicles of AGVS on unidirectional guide paths. The problem is modeled as a median location problem on a cyclic network. The characteristics of the optimal location are analyzed and some useful properties are suggested to reduce the solution space. Based on the properties found, several special types of networks - a pure single-loop type, the loop type with a single branching intersection and the loop type with local branching node - are also analyzed as well as the general cyclic network. In each case of the networks, a solution procedure is suggested. Some numerical examples are provided to illustrate the algorithms developed.

  • PDF

New Cyclic Precoding Vectors for Open-loop Transmit Diversity Techniques

  • Lee, Kyoung-Jae;Lee, Heun-Chul;Lee, In-Kyu
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.5A
    • /
    • pp.347-354
    • /
    • 2009
  • In this paper, we propose a new transmit diversity technique for multiple-input multiple-output (MIMO) systems to improve the link level performance of open-loop systems. By cyclically applying a predetermined set of preceding weight vectors, artificially induced fluctuation is created to achieve additional diversity gain in flat fading channels. To design the set of the precoding vectors, we exploit the knowledge on the distribution of near optimum Preceding vectors observed in a beamforming scheme based on the rotation transformations. Simulation results demonstrate that the proposed open-loop diversity scheme with an arbitrary number of transmit antennas achieves a full diversity gain with computational complexity comparable to a single-input single-output (SISO) system.

All-Optical WDM Buffer System realized by NOLM and Feedback Loop (NOLM과 피드백 루프에 의해 구현된전광 WDM 버퍼 시스템)

  • 이승우;윤경모;이용기;엄진섭
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.5A
    • /
    • pp.514-520
    • /
    • 2004
  • In WDM networt a WDM buffer is one of essential elements for realizing all-optical packet switching system. In this paper, we propose and demonstrate a single loop type all-optical WDM buffer system. The proposed one consists of NOLM and feedback loop, and provides more than 40 turns buffering (more than 20${\mu}\textrm{s}$) for single input pulse (1550nm, width: 20㎱) before selected by control signal pulse (1553nm, width: 30㎱).

Small size PLL with D Flip-Flop (D플립플롭을 사용한 작은 크기의 위상고정루프)

  • Ko, Gi-Yeong;Choi, Hyuk-Hwan;Choi, Young-Shig
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.697-699
    • /
    • 2017
  • A novel structure of phase locked loop (PLL) which has small size with D Flip-Flop and sub charge pump has been proposed. The area of loop filter usually occupying the larger portion of the chip is minimized using a single small capacitor. It has been simulated and proved by HSPICE in a CMOS $0.18{\mu}m$ 1.8V process.

  • PDF

Improved DC Offset Error Compensation Algorithm in Phase Locked Loop System

  • Park, Chang-Seok;Jung, Tae-Uk
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1707-1713
    • /
    • 2016
  • This paper proposes a dc error compensation algorithm using dq-synchronous coordinate transform digital phase-locked-loop in single-phase grid-connected converters. The dc errors are caused by analog to digital conversion and grid voltage during measurement. If the dc offset error is included in the phase-locked-loop system, it can cause distortion in the grid angle estimation with phase-locked-loop. Accordingly, recent study has dealt with the integral technique using the synchronous reference frame phase-locked-loop method. However, dynamic response is slow because it requires to monitor one period of grid voltage. In this paper, the dc offset error compensation algorithm of the improved response characteristic is proposed by using the synchronous reference frame phase-locked-loop. The simulation and the experimental results are presented to demonstrate the effectiveness of the proposed dc offset error compensation algorithm.

Internal Model Control of UPS Inverter using Resonance Model

  • Park J. H.;Kim D. W.;Kim J. K.;Lee H. W.;Noh T. K.;Woo J. I.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.184-188
    • /
    • 2001
  • In this paper, a new fully digital control method for single-phase UPS inverter, which is based on the double control loop such as the outer voltage control loop and inner current control loop, is proposed. The inner current control loop is designed and implemented in the form of internal model control and takes the presence of computational time-delay into account. Therefore, this method provides an overshoot-free reference-to-output response. In the proposed scheme, the outer voltage control loop employing P controller with resonance model implemented by a DSP is introduced. The proposed resonance model has an infinite gain at resonant frequency, and it exhibits a function similar to an integrator for AC component. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been demonstrated by the simulation and experimental results respectively.

  • PDF

The Comparison of Reliability for Change Single Loop Configuration in Radial Power Distribution System (수지상 배전계통을 단일루프로 구조 변경시 신뢰도 비교)

  • Lee, Hee-Tae;Kim, Jae-Chul;Kim, Ju-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.8
    • /
    • pp.1472-1478
    • /
    • 2009
  • The domestic power distribution system is operating in an open loop mode; however, it already has a loop structure. Power distribution systems must be changed for bi-directions power supply for smart networks due to a changing of paradigm in electric power industry. The simplest bi-directions distribution networks can make it closing of normally open switch. However, bi-directions power supply is very difficulty to be operated and there are many parts which it must study. This paper presented various models that are able to change a radial system for loop structures. Further, we compared the reliability index for each model by evaluating the amount of improvement reliability required in radial power distribution system. In addition, we calculated CIC(Customer Interruption Cost) for each model by comparing and analyzing.

LINEAR AND NON-LINEAR LOOP-TRANSVERSAL CODES IN ERROR-CORRECTION AND GRAPH DOMINATION

  • Dagli, Mehmet;Im, Bokhee;Smith, Jonathan D.H.
    • Bulletin of the Korean Mathematical Society
    • /
    • v.57 no.2
    • /
    • pp.295-309
    • /
    • 2020
  • Loop transversal codes take an alternative approach to the theory of error-correcting codes, placing emphasis on the set of errors that are to be corrected. Hitherto, the loop transversal code method has been restricted to linear codes. The goal of the current paper is to extend the conceptual framework of loop transversal codes to admit nonlinear codes. We present a natural example of this nonlinearity among perfect single-error correcting codes that exhibit efficient domination in a circulant graph, and contrast it with linear codes in a similar context.

An Extremely Small Size Multi-Loop Phase Locked Loop (복수개의 부궤환 루프를 가진 초소형 크기의 위상고정루프)

  • Choi, Young-Shig;Han, Geun-Hyeong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.1
    • /
    • pp.1-6
    • /
    • 2019
  • An extremely small size multi-loop phase-locked loop(PLL) keeping phase noise performances has been proposed. It has been designed to have the loop filter made of small single capacitor with multiple Frequency Voltage Converters (FVCs) because the main goal is to make the size of the proposed PLL extremely small. Multiple FVCs which are connected to voltage controlled oscillator(VCO) make multiple negative feedback loops in PLL. Those multiple negative feedback loops enable the PLL with the loop filter made of an extremely small size single capacitor operate stably. It has been designed with a 1.8V $0.18{\mu}m$ CMOS process. The simulation results show that the proposed PLL has the 1.6ps jitter and $10{\mu}s$ locking time.

Development of a Single Tangle Net for the Brown Shrimp by Observation of Entanglement Behaviour

  • Kim Yong-Hae
    • Fisheries and Aquatic Sciences
    • /
    • v.6 no.1
    • /
    • pp.34-40
    • /
    • 2003
  • Three panel trammel nets were made illegal for the brown shrimp (Penaeus japonicus) or fishes by Korean fisheries law while trammel nets for fleshy prawn in the West sea remained legal. In this study a single panel tangle net with vertical loop lines rigged between the float line and sinker line was specially designed to catch brown shrimp. This net was developed for the first time after observation of the brown shrimp behaviour when reacting to a net in an observation tank. In field experiments these single tangle nets were compared with the traditional trammel nets in the coastal waters of the Keoje area. The mean number of the brown shrimp for 53 fishing operations was 1.13 per unit panel of the single tangle nets when fitted with the vertical loop lines. This was $84\%$ of the mean catch of 1.36 achieved with the trammel nets. These results of fishing experiments using single tangle nets in the field revealed a high fishing efficiency for the brown shrimp and showed little difference from trammel nets. The size of the brown shrimp or number of by-catch was not different between single tangle nets and trammel nets.